• Title/Summary/Keyword: penetration resistance test

Search Result 408, Processing Time 0.036 seconds

Influence of Mineral Admixtures on the Diffusion Coefficient for Chloride Ion in Concrete (광물질 혼화재가 콘크리트의 염소이온 확산계수에 미치는 영향)

  • Bae, Su-Ho;Park, Jae-Im;Lee, Kwang-Myong;Choi, Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.347-353
    • /
    • 2009
  • The qualitative factors influencing the ingress of chloride ion into concrete are water-binder (W/B) ratio, cement type, age, chloride ion concentration of given environment, wet and dry conditions, etc. Thus, an objective of this experimental research is to investigate the effects of cement types and environmental conditions on the chloride ion diffusion characteristics in concrete through the chloride ion diffusion test. For this purpose, the diffusion coefficients for chloride ion in concrete with three types of cement such as ordinary portland cement (OPC), binary blended cement (BBC), and ternary blended cement (TBC), were measured for the concrete specimens with W/B ratios of 32%, 38%, and 43%, respectively. The diffusion coefficients for chloride ion were also measured for the concrete specimens with W/B ratio of 43%, which were subjected to standard curing and field exposure conditions. It was observed from the test results that the resistance against chloride ion penetration increased with decreasing W/B ratio and those of BBC and TBC concretes were greater than that of OPC concrete. Therefore, it was revealed that the use of these cements containing mineral admixtures is required to extend the service life of RC structures exposed to chloride environment. On the other hand, it was noted that the resistance against chloride ion penetration of field exposure test specimens was slightly lower than that of standard curing test specimens due to the penetration of chloride ion under the irregular ambient temperature, splash of wave, and cycle of wet and dry.

Chloride Diffusion in Mortars - Effect of the Use of Limestone Sand Part II: Immersion Test

  • Akrout, Khaoula;Ltifi, Mounir;Ouezdou, Mongi Ben
    • International Journal of Concrete Structures and Materials
    • /
    • v.4 no.2
    • /
    • pp.109-112
    • /
    • 2010
  • Part I of this study was devoted to the electrical accelerated chloride diffusion in mortars. In this second part, natural chloride diffusion has been investigated for four types of mortars under exposure to a 0.5 mol/L NaCl solution for a period of up to 35 days. Two different types of sand were used for the production of test samples: siliceous sand (used as a reference) and limestone sand (used in this study). The effect of water to cement ratio and exposure time on the diffusion coefficients of mortars was also investigated. In this study, the total and free chloride content and penetration depth of mortar were measured after immersion, and Fick's second law of diffusion was fitted to the experimental data to determine the diffusion coefficient. Their results show that the use of crushed limestone sand in mortar had a positive effect on the chloride resistance. The apparent diffusion coefficient in all specimens was smaller than that in siliceous sand mortar. However, the chloride penetration of these mortars was increased as exposure time progressed.

Enhancement of the Technique for Analyzing a Pile Driven by Vibro Hammer (진동해머에 의해 시공되는 말뚝의 해석기법 제고)

  • Lee, Seung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3596-3601
    • /
    • 2015
  • Enhancement of the existing program for analyzing a pile driven by vibro hammer was tried. Damping effect of dynamic soil resistance and clutch friction were added to the existing governing equation which constitute vibrating system of vibro hammer-pile-soil. Parameters of the modified Ramberg-Osgood model which simulates dynamic load transfer curves for the developed program were recomputed. Comparing the results of the modified program with those of the field tests, pile displacement with time and load transfer behavior were more similar to those of the field test. The penetration rates obtained from the modified program were more close to those of the field test rather than those of the commertical program.

An Experimental Study on the Stability of Open-ended Pipe Piles Installed in Deep Sea during the Simulated Seaquake (해진시 심해에 설치된 개단말뚝의 안정성에 관한 모형실험 연구)

