• Title/Summary/Keyword: peak current

Search Result 1,752, Processing Time 0.029 seconds

The Evaluation of Backhaul Transport with ITT Platform - The Case of Busan New Port - (ITT Platform의 복화율 개선에 따른 효과 분석 - 부산항 신항을 대상으로 -)

  • PARK, Nam-Kyu;LEE, Jung-Hun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.2
    • /
    • pp.354-364
    • /
    • 2017
  • This study tries to evaluate the effect of ITT introduction in Busan New Port. The study used the estimation model of the number of vehicles required in accordance with the backhaul rate. The model used big data, COPINO e-document for one year in 2015. COPINO recorded the event such as truck ID, container ID, ATA, damage etc when truck arrived at gate. The study finds important information to estimate the required number of trucks for handling current ITT containers in Busan New Port: Daily throughput in Busan New Port is 1650 vans, especially night throughput recorded peak level in 1800 hours to 2400 hours, the throughput between adjacent terminals recorded high, i.e PNIT to HPNT. The transportation capability for 6 hours between terminals is from 4 vans to 7 vans. The required trucks are estimated 89 currently without considering peak level. If we change the back haul rate from current 20% to 40%, 60% and 80%, how much would the cost drop? It was discovered that, if it is raised to 40%, 60% and 80%, the number of vehicle required will be reduced from 89 (current) to 76, 65 and 59. It was also discovered that the total savings will reduce down to 12%, 25% and 34%.

Emission Characteristics of Multi-Tandem OLED using MoOx with CGL (CGL 층으로 MoOx를 사용한 다중 적층구조 OLED의 발광 특성)

  • Kim, Ji-Hyun;Ju, Sung-Hoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.3
    • /
    • pp.105-109
    • /
    • 2015
  • We studied emission characteristics of blue fluorescent multi-tandem OLEDs using $Al/MoO_x$ as charge generation layer(CGL). Threshold voltage for 2, 3, 4, and 5 units tandem OLEDs was 8, 11, 14 and 18 V, respectively. The threshold voltage in multi-tandem OLEDs was lower than multiple of 4 V for the single OLED. Maximum current efficiency and maximum quantum efficiency of single OLED were 7.6 cd/A and 5.5%. Maximum current efficiency for 2, 3, 4, and 5 units tandem OLEDs was 22.6, 31.4, 41.2, and 46.6 cd/A, respectively. Maximum quantum efficiency for 2, 3, 4, and 5 units tandem OLEDs was 11.8, 15.8, 21.8, and 25.6%, respectively. The maximum current efficiency and maximum quantum efficiency in multi-tandem OLEDs were higher than multiple of those for the single OLED. The intensity for 508 nm peak was changed and the peak wavelength was red shift by increase of tandem unit in electroluminescent emission spectra. These phenomena can be caused by micro-cavity effect with increasing of organic layer thickness.

Design of High Frequency Heating Power Supply System Using Peck Current Mode Control (피크전류모드 제어를 적용한 고주파 심부발열 전원장치 설계)

  • Xu, Guo-Cheng;Zheng, Tao;Piao, Sheng-Xu;Qiu, Wei-Jing;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.61-65
    • /
    • 2017
  • In this paper a prototype of high frequency heating power supply system based on the high frequency heating principle is designed to take the place of acupuncture, moxibustion, warm dressing treatment and some other traditional physical therapy methods. Which possess the advantages of low cost, convenient, easy operation and good effect. The high frequency heating power supply can generate a pulse voltage of more than 1KV with 300KHz switching frequency to heat the patient's skin. The skin temperature can reach to $41{\sim}42^{\circ}C$. The peak current control method is used to maintain the skin temperature in the designed range. The design of the main circuit is based on the flyback converter topology. An easier and practical design method is proposed in this paper. The power supply system prototype is verified to be stable and reliable by both the simulation and experimental results.

A SiC MOSFET Based High Efficiency Interleaved Boost Converter for More Electric Aircraft

  • Zaman, Haider;Zheng, Xiancheng;Yang, Mengxin;Ali, Husan;Wu, Xiaohua
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.23-33
    • /
    • 2018
  • Silicon Carbide (SiC) MOSFET belongs to the family of wide-band gap devices with inherit property of low switching and conduction losses. The stable operation of SiC MOSFET at higher operating temperatures has invoked the interest of researchers in terms of its application to high power density (HPD) power converters. This paper presents a performance study of SiC MOSFET based two-phase interleaved boost converter (IBC) for regulation of avionics bus voltage in more electric aircraft (MEA). A 450W HPD, IBC has been developed for study, which delivers 28V output voltage when supplied by 24V battery. A gate driver design for SiC MOSFET is presented which ensures the operation of converter at 250kHz switching frequency, reduces the miller current and gate signal ringing. The peak current mode control (PCMC) has been employed for load voltage regulation. The efficiency of SiC MOSFET based IBC converter is compared against Si counterpart. Experimentally obtained efficiency results are presented to show that SiC MOSFET is the device of choice under a heavy load and high switching frequency operation.

