• Title/Summary/Keyword: penetration resistance test

Search Result 408, Processing Time 0.028 seconds

Mechanical Properties And Chlorde Penetration Resistance of Shotcrete according to Mineral Admixture Types and Supplemental Ratio (광물성 혼화재료의 종류 및 혼입율에 따른 숏크리트의 역학적 특성 및 염해 저항성)

  • Han, Seung-Yeon;Yun, Kyong-Ku;Nam, Kyeong-Gung;Lee, Kyeo-Re;Eum, Young-Do
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4960-4968
    • /
    • 2015
  • In this study to improve the chloride durability of the shotcrete structure depending on types and contents of mineral admixture chloride resistance was evaluated by NT BUILD 492 of european test standards. It was also evaluated with the mechanical properties such as static strength and chloride penetration resistance. For shotcrete mixed crushed stone aggregate of the maximum size 10mm of coarse aggregates was produced. Based on 28days compression strength the variable mixed with 15% silica fume showed the highest strength in 67.55MPa. As the content of fly ash and blast furnace slag increased, the strength lowered. In the chloride penetration resistance test, OPC showed "high grade" and In the case of admixture, the penetration resistance tended to increase in all variables except the fly ash. In order to evaluate the service life, the accelerated chloride penetration test was conducted by the standards of KCL, ACI, FIB. Test results were obtained with the lowest spreading factor in a variable mixed with silica fume of 15%. At the KCI standards, It was found to have a service life of about 65 years and at the FIB standards, It was found to have a service life of 131 years. Among standards, the service life of KCI standard in all of the variables was evaluated as the lowest.

Heat Transfer Characteristics of Bulkhead Penetration Piece for A60 Class Compartment I: Transient Thermal (A60급 구획 적용 격벽 관통용 관의 열전달 특성 I: 관의 설계에 따른 과도 열해석)

  • Park, Woo-Chang;Song, Chang Yong;Na, Ok-Gyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.310-323
    • /
    • 2018
  • In order to protect lives and prevent large-scale injuries in the event of a fire on a ship or an offshore plant, most classification societies are strengthening their fire resistance designs of relevant cargo holds and accommodation compartments to keep flames from being transferred from a fire point to other compartments. Particularly in critical compartments, where flames should not propagate for a certain period of time, such as the A60 class division, both the airtightness and fire-resistant design of a piece passing through a bulkhead are subject to the Safety of Life at Sea Convention (SOLAS) issued by the International Maritime Organization (IMO). In order to verify the suitability of a fire-resistant design for such a penetrating piece, the fire test procedure prescribed by the Maritime Safety Committee (MSC) must be carried out. However, a numerical simulation should first be conducted to minimize the time and cost of the fire resistance test. In this study, transient thermal analyses based on the finite element method were applied to investigate the heat transfer characteristics of a bulkhead penetration piece for the A60 class compartment. In order to determine a rational bulkhead penetration piece design, the transient heat transfer characteristics according to the variation of design parameters such as the diameter, length, and material were reviewed. The verification of the design specification based on a numerical analysis of the transient heat transfer performed in this study will be discussed in the following research paper for the actual fire protection test of the A60 class bulkhead penetration piece.

A Study on the Root-Resistance Performance of PET film Sheet applied by FRP Coating material (PET 필름 내근시트와 FRP 도막층이 일체화된 방수·방근층의 방근성능에 관한 연구)

  • Kwon, Young-Hwa;Park, Jin-Sang;Kim, Dong-Bum;Park, Wan-Goo;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.253-254
    • /
    • 2018
  • In the construction industry, a variety of Root-Resistance Waterproofing Sheets ar being developed and studied. However, defects still occur in the sheet. In this study, the performance of the navigation is studied by Root-Resistance. As a result of the test, no piercing or penetration marks were found by root in all the specimens.