  • 남문석;최용규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.3
    • /
    • pp.45-54
    • /
    • 1999
  • It is known from the previous study on the behavior of sharter single pile during simulated seaquake induced by the vertical component of earthquake that the compressive capacity and the soil plugging resistance of single open-ended pipe pile were completely degraded. But, the capacity of single open-ended pipe pile with greater penetration and the capacity of piles group with shorter penetration were expected to be stable after seaquake motion. In this study, first single pile, 2-pile or 4-pile groups with several simulated penetrations were driven into the calibration chamber with saturated fine medium sand and the compressive load test for each installed pile or pile groups was performed. Then, about 95% compressive load of the ultimate capacity was applied on the pile head during the simulated seaquake motion. Finally, to confirm the reduction of pile capacity during the simulated seaquake motion, the compressive load test for each single pile or pile groups after seaquake motion was performed. During the simulated seaquake, compressive capacities of single open-ended pipe pile and piles group installed in shallow sea were not decreased. But, the stability of open-ended pile installed in deep sea was depended on the pile penetration depth. So, single open-ended pile with greater penetration of 27 m was stable, and 2-pile and 4-pile groups with penetration more than 13m were stable. But, 2-pile groups with penetration of 7m was failed, and the compressive capacity of 4-pile groups with penetration of 7m was degraded about 15%.

  • PDF

An experimental study on durability evaluation of the concrete applied nano level inorganic polymer based coatings (나노합성 무기질 폴리머계 표면처리제를 적용한 콘크리트의 내구성능 평가에 관한 실험적 연구)

  • Baek Jong-Myeong;Kim Eun-Kyeum
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1014-1020
    • /
    • 2004
  • In this study, durability of the nano-level inorganic polymer based coatings which can provide a barrier against the ingress of moisture or aggressive ions to concrete is discussed. For the durability evaluation of the coatings, chloride penetration test, accelerating carbonation test, freezing and thawing test, and sulfate ponding test are conducted. As the result of this study, concrete applied nano-level inorganic polymer based coatings has a much higher resistance to the ingress of chloride ion, carbon dioxide, moisture and aggressive acid than plain concrete and epoxy resin based paint by means of crosslinking three-dimensional structure with concrete structure.

  • PDF

Evaluation of Chloride Ion Penetration Resistance of High Calcium Silicate Cement Concrete (High Sulfated Calcium Silicate 시멘트 콘크리트의 염소이온침투저항성 평가)

  • Jeong, Seok-Man;Yang, Wan-hee;Kim, Hyeon-Soo;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.35-43
    • /
    • 2022
  • The aim of this work was to a comparative review the performance of high calcium silicate cement (HSCSC) and that of ordinary Portland cement(OPC) and blast furnace slag cement(S/C). The result of the compressive test confirmed that the compressive strength development rate of high calcium silicate cement concrete at the age of 3 days was 73.6% that of ordinary Portland cement concrete. However, at the age of 28 days, the strength development rate of high calcium silicate cement increased to about 107.0% compared to ordinary Portland cement. In addition, the test of the chloride ion penetration resistance of concrete showed that at the age of 28 days, the passed charge decreased by 73.4% and 93.0%, respectively, in blast furnace slag cement and high calcium silicate cement compared to ordinary Portland cement, and at the age of 56 days, it decreased by 79.1% and 98.3%, exhibiting excellent resistance to chloride ion penetration. In particular, it was confirmed that the rate of decrease in the passed charge with age was higher in high calcium silicate cement than in ordinary Portland cement and blast furnace slag cement.

Evaluation of Piezocone Coefficient of Soft Grounds in the Areas of Gyeonggi and Incheon (경인지역 연약지반의 피에조콘계수 평가)

  • Park, Soo-Yong;Kim, Ki-Beom;Lee, Yun-Kyu;Baek, Seung-Cheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.5
    • /
    • pp.41-49
    • /
    • 2012
  • In this study, laboratory test, in-situ vane shear test and piezocone penetration test in the study area were conducted to investigate the engineering characteristics of soft soils at Cheongra District, Songdo District in Incheon City, the west coast of Gyeonggi province, and Sihwa District in Ansan city. The correlations among compression index, and in-situ vane shear test, and cone resistance were obtained. The variations of liquid limit, plasticity index, water content and compression index with respect to depth exhibit strong similarity. This means that they have strong correlations, which can be used to evaluate the local characteristics of the study area. Thus, the correlations between compression index and physical properties were analysed to investigate the engineering characteristics of soft soil in the study area. The relationships between the measured piezocone factor by empirical methods, and undrained shear strength obtained by triaxial compression test or in-situ vane shear test were compared. It shows the significant correlation and piezocone factors, $N_{kT}$are suggested for the study area.

