플라스틱 섬광체와 상용 50 mm, f1.8 렌즈 및 고감도 CMOS 카메라를 사용하여 방사선치료 시 흡수선량을 측정할 수 있는 광 도시메트리 시스템을 구축하였다. 아울러 촬영된 방사선 분포 영상에 대한 비네팅 보정, 기하학적 왜곡 보정, 스케일 보정을 통하여 화소값으로 선량을 교정하는 절차를 확립하였다. 개발된 광 도시메트리 시스템을 6 MV 의료용 선형가속기에 대하여 선량 특성 평가를 수행한 결과, 심부선량백분율은 이온챔버로 측정한 결과에 비하여 빌드 업 깊이 이상에서는 오차 범위 2% 이내로 일치하였으며, 90% 조사야에 대하여 2.8%의 평탄도가 측정됨에 따라 방사선치료선량 측정 시스템으로서의 충분한 활용가능성을 확인하였다.
The solid state detector system was constructed using commercially available rectifier diode for the assessment of quality assurance in radiotherapy. Dosimetry system which consists of the electrometer and the water phanton was used for measuring small field size scanning. The measured results, which had linearity in accordance with variation of radiation dose for gamma-ray of Co- 60 and 6 and 10MV photons of linear accelerator, showed quite linear characteristics within 1% error. The percent depth dose of 10MV photon of Mevatron KD linear accelerator was measured in small field size using diode, and the results were compared with that of using ion chambers. The results show that the difference of percent depth dose between the value of diode and that of ion chamber was negligible in large field size. However, in small size less than 4$\times$4cm, the difference of percent depth dose estimated by diode and ion chamber was 4.7% by extrapolation to 0$\times$0cm. Considering the smaller volume of diode than that of ion chamber, it might be more reliable to use diode for estimating percent depth dose. Above results suggest that diode can be used for routine check such as beam profile, flatness, symmetry and energy
Experimental measurements of dose characteristics with pentagonal applicator at nominal energy of 4, 6, 9, 12 and 15 MeV electron beam were performed for intraoperative radiotherapy (IORT) in ML-15MDX linear accelerator. This paper presents the percent depth dose, surface dose, beam flatness and output factors of using the IORT applicator in different electron beam energy. The output factor showed as a 24 percent higher in IORT applicator than that of reference $10{\times}10cm^2$ applicator. The surface dose of using the IORT applicator showed 7.7 and 2.7 percent higher than that of reference field in 4 and 15 MeV electron beam, respectively. In our experiments, the variation of percent depth dose was very small but the output factor and flatnees at 0.5 cm depth have showed a large value in IORT applicator.
Co ${\gamma}$선과 10MV x선으로 폴리스티렌 팬톰에 조사하여 이온함으로 배면과 배면근처의 선량을 측정한 결과는 아래와 같다. 1. 측정점 이하의 팬톰의 두께가 증가함에 따라 선량율과 선량보정계수가 증가하였으며 그 두께가 20cm 이상인 경우에는 일정하였다. 선량보정계수는 1 이하였다. 2. 조사면의 크기가 클수록, 측정점의 깊이가 깊을 수록 선량보정계수는 감소하였다. 3. 선량에 후방산란선량의 기여도는 조사면이 클수록, 깊이가 얕을수록, 그 깊이 이하의 물질의 두께가 두꺼울수록 증가하였다. 4. 10MV x선의 경우에도 선량보정계수는 같은 유형으로 변하기는 했지만 그 값이 0.995~1.000이었다. 5. $^{60}Co$에 경우에 치료부위의 두께가 10cm 이상이면 조사시간을 보정하지 않아도 좋을 것이다.
The treatment planning and dosimetry of small fields for stereotactic radiosurgery with 10 MV x-ray isocentrically mounted linear accelerator is presented. Special consideration in this study was given to the variation of absorbed dose with field size, the central axis percent depth doses and the combined moving beam dose distribution. The collimator scatter correction factors of small fields $(1\times1\~3\times3cm^2)$ were measured with ion chamber at a target chamber distance of 300cm where the projected fields were larger than the polystyrene buildup caps and it was calibrated with the tissue equivalent solid state detectors of small size (TLD, PLD, ESR and semiconductors). The central axis percent depth doses for $1\timesl\;and\;3\times3cm^2$ fields could be derived with the same acuracy by interpolating between measured values for larger fields and calculated zero area data, and it was also calibrated with semiconductor detectors. The agreement between experimental and calculated data was found to be under $2\%$ within the fields. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor regions was performed with dose planning computer system (Therac 2300) and was verified with film dosimetry. The more the number of strips and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. The circular cone, we designed, improves the alignment, minimizes the penumbra of the beam and formats ball shape of treatment area without stellate patterns. These dosimetric techniques can provide adequate physics background for stereotactic radiosurgery with small radiation fields and 10MV x-ray beam.
