• Title/Summary/Keyword: penetrating

Search Result 999, Processing Time 0.028 seconds

Study on the Skin Absorption of the Organic Solvents (유기용제의 피부흡수 연구)

  • Kim, Hyeon-Yeong;Chung, Yeong-Hyen;Jeong, Jae-Hwang;Sur, Gil-Soo;Moon, Young-Han
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.279-288
    • /
    • 1997
  • The penetrating speeds of organic solvents into the nude mouse skin were measured by in vitro methods(diffusion cell methods) and in vivo methods(measuring internal residues of the organic solvents). The results were as follows: 1. The penetrating speeds of toluene, m-xylene, MEK, MIBK, ethanol, IPA and 2-bromopropane into the skin were $0.4832mg/cm^2/h$, $0.1738mg/cm^2/h$, $1.124mg/cm^2/h$, $0.6627mg/cm^2/h$, $1.747mg/cm^2/h$, $1.359mg/cm^2/h$, and 2-bromopropane $4.165mg/cm^2/h$ respectively. 2. The penetrating speeds of the mixtures of two, toluene and m-xylene, the mixture of three, IPA, ethyl acetate, and MIBK, the mixture of five, toluene, m-xylene, IPA, ethyl acetate, and MIBK were $0.172mg/cm^2/h$, $1.431mg/cm^2/h$, and $2.983mg/cm^2/h$ respectively. 3. The absorption speeds of 2-bromopropane and styrene which were measured by in vivo processes were $3.12mg/cm^2/h$ and $1.44mg/cm^2/h$ respectively. The absorption speed of 2-bromopropane mesured in vivo was 74.9% of that measured by in vitro methods, $4.165mg/cm^2/h$.

  • PDF

High resolution groud penetrating image radar using an ultra wideband (UWB) impulse waveform (초광대역 임펄스를 이용한 고해상도 지반탐사 이미지 레이더)

  • Park Young-Jin;Kim Kwan-Ho;Lee Won-Tae
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.101-106
    • /
    • 2005
  • A ground penetrating image radar (GPR) using an ultra wideband (UWB)impulse waveform is developed for non destructive detection of metallic pipelines buried under the ground. Dielectric constant of test field is measured and then a GPR system is designed for better detection up to 1 meter deep. By considering total path loss, volume of complete system, and resolution, upper and lower frequencies are chosen. First, a UWB impulse for the frequency bandwidth of the impulse is chosen with rising time less than 1 ns, and then compact planar UWB dipole antenna suitable for frequency bandwidth of a UWB impulse is designed. Also, to receive reflected signals, a digital storage oscilloscope is used. For measurement, a monostatic technique and a migration technique are used. For visualizing underground targets, simple image processing techniques of A-scan removal and B-scan average removal are applied. The prototype of the system is tested on a test field in wet clay soil and it is shown that the developed system has a good ability in detecting underground metal objects, even small targets of several centimeters.

Application of Ground Penetrating Radar for Assessing Riverbed Variation Near Bridge Piers (지하투과레이다를 이용한 교각 주변의 하상변화 조사)

  • Park, In-Chan;Cho, Won-Cheol;Lee, Jong-Kook
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.119-128
    • /
    • 2005
  • The assessment of erosional and depositional patterns near bridge piers is essential to understand the fluvial scour process. Geophysical surveys are particularly effective in determining the riverbed variations in a river and may also be of value for obtaining the previous scour history below the riverbed profile. In this study, GPR (Ground Penetrating Radar), as a non-destructive geophysical technique, was used to assess the existence and depth of existing and infilled scour thickness, streambed materials, and pre- and post- scour surfaces at the bridge piers in Han River, June 2002 and October 2002. The GPR acquisition system used for obtaining profiles of the shallow subsurface deposits was a portable GSSI SIR 2000 system with 100 and 400 MHz antennas. The GPR data obtained along the 24 bridge piers in the flow direction of the river and in the surroundings of 5 bridge piers were compared and presented in this study. It is concluded that GPR surveys can be effective in determining both the water depth and sub-bottom geological structure near the bridge piers and abutments provided that the appropriate instrumentation and operational procedures are applied.

Delayed Detection of a Penetrating Tracheal Foreign Body (수상 후 10년이 지나 발견된 기관 내 이물질)

  • Jang, Woo-Sung;Kim, Young-Tae;Kim, Joo-Hyun;Kang, Chang-Hyun
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.384-387
    • /
    • 2007
  • The finding of a tracheal penetrating injury that's caused by a foreign body is rare in adulthood. A 42-year-old man had experienced penetrating trauma due to a glass fragment 10 years ago. He presented with blood tinged sputum and dyspnea on exertion, and this had developed 1 year previously. Chest CT scan and bronchoscopy revealed a foreign body crossing the tracheal lumen and the object arose from outside of the trachea; this was all associated with airway edema. We removed the foreign body, which was a 5cm length of glass fragment, and we repaired the tracheal defect using a simple primary suture. The postoperative course of the patient was uneventful and he is now being followed up at the outpatient department; he has had no additional symptoms.

