• Title/Summary/Keyword: pencil

Search Result 475, Processing Time 0.032 seconds

Application of Acrylic Resins Containing Caprolactone Group and 90% Solid Contents to High-Solid Coatings (카프로락톤기 함유 90% 고형분인 아크릴수지의 하이솔리드 도료에의 적용)

  • Park, Hong-Soo;Yang, In-Mo;Kim, Seung-Jin;Kim, Young-Geun;Jung, Choong-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.149-159
    • /
    • 2007
  • In order to prepare high-solid coatings, acrylic resins, HSCs [poly (EA/EMA/2-HEMA/CLA)] that contain 90% solid, were synthesized by copolymerization of ethyl acrylate (EA), ethyl methacrylate (EMA), 2-hydroxyethyl methacrylate (2-HEMA) and caprolactone acrylate (CLA). The high-solid coatings named as CHSCs (HSCs/HDI-trimer) were prepared by the curing reaction between the acrylic resins containing 90% solid contents and the isocyanates (HDI-trimer) curing agent room temperature. The curing behavior and various properties were examined on the film coated with the both high-solid coatings. The glass transition temperatures $(T_g)$ of CHSCs increased proportionally with increasing the predicted $T_g$ value by Fox equation, and had nothing to do with the solid contents. The prepared film showed good properties for $60^{\circ}$ specular gloss, impact resistance, cross-hatch adhesion and heat resistance, and bad properties for pencil hardness, drying time, and pot-life. Among the film properties, the heat resistance was very excellent and could be explained by the introduction of functional monomers of CLA.

Preparation of Hard Coating Films with High Refractive Index from Titania Nanoparticles (이산화티탄 나노입자로부터 고굴절 하드코팅 도막의 제조)

  • Kim, Nam Woo;Ahn, Chi Yong;Song, Ki Chang
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.762-769
    • /
    • 2015
  • The titania ($TiO_2$) nanoparticles with a diameter 2?3 nm were synthesized by controlling hydrolysis of titanium tetraisopropoxide (TTIP) in acid solution. Organic-inorganic hybrid coating solutions were prepared by reacting the titania nanoparticles with 3-glycidoxypropyl trimethoxysilane (GPTMS) by the sol-gel method. The hard coating films with high refractive index were obtained by curing thermally at $120^{\circ}C$ after spin-coating the coating solutions on the polycarbonate (PC) sheets. The coating films showed high optical transparency of 90% in the visible range and exhibited a pencil hardness of 2H. Also, the refractive index at 633 nm wavelength of coating films enhanced from 1.502 to 1.584 as the weight content of titania nanoparticles in the coating solutions increased from 4% to 25%.

Preparation of PEDOT-TiO2 Composite Thin Film by Using Simultaneous Vapor Phase Polymerization (동시-기상중합법을 이용한 Poly(3,4-ethylenedioxythiophene)(PEDOT)-TiO2 하이브리드 박막 제조)

  • Ko, Young Soo;Han, Yong-Hyeon;Yim, Jin-Heong
    • Polymer(Korea)
    • /
    • v.38 no.4
    • /
    • pp.525-529
    • /
    • 2014
  • PEDOT-$TiO_2$ hybrid conductive thin film including semiconductive metal oxide was successfully prepared via simultaneous vapor phase polymerization (VPP). The mechanical properties such as pencil hardness and anti-scratch property as well as optoelectrical properties of PEDOT-$TiO_2$ hybrid thin film could be improved as compared with pristine PEDOT thin film. Physicochemically stable crosslinked $TiO_2$ layer derived from a sol-gel process by FTS was generated in the PEDOT thin film layer by simultaneous VPP, resulting in improving mechanical properties of the hybrid thin films without any deterioration of their original optoelectrical properties. PEDOT-$TiO_2$ hybrid thin film showed better electrical conductivity as compared with PEDOT film. It might be due to the fact that the surface morphology of hybrid thin film prepared by simultaneous VPP showed smoother than that of pristine PEDOT thin film.

