• Title/Summary/Keyword: peak current

Search Result 1,752, Processing Time 0.026 seconds

Forward-Mode $Na^+-Ca^{2+}$ Exchange during Depolarization in the Rat Ventricular Myocytes with High EGTA

  • Kim, Eun-Gi;Ko, Chang-Mann
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제5권6호
    • /
    • pp.487-494
    • /
    • 2001
  • During depolarization, extrusion of $Ca^{2+}$ from sarcoplasmic reticulum through forward-mode $Na^+-Ca^{2+}$ exchange was studied in the rat ventricular myocytes patch-clamped in whole-cell configuration. In order to confine the $Ca^{2+}$ responses in a micro-domain by limiting the $Ca^{2+}$ diffusion time, rat ventricular myocytes were dialyzed with high (14 mM) EGTA. $K^+$ current was suppressed by substituting KCl with 105 mM CsCl and 20 mM TEA in the pipette filling solution and by omitting KCl in the external Tyrode solution. $Cl^-$ current was suppressed by adding 0.1 mM DIDS in the external Tyrode solution. During stimulation roughly mimicking action potential, the initial outward current was converted into inward current, $47{\pm}1%$ of which was suppressed by 0.1 mM $CdCl_2.$ 10 mM caffeine increased the remaining inward current after $CdCl_2$ in a cAMP-dependent manner. This caffeine-induced inward current was blocked by $1\;{\mu}M$ ryanodine, $10\;{\mu}M$ thapsigargin, 5 mM $NiCl_2,$ or by $Na^+\;and\;Ca^{2+}$ omission, but not by $0.1\;{\mu}M$ isoproterenol. The $I{\sim}V$ relationship of the caffeine-induced current elicited inward current from -45 mV to +3 mV with the peak at -25 mV. Taken together, it is concluded that, during activation of the rat ventricular myocyte, forward-mode $Na^+-Ca^{2+}$ exchange extrudes a fraction of $Ca^{2+}$ released from sarcoplasmic reticulum mainly by voltage-sensitive release mechanism in a micro-domain in the t-tubule, which is functionally separable from global $Ca^{2+}{_i}$ by EGTA.

  • PDF

뇌서지가 ZnO바리스터에 미치는 영향 (Effects of Lightning Surges on the Life of ZnO Varistors)

  • 이봉;이수봉;강성만;이복희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.257-262
    • /
    • 2006
  • To evaluate the change in protective levels of zinc oxide (ZnO) varistors after the surge absorption, this paper investigated the effects of the number of injection and amplitude of lightning surges on the life of ZnO varistors for low voltages. Leakage currents flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages were measured. The surge simulator system ECAT that can generate $8/20{\mu}s$ impulse currents with a peak short-circuit of 5 $[kA_p]$ was used. The ZnO varistor leakage current increases with exposure to impulse current, and the number of injection of $8/20{\mu}s$ impulse currents to breakdown was inversely proportional to the amplitude of the test current. Behaviors of ZnO varistor leakage currents were strongly dependent on the number of injection and amplitude of $8/20{\mu}s$ impulse currents. ZnO varistors degrade gradually when subjected to impulse current, and the resistive leakage current flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages was significantly increased after a certain number of injection that is dependent on the amplitude of the test impulse current. As a result, the life of ZnO varistors mainly depends on the amplitude and occurrence frequency of lightning surges.

YBCO 박막의 저항형 초전도 한류기에 대한 동작 특성 (Operating Properties for a Resistive SFCL of YBCO Thin Films)