Detection of Delamination inside Concrete Using Ground Penetrating Radar (GPR을 이용한 콘크리트 내 공동 탐사)

  • Rhim, Hong-Chul;Lee, Soong-Jae;Woo, Sang-Kyun;Song, Young-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.177-184
    • /
    • 2003
  • A series of experimental work has been conducted to evaluate the capability of Ground Penetrating Radar (GPR) system in detecting delamination inside concrete. Three antenna at 900 MHz, 1000 MHz, and 1500 MHz frequency are used in the experiments for laboratory size specimens, and 400 MHz antenna has been used for a large size specimen. The laboratory size specimens have the dimensions of 1,000 mm (length) ${\times}$ 600 mm (width) ${\times}$ 140 mm (thickness) with a delamination of 200 mm (length) ${\times}$ 600 mm (width) ${\times}$ 140 mm (thickness). The cover depth of the delamination is varied as follows: 20 mm, 30 mm, 60 mm, and 70 mm. In all cases, the delamination has been successfully identified. The property of three frequencies was seized about detecting delamination. Also, it was shown that the image results in GPR were improved by signal processing.

Analysis of Dynamically Penetrating Anchor based on Coupled Eulerian-Lagrangian (CEL) Method (Coupled Eulerian-Lagrangian (CEL) 방법을 이용한 Dynamically Penetrating Anchor의 동적 거동 분석)

  • Kim, Youngho;Jeong, Sang-Seom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.895-906
    • /
    • 2014
  • A fundamental study of the dynamically penetrating anchor (DPA - colloquially known as torpedo anchor) embedded into deep seabed was conducted using measurement data and numerical approaches. Numerical simulation of such a structure penetration was often suffered by severe mesh distortion arising from very large soil deformation, complex contact condition and nonlinear soil behavior. In recent years, a Coupled Eulerian-Lagrangian method (CEL) has been used to solve geomechanical boundary value problems involving large deformations. In this study, 3D finite element analyses using the CEL formulation are carried out to simulate the construction process of dynamic anchors. Through comparisons with results of field measurements, the CEL method in the present study is in good agreement with the general trend observed by in-situ measurements and thus, predicts a realistic large deformation movement for the dynamic anchors by free-fall dropping, which the conventional FE method cannot. Additionally, the appropriate parametric studies needed for verifying the characteristic of dynamic anchor are also discussed.

A Case Study of Tunnel Stability due to the Shallow Shaft and Change Penetrating Location (터널 갱구부 저토피 및 관통부 변경에 따른 안정성 검토 사례 연구)

  • Lee, Saik;Choi, Youngchul;Jung, Wooyong;Kim, Kookhan;Kim, Dongin
    • Tunnel and Underground Space
    • /
    • v.23 no.2
    • /
    • pp.87-98
    • /
    • 2013
  • Around 70% of Korea is mountainous, an increase in tunnel construction. It's due to the growing interest of the public for the environment and land required for the road construction is very scarce. During construction of 'Daedong 1 tunnel' in the expressway expansion project between Naengjeong and Busan, there are shallow shaft due to this tunnel located in the valley and the shafts are separated, and penetrating location change was inevitable for construction was delayed because of complaint. So, we change the position of the penetrating by applying multi-channel TSP, and conducted a stability analysis. The analysis results showed that there is no problem on the stability of the tunnel. To secure the construction of additional stability, We installed instrument, performed mechanical excavation, added reinforcement at shallow shaft and conducted bench cut.

