• Title/Summary/Keyword: penetrating

Search Result 999, Processing Time 0.03 seconds

An Experimental Study on the Basic Properties of Penetrating repair material using Silicate-based Inorganic Materials (규산염계 무기 재료를 활용한 침투성 보수재의 기초 특성에 관한 실험적 연구)

  • Ha, Sang-Woo;Oh, Sung-Rok;Choi, Yung-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.39-45
    • /
    • 2017
  • In this study, permeable repair materials mainly composed of silicate - based inorganic materials(SIM), which are easily available domestically, were prepared as a basic study for the development of permeable repair materials using SIM. SIM were compared and examined for their performance as repair materials by selecting a product group which has many cases of use in foreign countries. The SIM used were mainly composed of sodium, potassium and lithium silicate. Performance evaluation of SIM was performed by absorption and penetration, compression and adhesion, rapid chloride ion penetration, rapid freezing and thawing, and chemical resistance test. According to the test results, SIM showed effective performance in all areas, mainly because SIM permeates into the interior of the capillary and has a dense internal microstructure. Therefore, it can be used variously to improve the durability of concrete based on the results of this experiment.

Clinical Observations of the Chest Trauma (흉부 손상에 대한 임상적 고찰)

  • 최명석
    • Journal of Chest Surgery
    • /
    • v.23 no.5
    • /
    • pp.905-915
    • /
    • 1990
  • A clinical evaluation was performed on 545 cases of the chest trauma those had been admitted and treated at the department of thoracic and cardiovascular surgery in Chosun University Hospital during the past 11 years 5 months period from January 1978 to may 1989. Obtained results were as follows: 1. The ratio of male to female was 3.9: 1 in male predominance, and the majority[66.6%] was distributed from 3rd to 5th decade. 2. Nonpenetrating chest trauma was more common than penetrating about 4.6 times, and the most common cause of the nonpenetrating injuries was traffic accident[241/448, 53.8%] and of the penetrating injuries was stab wound[88/97, 90.7%]. 3. Only 79 cases[14.5%] were arrived to our emergency room within one hour after trauma. 4. The most common lesion due to trauma among these admitted patients was rib fracture[390/545, 71.6%], and the others were lung contusion[217/545, 39.8%], hemothorax[35%], hemopneumothorax[19.6%], and pneumothorax[11.8%] et al in decreasing order. 5. The associated injuries those required special treatment of other departments were 223 cases and its distributions were bone fractures[178/545, 32.7%], head injury[5.3%], and abdominal injury[6.6%]. 6. The others, but interesting chest injuries were follows: sternum fracture[3.1%], diaphragm rupture[2.6%], myocardial laceration and rupture[2 cases], bronchial rupture and laceration[2 cases], and traumatic thymoma rupture[1 case]. 7. The incidence of flail chest was 5.8%a[26/448] in the nonpenetrating injury, and the causes were multiple rib fracture which was in rows more than 4 rib fracture[20 cases], and sternum fracture[6 cases]. 8. We could managed the most of the patient with conservative treatment[43.1%] or closed tube thoracostomy[52.7%], but required emergency open thoracotomy in 64 cases

  • PDF

Microvascular Anastomosis with Non-penetrating Vascular Clips in Head and Neck Free Flap Surgery (두경부 유리피판 수술에 있어서의 비천공성 혈관 클립을 이용한 미세혈관 문합술)

