• Title/Summary/Keyword: per unit area

Search Result 1,124, Processing Time 0.031 seconds

Effects of Distribution of Axle Load and Inflation Pressure of Tires on Fuel Efficiency of Tractor Operations (차축의 중량 분포와 타이어의 공기압이 트랙터 작업의 연료 효율에 미치는 영향)

  • Lee, Jin-Woong;Kim, Kyeong-Uk;Gim, Dong-Hyeon;Choi, Kyu-Jeong
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.303-313
    • /
    • 2011
  • This study was conducted to investigate the effects of axle weight distribution and inflation pressure of tire on the fuel economy of tractors as well as operational range of tractor engine in terms of engine speed and power when a 4WD tractor of 38.2 kW rated power at 2500 rpm is used for plowing and flooded-field rotavating in paddy fields. (1) Plowing operation required an average engine power of 9.6~13.5 kW which equals 25~35% of rated PTO power. Engine speed ranged from 1,320.4 to 1,737.4 rpm, work velocity from 3.4 to 4.8 km/h, and fuel consumption from 3.2 to 4.2 L/h, respectively. (2) Flooded-field rotavating required an average engine power of 11.5~18.5 kW which equals 30~48.4% of rated PTO power. Out of this 6.2~12.2 kW was used for PTO power. Engine speed ranged from 1,557 to 2,067 rpm, work velocity from 2.5~5.4 km/h and fuel consumption from 3.2~5.5 L/h, respectively. (3) Axle weight distribution, inflation pressure of tire and moisture content of soil did not affect significantly the specific volumetric fuel consumption but affected significantly the fuel consumption per unit area of operation. Fuel savings amounted to 65% in plowing operation and 20% in flooded-field rotavating when the axle weight distribution and inflation pressure of tire were optimally adjusted. (4) Optimal adjustment of axle weight distribution and inflation pressure of tire are expected to save fuel consumption by 10~65% per unit area of operation in plowing and 10~20% in flooded-field rotavating.

Let's feel warmth with VR sensing modeling (온기를 느끼게 하는 VR 센싱 모델링)

  • Moon, Dongmin;Chin, Seongah
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.341-346
    • /
    • 2020
  • Motion sickness or dizziness caused by visual and other sensory inconsistencies In virtual reality content seems to be a major problem. To solve the problem, research has been actively underway to satisfy the five senses. Among them, the most researches on the touch are many studies on hardness and texture, but the studies on temperature seem relatively small. Therefore, in this paper, we present a calculation model that can sense the temperature derived from the principle of heat energy moving from high temperature to low temperature, not the temperature of the material. Because heat energy is determined by the heat conductivity, temperature, and area of contact, which are the inherent characteristics of a material, the degree of heat felt by a person depends on the type of material, the temperature of the material and the area of contact with the object. The thermal energy shift per unit time of the material was calculated using the thermal conductivity law and the specific heat formula, and the thermal energy reproduction method that changes per unit time of the material was studied using the thermoelectric element.

Improvement of Surface-enhanced Raman Spectroscopy Response Characteristics of Nanoporous Ag Metal Thin Film with Surface Texture Structures (표면 요철구조를 적용한 나노 다공성 Ag 금속박막의 SERS 응답 특성 개선)

  • Kim, Hyeong Ju;Kim, Bonghwan;Lee, Dongin;Lee, Bong-Hee;Cho, Chanseob
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.255-260
    • /
    • 2020
  • In this study, we developed a method of improving the surface-enhanced Raman spectroscopy (SERS) response characteristics by depositing a nanoporous Ag metal thin film through cluster source sputtering after forming a pyramidal texture structure on the Si substrate surface. A reactive ion etching (RIE) system with a metal mesh inside the system was used to form a pyramidal texture structure on the Si surface without following a complicated photolithography process, unlike in case of the conventional RIE system. The size of the texture structure increased with the RIE process time. However, after a process time of 60 min, the size of the structure did not increase but tended to saturate. When the RF power increased from 200 to 250 W, the size of the pyramidal texture structure increased from 0.45 to 0.8 ㎛. The SERS response characteristics were measured by depositing approximately 1.5 ㎛ of nanoporous Ag metal thin film through cluster sputtering on the formed texture structure by varying the RIE process conditions. The Raman signal strength of the nanoporous Ag metal thin film deposited on the Si substrate with the texture structure was higher than that deposited on the general silicon substrate by up to 19%. The Raman response characteristics were influenced by the pyramid size and the number of pyramids per unit area but appeared to be influenced more by the number of pyramids per unit area. Therefore, further studies are required in this regard.