The Development of a Test of Earth Science Inquiry Skills for High School Student (고등학생의 지구과학 탐구능력 측정을 위한 평가도구 개발)

  • Woo, Jong-Ok;Lee, Hang-Ro
    • Journal of The Korean Association For Science Education
    • /
    • v.15 no.1
    • /
    • pp.92-103
    • /
    • 1995
  • Since the late of 1960,s, the improvement of science inquiry skills has been one of the most important goals in secondary science education. To achieve this goal, it is essential to develop a valid and reliable instrument for evaluating science inquiry skills. The purpose of this study is to develop a valid and reliable instrument for evaluating science inquiry skills for high school students. The instrument is developed through R & D procedure, which includes two field trials of the instrument. This study has formed a clear definition of the elements of science inquiry skills (formulating a hypothesis, controlling variables, designing an experiment, numeric calculation, graphing experimental data, inference, determining relationship, determining causalities, predicting experimental results , drawing a conclusion, formulating a generalization or model), and established the goals of assessment and developed the items of assessment. The instrument, Test of Earth Science Inquiry Skills, consists of 33 items which measure 11 science inquiry skills. There are content-free items for each science inquiry skills. This study has selected 11 science inquiry skills which are considered appropriate for being evaluated by paper-and-pencil test with SIEI (Hur,1984). The content validity of items, objectivity of the scoring keys and clarity of the items were checked by six experienced specialists in science education. At the same time, the two field trials has been executed and produced the reliability of the instrument, item difficulty index, and the effectiveness of distracters. The first field trial was performed using a sample of 304 high school students, and the second one using a sample of 872 high school students. Because the content validity is 84 % and the reliability (K-R 20) is 0.84, the developed instrument in this study is considered valid and reliable. The difficulty index is 49.4 %, answer ratio 59.1 %, the discrimination index 0.47 and the effectiveness of distracters evenly distributed, which also suffice the criteria of good instrument. The developed instrument in this study can diagnosis the well-developed science inquiry skills and the ill-developed science inquiry skills of the students, and trace the degree of the improvement of science inquiry skills.

  • PDF

Factors Affecting Nucleation and Growth of Chromium Electrodeposited from Cr3+ Electrolytes Based on Deep Eutectic Solvents

  • El-Hallag, Ibrahim S.;Moharram, Youssef I.;Darweesh, Mona A.;Tartour, Ahmed R.
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.291-309
    • /
    • 2020
  • Chromium was electrodeposited from deep eutectic solvents-based Cr3+ electrolytes on HB-pencil graphite electrode. Factors influencing the electrochemical behavior and the processes of Cr nucleation and growth were explored using cyclic voltammetry and chronoamperometry techniques, respectively. Cr3+ reduction was found to occur through an irreversible diffusion-controlled step followed by another irreversible one of impure diffusional behaviour. The reduction behavior was found to be greatly affected by Cr3+ concentration, temperature, and type of hydrogen bond donor used in deep eutectic solvents (DESs) preparation. A more comprehensive model was suggested and successfully applied to extract a consistent data relevant to Cr nucleation kinetics from the experimental current density transients. The potential, the temperature, and the hydrogen bond donor type were estimated to be critical factors controlling Cr nucleation. The nucleation and growth processes of Cr from either choline chloride/ethylene glycol (EG-DES) or choline chloride/urea (U-DES) deep eutectic solvents were evaluated at 70℃ to be three-dimensional (3D) instantaneous and diffusion-controlled, respectively. However, the kinetics of Cr nucleation from EG-DES was found to be faster than that from U-DES. Cr nucleation was tending to be instantaneous at higher temperature, potential, and Cr3+ concentration. Cr nuclei electrodeposited from EG-DES were characterized at different conditions using scanning electron microscope (SEM). SEM images show that high number density of fine spherical nuclei of almost same sizes was nearly obtained at higher temperature and more negative potential. Energy dispersive spectroscopy (EDS) analysis confirms that Cr deposits were obtained.

