• Title/Summary/Keyword: peak detection

Search Result 943, Processing Time 0.031 seconds

Peak detection algorithm at time domain of full-digital portable radiation detection system (휴대용 방사능 검출기의 시간 영역에서의 최고값 검출 알고리즘)

  • Hwang, Dong Gyu;Kim, Young Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.323-325
    • /
    • 2015
  • The purpose of the thesis is to suggest the algorithm that can be covered only by software instead of the function of pulse shaper that was used in the time domain. In order to implementing portable radiation detector for digital.

  • PDF

Modeling of Instrumental Tone considering Main frequency and Harmonics (기본 주파수와 고조파 성분을 고려한 악기음의 모델링)

  • 오복환;이동규;이두수
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.1127-1130
    • /
    • 1999
  • In this paper, using one method of Additive Synthesis, Analysis-by-synthesis/Overlap-Add (ABS/OLA) method, analysis and synthesis of musical tones is processed. But peak detection of frequency domain is processed by proposed method considering the view of acoustics. It is that that harmonics frequency is times of main frequency. Using this fact, peak detection of frequency domain is useful for detection of tonal component identified musical note. It is possible to realize high-quality lour bit rate audio.

  • PDF

Adaptive Partial Shading Determinant Algorithm for Solar Array Systems

  • Wellawatta, Thusitha Randima;Choi, Sung-Jin
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1566-1574
    • /
    • 2019
  • Maximum power point tracking (MPPT) under the partial shading condition is a challenging research topic for photovoltaic systems. Shaded photo-voltaic module result in complex peak patterns on the power versus voltage curve which can misguide classical MPPT algorithms. Thus, various kinds of global MPPT algorithms have been studied. These have typically consisted of partial shading detection, global peak search and MPPT. The conventional partial shading detection algorithm aims to detect all of the occurrences of partial shading. This results in excessive execution of global peak searches and discontinuous operation of the MPPT. This in turn, reduces the achievable power for the PV module. Based on a theoretical investigation of power verse voltage curve patterns under various partial shading conditions, it is realized that not all the occurrences of partial shadings require a global peak search. Thus, an intelligent partial shading detection algorithm that provides exact identification of global peak search necessity is essential for the efficient utilization of solar energy resources. This paper presents a new partial shading determinant algorithm utilizing adaptive threshold levels. Conventional methods tend to be too sensitive to sharp shading patterns but insensitive to smooth patterns. However, the proposed algorithm always shows superb performance, regardless of the partial shading patterns.

Accuracy Improvement Methode of Step Count Detection Using Variable Amplitude Threshold (가변 진폭 임계값을 이용한 걸음수 검출 정확도 향상 기법)

  • Ryu, Uk Jae;Kim, En Tae;An, Kyung Ho;Chang, Yun Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.6
    • /
    • pp.257-264
    • /
    • 2013
  • In this study, we have designed the variable amplitude threshold algorithm that can enhance the accuracy of step count using variable amplitude. This algorithm converts the x, y, z sensor values into a single energy value($E_t$) by using SVM(Signal Vector Magnitude) algorithm and can pick step count out over 99% of accuracy through the peak data detection algorithm and fixed peak threshold. To prove the results, We made the noise filtering with the fixed amplitude threshold from the amplitude of energy value that found out the detection error was increasing, and it's the key idea of the variable amplitude threshold that can be adapted on the continuous data evaluation. The experiment results shows that the variable amplitude threshold algorithm can improve the average step count accuracy up to 98.9% at 10 Hz sampling rate and 99.6% at 20Hz sampling rate.

A Series Arc Fault Detection Strategy for Single-Phase Boost PFC Rectifiers

  • Cho, Younghoon;Lim, Jongung;Seo, Hyunuk;Bang, Sun-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1664-1672
    • /
    • 2015
  • This paper proposes a series arc fault detection algorithm which incorporates peak voltage and harmonic current detectors for single-phase boost power factor correction (PFC) rectifiers. The series arc fault model is also proposed to analyze the phenomenon of the arc fault and detection algorithm. For arc detection, the virtual dq transformation is utilized to detect the peak input voltage. In addition, multiple combinations of low- and high-pass filters are applied to extract the specific harmonic components which show the characteristics of the series arc fault conditions. The proposed model and the arc detection method are experimentally verified through a boost PFC rectifier prototype operating under the grid-tied condition with an artificial arc generator manufactured under the guidelines for the Underwriters Laboratories (UL) 1699 standard.