Seasonal Variation of Kinetic and Potential Energy of Residual Flow Field in Suyoung Bay, Korea (한국수영만에서 잔차류장의 운동 .위치에너지의 계절변화)

  • 김동선;유철웅
    • Journal of Environmental Science International
    • /
    • v.6 no.4
    • /
    • pp.313-322
    • /
    • 1997
  • In order to study the seasonal variation of kinetic and potential energy of residual flow field In Suyoung Bay of Korea, we calculated Its energy budget and compared It with the tidal energy there. The potential energy shows the large value In winter and spring and the small one In summer and early autumn when the density stratification Is developed. The kinetic energy of residual flow varies seasonally and the seasonally averaged kinetic energy of residual flow per unit area is 6.4$\times$$10^{-4}ergs s^{-1}cm^{-}2$. It Is mainly governed by the density-driven current with the exception of that In November when the kinetic energy of tide-induced residual current is larger than those of density-driven current and wind-driven current. An averaged traction of the kinetic energy of tide-Induced residual current, wind-driven current and density-driven current, which are the major components of residual flow, is 29.1%, 3.4%, 67.5%, respectively, to the kinetic energy of residual flow, The fraction of kinetic energy of residual flow, potential energy and tidal energy per unit area is 1.0 : 6.7$\times$$10^3$: 8.2$\times$$10^4$ respectively.

  • PDF

Standardization of Catch per Unit Effort (CPUE) for Bigeye Tuna (Thunnus obesus) by the Korean Longline Fishery in the Pacific Ocean (한국 다랑어 연승어업에 의한 태평양해역 눈다랑어 자원의 단위노력당어획량 (CPUE)의 표준화)

  • Yoo, Joon-Taek;Hwang, Seon-Jae;An, Doo-Hae;Kim, Jong-Bin;Kim, Zang-Geun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.43 no.6
    • /
    • pp.740-746
    • /
    • 2010
  • This study standardized the catch per unit effort (CPUE) of bigeye tuna (Thunnus obesus) caught by the Korean longline fishery in the Pacific Ocean. The study used a general linear model (GLM) to standardize the CPUE using catch and effort data aggregated by year, month, and $5{\times}5$ degrees of latitude and longitude in the tropical Pacific Ocean from 1982 to 2008 (except for 1988 and 1989). Explanatory variables in the GLM analysis included year, month, subtropical area, and number of hooks between floats (HBF). The study area and HBF were subdivided into three subtropical areas and six classes, respectively. During the study period, the standardized CPUE was significantly related to the nominal CPUE. The standardized CPUE declined sharply, as compared to the nominal CPUE, after the mid 1990s. In particular, the decline in the standardized CPUE in all subtropical areas in the 2000s was clearer than that of the nominal CPUE.

Appearance Characteristic of Waterbirds in Banseok Ecological Stream (생태하천으로 조성된 반석천의 물새류 출현특성)

  • Park, Seungki;Na, Sangsoo;Park, Daesoon;Han, Jaebong
    • Journal of Korean Society of Rural Planning
    • /
    • v.26 no.1
    • /
    • pp.89-99
    • /
    • 2020
  • This study was conducted as a basic research to create a sound and vital ecological environment in the city compared to the appearance characteristics of Gap stream(G-stream), which are the main stream of Banseok stream(B-stream), by analyzing the characteristics of waterbirds, including Wild Spot-billed Duck (S-Duck), that live in B-stream built as ecological stream. The waterbird survey was conducted by the line census for 3.2km, Jukdong-bridge to Jamiseon-bridge, from January to August 2018. The analysis of the survey was conducted with Relative species density(RD) of the emerging waterbird species, the Species diversity and Density Per Unit area for 100㎡(DPU). The waterbird survey results of B-stream was conducted 65 times. The five types of water birds that appeared during the survey were Spot-billed Duck(Anas poecilorhyncha), Teal(Anas crecca), Little Egret(Egretta garzetta), Great Egret(Egretta alba), and Grey Heron(Ardea cinerea). As a result, for S-Duck at B-stream, RD was 89.9%, monthly species diversity was simple as 0.3801 in January, 0.5943 in February and 0.3501 in August. The DPU of the S-Duck was 0.165/100㎡ in the B-Stream survey section which was 4.9 times higher than the main stream section, G-stream. The non-freezing zone of the city's small stream is expected to play an important role as a winter stop for wild birds such as S-Duck during the freezing period of the huge stream. For this reason, considering the ecological characteristics of wild waterbirds such as S-Duck when creating ecological stream, a: space and linear selection of waterways which can minimize the impact of natural enemy and increasing the number of walkers, b: management water-friendly plants in the low flow channel, c: arrangement walking-bicycle road will be necessary.