  • Chang, Hak;Minn, Kyung-Won;Kim, Woo-Ram;Shin, Hyun-Woo;Koh, Kyung-Suck
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.57-62
    • /
    • 2005
  • Microvascular anastomosis with suture technique is a basic skill but there are several problems such as stenosis, thrombosis and long operating time. Recently plastic surgeons have developed non-suturing mechanical coupling devices for microvascular anastomosis. The authors applied non-penetrating vascular clips (VCS clips) in the field of free flap surgery of head and neck area. Between August of 2004 and January of 2005, we performed 9 free flaps (16 vessels) using small-sized VCS clips. Four stay sutures were applied first and then VCS clips were placed between sutures about 1 mm apart. Vascular pedicle of free flap included the descending branch of lateral circumflex femoral vessel, thoracodorsal vessel, deep inferior epigastric vessel and cephalic vein. The recipient vessels were the superior thyroid artery, superficial temporal artery, internal jugular vein, external jugular vein, and superficial temporal vein. We performed 13 end-to-end (4 arteries and 9 veins) and 3 venous end-to-side anastomoses. No flap related complication occurred but we applied additional clips or sutures in two cases due to blood leakage after completion of anastomosis. Primary patency rates seemed to be good and more rapid anastomosis could be done than conventional suture technique. Advantages of VCS technique are high patency rate, low thrombogenecity and rapidity. Although the high cost of VCS instrument may be a problem, this clip could be applied safely in microvascular free tissue transfer.

  • PDF

A comparison study of acupuncture sensation scale between real acupuncture and sham needle (거짓침 피부접촉부 형태에 따른 침감 차이 연구)

  • Chae Youn-Byoung;Kim Yun-Ju;Choe Il-Hwan;Lim Sabina;Lee Sang-Jae;Lee Hye-Jung;Park Hi-Joon
    • Korean Journal of Acupuncture
    • /
    • v.23 no.4
    • /
    • pp.85-99
    • /
    • 2006
  • Objectives : Proper acupuncture stimulation is associated with a characteristic set of sensation usually referred to as 'De-Qi'. In order to develop the appropriate sham acupuncture, various sensations to each stimulation should be considered through analysis of the profiles of acupuncture sensation. It was therefore investigated to compare the acupuncture sensation scale (ASS) of two types of sham acupuncture to that of the real acupuncture. Methods : Ninety-four participants (mean age 26.4, range 26-49) were asked to complete five point-Likert scale ASS developed by Vincent et al. after real or two-kinds of sham acupuncture stimulation: blunted tip sham acupuncture (BT) and round tip sham acupuncture (RT). Needling was done at LI4 acupoint on non-dominant hand and stimulated for 30 seconds with real or two-kinds of sham needle. Finger withdrawal latency (FWL) of each group was also measured to evaluate the pain sensitivity to noxious heat stimuli. Results : BT acupuncture significantly less produced penetrating, numb, intense, hurting, pulling, shock, tingling, throbbing sensation than real acupuncture stimulation. RT acupuncture significantly less produced penetrating, burning, electric, numb, intense, hurting, pulling, aching, shasharp, shock, stinging, tingling, throbbing sensation than real acupuncture. Each group did not demonstrate the differences of pain sensitivity to noxious stimuli. Conclusions : These results indicated that types of tip of acupuncture produced different kinds of acupuncture sensation. Our finding provides a general information of sensations to two kinds of sham acupuncture for development of ideal placebo sham needle.

  • PDF

A Study on the Selection of GPR Type Suitable for Road Cavity Detection (도로동공 탐지에 적합한 GPR 타입 선정에 관한 연구)

  • Kim, Yeon Tae;Choi, Ji Young;Kim, Ki Deok;Park, Hee Mun
    • International Journal of Highway Engineering
    • /
    • v.19 no.5
    • /
    • pp.69-75
    • /
    • 2017
  • PURPOSES : The purpose of this study is to evaluate different types of Ground Penetrating Radar (GPR) testing for characterizing the road cavity detection. The impulse and step-frequency-type GPR tests were conducted on a full-scale testbed with an artificial void installation. After analyzing the response signals of GPR tests for detecting the road cavity, the characteristics of each GPR response was evaluated for a suitable selection of GPR tests. METHODS : Two different types of GPR tests were performed to estimate the limitation and accuracy for detecting the cavities underneath the asphalt pavement. The GPR signal responses were obtained from the testbed with different cavity sizes and depths. The detection limitation was identified by a signal penetration depth at a given cavity for impulse and step-frequency-type GPR testing. The unique signal characteristics was also observed at cavity sections. RESULTS : The impulse-type GPR detected the 500-mm length of cavity at a depth of 1.0 m, and the step-frequency-type GPR detected the cavity up to 1.5 m. This indicates that the detection capacity of the step-frequency type is better than the impulse type. The step-frequency GPR testing also can reflect the howling phenomena that can more accurately determine the cavity. CONCLUSIONS :It is found from this study that the step-frequency GPR testing is more suitable for the road cavity detection of asphalt pavement. The use of step-frequency GPR testing shows a distinct image at the cavity occurrences.

