• Title/Summary/Keyword: peak current

Search Result 1,752, Processing Time 0.033 seconds

Electrochemical Investigation of Acetaminophen with a Carbon Nano-tube Composite Film Electrode

  • Li, Chunya;Zhan, Guoqing;Yang, Qingdan;Lu, Jianjie
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.11
    • /
    • pp.1854-1860
    • /
    • 2006
  • Electrochemical behaviors of acetaminophen at a muti-wall carbon nano-tube composite film modified glassy carbon electrode were investigated by cyclic voltammetry, linear sweep voltammetry and chronocoulometry. Compared with that obtained at the unmodified electrode, the peak currents were enhanced significantly, and the oxidation peak shifted towards more negative potential with the reduction peak shifted positively. The peak-to-peak separation turned narrow, and suggested that the reversibility was improved greatly. Experimental parameters, such as scan rate, pH and accumulation conditions were optimized. It was found that a maximum current response can be obtained at pH = 5.0 after accumulation at -0.50 V for 80 s. The oxidation peak current was found to be linearly related to acetaminophen concentration over the range of $5.0{\times}10^{-7}\;\sim\;1.0{\times}10^{-4}$ mol $L^{-1}$ with a detection limit of $5.0{\times}10^{-8} $mol $L^{-1}$. A convenient and sensitive electrochemical method was developed for the determination of acetaminophen in a commercial paracetamol oral solution. Its practical application demonstrated that it has good selectivity and high sensitivity.

Analysis of Dynamic Characteristics of Molten Drop and Pulse Condition in Pulsed-GMAW (펄스 GMA용접에서 용융 액적의 동특성 및 펄스 조건에 관한 해석)

  • 최상균;강세령;이상룡
    • Journal of Welding and Joining
    • /
    • v.20 no.4
    • /
    • pp.491-497
    • /
    • 2002
  • Dynamic behavior of the molten drop during the peak period in the pulsed-GMAW is simulated in this work using the VOF(volume of the fluid) algerian. The dynamic characteristics of molten drop such as minimum radius, average velocity and displacement of mass center were computed as well as the internal pressure and velocity. The minimum and maximum peak durations for detaching a drop were calculated.. The result of Analysis reveals that peak current and volume of pendant drop are important factors which affecting drop detachment. A simplified model of constant acceleration is proposed to describe the behavior of molten drop during peak current, and its results agree with the experimental results.

Performance Analysis of the AC-DC Transformation Method using Multi-level Pulsating Current and Selection Switch (다단 맥류 스위칭을 이용한 교류-직류 변환의 성능분석)

  • Lee, Jae-Seang
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.586-593
    • /
    • 2010
  • In this paper, I have proposed that the 1st and 2nd AC-DC transformation methods using multi-level pulsating currents and selection switches. Through making the rectified voltage of the proposed AC-DC translation which is similar to reference voltage by selecting from multi-level pulsating currents, the proposed translation has dramatically reduced the ripple voltage. I have compared the performance of the DC voltage, the ripple voltage and the peak to peak voltage of the proposed method with the conventional method. The simulation results show that the proposed 2nd method has the better performance than the 1st method in the point of average DC voltage drop and peak to peak voltage increase.

A Study on Electrical properties of EPR by Irradiated by X-rays (방사선에 조사된 EPR 의 전기적 특성에 관한 연구)

  • Lee, Sung-Il;Iim, Gui-Yeul;Lee, Ho-Sik;Lee, Hee-Gab
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.565-568
    • /
    • 2002
  • The value of charge current, discharge current, $\varepsilon_r$' $\varepsilon_r"$, residual voltage was measured inorder to investigate electric properties in Ethylene Prophylene Rubber for is irradiated $CO^{60}\gamma$ ray 0-38.1 Mrad. The value of charge current and the discharging current of the EPR is influenced by $CO^{60}-{\gamma}$-irradiation dose The charging current and the discharging current of EPR increase, depending on the ratio of degradation. As the irradiation dose is increased, the peak of residual voltage moves to the slorter time. The properties specific electric constant due to time variation was appeared dispersion by plentiful $CO^{60}-{\gamma}$-irradiation dose. The increase of peak in $\varepsilon_r"$ is attrib uted to the irratiation dose almost proportionally.

  • PDF

Current Reference Compensation for Fast Response in PCMC of PSFB Converter (PSFB 컨버터의 PCMC에서 빠른 응답특성을 가지기 위한 전류 명령 보상)

  • Lee, Jong-Uk;Kim, Hag-Wone;Baek, Seung-Woo;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.147-151
    • /
    • 2018
  • Phase-shift fullbridge (PSFB) converter detects the current in the primary side for operation of the peak current mode controller (PCMC). The PCMC must used the slope compensation to solve the problem when the effective duty is over 0.5. The voltage response of PSFB converters has slower than that of buck converter because of slew interval even if the voltage controllers of two converters have same bandwidth. To overcome these problems, this work proposes a compensating method of current reference considering slew interval and fast response in the PSFB converter. The effectiveness of the proposed method is proven using the PSIM simulation and experiment.