  • 최효상;현옥배;김혜림;황시돌;김상준;문승현;한병성
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권10호
    • /
    • pp.537-543
    • /
    • 1999
  • We fabricated a resistive superconducting fault current limiter (SFCL) of a meander type based on a YBCO film with the meander cross section of 5 $\times$ $10^{-6}$$cm^2$, and performed current limitation experiments. The film was coated quench current was 9.6 Apeak at 60 Hz, and the fast quench time was 0.63 msec. The resistance of the limiter continuously increased for three cycles dut to the temperature rise in the gold layer. The temperature of the current limiting element reached the room temperature in 11 msec, $150^{\circ}C$ in 54 msec after quench, and was saturated afterwards. For $45^{\circ}$and $90^{\circ}$faults the fast quench times were 0.56 msec and 0.26 msec, respectively. The quench time is believed to be reduced because the fault occurred when the current was either increasing or at the peak value. This limiter effectively limited the fault current to about 1/5 of the potential current with no SFCL right after the fault and to about 1/8.5 in three cycles. We confirmed that the gold layer effectively carried out the role of heat dissipation as the SFCL was quenched.

  • PDF

Digitally Current Controlled DC-DC Switching Converters Using an Adjacent Cycle Sampling Strategy

  • Wei, Tingcun;Wang, Yulin;Li, Feng;Chen, Nan;Wang, Jia
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.227-237
    • /
    • 2016
  • A novel digital current control strategy for digitally controlled DC-DC switching converters, referred to as Adjacent Cycle Sampling (ACS), is proposed in this paper. For the ACS current control strategy, the available time interval from sampling the current to updating the duty ratio, is approximately one switching cycle. In addition, it is independent of the duty ratio. As a result, the contradiction between the processing speed of the hardware and the transient response speed can be effectively relaxed by using the ACS current control strategy. For digitally controlled buck DC-DC switching converters with trailing-edge modulation, digital current control algorithms with the ACS control strategy are derived for three different control objectives. These objectives are the valley, average, and peak inductor currents. In addition, the sub-harmonic oscillations of the above current control algorithms are analyzed and eliminated by using the digital slope compensation (DSC) method. Experimental results based on a FPGA are given, which verify the theoretical analysis results very well. It can be concluded that the ACS control has a faster transient response speed than the time delay control, and that its requirements for hardware processing speed can be reduced when compared with the deadbeat control. Therefore, it promises to be one of the key technologies for high-frequency DC-DC switching converters.

Operating characteristics of a superconducting DC circuit breaker connected to a reactor using PSCAD/EMTDC simulation

  • Kim, Geon-woong;Jeong, Ji-sol;Park, Sang-yong;Choi, Hyo-sang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권3호
    • /
    • pp.51-54
    • /
    • 2021
  • The DC system has less power loss compared to the AC system because there is no influence of frequency and dielectric loss. However, the zero-crossing point of the current is not detected in the event of a short circuit fault, and it is difficult to interruption due to the large fault current that occurs during the opening, so the reliability of the DC breaker is required. As a solution to this, an LC resonance DC circuit breaker combined a superconducting element has been proposed. This is a method of limiting the fault current, which rises rapidly in case of a short circuit fault, with the quench resistance of the superconducting element, and interruption the fault current passing through the zero-crossing point through LC resonance. The superconducting current limiting element combined to the DC circuit breaker plays an important role in reducing the electrical burden of the circuit breaker. However, at the beginning of a short circuit fault, superconducting devices also have a large electrical burden due to large fault currents, which can destroy the element. In this paper, the reactor is connected to the source side of the circuit using PSCAD/EMTDC. After that, the change of the fault current according to the reactor capacity and the electrical burden of the superconducting element were confirmed through simulation. As a result, it was confirmed that the interruption time was delayed as the capacity of the reactor connected to the source side increased, but peak of the fault current decreased, the zero-crossing point generation time was shortened, and the electrical burden of the superconducting element decreased.