  • PDF

Estimation of Deformation Modulus of Cemented Sand using CPT and DMT (CPT와 DMT를 이용한 고결모래의 변형계수 추정)

  • Lee, Moon-Joo;Choi, Sung-Kun;Hong, Sung-Jin;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.484-491
    • /
    • 2008
  • The purpose of this study is to compare the cementation effect on cone resistance and DMT indices and to evaluate the deformation characteristic of cemented sand using cone resistance and dilatometer modulus. Specimens of various relative densities with three different cementation levels are prepared in a large calibration chamber under different vertical stress levels. Test result shows that the cone resistance and dilatometer modulus underestimate the deformation modulus of cemented sand, since in situ penetration tests such as CPT and DMT damage the cementation bonds during penetration. By regression analysis, the constrained modulus of cemented sand is related with the cone resistance and the dilatometer modulus.

  • PDF

Mechanical and Durability Characteristics of Latex-Modified Concrete Using Ultra Rapid Hardening Cement (초속경 시멘트를 이용한 라텍스 개질 콘크리트의 역학성능과 내구성능)

  • Park, Sang-Hyun;Jung, Si-young;Kim, Hyun-yu;Choi, Kyoung-Kyu
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.5
    • /
    • pp.153-160
    • /
    • 2019
  • The purpose of this study was to investigate the mechanical and durability characteristics of latex-modified concrete using ultra rapid hardening cement : four types of mechanical tests including compressive strength, modulus of elasticity, flexural strength and bond strength were performed; and seven types of durability tests including resistance of concrete to chloride ion penetration, freeze-thaw resistance, scaling resistance, coefficient of thermal expansion, cracking tendency, abrasion resistance and drying shrinkage were performed. Required material performance of each test was determined in accordance with the Korea specification for repair of concrete and pavement repairing materials. The test results satisfied the required material performances, and presented a good mechanical and durability characteristics. In particularly, the materials showed early development of compressive strength, flexural strength and bond strength at 3 and 4 hours after curing. SEM photos were also taken to investigate the micro structures of the materials after chloride ion penetration test.

Estimation of compressibility for Busan clay by CPT (CPT를 이용한 부산점토의 압축특성에 관한 연구)

  • Hong, Sung-Jin;Lee, Moon-Joo;Shim, Seong-Hyeon;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.320-325
    • /
    • 2009
  • The constrained modulus, representative property to evaluate compressibility of soil, is needed to estimate the settlement of ground structure. A series of lab and field cone penetration tests for clayey soil of Busan new-port and Noksan industrial area were conducted to evaluate the estimation method of constrained modulus. Since CPT generates large deformation of ground, it is difficult to correlate the cone resistance with the constrained modulus. Therefore, appropriate correlation between them is essential to estimate the constrained modulus based on CPT results. The test results show that the ratio of the constrained modulus to the cone resistance is inversely proportional with plasticity index. Based on this result, the estimation method of constrained modulus for Busan clay is suggested.

  • PDF

Influence of supplementary cementitious materials on strength and durability characteristics of concrete

  • Praveen Kumar, V.V.;Ravi Prasad, D.
    • Advances in concrete construction
    • /
    • v.7 no.2
    • /
    • pp.75-85
    • /
    • 2019
  • The present study is focused on the mechanical and durability properties of ternary blended cement concrete mix of different grades 30 MPa, 50 MPa and 70 MPa. Three mineral admixtures (fly ash, silica fume and lime sludge) were used as a partial replacement of cement in the preparation of blended concrete mix. The durability of ternary blended cement concrete mix was studied by exposing it to acids HCl and $H_2SO_4$ at 5% concentration. Acid mass loss factors (AMLF), acid strength loss factor (ASLF) and acid durability factor (ADF) were determined, and the results were compared with the control mix. Chloride ions penetration was investigated by conducting rapid chlorination penetration test and accelerated corrosion penetration test on control mix and ternary blended cement concrete. From the results, it was evident that the usage of these mineral admixtures is having a beneficiary role on the strength as well as durability properties. The results inferred that the utilization of these materials as a partial replacement of cement have significantly enhanced the compressive strength of blended concrete mix in 30 MPa, 50 MPa and 70 MPa by 42.95%, 32.48% and 22.79%. The blended concrete mix shown greater resistance to acid attack compared to control mix concrete. Chloride ion ingress of the blended cement concrete mix was low compared to control mix implying the beneficiary role of mineral admixtures.

