• Title/Summary/Keyword: per unit area

Search Result 1,124, Processing Time 0.027 seconds

Performance Evaluation of the Wall-Type BIPV System Based on the Energy Consumption Unit - A Study for University Lecture Building - (에너지 소비 원단위를 기초로 한 벽면부착형 BIPV 시스템의 성능평가에 관한 연구 - 대학교 강의동 건축물을 대상으로 -)

  • Lee, Kang-Guk;Seo, Won-Duck;Hong, Won-Hwa
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.6
    • /
    • pp.25-32
    • /
    • 2011
  • The building integrated photovoltaic(BIPV) system has a double advantage that it reduces costs for exterior materials and PV panels. It allows the construction of a low-energy building without the need for the additional installation space. At the construction planning stage, however, it requires sufficient evaluation on the efficiency and performance. This study was performed to promote the distribution of photovoltaic power generation system by estimating the potential photovoltaic power generation capacity of the BIPV system installed on the university lecture building and by evaluating the characteristics and performances of window, spandrel and combined attachment types via the simulation of generation capacity per unit area.

  • PDF

A Study on the Process of Energy Demand Prediction of Multi-Family Housing Complex in the Urban Planning Stage (공동주택단지의 개발계획단계 시 에너지 수요예측 프로세스에 관한 연구)

  • Mun, Sun-Hye;Huh, Jung-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.304-310
    • /
    • 2008
  • Currently energy use planning council system is mandatory especially for the urban development project planned on a specified scale or more. The goal of existing demand prediction was to calculate the maximum load by multiplying energy load per unit area by building size. The result of this method may be exaggerated and has a limit in the information of period load. The paper suggests a new forecasting process based on standard unit household in order to upgrade the limit in demand prediction method of multi-family housing complex. The new process was verified by comparing actual using amount of multi-family housing complex to forecasting value of energy use plan.

  • PDF

A Scalable Structure for a Multiplier and an Inversion Unit in $GF(2^m)$

  • Lee, Chan-Ho;Lee, Jeong-Ho
    • ETRI Journal
    • /
    • v.25 no.5
    • /
    • pp.315-320
    • /
    • 2003
  • Elliptic curve cryptography (ECC) offers the highest security per bit among the known public key cryptosystems. The operation of ECC is based on the arithmetic of the finite field. This paper presents the design of a 193-bit finite field multiplier and an inversion unit based on a normal basis representation in which the inversion and the square operation units are easy to implement. This scalable multiplier can be constructed in a variable structure depending on the performance area trade-off. We implement it using Verilog HDL and a 0.35 ${\mu}m$ CMOS cell library and verify the operation by simulation.

  • PDF

Study on Evaluation Method of Thermal Potential of Unused Energy (미활용에너지의 열 포텐셜 평가 수법에 관한 연구)

  • Chung, Yong-Hyun
    • Journal of Environmental Science International
    • /
    • v.15 no.5
    • /
    • pp.493-501
    • /
    • 2006
  • The increase in environmental loads and energy consumptions has resulted in the need of developed new forms of energy for a sustainable use for the society. Recently, the viability of using unused energy has attracted a great deal of attention. From the view point of using unused energy, the most critical problem can be referred to as the distance between the heat source/sink and heat demand area. The water resource in the city water system was used to solve this distance problem with unused energy. The calculation method of the potential use unit was used to survey the potential of the water resource in the city water system. The amount of theoretical unused energy and energy savings in the model city were estimated using this method. It is estimated that the amounts of energy savings and $CO_2$ reduction correspond to 131.3 GWh and 29280[t-C], respectively, per annual basis.

Synthetic Membranes in Biotechnology: Realities and Possibilities (생물공학에서의 합성막 : 현실과 가능성)

  • Belfort, Georges
    • Membrane Journal
    • /
    • v.2 no.2
    • /
    • pp.91-103
    • /
    • 1992
  • Synthetic membrane processes are being increasingly integrated into existing reaction, isolation, and recovery schemes for the production of valuable biological molecules. In many cases they are replacing traditional unit processes. The properties of membrane systems which are most often exploited for both upstream and downstream processing and their permselectivity, high surface area per unit volume, are their potential for controlling the level of contact and/or mixing between two separate phases. Advances in both membrane materials and module design and operation have led to better control of concentration polarization and membrane fouling. After presenting some recent advances in membrane materials and fluid mechanics, we demonstrate how membranes have been integrated into cellular and enzymatic reaction schemes. This is followed by a review of established and emerging synergism between biological processes and synthetic membranes.

  • PDF

Synthetic membranes in Biotechnology: Realities and Possibilities

  • Belfort, Georges
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1992.10a
    • /
    • pp.15-33
    • /
    • 1992
  • Synthetic membrane processes are being increasingly integrated into existing reaction, isolation, and recovery schemes for the production of valuable biological molecules. In many cases they are replacing traditional unit processes. The properties of membrane systems which are most often exploited for both upstream and downstream processing are their permselectivity, high surface area per unit volume, and their potential for controlling the level of contact and/or mixing between two separate phases. Advances in both membrane materials and module design and operation have led to better control of concentration polarization and membrane fouling. After presenting some recent advances in membrane materials and fluid mechanics, we demonstrate how membranes have been integrated into cellular and enzymatic reaction schemes. This is followed by a review of established and emerging membrane separation processes. Several examples are used to emphasize the synergism between biological processes and synthetic membranes.

