• Title/Summary/Keyword: peak current

Search Result 1,752, Processing Time 0.032 seconds

Modeling of Impedance Characteristics of Grounding Electrode for Distribution Line Pole (배전전주의 봉상 접지전극 형태별 임피던스 특성의 모델링)

  • Shim, Keon-Bo;Kim, Kyung-Chul;Lee, Hyung-Soo;Park, Jae-Duck;Choi, Jong-Kee;Park, Sang-Man
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.694-696
    • /
    • 2005
  • Although DC ground resistance is a good index of grounding performance for grounding electrodes, it does not reflect the grounding performance during transient state. Besides, impulse ground impedance, which is defined by a ratio of the peak value of transient ground potential rise to the peak value of impulse current, cannot be an absolute index due to its dependence on impulse current shape. In this paper, ground impedance characteristics of ground electrodes has been measured in frequency domain ranging from 1 Hz to hundreds of kHz. Equivalent circuit models and transfer function models of the ground rod have been identified from the measured values of ground impedance in frequency domain.

  • PDF

Assay of Dinitrotoluene on a Contaminated Soil Sample with an Anodic Stripping Peak Current

  • Ly, Suw-Young;Lee, Chang-Hyun;Jung, Young-Sam
    • Journal of Environmental Science International
    • /
    • v.15 no.11
    • /
    • pp.997-1002
    • /
    • 2006
  • This report presents a voltammetric assay of dinitrotoluene using a DNA immobilized onto a carbon nanotube paste electrode (PE). The cyclic voltammetry (CV) and square wave (SW) stripping voltammetry parameters of the optimized conditions were obtained. An anodic peak current appeared at 0.3 V (versus Ag/AgCl) in a 0.1-M $NH_4H_2PO_4$ electrolyte solution. The detection limit was found to be $0.6ngL^{-1}$(S/N = 10), within a deposition time of 100 sec.

Die-Sinking Electrical Discharge Machining with Dielectric Fluid Ejection System through the Inside of the Electrode (전극봉내 방전유 분산시스템에 의한 형조방전기공)

  • 왕덕현;우정윤
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.1
    • /
    • pp.71-77
    • /
    • 2001
  • Experimental study if die-sinking electrical discharge machining(EDM) was conducted with rotating electrode system including inside hole for increasing the material removal rate(MRR). With the help of dielectric fluid flow through the inside according to the different internal diameter of the hole, the molten workpiece debris could be removed and flushed out during the EDM, Cold die alloy(SKD-1) was executed for different peak current and duty factor. From this study, the MRR was found to be increased with the peak current. The more MRR was obtained for the case of electrode inside diam-eter of 10 mm, but the MRR was decreased as the diameter near at the 4mm and 6mm. The values of surface roughness and roundness were analyzed under various conditions, and these were affected by the inside diameter change of electrode.

  • PDF

I-V characteristics of resonant interband tunneling diodes with single quantum well structure (단일 양자 우물 구조로 된 밴드간 공명 터널링 다이오드의 전류-전압 특성)

  • 김성진;박영석
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.4
    • /
    • pp.27-32
    • /
    • 1997
  • In resonant tunneling diodes with the quantum well structure showing the negative differential resistance (NDR), it is essential to increase both the peak-to-valley current ratio (PVCR) and the peak current desnity ( $J_{p}$) for the accurate digital switching operation and the high output of the device. In this work, a resonant interband tunneling diode (RITD) with single quantum well structure, which is composed of I $n_{0.47}$As/I $n_{0.52}$A $l_{0.48}$As heterojunction on the InP substrate, is fabricated ot improve PVCR and JP, and then the dependence of I-V charcteristics on the width of the quantum well was investigated.d.ted.d.

  • PDF

InGaAs/InAIAs resonant interband tunneling diodes(RITDs) with single quantum well structure (단일양자 우물구조로 된 InGaAs/InAlAs의 밴드간 공명 터널링 다이오드에 관한 연구)

  • Kim, S.J.;Park, Y.S.;Lee, C.J.;Sung, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1456-1458
    • /
    • 1996
  • In resonant tunneling diodes with the quantum well structure showing the negative differential resistance (NDR), it is essential to increase both the peak-to-valley current ratio (PVCR) and the peak current density ($J_p$) for the accurate switching operation and the high output of the device. In this work, a resonant interband tunneling diode (RITD) with single quantum well structure, which is composed of $In_{0.53}Ga_{0.47}As/ln_{0.52}Al_{0.48}As$ heterojunction on the InP substrate, is suggested to improve the PVCR and $J_p$ through the narrowed tunnel barriers. As the result, the measured I-V curves showed the PVCR over 60.

