• 제목/요약/키워드: peak current

검색결과 1,759건 처리시간 0.037초

고전계하에서 유전체 전극에 나타나는 코로나 현상 (Corona Discharge Phenomena on the Dielectric Electrodes in High Field)

  • 김정달;이덕진;주성철;정장근;장기혁;이세훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1598-1600
    • /
    • 1998
  • When dielectric surface electric field exceed any electric field strength on air, corona discharge is occurred from the dielectric surface. This paper presents corona discharge phenomena on the dielectric in high field were studied under application of ${\pm}DC$ voltage, constitute of the point to plane 20mm gap. The results obtained in experimental are summarized as follow :(1) Corona pulse is appeared periodically after first corona pulse is occurred and the number of corona pulse increases with the instantaneous applied voltage but peak value is not changed greatly.(2)Applied voltage to beccrite and characteristics and peak value of current are almost a straight line. That kind of tendency accorded with characteristics of beccrite resistance.(3)In case of Positive corona, Positive streamers, were progressed greatly to plane electrodes but In case of negative corona, negative streamers smaller than that of Positive corona.

  • PDF

ANSI/IEEE와 IEC 규격(規格)에 따른 변압기(變壓器)의 단락강도시험(短絡强度試驗)의 비교(比較) (The Study of Comparison with ANSI/IEEE and IEC for Short Circuit Test of Transformers)

  • 김선구;김선호;김원만;나대열;노창일;이동준;정흥수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.705-706
    • /
    • 2006
  • Generally Short Circuit Test of transformers are tested according to IEEE std C57.12.00-2000, IEC 60076-5(2000-07), ES148(1998.6.26) or KS C4309(2003). But ES148(1998.6.26) is same as IEEE std C57. 12.00-2000 and KS C4309(2003) is revising coincidence with IEC 60076-5(2000-07). On this study condition of the transformers before short circuit test, calculation method for test current peak value, tolerance on the asymmetrical peak and r.m.s value, short circuit testing procedure, number of short circuit test, duration short circuit test, and detection of faults and evaluation of short circuit test result will be compared with ANSI and IEC.

  • PDF

Ductility and inelastic deformation demands of structures

  • Benazouz, Cheikh;Moussa, Leblouba;Ali, Zerzour
    • Structural Engineering and Mechanics
    • /
    • 제42권5호
    • /
    • pp.631-644
    • /
    • 2012
  • Current seismic codes require from the seismically designed structures to be capable to withstand inelastic deformation. Many studies dealt with the development of different inelastic spectra with the aim to simplify the evaluation of inelastic deformation and performance of structures. Recently, the concept of inelastic spectra has been adopted in the global scheme of the performance-based seismic design through capacity-spectrum methods. In this paper, the median of the ductility demand ratio for 80 ground motions are presented for different levels of normalized yield strength, defined as the yield strength coefficient divided by the peak ground acceleration (PGA). The influence of the post-to-preyield stiffness ratio on the ductility demand is investigated. For fixed levels of normalized yield strength, the median ductility versus period plots demonstrated that they are independent of the earthquake magnitude and epicentral distance. Determined by regression analysis of the data, two design equations have been developed; one for the ductility demand as function of period, post-to-preyield stiffness ratio, and normalized yield strength, and the other for the inelastic deformation as function of period and peak ground acceleration valid for periods longer than 0.6 seconds. The equations are useful in estimating the ductility and inelastic deformation demands for structures in the preliminary design. It was found that the post-to-preyield stiffness has a negligible effect on the ductility factor if the yield strength coefficient is greater than the PGA of the design ground motion normalized by gravity.