스테인리스 스틸 안정화재를 가진 coated conductor의 적층 유무에 따른 효과적인 사고전류 제한을 위한 연구 (A study on the effective fault current limiting characteristics of stacked coated conductors with stainless steel stabilizer)

  • 나진배;안민철;김민재;김영재;양성은;박동근;김호민;석복렬;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.9-13
    • /
    • 2007
  • Coated conductor(CC) is recently in actively progress for the research and development, and its can be used various stabilizer lot the specific requirements for each application. Among various superconducting applications, coated conductor applied to superconducting fault current limiters(SFCLS) bypasses fault current to its stabilizer, where the surge is abruptly reduced ; thus, stainless steel, which has large resistivity can be a suitable stabilizer for SFCLS. Despite high n-value of the YBCO, CC stabilized with stainless steel did not effectively limit the first peak fault current. In the short circuit test results of AMSC's 344S, a half period delay was observed between the fault and the generation of resistance(60Hz). In this paper, we performed short-circuit experiments with stacked and unstacked CC and compared the test results to analyze effective fault current limiting characteristics. we compared time of the generated resistance as the fault current limiting characteristics and made the samples one is the stacked CC and the other is unstacked CC. These samples were used equal numbers of pieces of CC. In addition, comparison and analysis was made for the stacked structure by measuring fault current limiting characteristics with respect to thermal insulation by impregnating with epoxy resin.

서남해 해상풍력실증단지에서 X-Band Radar로 관측한 유동 및 파랑 자료 검증 (Verification of current and wave data observed with X-band radar at an offshore wind substantiation farm in the Southwest Sea)

  • 최승삼;임은표;이형래;문광석;전인성;김민석
    • 풍력에너지저널
    • /
    • 제15권1호
    • /
    • pp.21-29
    • /
    • 2024
  • In order to respond to environmental changes and various events in the nearby sea area due to the operation of an offshore wind substantiation farm in the Southwest Sea, X-band radar has been installed and operated on a fixed platform since 2018. The X-band radar's monitoring system produces wave and current data through Rutter's Ocean WaveS wave and current (Sigma S6 WaMoS II). In this study, to verify the reliability of the produced data, the accuracy of current and wave data was evaluated by analyzing the correlation with the results obtained by an acoustic doppler current profiler (ADCP). The selected analysis period was a total of 30 days from November 29 to December 28, 2021, the period during which the ADCP survey was conducted. As a result of comparative verification, the current, wave height and peak wave period (Hs > 0.69 m) data observed from the X-band radar showed a high correlation with the results investigated from ADCP. In the future, current and wave data produced by X-band radar are expected to be used as basic data to analyze environmental changes in sea areas and provide information on various events.

열화된 XLPE 케이블의 열지급전류 (Thermally Stimulated Currents in Aged XLPE Cable Insulation)

  • 김상준;이남우;정동원;고인석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.221-223
    • /
    • 1991
  • In order to evaluate degradation of the aged power cables, thin slices(200m) cut from the aged cables were prepared for thermally stimulated current measurements. Throughout the temperature range, 140 to $280^{\circ}C$ the TSC is greater for the aged material, and sharp peak is observed at $158^{\circ}C$ and $210^{\circ}C$.

  • PDF

병렬 연결 배터리 모듈 시스템을 위한 새로운 충.방전기 (A Novel Charger/Discharger for the Parallel Connected Battery Module System)

  • 조윤제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.636-640
    • /
    • 2000
  • A novel integrated battery charger/discharger converter for a standardized battery module is proposed. Instead of using separate charger and discharger converters. it integrates these two converters into a single converter in order to minimize the size. the integrated charger/discharger converter not only regulates the solar array output power including the peak power tracking capability but also controls the battery charging/discharging current depending on the solar array output power and the load power. In addition it offers a regulated bus voltage which simplifies the power distribution/conversion for the pay load.

  • PDF

국내 전력수급 방안 (Electric Power Supply & Demand measures in korea)

  • 이기선
    • 기술사
    • /
    • 제44권2호
    • /
    • pp.29-33
    • /
    • 2011
  • In recent years, maximum electric power demand has been increasing steadily. But, Electric Power Supply & Demand problem is occurring due to lack of electric power reserve ratio caused by electric power peak. For this reason, I investigated the current status of the Electric Power Supply & Demand and established Electric Power Supply & Demand and established Electric Power Supply & Demand measures. I will expect that this paper will be contributed balanced and stable Electric Power Supply & Demand management.

  • PDF