Investigation of the Optimal Cooling Performance Using Peltier Module and Heat Sink (펠티에 소자 및 히트싱크를 이용한 최적 냉각성능에 관한 연구)

  • Lee, Dong-Ryul
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.65-70
    • /
    • 2006
  • This study is to experimentally evaluate the cooling performance of the Bonding type and Injection type of heat sink using three different kinds of industrial Peltier module by digital LabViewTM measurement. Injection type of heat sink could be more efficient for the heat transfer than Bonding type, even with 30% more radiating surface area. In addition, the experimental results revealed that the sufficient power supplied was able to show the better cooling performance of Peltier module. In order to verify the optimal cooling performance of the cooling device, two Peltier module, HMN 6040 and HMN 1550 with Bonding and Injection type of heat sink were used. The cooling performance with injection type of heat sink was 2.11% and 6.24% better than that with bonding type of heat sink under the HMN 6040 and HMN 1550, respectively.

  • PDF

Temperature Control of the Aluminum Plate using Peltier Element (펠티어 소자를 이용한 알루미늄 판의 온도 제어)

  • 전원석;방두열;최광훈;권대규;김남균;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.764-767
    • /
    • 2004
  • This paper present the temperature control of aluminum plate using Peltier element. Peltier effect is heat pumping phenomena by electric energy as one of the thermoelectric effect. So if current is asserted to Peltier element, it absorbs heat from low temperature side and emits to high temperature side. In this experiment, Peltier element is used to control the temperature of small aluminum plate with ON/OFF control scheme and fan ON/OFF. As the result of experiments, it is proper to act fan only while cooling duration and there exist a proper cooling current to drop temperature rapidly. It takes about 100sec to increase to 7$0^{\circ}C$ and drop to 35$^{\circ}C$ of aluminium plate temperature and about 90sec to increase to 7$0^{\circ}C$ and drop to 4$0^{\circ}C$ in ambient temperature 3$0^{\circ}C$ while fan is on only in cooling duration. Future aim is to realize more rapid temperature control and develop SMHA(special metal hydride actuator) by using Peltier element to heating and cooling.

  • PDF

Thermoelectric Seebeck and Peltier effects of single walled carbon nanotube quantum dot nanodevice

  • El-Demsisy, H.A.;Asham, M.D.;Louis, D.S.;Phillips, A.H.
    • Carbon letters
    • /
    • v.21
    • /
    • pp.8-15
    • /
    • 2017
  • The thermoelectric Seebeck and Peltier effects of a single walled carbon nanotube (SWCNT) quantum dot nanodevice are investigated, taking into consideration a certain value of applied tensile strain and induced ac-field with frequency in the terahertz (THz) range. This device is modeled as a SWCNT quantum dot connected to metallic leads. These two metallic leads operate as a source and a drain. In this three-terminal device, the conducting substance is the gate electrode. Another metallic gate is used to govern the electrostatics and the switching of the carbon nanotube channel. The substances at the carbon nanotube quantum dot/metal contact are controlled by the back gate. Results show that both the Seebeck and Peltier coefficients have random oscillation as a function of gate voltage in the Coulomb blockade regime for all types of SWCNT quantum dots. Also, the values of both the Seebeck and Peltier coefficients are enhanced, mainly due to the induced tensile strain. Results show that the three types of SWCNT quantum dot are good thermoelectric nanodevices for energy harvesting (Seebeck effect) and good coolers for nanoelectronic devices (Peltier effect).

A Consideration on the Application of Thermoelectric Cooler to Obesity Therapy (열전 냉각장치의 비만치료 적용 방법론 고찰)

  • Ko, Yun-Seok;Lee, Woo-Cheol;Kim, In-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1437-1442
    • /
    • 2012
  • The contemporary peoples focus on treatment of obesity in order to prevent the adult disease and to manage the beauty. Although surgical treatment of obesity shows the reliable cure effect, it could cause side effects and has a disadvantage that postoperative recovery period is long. Accordingly, this paper compares and analyzes the non-operative treatments which can be of help to treat obesity. Also, it considers the obesity therapy based on the Peltier cooling system. And finally a basic control circuit based on Peltier module is designed for Peltier cooling-based obesity therapy system.