Analysis of High Burnup Fuel Behavior Under Rod Ejection Accident in the Westinghouse-Designed 950 MWe PWR

  • Chan Bock Lee;Byung Oh Cho
    • Nuclear Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.273-286
    • /
    • 1998
  • As there has arisen a concern that failure of the high burnup fuel under the reactivity-insertion accident(RIA) may occur at the energy lower than the expected, fuel behavior under the rod ejection accident in a typical Westinghouse-designed 950 MWe PWR was analyzed by using the three dimensional nodal transient neutronics code, PANBOX2 and the transient fuel rod performance analysis code, FRAP-T6. Fuel failure criteria versus the burnup was conservatively derived taking into account available test data and the possible fuel failure mechanisms. The high burnup and longer cycle length fuel loading scheme of a peak rod turnup of 68 MWD/kgU was selected for the analysis. Except three dimensional core neutronics calculation, the analysis used the same core conditions and assumptions as the conventional zero dimensional analysis. Results of three dimensional analysis showed that the peak fuel enthalpy during the rod ejection accident is less than one third of that calculated by the conventional zero dimensional analysis methodology and the fraction of fuel failure in the core is less than 4 %. Therefore, it can be said that the current design limit of less than 10 percent fuel failure and maintaining the core coolable geometry would be adequately satisfied under the rod ejection accident, even though the conservative fuel failure criteria derived from the test data are applied.

  • PDF

Electrochemical Determination of Artemisinin Using a Multi-wall Carbon Nanotube Film-modified Electrode

  • Yang, Xiaofeng;Gan, Tian;Zheng, Xiaojiang;Zhu, Dazhai;Wu, Kangbing
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권7호
    • /
    • pp.1386-1390
    • /
    • 2008
  • Artemisinin, the effective ingredient of Chinese herb Artemisia annua L (Qinghao in Chinese), has been proved to be effective to antimalarial. Herein, a reliable, sensitive and convenient electrochemical method was developed for the determination of artemisinin utilizing the excellent properties of multi-wall carbon nanotube (MWNT). The electrochemical behavior of artemisinin was investigated. It is found that the reduction peak current of artemisinin remarkably increases and the peak potential shifts positively by 240 mV at the MWNT film-modified electrode. These phenomena indicate that the MWNT film exhibits efficient catalytic activity to the electrochemical reduction of artemisinin. The effects of pH value, amount of MWNT, scan rate and accumulation time were examined. The limit of detection (S/N = 3) is as low as 10 $\mu$ g $L^{-1}$. Finally, this newly developed method was used to determine the content of artemisinin in Artemisia annua L.

Wind Load Combinations Including Torsion for Rectangular Medium-rise Buildings

  • Stathopoulos, T.;Elsharawy, M.;Galal, K.
    • 국제초고층학회논문집
    • /
    • 제2권3호
    • /
    • pp.245-255
    • /
    • 2013
  • This paper presents the results of a set of wind tunnel tests carried out to examine wind-induced overall structural loads on rectangular medium-rise buildings. Emphasis was directed towards torsion and its correlation with peak shear forces in transverse and longitudinal directions. Two building models with the same horizontal dimensions but different gabled-roof angles ($0^{\circ}C$ and $45^{\circ}C$) were tested at different full-scale equivalent eave heights (20, 30, 40, 50, and 60 m) in open terrain exposure for all wind directions (every $15^{\circ}C$). Wind-induced pressures were integrated over building surfaces and results were obtained for along-wind force, across-wind force, and torsional moment. Maximum wind force component was given along with the other simultaneously-observed wind force components normalized by the overall peak. The study found that for flat-roofed buildings maximum torsion for winds in transverse direction is associated with 80% of the overall shear force perpendicular to the longer horizontal building dimension; and 45% of the maximum shear occurs perpendicular to the smaller horizontal building dimension. Comparison of the wind tunnel results with current torsion provisions in the American wind standard, the Canadian and European wind codes demonstrate significant discrepancies. Suggested load combination factors were introduced aiming at an adequate evaluation of wind load effects on rectangular medium-rise buildings.

터렛 계류된 LNG-FSRU의 극한 계류 해석 (Extreme Mooring Analysis of Turret Moored LNG-FSRU)

  • 이민경;정광효;박성부;유병석;정윤석
    • 대한조선학회논문집
    • /
    • 제53권5호
    • /
    • pp.435-446
    • /
    • 2016
  • In this study, hydrodynamic and mooring analysis for LNG FSRU moored by an internal turret with 9 mooring lines are numerically performed using commercial softwares, Hydrostar and Ariane. Met-ocean combinations for screening method are taken from wave governed condition(BV Rule Note NR 493) with relative heading between wave and wind between −45° and +45° and relative heading between wind and current between −30° and +30°. Extreme mooring analysis and sensitivity analysis are performed for intact and damaged (=one line missing) conditions and the parameters for sensitivity analysis are wave peak period, peak enhancement factor and line pretension. In the viewpoint of the design tension in mooring line, chain diameter is designed to satisfy safety factor for each conditions. As the chain diameter is increased from 152mm to 171mm, the designtension is reduced while the minimum breaking load is increased.