Tatcher식에 의하여 조직최대선량비와 깊이선량을 6MV X-선의 중심축상에서 측정하였다. 쐐기형 조사야에 있어서 깊이, 조사야 및 쐐기의 두께 등이 증가할수록 깊이선량은 개방 조사야에 비하여 크기가 증가하였다. 그러나 쐐기형 조사야에 있어서 조직산란보정 계수는 개방 조사야에 비하여 그 차이가 $1\%$ 미만이었다. 두 조사야에 있어서 중심축상의 깊이선량백분률의 차이가 발생하는 것은 쐐기에 의해서 X-선이 강화됨을 의미한다. 같은 각도의 쇄기에서 깊이선량백분률과 산란보정계수의 명목쐐기형 조사야와 유효쐐기형 조사야사이의 차이는 없었다. 개방조사야에서 조사야 $6cm{\times}6cm$, 깊이 7cm의 깊이선량백분률은 명목 또는 유효쐐기형 조사야 보다 $3.26\%$가 더 컸다. 그러나 조사야 $(10cm{\times}10cm)$가 커질수록 깊이선량백분률의 차이는 명목 또는 유효쐐기형 조사야보다 더 증가하였다-선량계측차이는 깊이 7cm에서 $3.56\%$, 12cm에서는 $5.30\%$였다 그러므로 심부종양치료시 선량의 계산이나 모니터세팅은 각 쐐기의 깊이 백분선량률과 투과율을 사용하여야 오차를 줄일 수 있을 것으로 사료된다.
20 MeV 전자선의 팬텀 내에서의 선량분포에 대한 횡방향 자기장 효과를 조사하기 위하여 전자석을 제작하여 자기장 인가 여부에 따른 등선량곡선 및 깊이선량율을 X-OMAT 필름으로 측정하였다. 1.5 Tesla의 자기장중심을 팬텀 표면으로부터 7.5 cm 깊이에 위치시킨 경우 팬텀 표면으로부터 4.5 cm 깊이에서 약 30%의 선량증가를 보이는 등 이론적으로 알려진 결과들과 잘 부합하고 있음을 확인하였다.
목적 : 6 MeV의 전자선에 대하여 Monte-Carlo기법을 이용한 모의계산(simulation)과 측정을 함으로써 측정값과 계산값을 서로 비교하고, 이러한 모의계산이 측정을 대신할 수 있을 만큼의 정확도가 있는지를 확인하고자 하였다. 방법 : 선형가속기에서 출력되는 전자선의 심부량 백분율(percent depth dose)을 물팬톰에서 반도체 검출기를 이용하여 조사야 $50{\times}50,\;100{\times}100,\;150{\times}150,\;200{\times}200\;mm^2$에 대하여 측정하였다. 전자선에 대한 선량을 결정하기 위한 모의계산은 EGS4 프로그램을 사용하였다. 결과 : 측정값과 계산값은 유사한 형태로 나타났는데 $100{\times}100\;mm^2$ 조사야 에서 선축상최대선량은 측정값과 계산값이 각각 14mm 와 15mm, 표면선량율은 각각 $76.94\%$ 와 $65.52\%$였다. 모의계산에서 표면선량율의 조사야에 따른 변화는 $64.43\%-66.99\%$이고 선축상최대선량은 15mm-18mm 였다. 결론 : 모의계산을 한 결과, 계산값이 측정값과 비교적 잘 일치한다는 것을 알았다. 표면선량율의 차이만을 제거하고 결과를 살펴보면 선축상 최대치등 방사선 치료에 주로 이용되는 부츤의 선량율에서는 모의계산이 측정을 대신할 수 있을 만큼의 정확도가 있다는 것을 확인하였다.