Properties of thermally stimulated current of PAAS thin film using spin coating method (Spin coating한 polyamic acid alkylamine salt(PAAS) 박막의 열자격 전류 특성)

  • Lee, H.S.;Lee, S.Y.;Lee, W.J.;Kim, T.W.;Kang, D.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1719-1721
    • /
    • 1996
  • This paper describes the thermally stimulated current(TSC) of PAAS spin coated film and the electrical properties of pre TSC measurement and after TSC test specimens. The TSC measurement were performed from room temperature to about $280^{\circ}C$ and the temperature was increased by $5^{\circ}C/min$ automatically. It shows that two peaks of TSC are observed at about $50^{\circ}C$ and about $160^{\circ}C$. Result of this measurement indicate that one peak; $50^{\circ}C$ is from alkyl group; other peak at $160^{\circ}C$ is due to alkyl and C-O group of PAAS. Addition to larger peak at about $160^{\circ}C$ is due to dipolemoment of PAAS film. This result is proved by DSC measurement of PAAS film. The electrical properties of pre and after TSC were measured by currant-voltage(l-V) characteristics. The current-voltage characteristics after TSC specimens are increased the conductivity. The electrical properties of pre-after TSC measurement specimen is in the middle of imidization of PAAS. Because of this result a thermal imidization was performed at $300^{\circ}C$ for 1 hour.

  • PDF

A Study on Bagging Neural Network for Predicting Defect Size of Steam Generator Tube in Nuclear Power Plant (원전 증기발생기 세관 결함 크기 예측을 위한 Bagging 신경회로망에 관한 연구)

  • Kim, Kyung-Jin;Jo, Nam-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.302-310
    • /
    • 2010
  • In this paper, we studied Bagging neural network for predicting defect size of steam generator(SG) tube in nuclear power plant. Bagging is a method for creating an ensemble of estimator based on bootstrap sampling. For predicting defect size of SG tube, we first generated eddy current testing signals for 4 defect patterns of SG tube with various widths and depths. Then, we constructed single neural network(SNN) and Bagging neural network(BNN) to estimate width and depth of each defect. The estimation performance of SNN and BNN were measured by means of peak error. According to our experiment result, average peak error of SNN and BNN for estimating defect depth were 0.117 and 0.089mm, respectively. Also, in the case of estimating defect width, average peak error of SNN and BNN were 0.494 and 0.306mm, respectively. This shows that the estimation performance of BNN is superior to that of SNN.

Sampled-Data Modeling and Dynamic Behavior Analysis of Peak Current-Mode Controlled Flyback Converter with Ramp Compensation

  • Zhou, Shuhan;Zhou, Guohua;Zeng, Shaohuan;Xu, Shungang;Cao, Taiqiang
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.190-200
    • /
    • 2019
  • The flyback converter, which can be regarded as a nonlinear time-varying system, has complex dynamics and nonlinear behaviors. These phenomena can affect the stability of the converter. To simplify the modeling process and retain the information of the output capacitor branch, a special sampled-data model of a peak current-mode (PCM) controlled flyback converter is established in this paper. Based on this, its dynamic behaviors are analyzed, which provides guidance for designing the circuit parameters of the converter. With the critical stability boundary equation derived by a Jacobian matrix, the stable operation range with a varied output capacitor, proportional coefficient of error the amplifier, input voltage, reference voltage and slope of the compensation ramp of a PCM controlled flyback converter are investigated in detail. Research results show that the duty ratio should be less than 0.5 for a PCM controlled flyback converter without ramp compensation to operate in a stable state. The stability regions in the parameter space between the output capacitor and the proportional coefficient of the error amplifier are enlarged by increasing the input voltage or by decreasing the reference voltage. Furthermore, the ramp compensation also can extend to the stable region. Finally, time-domain simulations and experimental results are presented to verify the theoretical analysis results.

