• 제목/요약/키워드: peak external pressure

검색결과 37건 처리시간 0.021초

디젤발전기 엔진 운전상태 분석 및 평가방법에 대한 연구 (Analysis and Evaluation Study on Diesel Generator Engine Operation Signature)

  • 박종혁;최광희;이상국
    • 동력기계공학회지
    • /
    • 제13권5호
    • /
    • pp.82-88
    • /
    • 2009
  • The purpose of this paper is to provide technical background, techniques and actual diesel engine signature analysis evaluation result. Engine signature analysis(ESA) is a process for monitoring the material condition of diesel engine using external sensors, eliminating the need to periodically disassemble the engine. ESA is also used to balanced the engine. Engine balancing is the process of tuning the engine so that all cylinders carry equal load. ESA is a useful tool to non-intrusively determine the operability and performance and assessment of the material condition of internal component of a diesel engine.

  • PDF

고휘도 Short-Arc 램프용 전자식 안정기 설계 및 제작 (The Design and Fabrication of an Electronic Ballast for High Intensity Short-Arc Lamps)

  • 김일권;박대원;이성근;길경석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.304-309
    • /
    • 2005
  • This paper presents an electronic ballast using a step down converter, a low frequency inverter for high intensity short-arc discharge lamp. The proposed ballast is composed of a full-wave rectifier, a step down converter operated as a current source with power regulation and a low frequency inverter with external ignition circuit. The ignition circuit generates high voltage pulse of $3{\sim}5[kV]$ peak, 130[Hz] periodically. Moreover, it is able to reignite at regular intervals by protective circuit. As experimental results on the test, acoustic resonance phenomenon is eliminated by operating the low frequency square wave voltage and current. Lamp voltage, current and consumption power are measured 123.8[V], 8.1[A] and 1,002[W], respectively. It was confirmed that the designed ballast operate the lamp with a constant power.

  • PDF

직류 플라즈마 제트를 이용한 고속 다이아몬드 막 증착기술 (High-Speed Deposition of Diamond Films by DC Plasma Jet)

  • 김원규;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.949-951
    • /
    • 1992
  • A low pressure DC plasma jet has been used to obtain diamond films from a mixture of $CH_4$ and $H_2$ with high deposition rate (>1$\mu\textrm{m}$/min). The effects of the deposition conditions such as torch geometry, substrate temperature, gas mixing ratio, chamber pressure, axial magnetic field on the diamond film properties such as morphology, purity, uniformity of the film and deposition rate, etc. have been examined with the aid of Scanning Electron Microscopy, X-Ray Diffraction, and Raman Spectroscopy. Both the growth rate and particle size increased rapidly for low methane concentrations but saturated and the morphology changed from octahedral to cubic structure when the concentration exceeded 1.0 %. Higher growth rates (>1.5${\mu}m$/min) can be obtained by applying an axial magnetic field to the DC plasma jet. Diamond obtained from the magnetized plasma jet also shows a sharp peak at 1332.5$cm^{-1}$ in the Raman Spectra and this result implies that higher growth rate with a good quality diamond films can he obtained by applying an external magnetic field to the plasma jet.

  • PDF

PPG 맥파 분석의 PTT 측정변화에 따른 SBP, DBP 추정 융합 알고리즘 변화율 분석 (Analysis of Change Rate of SBP and DBP Estimation Fusion Algorithm According to PTT Measurement change PPG Pulse Wave Analysis)

  • 김선칠
    • 한국융합학회논문지
    • /
    • 제11권7호
    • /
    • pp.35-40
    • /
    • 2020
  • 최근 초소형 생체신호를 측정할 수 있는 스마트 워치 등의 장비들이 출시됨에 따라, 체성분, 혈압, 심박동수, 산소포화도 등 다양한 정보를 쉽게 얻을 수 있다. 그러나 사용자에게 신뢰를 얻지 못하는 부분이 바로 정확성이다. 이러한 생체신호는 외부 환경에 대해 민감하며, 대상자 신체 내부의 조건에 따라 변동값이 크다. 특히 혈압 측정은 아직 신체 내부의 조건들의 처리에 따라 결과값이 다르다. 따라서 실험에서는 PPG 알고리즘에서 혈관 상태를 정의하는 인자를 특정값으로 처리하고 PPG를 분석하였으며, PTT 측정에 있어서 최고점 80%, 100%의 두 지점 PTT 측정값이 SBP와 DBP에 미치는 영향을 분석하였다. 또한 정확도를 높이기 위한 방안 중 하나를 제시하고자 하였다. 연구결과 PPG 최고점 80%에서 측정값 PTT값이 100%에서 측정한 값보다 SBP, DBP 혈압추정에 효과적이며, 변화율 혈압추정의 회귀분석에서 SBP(80%)의 결정계수가 0.6946, DBP(100%)는 0.547로 나타났다. 결론적으로 ECG와 PPG를 통해 PTT를 측정할 경우 PPG 80% 지점의 측정값이 혈압추정의 정확도를 향상시킬 수 있다.