Experience of Penetrating Gunshot Wound on Head in Korea

  • Kim, Hong Rye;Go, Seung Je;Sul, Young Hoon;Ye, Jin Bong;Lee, Jin Young;Choi, Jung Hee;Choi, Seoung Myoung;Kim, Yook;Yoon, Su Young
    • Journal of Trauma and Injury
    • /
    • v.31 no.2
    • /
    • pp.82-86
    • /
    • 2018
  • Craniocerebral gunshot injuries (CGIs) are extremely seldom happened in Korea because possession of individual firearm is illegal. So, CGIs are rarely encountered by Korean neurosurgeons or Korean trauma surgeons, though in other developing countries or Unites states of America their cases are indefatigably increasing. Management goal should focus on early aggressive, vigorous resuscitation. The treatments consist of immediate life salvage through correction of coagulopathy, intracranial decompression, prevention of infection and preservation of nervous tissue. There have been few studies involving penetrating CGIs in Korea. Here we present a case of penetrating gunshot wound in Korea. We present a 58-year-old man who was unintentionally shot by his colleague with a shotgun. The patients underwent computed tomography (CT) for assessment of intracranial injury. The bullet passed through the left parietal bone and right lateral ventricle and exited through the posterior auricular right temporal bone. After CT scan, he arrested and the cardiopulmonary resuscitation was conducted immediately. But we were unable to resuscitate him. This case report underscores the importance of the initial clinical exam and CT studies along with adequate resuscitation to make the appropriate management decision. Physicians should be familiar with the various injury patterns and imaging findings which are poor prognostic indicators.

Studies on Skin Permeation with Polymer Micelles and the Cell Penetrating Peptide of Pyrus Serotina Var Stem Extracts

  • An, Gyu Min;Park, Su In;Kim, Min Gi;Heo, Soo Hyeon;Shin, Moon Sam
    • Korean Chemical Engineering Research
    • /
    • v.58 no.1
    • /
    • pp.21-28
    • /
    • 2020
  • The stem extract from Pyrus serotina var has natural antioxidant ability, but the extraction method does not result in a soluble compound in cosmetic formulations. This study investigated the cosmetic efficacy of the Pyrus serotina var stem extract and its epidermis permeation ability when combined with polymer micelles and a cell penetrating peptide. The total concentration of polyphenol compounds was determined to be 103.1644 ± 1.38 mg/g in the ethanol extract and 78.97 ± 1.45 mg/g in the hydrothermal extract. The 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging effects were 55.94 ± 0.22% in the ethanol extract at 1,000 mg/L. Superoxide dismutase (SOD) activity rates were 104.05 ± 3.28% in the ethanol extract at 62.5 mg/L. The elastase inhibition rate was 67.21 ± 2.72% in the ethanol extract at 1,000 mg/L. An antimicrobial effect was observed in the Propionibacterium acnes strain. In the epidermal permeability experiment, it was confirmed that formulation of the polymer micelle containing the Pyrus serotina var stem extract and cell penetrating peptide (R6, hexa-D-arginine) showed small particle size and much better skin permeability. The cumulative amount of total Pyrus serotina var stem extract that penetrated to the skin over time increased over 24 hours in three formulations. The three formulations showed 51.61 ㎍/㎠ (Formulation 0), 75.97 ㎍/㎠ (Formulation 1) and 95.23 ㎍/㎠ (Formulation 2) skin penetration, respectively. Therefore, it was confirmed that the ethanol extracts of Pyrus serotina var stem showed good cosmetic efficacy and excellent epidermis permeation ability when combined with a polymer micelle and cell penetrating peptide. Thus, this extract has the potential to be used as a safe and natural cosmetic material in the future.

Evisceration and Intrascleral Silicone Ball Prosthesis with Penetrating Keratoplasty on Perforated Corneal Ulcer Secondary to KCS in a Shih Tzu Dog (개의 건성각결막염에 의한 각막천공을 안구내용물적출술과 실리콘볼 삽입 후 각막이식을 적용하여 치료한 증례)

  • Kim, Jong Min;Kim, Jongyeol;Kim, Hwangmin;Jang, Se Wng;Jeong, In Seong;Choi, Seok Hwa
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.356-358
    • /
    • 2015
  • When severely large corneal perforation occurs, penetrating keratoplasty is a treatment of choice alternative to enucleation. A twelve-year-old male Shih Tzu was referred with perforated corneal ulcer secondary to keratoconjunctivitis sicca (KCS). Perforated cornea was directly sutured using 10-0 non-absorbable suture material, and rotational conjunctival flap was performed. However, re-perforation of cornea by wound dehiscence was observed at 1 month after operation. The yellowish lens escaped outside the orbit during corneal re-perforation, the diagnosis was re-perforated corneal ulcer, moderate corneal edema, moderate KCS (STT; 6 mm) and endophthalmitis caused by escaped lens outside orbit. Accordingly, penetrating keratoplasty (PK) and evisceration through corneal recipient site and intrascleral silicone ball prosthesis were carried out as the planned treatment, and resulted in good cosmetic improvement compared to enucliation. However, exposure of silicone ball occurred at the 9 months after the surgery due to the irritation of implant, thus enucleation was performed. In perforated large corneal ulcer with severe intraocular damage, evisceration with silicone ball insertion with PK would be alternative treatment choice to improve the cosmetic appearance.