Porosity estimation using electrical resistance Cone Probe in offshore soils (전기저항 콘 프로브를 이용한 해안지반의 간극률 산정)

  • Lee, Jong-Sub;Kim, Joon-Han;Yoon, Hyung-Koo;Cho, Tae-Hyeon;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.127-133
    • /
    • 2008
  • The electrical resistivity methods have been commonly used for figuring out the ground layers. The purpose of this paper, differently from previous methods, is not only to figure out the layers but also to develope a equipment and a method to analyze ground porosity. Equipment has a shape of cone, which can be coupled with drilling rods. A field penetration test was performed to test application in Incheon Chungla area. Through the field test soil resistances were measured. To calculate soil porosity along the depth, Archie's law is applied. The results show that a new equipment and porosity analysis method using Archie's law can distinguish soil layers and precisely measure soil porosity.

  • PDF

Analyses on Environment-friendliness of Root Barrier Materials based on Fish Toxicity Test (어독성 실험에 따른 방근재 친환경 특성 분석)

  • Woo, Ji-Keun;Kim, Sung-Kyun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.4
    • /
    • pp.42-51
    • /
    • 2010
  • The purpose of this study is to analyze the characteristics of environment-friendliness of Root Barrier materials based on comprehensive experiments on harmfulness of Root Barrier materials and fish toxicity of Oryzias latipes mortality to verify eco-toxicity of each method of construction and Root Barrier material, which are to be applied by taking eco-toxicity into account when building ecological flows in upper areas on natural and artificial grounds. As a result, the following conclusions have been reached in this study: 1. In regard of the harmfulness analyzed, each material showed a different result of analytical value in each lab tank. Compared to lab tank, pH (la), DO (lb), T-N (VI) and T-coli (la) were in the same grade, but COD, SS, T-P and F-coli were less than that of control, respectively increased or decreased by material were analyzed. 2. In the experiment of fish toxicity, Barrier sheet was found to have 66.7% of fish mortality, indicating strong fish toxicity. Synthetic rubber system root barrier sheet (20.0%) was analyzed to have medium fish toxicity, while Synthetic resin system root barrier-waterproof sheet (3.3%), Synthetic rubber system membrane root barrier sheet (3.3%) and Synthetic resin system root barrier sheet (0.0%) showed relatively lower mortality and fish toxicity. To sum up such results as found in the experiment mentioned so far, the values of harmfulness and root penetration resistance analyzed were different in each lab tank, but there was absolutely little correlation with the mortality gained from the experiment on fish toxicity. In the experiment of fish toxicity, environment-friendly root barrier materials were analyzed, and it was found that Synthetic resin system root barrier sheet, Synthetic resin system root barrier waterproof sheet and Synthetic rubber system membrane root barrier sheet are highly environment-friendly. In contrast, Synthetic rubber system root barrier sheet was found to have medium-level environment-friendliness. Also, Barrier sheet was analyzed to have low environment-friendliness.

Resistance to Root Penetration of Root Barrier for Green Roof System (옥상녹화용 방근층 구성재료의 방근성능에 관한 실험적 연구)

  • Kim, Hyun-Soo;Jang, Dae-Hee;Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.6
    • /
    • pp.123-129
    • /
    • 2008
  • The purpose of this study is to test performances of 14 types of root barrier materials by applying testing plant: and soils suitable for weather and natural features of Korea. For testing Plants, Plioblastus pygmaed Mitford A and Pyracantha angustifolia have been selected. For testing soil, mixture of pearlite and peat moss in 3:1 ratio Testing container has been fabricated with duplicated structure having inner and outer containers. And the outer container has 2 hinges on its side wall to allow opening and closing. Wet rock wool with 50mm in thickness has been inserted between inner and outer containers to allow root to penetrate through root barrier material and continue to grow. We planted 12 Plioblastus pygmaed Mitford A. and 4 Pyracantha angustifolia per one testing container. Three testing samples have been made for 1 type of root barrier material, which become a total 42 specimens. Planted testing samples have been installed within the greenhouse, which will be observed regularly for 2 years from now on. We started test from July 11, 2008 and had performed intermediate observations every month for initial 3 months. From the 3rd intermediate observation on Sept. 18, we confirmed that 6 types of roe barrier materials have penetrated roots. Even though two types of them have been generally used as root barrier materials for roof planting system, all of three testing samples have a lot of penetrated roots. This result proves that it is not reasonable to introduce testing methods of root barrier from Europe. USA or Japan.