Emergency Surgical Management of Traumatic Cardiac Injury in Single Institution for Three Years

  • Joo, Seok;Ma, Dae Sung;Jeon, Yang Bin;Hyun, Sung Youl
    • Journal of Trauma and Injury
    • /
    • v.30 no.4
    • /
    • pp.166-172
    • /
    • 2017
  • Purpose: Thoracic traumas represent 10-15% of all traumas and are responsible for 25% of all trauma mortalities. Traumatic cardiac injury (TCI) is one of the major causes of death in trauma patients, rarely present in living patients who are transferred to the hospital. TCI is a challenge for trauma surgeons as it provides a short therapeutic window and the management is often dictated by the underlying mechanism and hemodynamic status. This study is to describe our experiences about emergency cardiac surgery in TCI. Methods: This is a retrospective clinical analysis of patients who had undergone emergency cardiac surgery in our trauma center from January 2014 to December 2016. Demographics, physiologic data, mechanism of injuries, the timing of surgical interventions, surgical approaches and outcomes were reviewed. Results: The number of trauma patients who arrived at our hospital during the study period was 9,501. Among them, 884 had chest injuries, 434 patients were evaluated to have over 3 abbreviated injury scale (AIS) about the chest. Cardiac surgeries were performed in 18 patients, and 13 (72.2%) of them were male. The median age was 47.0 years (quartiles 35.0, 55.3). Eleven patients (61.1%) had penetrating traumas. Prehospital cardiopulmonary resuscitations (CPR) were performed in 4 patients (22.2%). All of them had undergone emergency department thoracotomy (EDT), and they were transferred to the operating room for definitive repair of the cardiac injury, but all of them expired in the intensive care unit. Most commonly performed surgical incision was median sternotomy (n=13, 72.2%). The majority site of injury was right ventricle (n=11, 61.1%). The mortality rate was 22.2% (n=4). Conclusions: This study suggests that penetrating cardiac injuries are more often than blunt cardiac injury in TCI, and the majority site of injury is right ventricle. Also, it suggests prehospital CPR and EDT are significantly responsible for high mortality in TCI.

Distribution Pattern and Functional Characteristics of Shop-house in the 2nd Class General Residential Zone in Seoul - A Case Study of Seokchon, Yangjae, Dunchon, and Sagajeong Districts - (서울시 제2종일반주거지역 내 상업기능주택의 배치와 기능적 특성 - 석촌, 양재, 둔촌, 사가정 사례 분석 -)

  • Yang, Woohyun;Kim, Sung-Eun
    • Journal of the Korean housing association
    • /
    • v.24 no.5
    • /
    • pp.57-67
    • /
    • 2013
  • The purpose of this study is to find out distributional principles of the shop-houses in residential district through physical composition of residential area. Through the research that are based on literature and field survey, it analysed the relation between physical composition of residential area and the shop-houses of selected four sites under similar urban condition where land readjustment project were held. The consequences of this study are summarized as follows; 1) A road that is not penetrating the inside a residential area is seemed to have low occupancy of shops comparing to other roads with similar hierarchy. And the shops functions as convenience facilities. It can be inferred from the statement above that even a road with higher hierarchy is not easy to form commercial area if without penetrating the residential area. 2) According to the size and the arranged method of Inner blocks of residential area towards major roads, distribution of shop-houses appear to be different. In other words, when shop-houses are located along the roads, the proportion of shop was higher than when located perpendicular to the roads. 3) When the number of average lots are little and the size of block is small, usually, street ratio and the number of corners gets higher, which eventually increases the number of shop-houses.