리놀산의 산패에 대한 전기화학적 특성 연구 (Studies on the Electrochemical Properties for Rancidity of Linoleic Acid)

  • 김우성;이송주
    • 한국식품영양학회지
    • /
    • 제13권4호
    • /
    • pp.360-364
    • /
    • 2000
  • 유지에 존재하는 linoleic acid의 전기화학적 산화/환원으로부터 속도론적 인자를 예측하고, 시간 변화에 대한 산패 정도를 조사하였다. Linoleic acid의 전기 화학적 산화환원 반응은 비가역적이고, 확산지배적으로 진행됨을 알 수 있고, 주사속도에 따른 결과로부터 확산계수 $D_{o}$ 는 2.61$\times$$10^{-6}$이고, 속도상수 $K^{o}$ 는 9.79$\times$$10^{-11}$로 주어짐을 예측하였다. 또한 linoleic acid의 산화반응 영역과 환원반응 영역에서 작업전극의 선택도가 달라짐을 볼 수 있다. 대기중 방치시간에 따른 시험 결과 방치한 지 4일을 전후로 산화 peak가 최대값으로 주어졌다. 특정 Peak에서 일정전위 전기분해 한 후 전기분해 생성물을 분석한 결과 carbonyl group이 생성됨을 예측할 수 있었다.

  • PDF

시간대별 차등 전기요금을 고려한 최소비용 장비운용계획 (Optimal Machine Operation Planning under Time-based Electricity Rates)

  • 김인호;옥창수
    • 산업경영시스템학회지
    • /
    • 제37권4호
    • /
    • pp.63-71
    • /
    • 2014
  • As power consumption increases, more power utilities are required to satisfy the demand and consequently results in tremendous cost to build the utilities. Another issue in construction of power utilities to meet the peak demand is an inefficiency caused by surplus power during non-peak time. Therefore, most power company considers power demand management with time-based electricity rate policy which applies different rate over time. This paper considers an optimal machine operation problem under the time-based electricity rates. In TOC (Theory of Constraints), the production capacities of all machines are limited to one of the bottleneck machine to minimize the WIP (work in process). In the situation, other machines except the bottleneck are able to stop their operations without any throughput loss of the whole manufacturing line for saving power utility cost. To consider this problem three integer programming models are introduced. The three models include (1) line shutdown, (2) block shutdown, and (3) individual machine shutdown. We demonstrate the effectiveness of the proposed IP models through diverse experiments, by comparing with a TOC-based machine operation planning considered as a current model.

이동 중 주들것에서 심폐소생술 분석 (Analysis of cardiopulmonary resuscitation during main stretcher transport - A manikin study -)

  • 노상균
    • 한국응급구조학회지
    • /
    • 제24권2호
    • /
    • pp.39-50
    • /
    • 2020
  • Purpose: This study aimed to compare the effect of chest compression and the resulting ventilation volume in walking cardiopulmonary resuscitation (CPR), straddling CPR, and mechanical CPR while moving manikins to main stretchers. Methods: We compared the chest compressions in terms of compression depth, number of incomplete releases, complete release depth, compression rate, duration between peak time of previous compression and peak time of current compression, and respiration. We analyzed the compression comparatively with the ventilation volume in three different types of CPR. Results: The chest compression depth was significantly improved during straddling CPR as compared to walking CPR, during which women were unable to achieve sufficient chest compression depth. A constant chest compression depth was maintained during mechanical CPR. Conclusion: High-quality chest compressions were difficult to achieve in moving spaces. Further, walking CPR may be helpful in men, but straddling or applying automatic chest compressions in women would result in more effective CPR. Our findings demonstrate the limitations and trends in administering CPR in men and women, which may be useful in devising better education and training methods in the future.