Efficient Verification of X-ray Target Replacement for the C-series High Energy Linear Accelerator

  • Cho, Jin Dong;Chun, Minsoo;Son, Jaeman;An, Hyun Joon;Yoon, Jeongmin;Choi, Chang Heon;Kim, Jung-in;Park, Jong Min;Kim, Jin Sung
    • 한국의학물리학회지:의학물리
    • /
    • 제29권3호
    • /
    • pp.92-100
    • /
    • 2018
  • The manufacturer of a linear accelerator (LINAC) has reported that the target melting phenomenon could be caused by a non-recommended output setting and the excessive use of monitor unit (MU) with intensity-modulated radiation therapy (IMRT). Due to these reasons, we observed an unexpected beam interruption during the treatment of a patient in our institution. The target status was inspected and a replacement of the target was determined. After the target replacement, the beam profile was adjusted to the machine commissioning beam data, and the absolute doses-to-water for 6 MV and 10 MV photon beams were calibrated according to American Association of Physicists in Medicine (AAPM) Task Group (TG)-51 protocol. To verify the beam data after target replacement, the beam flatness, symmetry, output factor, and percent depth dose (PDD) were measured and compared with the commissioning data. The difference between the referenced and measured data for flatness and symmetry exhibited a coincidence within 0.3% for both 6 MV and 10 MV, and the difference of the PDD at 10 cm depth ($PDD_{10}$) was also within 0.3% for both photon energies. Also, patient-specific quality assurances (QAs) were performed with gamma analysis using a 2-D diode and ion chamber array detector for eight patients. The average gamma passing rates for all patients for the relative dose distribution was $99.1%{\pm}1.0%$, and those for absolute dose distribution was $97.2%{\pm}2.7%$, which means the gamma analysis results were all clinically acceptable. In this study, we recommend that the beam characteristics, such as beam profile, depth dose, and output factors, should be examined. Further, patient-specific QAs should be performed to verify the changes in the overall beam delivery system when a target replacement is inevitable; although it is more important to check the beam output in a daily routine.

고 에너지 광자선 계측용 2차원 광섬유 방사선 센서의 제작 및 특성분석 (Fabrication and Characterization of Two-dimensional Fiber-optic Radiation Sensor for High Energy Photon Beam Therapy Dosimetry)

  • 장경원;조동현;신상훈;김형식;이정한;이봉수;김신;조효성
    • 한국광학회지
    • /
    • 제18권4호
    • /
    • pp.241-245
    • /
    • 2007
  • 본 연구에서는 유기 섬광체와 플라스틱 광섬유를 이용하여 치료용 광자선의 계측을 위한 2차원 광섬유 방사선 센서를 제작하였다. 제작된 센서를 사용하여 광자선 조사야(Field size)와 에너지에 따른 선형가속기의 빔 분포도를 2차원적으로 측정하였으며 polymethylmethacrylate(PMMA)팬텀 내에서 깊이에 따른 섬광체의 광량을 측정하여 깊이선량 분포(Percent Depth Dose, PDD) 또한 2차원으로 측정하였다. 본 연구를 통하여 개발된 2차원 광섬유 방사선 센서는 고 분해능, 실시간 측정, 쉬운 보정 등 많은 장점을 가지고 있다.

광섬유 방사선량계를 이용한 Co-60 방사선원으로부터 조사되는 상대선량측정 (Measurement of relative dose irradiated from a Co-60 source using a scintillating fiber-optic dosimeter)

  • 장경원;조동현;유욱재;서정기;허지연;이봉수;신상훈;박병기;김신
    • 센서학회지
    • /
    • 제19권1호
    • /
    • pp.52-57
    • /
    • 2010
  • In this study, we have fabricated a scintillating fiber-optic dosimeter for a radiotherapy dosimetry. And ${\gamma}$-rays generated by a Co-60 are measured using a scintillating fiber-optic dosimeter and percent depth dose curves are obtained according to the different depths of solid water phantoms. Also, Cerenkov radiations generated by primary or secondary electrons are measured at different depths of water phantom using a background optical fiber.