  • PDF

Comparative Analysis of Charging Modes of Series Resonant Converter for an Energy Storage Capacitor (에너지저장 커패시터의 최적 충전을 위한 직렬공진형 컨버터의 운용 모드 비교)

  • Lee, Byung-Ha;Kang, Tae-Sub;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.394-400
    • /
    • 2012
  • In this paper, charging modes of series resonant converter for a high voltage energy storage capacitor are compared in terms of charging time, peak resonant current, normalized peak resonant current and voltage in each operation mode. Operating principles of the full bridge series resonant converter with capacitor load are explained and analyzed in discontinuous and continuous operation mode. Based on the analysis and simulation result, $0.6{\omega}_r$ < ${\omega}_s$ < $0.75{\omega}_r$ and $1.3{\omega}_r$ < ${\omega}_s$ < $1.4{\omega}_r$ are evaluated to the best range of switching frequency for charging of an high voltage energy storage capacitor. 1.8 kJ/s SRC prototype is assembled with TI 28335 DSP controller and 40 kJ, 7 kV energy storage capacitor. Design rules based on the comparative analysis are verified by experiment.

Classification Customer characteristic of Pole-Transformer using Fuzzy Model (퍼지 모델을 이용한 주상 변압기 수용가 특성 구분)

  • Kim, Gi-Hyun;Im, Jin-Soon;Yun, Sang-Yun;Oh, Jung-Hwan;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.276-278
    • /
    • 1999
  • In this paper, we analyze customers' working electric energy (kWh) which is served pole-transformer in order to reduce peak load current error which is generated in application load correlation equation. The characteristic of electric load which customers are using is classified by customer's working electric energy (kWh) and ratio of cooling equipment possession. For the input data of fuzzy model, we used to kWh on April which represents basic load and kWh which is increased from April to August. The April kWh is used to classify into large, medium, small customer. Also, the increased kWh is used to know information of cooling equipment possession. For the output value of fuzzy model, we can determined peak load current limit in application load correlation equation.

  • PDF

A Current-mode peak detector circuit

  • Riewruja, V.;Linthong, A.;Kaewpoonsuk, A.;Guntapong, R.;Supaph, S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.512-512
    • /
    • 2000
  • In this article, a current mode peak detector circuit is presented. The simple circuit configuration comprises four MOS transistors and one external capacitor. The realization method is suitable fur fabrication using CMOS technology and all transistors are operated in their saturation region. The proposed circuit exhibits a very low drop rate and provides high accuracy, high-speed and wide dynamic range. The proposed circuit has very low power dissipation and operates using a single 2.5V supply. Simulation results confirmed the characteristic of the proposed circuit are also included.

  • PDF

A sinusoidal tuned VCO using linear OTA's (선형 OTA를 이용한 사인파 동조형 전압-제어 발전기)

  • 박지만;정원섭
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.7
    • /
    • pp.80-85
    • /
    • 1996
  • A sinusoidal tuned VCO based on linear OTA's has been designed for instrumentation and measurement applications. It consists of a noniverting amplifier, a hard limiter, and a current controlable LC-tuned circuit which is realized vy two linear OTA's and two grounded capacitors. A prototype circuit has been built with discrete components. The experimental results show that the proposed VCO has a linearity error of less than 6.5 percent and a temperature coefficient of less than 200ppm/$^{\circ}C$ over a bias current range form 5$\mu$A to 100 $\mu$A(or an oscillation frequency range form 775.5 Hz to 20.371 kHz). A total harmonic distortion of 0.6 percent was measured for a peak-to-peak amplitude of 5V.

  • PDF

Effect of Radial Rays on Residual Voltage for EPR cable (EPR 케이블의 잔류전압에 미치는 방사선의 영향)

  • 이성일;류성림;김용추
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.518-521
    • /
    • 1999
  • This paper describes the properties of discharge current and the residual voltage for $^{60}$ C$_{0}$ -${\gamma}$ irradiated cables using in nuclear power generating station. As these properties related with $^{60}$ C$_{0}$ -${\gamma}$ -irradiatiation dose, it is suggested that these properties can be utilized as a index of irradiation degradation. As the ratio of degradation increases, the residual voltage in the initial time range increases and the peak moves to the shorter time. Therefore, I know the degree of radiation degradation from the position of the peak.

  • PDF