Air Pollutant Reduction Effect on Road Mobility in Hydrogen Economy Era (수소경제 활성화 로드맵 달성에 따른 교통 부문의 대기오염원 저감 효과 분석)

  • KIM, JUNGHWA
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.6
    • /
    • pp.522-529
    • /
    • 2020
  • This study evaluated the effect of improving the atmospheric environment based on the premise that the supply of hydrogen fuel cell vehicles (HFCV) will be achieved as many as the number of vehicles presented in the hydrogen economy activation roadmap announced by the Korean government in January 2019. The HFCV supply target (2.7 million passenger cars) suggested in the hydrogen economy revitalization roadmap was logically allocated to the five major metropolitan areas in Korea. Air pollution damage costs by region were calculated by reflecting the basic unit of damage cost to the estimated air pollutant emissions. As a result, it was confirmed that the benefits per unit of some cities in Gyeonggi-do were derived more than major cities in the metropolitan area.

Optimal Water Allocation by Dynamic Programming (동적계획법에 의한 물 배분)

  • 이순탁;이진우
    • Water for future
    • /
    • v.18 no.2
    • /
    • pp.163-174
    • /
    • 1985
  • This study aims at the development of a technique for the optimal water allocation by applying Dynamic Programming Model for the effective usage and rational allocation of water resources, in case of which limited water resources in river basin should be used in several stages. In analytical procedure the possible allocable area was firstly zoned into the four areas: Pohang area ($C_1$), Yeungcheon area ($C_2$), Gyeungsan area ($C_3$), Daegu area ($C_4$), which are located between the Yeongcheon dam and the confluence of the lower Kumho river and the main course of the Nakdong river. Secondly, a return function was determined on the basis of the correlation between the GRP in each area and the amount of water used to it. A DP Model, finally, was applied to the allocation of the water resources according to both their usage and the areas. As a result, the fact has been found that when allocating by the area, $C_1$ could be possibly supplied only with the water resources avaiable from the Yeungchon dam, and the maximum units supplied to $C_1$ should be 240 units ($1unit=10^3㎥$ per day), beyond which we ought to develop an alternative water resources. Also, the return from the allocation by the usage exceeded the one from it by the area. At the same time it was more profitable to limit the water supply to $C_1$ into 217 units. In the allocation by the area 240 units and 80 units, if only the water resources available from the Yeungcheon dam used, and 360 units and 80 units if the Doil dam used additionally, could be supplied to $C_1$ and the lower region respectively. In the allocation by the usage 103 units for industrial water with 33 units for both domestic and commercial water and 183 units, if only the water resources available from the Yeungcheon dam used, and 103 units with 33 units and 304 units, if the Doil dam taken into consideration additionally, could be supplied to $C_1$ and the lower region respectively. Therefore, much more water could be allocated to the region of lower Kumho river if the method of water allocation by the usage.

  • PDF

Drive Controller System in PM Motor with Independently Excited Winding for an Electric Bicycle (전기자전거용 독립여자권선 영구자석 전동기의 구동제어기 설계)

  • Choi, Jin-Wook;Son, Young-Dae;Kang, Gyu-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.175-177
    • /
    • 2007
  • This paper presents for the torque characteristics and improving the efficiency of driving system of electric bicycle which applied IEWPM(Independently Excited Winding Permanent Magnet) motor. IEWPM motor can expand the number of phase from 3 phases to multiphase like SRM motor because stator windings are unconnected directly. BLDC motor raise rotor'-s electromagnetic torque per unit volume by using Spoke type permanent magnet. By using two photo sensor per phase and applying excited width, advance angle and bipolar control, we confirmed higher torque at a low speed, higher out-put at a high speed, and efficiency improvement at a wide speed control area.

  • PDF

Hydrological Studies on the Comparison and the Derivation of Unit Hydrography in the small River Systems. (소하천수계의 단위유량도 유도 및 비교에 관한 수문학적 고찰)

  • 이순혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.20 no.3
    • /
    • pp.4739-4749
    • /
    • 1978
  • This studies were conducted to derive synthetic unitgraphs and triangular unitgraphs correlated with watershed characteristics which can be used to the estimation and control of flood for the rational development of Agricultural water resources. Derived Synthetic unitgraphs and Triangular unitgraphs can be applied to the ungaged watersheds were compared with average unitgraphs by observed data. Seven small watersheds were selected as studying basins Han, Geum, Nakdong, Yeongsan and Inchon river system. The results summarized for these studies are as follows: 1. Average unitgraphs by observed data and dimensionless unitgraphs for synthesis were derived for all river systems. 2. Peak discharge per unit area of the unitgraph, qp, was derived as qp=10-0.389-0.0424Lg with a high significance. 3. Formulas for the base width of unitgraph of 50 and 75 percent for peak flow for each water systems was adopted as Table 5. 4. The base length of the unitgraph, Tb, in hours in connection with time to peak, Tp, in hours was expressed as Tb =4.3Tp. 5. Peak discharge, Qp, were obtained as Table 6 by the Triangular form to all subwatersheds. 6. Relative errors in the peak discharge of the synthetic unitgraphs showed to be 7.3 percent to the peak of observed average unitgraphs except errors of peak discharge for Yeongsan river system. This indicates that Synthetic unitgraphs for the small watersheds of Han, Geum, Nakdong and Inchon river systems can be applied to the ungaged watersheds. On the other hand, It was confirmed that the accuracy of Instantaneous Unit Hydrograph with only 1.6 percent as relative errors was approaching more closely to the observed average unitgraph than that of synthetic unitgraph with relative errors. 23.9 percent for Yeongsan river system. 7. Errors in the peak discharge of the triangular unitgraph to the observed average unitgraph showed to be 0.6 percent to 7.5 percent which can be regarded as a high precision within the range of 200 to 500$\textrm{km}^2$ in area. On the contrary, application of triangular unitgraph within the range of 200$\textrm{km}^2$ in area has defined as a unsuitable method because of high relative errors, 26.4 percent to 61.6 percent.

  • PDF