Environmental Mechanism on Seeding Stage and Ripening Period in Labour Saving-Direct Sowing Rice Culture (벼 성력재배를 위한 담수직파 파종시기와 등숙환경 분석)

  • 곽태순
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.6
    • /
    • pp.541-549
    • /
    • 1992
  • Lodging and rainfalls during ripening periods and ripening patterns were studied by the different maturing varieties and different seeding dates in labour saving-direct seeding cultivation of rice. Period of emergency in earlier seeding plot was longer than later seeding plot and standing seedlings per unit area and rate of standing seedlings were more and high by the later seeding date. Number of panicles per unit area was decreased by the later seeding dates. On the other hand, the rate of effective tillers was lowest at later seeding plot. Days from seeding to flowering were shortened by the later seeding dates due to the increase of daily growth temperature and reduce of day length. There was much rainfalls during ripening period of early maturing varietal group, however not much rainfalls during ripening period of medium and late maturing varietal groups. The degree of lodging at field was severer by the amount of rainfalls during ripening period. Earlier seeding plots and earlier maturing varietal groups. of used varieties were revealed heavier lodging compared to later seeding plots and later maturing varietal groups. Yield and yield related characteristics were high and good by the earlier seeding dates, especially ripening rate was clear.

  • PDF

Growth and Carrying Capacity of Pacific Oyster, Crassostrea gigas, in Kamak Bay, Korea (가막만 양식 참굴의 성장과 환경용량 추정에 대한 연구)

  • 박영철;최광식
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.4
    • /
    • pp.378-385
    • /
    • 2002
  • Growth of Pacific oystey, Crassostrea gigas, in Kamak Bay, Korea was modeled using Von Bertalanffy growth function, seasonal Von Bertalanffy growth function and generalized growth equation of Schnute and Richards' growth model, based on shell length and wet weight frequency data of 9208 oysters. Carrying capacity in the oyster culture ground was also estimated using Schaefer's and Fox's surplus production model. The present results suggest that the generalized growth equation of Schnute and Richards' model is fitter to describe the length growth pattern of C. gigas than Von Bertalanffy growth functions. This results also suggest that the current number of culture facility per unit area in 2000 is similar to the number of facility that produces the maximum production of oyster per unit area.

A Study on the Annual Increase of Air Pollutant Emissions in Korea (대기오염물질(大氣汚染物質) 배출량(排出量)의 연도별추세(年度別趨勢)에 관(關)한 연구(硏究))

  • Cho, Moon-Whan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.9 no.1
    • /
    • pp.49-54
    • /
    • 1976
  • In order to provide bases for the control of air pollutants in Korea, the author figured out the trend on the annual increase of air pollutants emitted in the process of combustions, and estimated the amounts of air pollutants of the future years from 1975 to 1981. 1) In 1973 the consumption rate of coal was 1.2 times of that of fuel oil. The consumption rate of them would be same in 1975 and 1977. However, the rate of fuel oil would exceed that of coal in 1979. Incontrast with the rate in 1979. The one of coal would be increased faster and faster to show reverse trend of consumption in 1981. 2) The estimated amounts of air pollutant emissions in the years of 1973, 1975, 1977, 1979 ana 1981 were 1,561,800, 1,921,700, 2,253,300, 2,769,000, and 3,145,700 tons respectively. These indicated that the amount of air pollutants in 1981 would be about 2 times of that in 1973. 3) The amounts of sulfur oxides emissions in 1981 would be 2.3 times of that in 1973, nitrogen oxides 2.2 times, carbon monoxide 1.7 times, particulate 2.0 times and hydrocarbon 2.0 times. 4) The estimated amounts of air pollutant emissions per unit area($km^2$) in the years of 1965, 1971, 1975 and 1980 were 5.2, 14.5, 19.5 and 28.7 tons respectively. These indicated that the amount of air pollutant emissions per unit area would increase 5.5 times in 1980 comparing the one in 1965.

  • PDF

A Study on the Energy Performance Evaluation of Building Evaporative Cooling System for Building Construction in Response to Climate Change (기후변화 대응 저에너지 건축물 조성을 위한 건축물 기화냉각시스템 에너지성능평가 연구)

  • Kwon, Ki-Uk
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.1
    • /
    • pp.54-60
    • /
    • 2019
  • The recent climate change is exacerbating the external thermal environment and increasing the amount of energy used in building. Energy Plus was used to evaluate low energy technology performance of buildings responding to climate change. The test types of basic building(control) and evaporative mist system + basic building(EMS), and the analysis results of each type are compared. Energy performance evaluation result, Cooling peak load were EMS reduction compared to control is about 9%. Annual cooling load per unit area were EMS reduction compared to control is about 17%. Annual energy use per unit area were EMS reduction compared to control is about 10%. Therefore, the effect of the evaporative cooling system is considered to be good through energy reduction technology of building, according to the amount and distance of the evaporative mist system in the future research on building energy performance evaluation should be carried out.