Angular distributions of the critical current of ReBCO coated conductors in magnetic field up to 5T

  • Mineev, Nikolay A.;Rudnev, Igor A.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.1
    • /
    • pp.6-9
    • /
    • 2015
  • For many applications of $ReBa_2Cu_3O_{7-x}$ (ReBCO) tapes it is needed to know the anisotropic properties of the used conductor in a broad range of magnetic field. In this paper we present the results of transport measurements on the SuNAM tape (GdBaCuO) with the rotation of the sample in magnetic fields up to 5 T in liquid nitrogen. The critical current over the magnetic field orientation ($I_c({\theta})$) curves demonstrate the appearance of distinct second peak around c-axis in low fields. This peak almost vanishes in the fields over 3 T. The evolution of the ab-peak form is also presented: the peak consistently reduces its height with the magnetic field going up and in the high fields the shoulders rise, changing the type of the distribution. To describe experimental curves the vortex path model was applied to the angular distributions of the critical current in magnetic field. Good agreements of the experimental data with the analytical expressions were obtained that confirm the vortex path model approach.

Modulation of Calcium Current by Cyclic GMP in the Single Ventricular Myocytes of the Rabbit (토끼 단일 심실근 세포에서 cyclic GMP의 $Ca^{2+}$ 전류 조절기전에 관한 연구)

  • An, Jae-Ho;Seo, Gyeong-Pil;Eom, Yung-Ui
    • Journal of Chest Surgery
    • /
    • v.25 no.4
    • /
    • pp.364-382
    • /
    • 1992
  • In order to investigate the effect of intracellular cyclic GMP on the calcium channel, whole cell patch clamp technique with internal perfusion method was used in the single ventricular myocytes of the rabbit. Cyclic GMP, cGMP analogues, cAMP, isopernaline and forskolin were perfused into cells and their effects on the calcium current were analysed by applying depolarizing step pulse of 10 mV in amplitude for 200 msec from holding potential of -40 mV. Calcium currents usually activated from -30 mV and then reached a peak at +10 mV. Amplitude of the calcium current was standardized with membrane capacitance, 50 pF. Peak amplitude at +10 mV in control was -0.15 nA/50pF. When 100 mM cAMP was applied from the pipette, peak amplitude of calcium current increased to -0.32 nA and addition of 1 mM isoprenaline further increased its amplitude. In the presence of cGMP it alone also produced an increase of the calcium current to -0.52 nA/50pF and addition of isoprenaline or forskolin increased its magnitude to -[0.55~0.95] nA/50pF. Simultaneous application of cGMP and cAMP increased the calcium current to -0.67 nA/50pF. Among the cGMP analogues, 8-Br-cGMP was the most potent stimulant for the calcium current activation. From the above results it could be concluded tlat cGMP increases the calcium current not through cAMP dependent protein kinase nor cAMP dependent phosphodiesterase pathway, but through independent phosphorylation pathway, possibly cGMP dependent protein kinase pathway.

  • PDF

Effects of the Changes of Current Density and Additive Concentration on Ni Thin Films in Ni Sulfamate-chloride Electrodeposition Baths (Ni Sulfamate-chloride 전기도금 용액에서 전류밀도와 첨가제의 농도 변화가 Ni 박막에 미치는 영향)

  • Yoon, Pilgeun;Park, Deok-Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.1
    • /
    • pp.62-70
    • /
    • 2018
  • Sulfamate plating solution containing a small amount of chloride bath was fabricated to study the properties of the electrodeposited Ni thin films. Effects of the changes of current density and additive concentration on current efficiency, residual stress, surface morphology and microstructure of Ni thin films electrodeposited from Ni sulfamate-chloride baths were investigated. The current efficiency was measured to be more than about 95%, independent of the changes of current density and saccharin concentration in the baths. Residual stress of Ni thin film was appeared to be the compressive stress modes in the range of $5{\sim}30mA/cm^2$ current density. Maximum compressive stress was observed at the current density of $10mA/cm^2$. Compressive stress values of Ni thin/thick films were increased to be about -85~-100 MPa with increasing saccharin concentration from 0 to 0.0195 M(4 g/L). Surface morphology was changed from smooth to nodule surface appearance with increasing the current density. Smooth surface morphology of Ni thin films electrodeposited from the baths containing saccharin was observed, independent of the saccharin concentration. Ni thin/thick films consist of FCC(111), FCC(200), FCC(220), FCC(311) and FCC(222) peaks. It was revealed that the FCC(200) peak of Ni thin films is the preferred orientation in the range of $5{\sim}30mA/cm^2$ current density. The intensity of FCC(200) peak was gradually decreased and the intensity of FCC(111) peak was increased with increasing saccharin concentration in the baths.

A study on the CFT error reduction of switched-current system (전류 스위칭 시스템의 CFT 오차 감소에 관한 연구)

  • 최경진;이해길;신홍규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.5
    • /
    • pp.1325-1331
    • /
    • 1996
  • In this paper, a new current-memory circuit is proposed that reduces the clock feedthrough(CFT) error voltage causing total harmonic distortion(THD) increment in switched-current(SI) systems. Using PMOS transistor in CMOS complementary, the proposed one reduces output distortion current due to the CFT errorvoltage. A proposed current-memory is designed using a 1.2.mu.m CMOS process anda 1MHz sinusoidal signal having a 68.mu.A amplitude current is applied as input (sampling frequency:20MHz). It hasbeen shown from the simulation that the output distortion current effected by the CFT error voltage is reduced by approximately 10 times the error voltage of conventional one, THD is -57dB in case ofappling 1kHz frequency input signalwith 0.5 peak signal-to-bias current ratio.

  • PDF