A Study on the Relation between Occlusal Wear Area and Occlusal Contact Patterns (교모면적과 교합접촉양태 간의 관계에 대한 연구)

  • Se-Sook Kang;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.153-168
    • /
    • 1994
  • The aim of the present study was to investigate a relation between occlusal wear area and occlusal contact patterns. For the purpose, occlusal wear area were measured in 58 dental students and in 129 patients with temporomandibular disorders(TMDs) from dental casts. Teeth used in this study were from canine to second molar on both sides in upper arch, totally ten. Occlusal wear area on casts was marked by pencil and photocopies, and then, the area was measured with planimeter. Occlusal relation was clinically examined with regard to Angle's classification, chewing side preference, lateral guidance pattern and bruxing and/or clenching habit. T-Scan, electronic occlusal contact analyzer, was used to record occlusal contact number, contact force, contact time and occlusal balance that is TLR(total left-right statistics) during tooth contact. All measurement were repeated 3 times and the average value was used for data processing. The obtained results were as follows : 1. Mean value of occlusal wear area did not differ significantly between dental students and patients. 2. There ws not significant difference in wear area between chewing side and non-chewing side in both groups. 3. Occlusal wear area was significantly increased with age in both groups. 4. Three subgroups divided by Angle's classification did not show any difference in occlusal wear area among them, but three subgroups divided by lateral guidance pattern showed slightly significant difference between canine guide subgroup and group function subgroup in patients. Occlusal wear ares\a in group function subgroup wear larger than canine guide subgroup. 5. Mean value of wear area in patients with bruxing and/or clenching habit did not differ from those in patients without such habit. 6. Correlationship among items related to occlusal contact pattern were highly consistent and significant in dental students and only one item significantly correlated with occlusal wear area was tooth contact time.

  • PDF

Subarray Structure Optimization Algorithm for Active Phased Array Antenna Using Recursive Element Exchanging Method (재귀적 소자 교환 방식을 이용한 능동위상배열안테나 부배열 구조 최적화 알고리즘)

  • Chae, Heeduck;Joo, Joung Myoung;Yu, Je-Woo;Park, Jongkuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.8
    • /
    • pp.665-675
    • /
    • 2016
  • With the development of active phased array radar technology in recent years, active phased array antennas, which digitally combine signals received from subarray units using dozens of digital receiver, have been developed. The beam characteristics are greatly affected by the shape of the subarray structure as well as the weight of subarray in digital beamforming. So in this paper, the method to generate subarray structures by using recursive element exchanging method and the method to optimize subarray structures that can minimize sidelobes of operating beams are proposed. Additionally it presents the result to find the optimized subarray structure to minimize the maximum sidelobe of monopulse beam and pencil multi-beam respectively or simultaneously which are commonly used for digital beamforming by applying the algorithm propsed in this paper.

A Comparative Study of Item Difficulty Hierarchy of Self-Reported Activity Measure Versus Metabolic Equivalent of Tasks

  • Choi, Bong-Sam
    • Physical Therapy Korea
    • /
    • v.20 no.3
    • /
    • pp.89-99
    • /
    • 2013
  • The purposes of this study were: 1) to show the item difficulty hierarchy of walking/moving construct of the International Classification of Functioning, Disability and Health-Activity Measure (ICF-AM), 2) to evaluate the item-level psychometrics for model fit, 3) to describe the relevant physical activity defined by level of activity intensity expressed as Metabolic Equivalent of Tasks (MET), and 4) to explore what extent the empirical activity hierarchy of the ICF-AM is linked to the conceptual model based on the level of energy expenditure described as MET. One hundred and eight participants with lower extremity impairments were examined for the present study. A newly created activity measure, the ICF-AM using an item response theory (IRT) model and computer adaptive testing (CAT) method, has a construct on walking/moving construct. Based on the ICF category of walking and moving, the instrument comprised items corresponding to: walking short distances, walking long distances, walking on different surfaces, walking around objects, climbing, and running. The item difficulty hierarchy was created using Winstep software for 20 items. The Rasch analyses (1-parameter IRT model) were performed on participants with lower extremity injuries who completed the paper and pencil version of walking/moving construct of the ICF-AM. The classification of physical activity can also be performed by the use of METs that is often preferred to determine the level of physical activity. The empirical item hierarchy of walking, climbing, running activities of the ICF-AM instrument was similar to the conceptual activity hierarchy based on the METs. The empirically derived item difficulty hierarchy of the ICF-AM may be useful in developing MET-based activity measure questionnaires. In addition to convenience of applying items to questionnaires, implications of the finding could lead to the use of CAT method without sacrificing the objectivity of physiologic measures.