Optimization of Peltier Current Leads Cooled by Two-Stage Refrigerators

  • Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.3
    • /
    • pp.94-101
    • /
    • 2006
  • A theoretical investigation to find thermodynamically optimum design conditions of conduction-cooled Peltier current leads is performed. A Peltier current lead (PCL) is composed of a thermoelectric element (TE), a metallic lead and a high temperature superconductor (HTS) lead in the order of decreasing temperature. Mathematical expressions for the minimum heat flow per unit current crossing the TE-metal interface and the minimum heat flow per unit current from the metal lead to the joint of the metal and the HTS leads are obtained. It is shown that the temperature at the TE -metal interface possesses a unique optimal value that minimizes the heat flow to the joint and that this optimal value depends on the material properties of the TE and the metallic lead but not the joint temperature nor electric current. It is also shown that there exists a unique optimal value for the joint temperature between the metal and the HTS leads that minimizes the sum of the power dissipated by ohmic heating in the current leads and the refrigerator power consumed to cool the lead, for a given length of the HTS.

A Study of Thermoelectric Effect in Resistance Spot Welding of Aluminium Alloy (알루미늄 합금의 저항점용접에서의 열전 효과에 대한 연구)

  • ;K. T. Rie
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.10-19
    • /
    • 1998
  • The erosion of electrode in spot welding of aluminium alloy by direct current is dependent on the electric polarity. The positive electrode is much more eroded than the negative one. To explain this phenomenon, Peltier effect has been generally accepted as a unique theory. In this study Peltier effect was evaluated by calculations on the basis of some references and experiments. The difference of heat generated by Peltier effect on both electrode surfaces was, however, only 4% of total heat generated during wel- ding. Because of insufficient explanation, Kohler theory, which is mainly affected by thin oxide film, was introduced. A theoretical calculation showed 17% of the temperature difference between the positive and negative electrode, in case "surface voltage" resulted from oxide film was 30% of total contact voltage. This revealed that the erosion of electrode could be more affected by Kohler theory than effect.an effect.

  • PDF

Preparation of Organic Peltier using Fullerene/Polyaniline (Fullerene과 Polyaniline을 이용한 유기 Peltier소자의 개발)

  • Lee, Chae-Jung;Kim, Joo-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.343-345
    • /
    • 2007
  • Temperature difference between two plates occurs when a current is passed though two semi-conductors that are connected each other at two junctions. The current drives a transfer of heat from one junction to the other. In this study, the thermoelectric module based on th "Peltier effect" was made by combing fullerene and polyaniline. Continuous temperature measurements on both surfaces were performed at room temperature($25.4^{\circ}C$) by an infrared non-contact thermometer. The results showed that cool ing effect of $2.2^{\circ}C$ was attained by 30 seconds, after which the effect was continuously vanished mainly due to electro decomposition.

  • PDF

Design of Heat Pump for Temperature Control of Sealed Electric Box (밀폐 형 전장 박스 온도 제어를 위한 히트 펌프 설계)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.2
    • /
    • pp.110-114
    • /
    • 2020
  • In this paper, a heat pump using a Peltier device was developed for heat dissipation in a sealed electric box. The heat pump was designed with a cooling fin attached to both sides of the Peltier device, and a fan was mounted on the cooling fin on the hot side to increase the efficiency. The heat dissipation efficiency could be improved by directly connecting the electronic component having high heat to the cooling fin using a heat conducting wire. The fabricated heat pump was designed to operate only in the temperature range set by the temperature control system to improve the problem of high power consumption of the Peltier element.

Performance Analysis of Cooling Module using Peltier Elements (펠티어 소자를 이용한 냉방모듈 성능해석)

  • Han, Cheolheui
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.1
    • /
    • pp.5-8
    • /
    • 2011
  • Thermal analysis of a cooling module using Peltier elements are performed using a commercial software, CFD-ACE+. A standard k-e two-equation turbulent model is applied in order to represent the turbulent shear stress. Computed values are compared with the theoretical values for the validation. The effect of mass flow rates and transferred heat amounts on the temperature distributions inside the cooling system is analyzed. It was found that the increase in the mass flow rates causes the exit temperature rise. The increase in the absorbed heat amount diminished the overall temperature on the fin surfaces. In the present analysis, the material characteristics of the Peltier element itself are not considered. In the future, the effect of the turbulence models and material characteristics will be studied in detail.

  • PDF

Investigation of the Cooling Performance Using Pottier Module (펠티에 소자를 이용한 냉각성능에 관한 연구)

  • Lee, Sang-Il;Choi, Jin-Wook;Lee, Dong-Ryul
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1156-1161
    • /
    • 2006
  • This study is to evaluate the cooling performance of the Bonding type and Injection type of heat sink using three different kinds of industrial Peltier module by digital $LabView^{TM}$ measurement. Injection type of heat sink could be more efficient for the heat transfer than Bonding type, even with 30% more radiating surface area. In addition, the experimental results revealed that the sufficient power supplied was able to show the better cooling performance of Peltier module.

  • PDF