광자극발광선량계(OLSDs)를 이용한 직장암 방사선치료 환자의 피부선량 측정 (Measurement of Skin Dose for Rectal Cancer Patients in Radiotherapy using Optically Stimulated Luminescence Detectors (OSLDs))

  • 임인철;유윤식;이재승
    • Journal of Radiation Protection and Research
    • /
    • 제36권2호
    • /
    • pp.86-92
    • /
    • 2011
  • 본 연구는 최근 생체내선량측정에서 유용성을 재평가 받고 있는 광자극발광선량계(optically stimulated luminescence dosimeters. OSLDs)와 다이오드 검출기를 병행하여 직장암 방사선치료 환자의 피부선량을 측정하고 치료계획시스템 에서 계산 선량과 측정 선량을 비교하여 OSL 선량계의 임상적 유용성을 평가하고자 하였다. 각 OSL 선량계의 고유한 교정상수를 측정하고 10 명의 직장암 환자를 대상으로 3 부위를 설정하여 측정하였다. 기준 흡수선량 100 cGy에 대하여 OSL 선량계의 교정상수는 6 MV X-선의 경우 1.17, 10 MV X-선의 경우 1.28 이었다. 또한 직장암 환자들의 피부선량은 측정 부위별로 치료계획시스템에서 계산 선량과 비교하여 다이오드 검출기는 1.16 ~ 2.83%의 선량증가를 보였고 OSL 선량계는 1.36 ~ 2.17%의 선량증가를 보였다. 특히 피부면의 굴곡이 심한 회음부(perineum)에서 계산된 선량과 전달 선량간 차이가 증가되었으며 다이오드 검출기보다 OSL 선량계가 측정값의 변화가 상대적으로 작았다. 따라서 OSL 선량계는 기존에 사용하던 이온함 및 다이오드 검출기를 대신하여 방사선량학적 오차의 검증 및 생체내선량측정에서 임상적으로 적용이 가능하였으며 직장암 환자의 굴곡이 심한 회음부 주변의 선량 평가에 대한 연구가 계속되어야 할 것으로 판단된다.

가우시안 근사를 이용한 6 MeV 전자선의 에너지분포에 관한 연구 (Study on Energy Distribution of the 6 MeV Electron Beam using Gaussian Approximation)

  • 이정옥;김승곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권2호
    • /
    • pp.53-56
    • /
    • 1999
  • A Gaussian distribution was parametrized for the initial distribution of the electron beam emitted from a 6MeV medical linear accelerator. A percent depth dose was measured in a water phantom and the corresponding Monte Carlo calculations were performed starting from a Gaussian distribution for a range of standard deviations, ${\sigma}=0.1$, 0.15, 0.2, 0.25, and 0.3 with being the mean value for the Incident beam energy. When measurement and calculation were compared, the calculation with the Gaussian distribution for ${\sigma}=0.25$ turned out to agree best with the measurement. The results from the present work can be utilized as input energy data in planning an electron beam therapy with a Monte Carlo calculation.

  • PDF

6MV X-선 선축중심선상에서의 BEAM 특성 - Siemens MEVATRON KD 선형가속기에서 P. D. D와 TMR을 중심으로 - (The Central Beam Characteristics of 6 MV X-Ray - The PDD and TMR for Siemens Linear Accelerator K.D. -)

  • 정칠;김병욱
    • 대한방사선치료학회지
    • /
    • 제3권1호
    • /
    • pp.63-67
    • /
    • 1989
  • The central beam characteristics of 6 MV X-ray from a Mevatron KD linear Accelerator are examin-depths The PDD (Percent Depth Dose) values and the TMR (Tissue Maximum Ratio) values are evaluated from measurement as a function of the depths and the field sizes. The calculated TMR values from the PDD are compared to those from measurement. The average differences between calculated TMR and measured one are within $1\%$ and we have concluded that calculated TMR values are acceptable for practical use.

  • PDF

6MV X-선에 대한 조직 보상체의 제작 및 응용에 관한 연구 (A Study on Design and Application of Tissue Compensator for 6MV X-rays)

  • 채규영;최은경;정웅기;강위생;하성환;박찬일
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.123-132
    • /
    • 1989
  • A radiation beam incident on an irregular or sloping surface produces the non-uniformity of absorded dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator is designed based on the patient's three dimensional contour. After required compensator thickness was determined according to tissue deficit at $25cm\pm25cm$ field size, 10cm depth for 6MV x-rays, tissue deficit was mapped by isoheight technique using laser beam system. Compensator was constructed along the designed model using 0.8mm lead sheet or 5mm acryl plate. Dosimetric verification were peformed by film dosimetry using humanoid phantom. Dosimetric measurements were normalized to central axis full phantom readings for both compensated and non-compensated field. Without compensation, the percent differences in absorbed dose ranged as high as $12.1\%$ along transverse axis, $10.8\%$ along vertical axis. With the tissue compensators in place, the difference was reduced to $0\~43\%$ Therefore, it can be concluded that the compensator system constructed by isoheihnt technique can produce good dose distribution with acceptible inhomogeneity, and such compensator system can be effectively applied to clinical radiotherapy.