A Monitor Unit Verification Calculation in IMRT as a Dosimetry QA

  • Kung, J.H.;Chen, G.T.Y.;Kuchnir, F.T.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.68-73
    • /
    • 2002
  • In standard teletherapy, a treatment plan is generated with the aid of a treatment planning system, but it is common to perform an independent monitor unit verification calculation (MUVC). In exact analogy, we propose and demonstrate that a simple and accurate MUVC in Intensity Modulated Radiotherapy (IMRT) is possible. We introduce a concept of Modified Clarkson Integration (MCI). In MCI, we exploit the rotational symmetry of scattering to simplify the dose calculation. For dose calculation along a central axis (CAX), we first replace the incident IMRT fluence by an azimuthally averaged fluence. Second, the Clarkson Integration is carried over annular sectors instead of over pie sectors. We wrote a computer code, implementing the MCI technique, in order to perform a MUVC for IMRT purposes. We applied the code to IMRT plans generated by CORVUS. The input to the code consists of CORVUS plan data (e.g., DMLC files, jaw settings, MU for each IMRT field, depth to isocenter for each IMRT field), and the output is dose contribution by individual IMRT field to the isocenter. The code uses measured beam data for Sc, Sp, TPR, (D/Mu)$\_$ref/ and includes effects from MLC transmission, and radiation field offset. On a 266 MHZ desktop computer, the code takes less than 15 sec to calculate a dose. The doses calculated with MCI algorithm agreed within +/- 3% with the doses calculated by CORVUS, which uses a 1cm x 1cm pencil beam in dose calculation. In the present version of MCI, skin contour variations and inhomogeneities were neglected.

  • PDF

Female Consumers' Attitudes and Purchase Intentions toward Intimate Apparel Brands

  • Rose, Jennifer;Cho, Eunjoo;Smith, Kathleen R.
    • Fashion, Industry and Education
    • /
    • v.14 no.2
    • /
    • pp.35-46
    • /
    • 2016
  • The purpose of this study was to examine female consumers' attitudes and purchase intentions toward intimate apparel brands. To understand female consumers' shopping behaviors for intimate apparel products, this study examined interrelationships among brand familiarity, perceived risk, attitudes, and purchase intentions toward intimate apparel brands. A conceptual model was developed by adopting perceived risk theory (Cox, 1967) and theory of reasoned action (Ajzen & Fishbein, 1980). A pre-survey using a paper and pencil was conducted to identify the most familiar intimate apparel brand to young female consumers. The majority of pre-survey respondents (66 female college students) indicated Victoria's Secret as the most prominent intimate apparel brand. Therefore, Victoria's Secret was used to examine possible effects of brand familiarity on perceived risk and attitudinal and behavioral responses toward the brand. Using a web-based survey, 384 complete responses were collected from young female college students between the ages of 18-29 at a Mid-southern U.S. university. A structural equation modeling was employed to test the proposed research model and hypotheses. Results showed positive, statistically significant associations among the four variables (e.g., brand familiarity, perceived risk, attitudes, and purchase intentions). The findings suggested that young female consumers who are familiar with a particular intimate apparel brand are likely to perceive a low level of risk, leading to positive, strong attitudes with purchase intentions toward that particular intimate apparel brand. This suggests establishing brand familiarity through integrated marketing communication is crucial for risk reduction strategy in intimate apparel shopping.