Wooden Foreign Body in the Parotid Gland (이하선 목재 이물)

  • Moon, Yoo Jin;Choi, Hwan Jun;Kim, Mi Sun;Choi, Chang Yong;Park, Jin Gue;Kim, Jun Hyuk
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.201-204
    • /
    • 2008
  • Purpose: Now the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma on the face is often underestimated in physical examination. Wood, with its porous consistency and organic nature, provides a good medium for microbial agents. This is a report of our recent experience with wooden foreign bodies in the parotid gland imaged with CT. Methods: A 9-year-old boy was referred for evaluation of possible retained foreign body within his face. One day earlier, he had fallen, face down approximately 1 miter onto ground. He had subsequently undergone an exploration of his right parotido-masseteric area at an outside hospital with repair of a right facial laceration. Enhanced 2 mm axial and coronal CT scans were obtained through the face. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2 mm section thickness. Results: We finally decided the linear "gas" attenuation was a foreign body because of its linear configuration, which did not conform to that of an anatomic structure, and on the basis of articles that described a wood foreign body in the orbit as having the appearance of air. We found that wood was hypoattenuating($-464{\pm}27HU$). Conclusion: We recommend this type of software program for CT scanning for any patient with an injury on the face in which a foreign body is suspected.

Retrohepatic Inferior Vena Cava Injury by Gunshot - A case report - (총상에 의한 간 후부 하대정맥 손상 - 1예 보고 -)

  • Yoo, Dong-Gon;Park, Chong-Bin;Choi, Kun-Moo;Jung, Hwa-Sung;Kim, Chong-Wook
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.124-127
    • /
    • 2008
  • Injury to the inferior vena cava (IVC) is associated with a high mortality rate, and little progress has been made for improving the treatment for this since the 1970s. Injury to the retrohepatic IVC, in particular, has been associated with up to a 75% mortality rate due to the difficulty in gaining adequate exposure and controlling the bleeding. Both the severity of injury and anatomic accessibility has been directly correlated with survival in IVC injury. We have experienced a patient with retrohepatic IVC that was ruptured by a penetrating gunshot injury and we managed to save this patient's life.

Development of an Automatic Soil Hardness Measuring System Mountable on Agricultural Tractors (트랙터 부착형 자동 토양경도 측정 시스템 개발)

  • 이현동;김기대;김찬수;김성환
    • Journal of Biosystems Engineering
    • /
    • v.27 no.6
    • /
    • pp.537-546
    • /
    • 2002
  • In this study an automatic soil hardness measuring system mountable on agricultural tractors was developed to improve the accuracy of manual soil hardness testers by a constant penetrating rate, right direction of the cone-penetrometer and the isolation of vibration from the operator. This was necessary to supply similar experimental condition for performance test of new model and comparative experiment. The results of the study are summaried as follows; 1. The system consisted of a sensing part of soil hardness, a driving part of the measuring system and an attaching part between the tractor and the measuring system. 2. The allowable limit value of the system developed was set to 392N to protect from breaking the serve motor and the coupling used in this system. 3. The driving shaft penetrated into soil by 0.3m to measure soil hardness. The soil hardness was measured at the depth of 0.3m from the soil surface but the penetrating work was stopped and the driving shaft was pulled out to protect the system when the value of the soil hardness was too big on foreign substances like stones or straws. 4. Two values measured by automatic measuring system developed in this research and manual penetrometer were compared by statistics hypothesis testing method. When two people measured the soil hardness at the depth of 0.1 and 0.15m by manual cone penetrometer, there was no relationship between two values by two people but the values at the same depths by automatic measuring system developed showed similarity. The automatic system, therefore, developed in this research was proper for measuring soil hardness.