  • PDF

Dynamic Wedge의 조직내 방사선량 분포의 특성 (Dosimetric Characteristics of Dynamic Wedge Technique)

  • 오영택;금기창;추성실;김귀언
    • Radiation Oncology Journal
    • /
    • 제14권4호
    • /
    • pp.323-332
    • /
    • 1996
  • 목적 : 방사선 치료에 있어서 조직내 등선량 분포곡선을 변형시킬 목적으로 쐐기 차폐물이 사용되고 있는데 최근 기존의 고정 쐐기와는 다르게 비대칭적인 콜리메이터인 Independent Jaw에 의해 등선량 분포곡선을 변형시키는 동적 쐐기 기법이 실용화 되고 있으나 아직 그 방사선 물리학적인 특성에 대해서는 잘 알려져 있지 않다. 이에 본 저자는 기존의 고정 쐐기와 비교하여 조직내 방사선량 분포의 특성을 알아보고자 본 연구를 계획하였다. 대상 및 방법 : 물 판톰, 폴리 스타이린 판톰, 평균 유방 모형 판톰을 대상으로 전리함, 필름, TLD 등을 이용하여 동적 쐐기와 고정 쐐기의 선량 분포를 측정하여 비교하였다. 방사선원은 선형 가속기의 6MV x선을 사용하였고 $15{\times}15$ 조사면에서 15, 30, 45도 쐐기를 이용하였다 조직내선량 분포는 전리함과 필름 선량계를 사용하였고, 유방 접선 치료방식에서의 반대편 유방 조사선량은 TLD를 사용하였다. 결과 : 1) 조직내 $\%$심도 선량은 고정 쐐기의 경우 심도 선량 깊이가 깊어지는 방사선의 경화 현상이 뚜렷하였으나 동적 쐐기의 경우에는 발견할 수 없었으며 그 $\%$심도선량은 개방 조사면과 유사하였다. 2) 조직내 등선량 분포 곡선을 보면 동적 쐐기의 경우 고정 쐐기와는 달리 원하는 깊이, 원하는 조사면에서 원하는 쐐기 각도를 얻을 수 있었으며 쐐기 각도를 이루는 등선량 분포 곡선이 고정 쐐기에 비해 더욱 직선적이었다. 3) 산란선량은 동적 쐐기의 경우 개방 조사면과 그 양이 거의 동일하였으며 유방보존술에서의 접선 조사방식의 방사선치료에서 고정 쐐기 대신에 동적 쐐기를 사용함으로써 반대측 유방으로의 피폭선량을 감소시킬 수 있었다. 결론적으로 동적 쫴기 기법은 단순히 고정 쐐기를 대체할 수 있을 뿐만 아니라 고정 쐐기의 단점을 보완해 줄 수 있으며 향후 방사선 치료에 있어서 더 다양한 유용성을 가질 수 있으리라 생각한다.

  • PDF

비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구 (A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability)