Current Limiting Characteristics of a Flux-Lock Type SFCL for a Single-Line-to-Ground Fault

  • Oh, Geum-Kon;Jun, Hyung-Seok;Lee, Na-Young;Choi, Hyo-Sang;Nam, Gueng-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.70-77
    • /
    • 2006
  • We have fabricated an integrated three-phase flux-lock type SFCL, which consists of an YBCO($YB_a2Cu_3O_7$) thin film and a flux-lock reactor wound around an iron core of each phase. In order to apply the SFCL in a real power system, fault analyses for the three-phase system are essential. The short-circuit currents were effectively limited by adjusting the numbers of winding of each secondary coil and their winding directions. The flux flow generated in the iron core cancelled out under the normal operation due to the parallel connection between primary and secondary windings. However, the flux-lock type SFCL with same iron core was operated just after the fault due to the flux generating in the iron core. To analyze the current limiting characteristics, the additive polarity winding was compared with the subtractive one in the flux lock reactor. Whenever a single line-to-ground fault occurred in any phase, the peak value of the line current of the fault phase in the additive polarity winding increased up to about 12.87 times during the first-half cycle. On the other hand, the peak value in the subtractive polarity winding increased up to about 34.07 times under the same conditions. This is because the current flow between the primary and the secondary windings changed to additive or subtractive status according to the winding direction. We confirmed that the current limiting behavior in the additive polarity winding was more effective for a single-line-to-ground fault

Properties of Slow Inward Current in the Rabbit Sinoatrial Node (토끼 동방결절에서의 완만내향전류$(i_{si})$에 관한 연구)

  • Ahn, Kwang-Pil;Lee, Young-Kyun;Earm, Yung-E;Kim, Woo-Gyeum
    • The Korean Journal of Physiology
    • /
    • v.20 no.2
    • /
    • pp.165-174
    • /
    • 1986
  • The voltage clamp studies were undertaken to elucidate the properties of the slow inward current, $i_{si}$, in the small preparations of the rabbit sinoatrial node. The slow inward current, $i_{si}$, which is known to be responsible for the late one-third of pacemaker potential and whole range of upstroke phase of action potential was analysed with the effects of isoprenaline, cobalt, ouabain and higenamine. The results obtained are as follows; 1) Voltage of SA node preparation was held at zero current level, usually-40mV and the slow inward current, $i_{si}$, was activated by depolarizing clamp pulses. Peak values of $i_{si}$, in steady state were at $-10{\pm}0mV$ in most preparations. 2) Isoprenaline, ${\beta}-agonist$ increased $i_{si}$ and no shift was noticed in voltage-dependency. 3) Cobalt ion in the concentration of 1 mM abolished is, in entire range of membrane potential and the difference of two current levels before and after $Co^{2+}$ treatment could be considered as pure $i_{si}$ magnitude. 4) In the therapeutic concentration of ouabain $(5{\times}10^{-8}M)$ slightly increased is, and reduced the time to reach the peak value. 5) Higenamine $(10^{-6}M)$ changed the configurations of action potential (i. e. rapid upstroke phase and notch in the spike) and increase spontaneous rate. It also increased is, and the effect of higenamine was blocked ${\beta}-blocker$, propranolol $(10^{-6}M)$.

  • PDF

Electrical Characteristics of ZnO Surge Arrester Elements Subjected to the Mixed DC and 60[Hz] AC Voltages (직류+60[Hz] 교류 중첩전압에 대한 ZnO 피뢰기 소자의 전기적 특성)

  • Lee, Bok-Hee;Yang, Soon-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.41-47
    • /
    • 2012
  • This paper deals with the electrical characteristics related to power loss, equivalent resistance, and leakage currents flowing through new and deteriorated zinc oxide(ZnO) arrester elements subjected to the mixed DC and 60[Hz] AC voltages. The test specimens were deteriorated by 8/20[${\mu}s$] impulse current of 2.5[kA]. The leakage current-applied voltage($I-V$) characteristic curves of ZnO surge arrester elements were measured as a parameter of the ratio of the peak of 60[Hz] AC voltage to the peak of total voltage. As a consequence of test results, in case of the same applied voltage, the leakage currents flowing through the deteriorated ZnO arrester elements were higher than those flowing through the new ZnO surge arrester elements. The cross-over phenomenon in $I-V$ curves of ZnO surge arrester elements measured as a parameter of the mixed ratio of DC and AC voltages was observed at the low current domain. The effect of DC voltage on the leakage current flowing through ZnO surge arrester elements is pronounced at the same magnitude of test voltages. In addition, the larger the applied number of 8/20[${\mu}s$] impulse current of 2.5[kA] is, the greater the power loss is, in particular, the more severe the power loss increases at higher applied voltages.