A Study on the Correlation between Standard Penetration Resistance Value and Static Cone Penetration Resistance Value of the Soft Ground Subsurface of Yongdong Area (표준관입저항치와 정적콘관입저항치의 상관성에 관한 연구 - 영동지역의 연약지반을 중심으로 -)

  • Kim, Jinam;Park, Heunggyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.5
    • /
    • pp.13-20
    • /
    • 2006
  • We have conducted standard penetration tests and static cone penetration tests that are widely used the land base examination on the soft ground subsurface of Yongdong area, and examined the correlation between them. We have also made a comparative analysis of the correlation between the indoor tests on the materials collected on the site and on-the-spot penetration tests. The results are as follows : The relationship between Standard Penetration Test N-value and Dutch Cone Tset show $Q_c=1.93N+0.29$ for organic soil, $Q_c=2.19N+0.20$ for clay, $Q_c=2.34N+1.06$ for silt, $Q_c=3.02N+0.54$ for silty sand, and $Q_c=3.47N+0.46$ for sand. In this case of sand $Q_c/N$ increases when the soil particles are larger. The relationship between standard penetration test N-value and Unconfined Compression Strength $q_u$ show $q_u=0.11N+0.03$ for organic soil, $q_u=0.11N+0.25$ for clay, and $q_u=0.18N-0.03$ for silt.

  • PDF

The Analysis of Chloride Penetration at Concrete and Repair Material under Tidal and Splash Zone (조간대와 비말대의 콘크리트와 보수재의 염분침투 특성분석)

  • Lee, Joon-Gu;Cho, Young-Kwoun;Kim, Meyong-Won;Kim, Kwan-Ho;Joo, Jae-Hong;Kim, Han-Joung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.207-208
    • /
    • 2010
  • The building that supply tidal and splash zone was constructed near Seamangeum Gate Bridge. The specimens that will be tested for maintenance of gate bridge were exposed on the tidal and splash zone, totally about 650. The characteristics of strength, salt penetration profile, field application of surface repair material and section recover material will be acquired by periodical test. The program was developed to obtain optimal maintenance strategy of gate bridge as a marine concrete structure and to deposit experimental data, lab. test result, field test result, on its D/B. On this paper, the comparison of concrete and recover material in the salt penetration characteristics was expressed. The quantitative analysis of salt contents in concrete surface was most important so the improvement for the machine of gathering power of concrete and the apparatus of measuring chloride contents was proceeded at this time. The two conclusions were summarized like as - The resistance of chloride attack of concrete was appeared 2.5 times bigger than that of recover material - The resistance of chloride attack of polymer series was appeared more higher than that of others.

  • PDF

The Field Application of Miniature Cone Penetration Test System in Korea (소형콘관입시험(Miniature Cone Penetration Test)의 국내현장 적용)

  • Yoon, Sung-Soo;Ji, Wan-Goo;Kim, Jun-Ou;Kim, Rae-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.349-360
    • /
    • 2009
  • The cone penetration test(CPT) has gained its popularity in site characterization indebted by its reliability, speed, economy, and automatic measurement system since its development in the 1930s. The CPT results, commonly consisting of cone tip resistance, sleeve friction, and pore water pressure measurements, allow us to classify soils as well as to reveal their engineering characteristics. The site condition at which the CPT is allowable is often dependent on the capacity of a CPT system. In Korea, it has been considered that the CPT could be appled only to soft soils in most cases because CPT systems available for stiff soils are very rare due to their expensive procurement and maintenance cost. Luoisiana Transportation Research Center(LTRC) has developed and implemented a field-rugged continuous intrusion miniature cone penetration test(CIMCPT) system since the late 1990s. The miniature cone penetrometer has a sectional cone area of $2cm^2$ allowing system capacity reduction compared to the standard $10cm^2$ cone penetrometer. The continuous intrusion mechanism allows fast and economic site investigation. Samsung Engineering & Construction has recently developed and implemented a similar CIMCPT system based on its original version developed in LTRC. The performance of the Samsung CIMCPT system has been investigated by calibration with the standard CPT system at a well-characterized test site in Pusan, Korea. In addition, scale effect between the miniature cone penetrometer and the standard cone penetrometer has been investigated by comparing the field test results using the both systems.

  • PDF