• Title/Summary/Keyword: peak discharge

Search Result 626, Processing Time 0.026 seconds

A study on power system for plasma sterilization (플라즈마 살균용 전원장치에 관한 연구)

  • Kang, W.J.;Kim, Y.M.;Mun, S.P.;Kwon, S.K.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.52-54
    • /
    • 2002
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described, For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc.. PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[kHz], 1.8[kW] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

Resonance inverter power system for plasma sterilization effective improvement (플라즈마 살균 효과 개선을 위한 공진용 인버터 전원 시스템)

  • Kim, J.Y.;Mun, S.P.;Kim, J.S.;Kim, Y.M.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1172-1174
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

Resonance Inverter Power System for Sterilization Effective Improvement of Plasma (플라즈마 살균 효과 향상을 위한 공전형 전원 시스템)

  • 김주용;문상필;정장근;이현우;서기영
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.397-401
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[㎑], 1.8[㎾] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

Determination of Flood Hydrograph by Remote Sensing Techniques in a Small Watershed (원격탐사 기법에 의한 소유역의 홍수 수문곡선 결정)

  • 남현옥;박경윤;조성익
    • Korean Journal of Remote Sensing
    • /
    • v.5 no.1
    • /
    • pp.13-27
    • /
    • 1989
  • In recent years satellite data have been increasingly used for the analysis of floodprone areas. This study was carried out to demonstrate the usefulness of repetitive satellite imagery in monitoring flood levels of the Pyungchang watershed. Runoff characteristics parameters were analyzed by Soil Conservation Service(SCS) Runoff Curve Number(RCN) based on Landsat imagery and Digital Terrain Model data. The RCN average within the watershed was calculated from RCN estimates for all the pixels(picture elements) and adjusted by antecedent precipitation conditions. The direct runoff hydrograph was derived from the unit hydrograph using SCS dimensionless unit hydrograph and effective rainfalls estimated by the SCS method. In comparsion of the direct runoff hydrograph with the measured rating curve their peak times differ by one hour and peak discharges differ by 5.9 percents of the discharge from each other. It was shown that repetitive satellite image could be very useful in timely estimating watershed runoffs and evaluating ever-changing surface conditions of a river basin.

Impacts of temporal dependent errors in radar rainfall estimate for rainfall-runoff simulation

  • Ko, Dasang;Park, Taewoong;Lee, Taesam
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.180-180
    • /
    • 2015
  • Weather radar has been widely used in measuring precipitation and discharge and predicting flood risks. The radar rainfall estimate has one of the essential problems in terms of uncertainty and accuracy. Previous study analyzed radar errors to reduce its uncertainty or to improve its accuracy. Furthermore, a recent analyzed the effect of radar error on rainfall-runoff using spatial error model (SEM). SEM appropriately reproduced radar error including spatial correlation. Since the SEM does not take the time dependence into account, its time variability was not properly investigated. Therefore, in the current study, we extend the SEM including time dependence as well as spatial dependence, named after Spatial-Temporal Error Model (STEM). Radar rainfall events generated with STEM were tested so that the peak runoff from the response of a basin could be investigated according to dependent error. The Nam River basin, South Korea, was employed to illustrate the effects of STEM on runoff peak flow.

  • PDF

Impact of Parameters of Nonlinear Breach Progression Curve on Outflow Rate (저수지 붕괴함수의 매개변수 결정이 유량과 침수범위에 미치는 영향)

  • Lee, Khil-Ha
    • Journal of Environmental Science International
    • /
    • v.28 no.2
    • /
    • pp.211-217
    • /
    • 2019
  • A Numerical modeling approach is usually applied to reproduce the physical phenomena of a fill dam-break. The accuracy of the dam-break model depends on the physical structure that defines input variables such as the storage volume, breach formation and progress, and the parameters of the model, which are subjective as they are prescribed by users. In this study, a sensitivity analysis was performed for the nonlinear breach progression curve that was already developed, which includes four parameters. The study focuses on the two of the parameters which control the breach forming time and peak discharge. The model is coupled with a two-dimensional flood simulation model (FLO-2D) to examine flood coverage and depth. It is generally observed that the parameter ${\beta}$ controls only the breach forming time, the parameter ${\gamma}$ is particularly sensitive to the peak flow.