Purpose : The aim of this study is to investigate the effect of tissue inhomogeneities when appling to contrast medium among Homogeneous, Batho and ETAR dose calculation method in RTP system. Method and Material : We made customized heterogeneous phantom it filled with water or contrast medium slab. Phantom scan data have taken PQ 5000 (CT scanner, Marconi, USA) and then dose was calculated in 3D RTP (AcQ-Plan, Marconi, USA) depends on dose calculation algorithm (Homogeneous, Batho, ETAR). The dose comparisons were described in terms of 2D isodose distribution, percent depth dose data, effective path length and monitor unit. Also dose distributions were calculated with homogeneous and inhomogeneous correction algorithm, Batho and ETAR, in each patients with different clinical sites. Results : Result indicated that Batho and ETAR method gave rise to percent depth dose deviation $1.5{\sim}2.7\%,\;2.3{\sim}3.5\%$ (6MV, field size $10{\times}10cm^2$) in each status with and without contrast medium. Also show that effective path lengths were more increase in contrast status (23.14 cm) than Non-contrast (22.07 cm) about $4.9\%$ or 10.7 mm (In case Hounsfield Unit 270) and these results were similary showned in each patient with different clinical site that was lung. prostate, liver and brain region. Concliusion : In conclusion we shown that the use of inhomogeneity correction algorithm for dose calculation in status of injected contrast medium can not represent exact dose at GTV region. These results mean that patients will be more irradiated photon beam during radiation therapy.
목적 : 두경부종양 환자의 방사선치료시 두경부의 고정에 흔히 이용되는 Aquaplast가 광자선의 표면선량에 미치는 영향을 알아보기 위하여 이 실험을 시행하였다. 재료 및 방법 : 6MV X-선(Siemens Mevatron 6740)의 표면선량과 선량증가영역의 선량을 PTW Frieburg 제작의 Markus chamber와 Capintec Model WK92 Electrometer를 이용하여 측정 하였다. $25{\times}25{\times}5cm^3$ 크기 아크릴판의 중앙에 고정된 전리함을 $25{\times}25{\times}5cm^3$ 크기의 폴리스티렌 팬톰 위에 올려 놓고 표면선량을 측정한 후 적당한 두께의 폴리스티렌 팬톰판을 올려가면서 선량증가영역의 선량을 측정하였다. 1.6mm 두께의 Aquaplast(WFR Aquaplast Corp. 제작)를 원형 그대로, 그리고 실제 환자의 고정시와 비슷한 정도로 변형시킨 상태로 전리함 위에 올려 놓은 후 각각 같은 방법으로 선량을 측정하였다. 또 트레이를 장착한 후 변형된 Aquaplast가 있는 상태에서와 없는 상태에서 각각 표면선량을 측정하였다. 모든 측정은 SSD 100cm에서 시행하였으며 $5{\times}5cm^4$, $10{\times}10cm^2$, $15{\times}15cm^2$의 세 가지 크기의 조사면에 대하여 각각 측정하였다. 표면선량과 선량증가영역의 선량 백분율은 Markus chamber의 과반응을 교정하기 위하여 Gerbi와 Khan이 제시한 식을 이용하여 구하였다. 결과 : $5{\times}5cm^2$, $10{\times}10cm^2$, $15{\times}15cm^2$의 조사면에서 표면선량은 각각 $7.9\%$, $13.6\%$, $18.7\%$ 이었고 원형 그대로의 Aquaplast가 있을 경우 표면선량은 각각 $38.4\%$, $43.6\%$, $47.4\%$ 이었으며 변형된 Aquaplast가 있을 경우의 표면선량은 각각 $31.2\%$, $36.1\%$, $40.5\%$ 이었다. 최대선량점 이상의 깊이에서는 거의 비슷한 선량 백분율을 보였다. 트레이는 조사면의 크기가 증가함에 따라 Aquaplast가 없을 경우 $0.2\%$, $1.7\%$, $3.0\%$의 표면선량 증가에 기여하였으며 변형된 Aquaplast가 있을 경우 $0.2\%$, $1.9\%$, $3.7\%$의 표면선량 증가를 보였다. 결론 : Aquaplast를 사용하지 않았을 경우에 비하여 Aquaplast를 원형 그대로 사용하였을 경우 약 $30\%$, 실제 환자의 고정시와 비슷한 정도로 변형하였을 경우 약 $22\%$의 표면선랑 증가를 가져왔으며 최대선량점 깊이 이상에서의 선량 백분율에는 건의 영향을 미치지 않았다. 실제 환자에서의 Aquaplast의 사용은 피부 및 선량증가영역의 선량을 약간 증가시키지만 임상적으로 크게 문제가 되지는 않을 것으로 생각된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.