Detection of atrial tachycardia and fibrillation using spectrum analysis of intracardiac signal (Intracardiac Signal의 스펙트럼 분석을 통한 Atrium Tachycardia 및 Fibrillation 검출)

  • Shin, Hang-Sik;Lee, Chung-Keun;Kim, Jin-Kwon;Joo, Young-Min;Lee, Myoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.29-31
    • /
    • 2005
  • Detection methods for atrial tachycardia and fibrillation on the time axis have the advantages of light operational load and are easy to apply to various applications. Despite these advantages, arrhythmia detection algorithm on the time axis cannot stand much noise such as motion artifacts, moreover the peak detection algorithm has high complexity. In this paper, we use a spectrum analysis method for the detection of atrial tachycardia and fibrillation. By applying spectrum analysis and digital filtering on obtained electrogram signals, we can diagnose heart arrhythmia without using peak detection algorithm.

  • PDF

Real time gait analysis using acceleration signal (가속도 신호를 이용한 실시간 보행 분석)

  • Kang, G.T.;Park, K.T.;Kim, G.R.;Choi, B.C.;Jung, D.K.
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.449-455
    • /
    • 2009
  • In this paper, we developed a digital gait analyzer using the triaxial accelerometer(TA). An approach for normal gait detection employing decay slope peak detection(DSPD) algorithm was presented. The TA was attached to the center of the waist of a subject. The subject walked a bare floor at 60, 92 and 120 steps/minute. We analyzed vertical axis acceleration signal for gait detection. At 60, 92, 120 steps/minute walking, detection accuracy of gait events were over 99 % accuracy.

Detection of Atrial Tachycardia and Atrial Fibrillation Using Spectrum Analysis of Intracardiac Signal (Intracardiac Signal의 스펙트럼 분석을 통한 Atrial Tachycardia 및 Atrial Fibrillation 검출)

  • Lee, Chung-Keun;Joung, Bo-Young;Lee, Myoung-Ho;Shin, Hang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.3
    • /
    • pp.142-145
    • /
    • 2006
  • Detection methods for atrial tachycardia and atrial fibrillation on the time axis have the advantages of light operational load and are easy to apply to various applications. Despite these advantages, arrhythmia detection algorithm on the time axis cannot stand much noise such as motion artifacts, moreover the peak detection algorithm has high complexity. In this paper, we use a spectrum analysis method for the detection of atrial tachycardia and atrial fibrillation. By applying spectrum analysis and digital filtering on obtained electrogram signals, we can diagnose heart arrhythmia without using peak detection algorithm.

Regulated Drain Detection and Its Differential PLL Application to Compensate Processes (드레인 정규화 감지회로를 이용한 차동 PLL 설계 및 차동 공정보상기법)

  • Suh, Benjamin;Cho, Hyun-Mook
    • Journal of IKEEE
    • /
    • v.9 no.1 s.16
    • /
    • pp.40-46
    • /
    • 2005
  • A process variation compensation method called 'regulated drain detection' is proposed. This paper also shows the how this newly invented method is applied to a typical differential PLL. The proposed RDD(regulated drain detection) and its PLL application has been designed and tested in a $0.18{\mu}m$ 1-poly 3-metal plain digital process so that its stable performance and higher yield can be proven. The implemented PLL aimed to the operation range of 80MHz - 240MHz and the total die size is only $0.18{\mu}m$ including the internal loop filter. The tracking jitter characteristics is measured to less than 150 peak-to-peak under l.8V supply rail.

  • PDF

Localization of insulation defect applying Threshold-Initial peak detection method (Threshold-Initial peak detection을 이용한 가스 절연 변압기의 절연 결함 위치 판별)

  • Son, Ui-Kwon;Oh, Choong-Seok;Jung, Seung-Yong;Lee, Bang-Wook;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1376-1377
    • /
    • 2008
  • 가스절연변압기(GITr)는 우수한 절연내력과 높은 신뢰성을 장점으로 가지고 있지만, 제작과 운전 단계에서 절연 결함이 발생할 수 있고 이러한 결함들은 가스절연변압기 사고의 원인이 될 수 있다. 따라서 결함에 대한 상시 진단 및 원인 분석이 반드시 선행되어야 하며 이와 같은 진단 분석 기법의 하나로 내부 절연결함의 위치 판별에 대한 연구의 필요성이 절실히 요구되고 있다. 따라서 본 논문에서는 일반적으로 부분 방전의 위치 판별을 위한 time delay 측정법 중 하나인 Cross-correlation 방법과 함께 제안한 Threshold-Initial peak detection 방법을 적용하여 위치 데이터를 취득하고 신뢰구간 이내의 데이터만 사용하여 부분 방전 위치 판별 한 결과, 더욱 정확한 위치 판별이 가능하였다.

  • PDF