Integrated Storage Function Model with Fuzzy Control for Flood Forecasting (II) - Theory and Proposal of Model - (홍수예보를 위한 통합저류함수모형의 퍼지제어 (II) - 이론의 모형의 수립 -)

  • Lee, Jeong-Gyu;Kim, Han-Seop
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.6
    • /
    • pp.701-709
    • /
    • 2000
  • Integrated storage function model (ISFM) is applied to some rainfall-runoff events of the selected basins in Korea to show validity of the proposed model. Comparing the numerical results of the model with the field measurements, the simulated hydrographs and peak flood discharges for the most part showed good agreements, except the occurrence time of the peak discharges which showed a bit discrepancy, and they showed it was very hard to have a sufficient lead-time to forecast the flood when the upstream inflow of the channel reach was more dominant than the inflow from the residual watershed of the channel.hannel.

  • PDF

Detection of Deep Subsurface Cracks in Thick Stainless Steel Plate

  • Kishore, M.B.;Park, D.G.;Jeong, J.R.;Kim, J.Y.;Jacobs, L.J.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.312-316
    • /
    • 2015
  • Unlike conventional Eddy Current Test (ECT), Pulsed Eddy Current (PEC) uses a multiple-frequency current pulse through the excitation coil. In the present study, the detection of subsurface cracks using a specially designed probe that allows the detection of a deeper crack with a relatively small current density has been attempted using the PEC technique. The tested sample is a piece of 304 stainless steel (SS304) with a thickness of 30mm. Small electrical discharge machining (EDM) notches were put in the test sample at different depths from the surface to simulate the subsurface cracks in a pipe. The designed PEC probe consists of an excitation coil and a Hall sensor and can detect a subsurface crack as narrow and shallow as 0.2 mm wide and 2 mm deep. The maximum distance between the probe and the defect is 28 mm. The peak amplitude of the detected pulse is used to evaluate the cracks under the sample surface. In time domain analysis, the greater the crack depth the greater the peak amplitude of the detected pulse. The experimental results indicated that the proposed system has the potential to detect the subsurface cracks in stainless steel plates.

A study on the dependance of substrate material and the properties of electron beam radiation in plasma polymerized films (플라즈마 중합막의 기판재질 의존성과 전자선 조사 특성에 대한 연구)

  • 김종택;박수홍;김형권;김병수;이덕출
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.4
    • /
    • pp.410-414
    • /
    • 1998
  • The dependence of substrate material and electrode position were studied by radiation analysis of Ar discharge, and electron beam radiation was applied to confirm the crosslinked structure of the film. Comparing the conductor substrate with the insulator substrate, the former had lager peak density of radiation spectrum than latter. From the result of peak density of metastable state and ion, it was confirmed that the peak density of ion was falling to the down limit with increasing the distance of electrode by analyzing the radiation spectrum of polymerized films. When the polymerized styrene films was exposed to electron beam, it was possible to form a pattern with the insulator substrate.

  • PDF

Development of Electronic Ballast for Automotive High Intensity Discharge Lamp (자동차 헤드라이트용 전자식 안정기 개발)

  • 박종연;배수호;조계현
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.319-322
    • /
    • 2002
  • In this Paper, we suggested the Half-Bridge inverter for the automotive HID electronic ballast. electronic ballast for automotive HID lamp should be supplied by low-frequency square wave avoiding the acoustic resonance(11kHz ∼ 825kHz). When the HID lamp is hot state, the electronic ballast should supply the sufficient current for a few milli-second to the lamp at the re-strike ignition state. that is called take-over current. We have introduced the new take-over current control method that could have reduced the peak current and supplied the sufficient take-over current.

  • PDF