Analysis of actively-confined concrete columns using prestressed steel tubes

  • Nematzadeh, Mahdi;Haghinejad, Akbar
    • Computers and Concrete
    • /
    • 제19권5호
    • /
    • pp.477-488
    • /
    • 2017
  • In this paper, an innovative technique for finite element (FE) modeling of steel tube-confined concrete (STCC) columns with active confinement under axial compressive loading is presented. In this method, a new constitutive model for the stress-strain relationship of actively-confined concrete is proposed. In total, 14 series of experimental STCC stub columns having active confinement were modeled using the ABAQUS software. The results obtained from the 3D model including the compressive strength at the initial peak point and failure point, as well as the axial and lateral stress-strain curves were compared with the experimental results to verify the accuracy of the 3D model. It was found that there existed a good agreement between them. A parametric study was conducted to investigate the effect of the concrete compressive strength, steel tube wall thickness, and pre-stressing level on the behavior of STCC columns with active confinement. The results indicated that increasing the concrete core's compressive strength leads to an increase in the compressive strength of the active composite column as well as its earlier failure. Furthermore, a reduction in the tube external diameter-to-wall thickness ratio affects the axial stress-strain curve and the confining pressure, while increasing the pre-stressing level has a negligible effect on the two.

압력조절환기법과 용적조절환기법의 호흡역학 몇 가스교환의 비교 (Comparison of Respiratory Mechanics and Gas Exchange Between Pressure-controlled and Volume-controlled Ventilation)

  • 정성환;최원준;이정아;김진아;이문우;신형식;김미경;최강현
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권5호
    • /
    • pp.662-673
    • /
    • 1999
  • 연구배경 : Pressure-controlled ventilation(PCV)은 최근 호흡부전 환자에게서 자주 사용되는 환기방식이다. 이론적으로 PCV은 초기에 높은 기류를 제공하므로 volume-controlled ventilation(VCV)에 비해 최고흡기압이 낮고 가스교환에 이점이 있을 것으로 사료된다. 그러나 PCV에서 최고흡기압이 낮은 것에 대해서는 대부분의 보고가 일치하고 있으나 가스교환에 대해서는 상반된 결과를 보고하고 있다. 따라서 본 연구는 호흡부전 환자에서 PCV과 VCV간의 호흡역학과 가스교환의 비교 및 I : E ratio의 변동에 따른 차이가 있는지를 알아보고자 본 연구를 시행하였다. 방 법 : 호흡부전으로 기계호흡을 받고 있는 9명의 환자를 대상으로 하였다. 각 대상환자에서 흡기산소농도, 일회호흡용적, 호흡수 및 호기말양압은 변화시키지 않고, PCV와 VCV을 번갈아 적용하고 I : E ratio를 1 : 2, 1 : 1.3 및 1.7 : 1로 변화시키면서 기도압과 동맥혈 가스분석, 호기 이산화탄소 농도를 측정하여 PCV과 VCV 간의 호흡역학과 가스교환을 비교하였다. 결 과 : PCV과 VCV 모두에서 I : E ratio를 증가시킴에 따라 평균기도압이 증가하였고, $PaCO_2$와 생리적 사강이 감소하였다. 그러나 P(A-a)$O_2$는 변하지 않았다. 각각의 I : E ratio 모두에서 최고흡기압은 PCV시 더 낮았으며, 평균기도압은 PCV에서 더 높았다. 그러나 $PaCO_2$, 생리적 사강 및 P(A-a)$O_2$는 PCV과 VCV간의 차이를 보이지 않았다. 결 론 : 동일한 일회호흡용적, 호흡수 및 I : E ratio 상태에서는 두 환기 양식의 차이에 따른 가스교환의 차이가 없었다.

  • PDF

휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가 (Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds)

  • 유동욱;선영식;오준식;이봉윤;김현식;정광우
    • 대한화학회지
    • /
    • 제64권6호
    • /
    • pp.327-333
    • /
    • 2020
  • 대기 중 미량의 휘발성 유기화합물을 실시간으로 측정할 수 있는 휴대형 GC의 성능을 평가하였다. 휴대형 GC의 크기는 35 × 26 × 15 ㎤, 무게는 5 kg으로 소형·경량이고, 24 VDC, 1 A (최대 3.2 A)의 저전력을 소모하며 공기를 운반 기체로 사용하므로 별도의 가스 실린더를 필요로 하지 않는다. 벤젠, 톨루엔, 에틸벤젠, 자일렌 1 ppmv와 20 ppmv 시료의 크로마토그램에 대한 피크 면적의 상대표준편차(RSD)는 각각 3.79%, 0.48% 이하이고, 머무름 시간의 RSD는 각각 0.40%와 0.08% 이하로 우수한 재현성을 보였다. 또한 방법검출한계(MDL)는 0.09 ppmv로 낮은 검출한계를 나타냈다. 길이 30 m, 내경 0.28 mm의 분리 컬럼을 사용하여 10분 이내의 측정 조건에서 구한 피크용량과 분해능은 다양한 혼합 샘플도 정량 및 정성 분석이 가능함을 입증하였다. 특히 27시간 동안 연속적으로 80회의 분석을 수행하였을 때 관찰된 크로마토그램의 피크 세기와 머무름 시간의 RSD가 각각 2.4%, 0.5% 이하로 좋은 재현성을 보였다. 따라서 본 연구의 휴대형 GC는 실내외 그리고 산업 현장에서 배출되는 휘발성 유해가스의 탐지는 물론 화학 물질의 유출사고에 대응하여 실시간 모니터링 할 수 있는 측정 장비로 활용될 수 있으리라 기대된다.