  • 조병철;오도훈;배훈식
    • Radiation Oncology Journal
    • /
    • 제16권1호
    • /
    • pp.71-79
    • /
    • 1998
  • 목적 : 비 상업용 3차원 컴퓨터치료계획시스템인 Plunc의 구축 사례를 소개하고 이의 임상적용 가능성에 대하여 검증하고자 한다. 대상 및 방법 : 미국 North Carolina 대학에서 개발된 3차원 치료계획시스템인 Plunc의 소스코드를 제공받아, PC용 Unix인 Linux 환경의 Pentium Pro 200MHz(128MB RAM, Millennium VGA)에서 설치하였다. 본과의 6MV 광자선(Siemens MXE 6740)에 대한 출력인자, 최대산란비, 최대산란인자, 쐐기의 모양 및 감쇄인자 등의 빔데이터를 입력한 후, 일반적인 치료조건인 loom 깊이의 회전중심점에서의 심부선량백분율, 선량측면도, oblique 입사빔 및 공기간격 하에서의 선량계산 결과를 물팬톰에서의 측정치와 비교, 분석하였다. 결과 : Plunc는 원래 CT 영상데이터를 이용한 모의치료기로써 개발되어, 빔 설계가 매우 편리하도록 사용자 인터페이스가 구성되어 있으며, BEV, DRR 및 영상합성 등의 기능을 갖추고 있다. 선량계산은 10초 정도가 소요되는 3차원 선량분포나 선량체적히스토그람을 제외하고는 거의 실시간으로 실행되었다. Plunc에 의한 선량 계산 값을 측정값과 비교한 결과, 심부선량백분율의 경우, 선량증가영역을 제외하고는 $1\%$이내에서 일치하였다. 또한, 선량측면도의 경우, $5\%$가량의 선량감소를 나타내는 치료영역 크기 밖의 저선량 영역을 제외하고는 $2\%$ 이내에서 일치하였다. Oblique 입사 빔의 경우, 빔 중심축을 포함하는 평면상의 선량분포가 선량이 $30\%$ 이하인 영역을 제외하고는 비교적 잘 일치하였다. 공기간격을 통과한 빔에 대한 선량측면도의 비교 결과, 중심 축에서의 선량 값에 대해 $5\%$의 오차를 보였다. 결론 : Plunc의 광자선량계산의 정밀도는 일반적인 치료조건하에서 약 $2-5\%$ 내외의 오차로써, 측정치에 대한 보정에 근거한 알고리즘을 사용하는 일반 치료계획시스템과 비슷한 수준이라 사료된다. 현재로서는 전자선에 대한 선량계산이 불가능하기 때문에 완전한 형태의 치료계획시스템이 되기 위해서는 향후, 전자선에 대한 계산모듈의 개발과 광자선 선량계산 또한 보다 정밀한 선량계산이 가능한 컨벌루션 방법과 같은 3차원 선량계산모듈의 개발도 필요하다. Plunc는 상업용 3차원 치료계획 시스템의 사용이 현실적으로 어려운 여건의 병원에서 2차원 치료계획시스템과 상호 보완적으로 사용한다면 2차원 치료계획시스템이 갖는 많은 제약을 극복할 수 있을 것으로 사료된다.

  • PDF

방사선치료계획시스템의 Collapsed Cone Convolution 선량계산 알고리듬을 이용한 빔 모델링의 정확성 평가 (Evaluation of Beam Modeling Using Collapsed Cone Convolution Algorithm for Dose Calculation in Radiation Treatment Planning System)

  • 정주영;조웅;김민주;이정우;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제23권3호
    • /
    • pp.188-198
    • /
    • 2012
  • 본 연구의 목적은 국내 개발된 치료계획장치(Treatment Planning System, TPS)인 CorePLAN$^{TM}$에서의 빔 모델링을 기반으로 하는 Collapsed Cone Convolution (CCC) 선량 계산 알고리듬의 정확성을 평가하는 것이다. 여러 셋업 조건에 따라 빔 모델을 TPS에 생성하였고, 6 MV와 15 MV 광자 에너지에 대하여 $50{\times}50{\times}50cm^3$의 물 팬톰 내에서 CCC 알고리듬을 사용하여 선량 계산을 하였다. 대상 조사면은 $4{\times}4cm^2$, $6{\times}6cm^2$, $10{\times}10cm^2$, $20{\times}20cm^2$, $30{\times}30cm^2$$40{\times}40cm^2$을 대상으로 하였고, 각각에 대하여 열린 조사면과 쐐기 조사면으로 구분하였다. 생성된 빔 모델들은 측정된 데이터와 계산된 데이터의 심부선량백분율(Percent depth dose, PDD)과 선량프로파일(lateral profile)을 비교하여 모든 깊이에서도 잘 맞는지 평가하였다. 측정된 방사선량과 CorePLAN$^{TM}$에서 CCC 알고리듬을 이용하여 계산된 방사선량은 PDD에 있어 build-up 영역을 제외하고 열린 조사면은 최대 2%, 쐐기 조사면는 최대 3% 이내로 일치하였다. 선량프로파일은 조사면 내 영역에서는 1%, 반음영 영역에서는 4% 이내로 일치함을 확인하였다. 모든 조사면에서 반음영을 제외한 $10{\times}10cm^2$에서 최대 $40{\times}40cm^2$까지의 선량프로파일에 대하여 측정된 방사선량과 계산된 방사선량이 3% 이내로 일치하였다. 반면에, 열린 조사면에 비하여 쐐기 조사면에서 선량 차이가 뿔(horn) 영역의 가장자리에서 4%까지 높게 나타났다. 본 연구 결과에서 보여주는 선량 차이는 일부 영역을 제외하고 국제 기준에 적합한 결과값을 보였다. 선량 차이가 크게 발생하는 영역은 임상적으로 중요성이 크지 않은 표면 영역임을 감안할 때, 임상에서의 활용이 가능하리라 기대된다.