• 제목/요약/키워드: peak current

검색결과 1,752건 처리시간 0.035초

부하관리 개선을 위한 부하 상관계수 산정에 관한 연구 (Adjustment of load correlation coefficient for advanced load management)

  • 박창호;조성수;김기현;임진순;김두봉;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1267-1269
    • /
    • 1999
  • This paper studies on arrangement of load correlation coefficient for advanced load management. To accurate load correlation coefficient, we used two real factors, electrical energy(kWh) and peak load current of pole transformers, acquired by measuring instrument. Out of several correlation equations, we find that the quadratic equation is the most accurate to express peak load current and working electrical energy. If the data is located in the outside of ${\pm}3{\sigma}$ it is discarded. For load management, we rearranged load correlation coefficient considering +2${\sigma}$ at load correlation equation. Comparing conventional load correlation coefficient with rearranged one, we can get the result of error reduced and it is adjacent to the actual data. It will be used peak load forecasting from working electrical energy and we are able to prevent from the damaging of pole transformer due to overload.

  • PDF

마크 밀도 변화에 강한 버스트 모드 자동 전력 제어 회로 (A Burst-mode Automatic Power Control Circuit Robust io Mark Density Variations)

  • 기현철
    • 대한전자공학회논문지SD
    • /
    • 제41권4호
    • /
    • pp.67-74
    • /
    • 2004
  • 기존의 버스트 모드 자동전력제어 회로는 데이터 율이 증가함에 따라 마크밀도 변화 영향을 심하게 받아 에러를 야기하였다. 이 문제를 해결하기 위해 높은 데이터 율에서도 마크밀도의 영향을 배제시킬 수 있는 새로운 구조의 첨두 비교기를 고안하고 이를 자동전력제어 회로에 적용하여 마크밀도 변화에 강한 버스트 모드 자동전력제어 회로를 제안하였다. 제안한 자동전력제어 회로 내의 첨두 비교기는 높은 데이터 율에서 뿐만 아니라 광범위한 기준전류 및 차 전류 변화에서도 미소한 마크밀도 변화 영향만을 보여 마크밀도 변화에 매우 강한 특성을 확인 할 수 있었다.

Langmuir-Blodgett(LB) 박막의 열자격 전류 연구 (A study on the Thermally stimulated current(TSC) of the Langmuir-Blodgctt(LB) films)

  • 이호식;김우연;이원재;김태완;;강도열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 1996
  • This paper describes the thermally stimulated current (TSC) measurements of arachidic acid and polyamic acid alkylamine salt(PAAS) LB film, which is a precursor of polyimide(PI). The measurements were performed from room temperature to about 25$0^{\circ}C$ and the temperature was increased at a rate of 0.02 K/s linearly. It shows that peaks of TSC are observed at about 8$0^{\circ}C$ in the arachidic acid and about 8$0^{\circ}C$, 16$0^{\circ}C$ in the PAAS LB films. Results of these measurements indicate that one peak at 8$0^{\circ}C$ is resulted from alkyl group; the other peak at 16$0^{\circ}C$ is due to alkyl and C-O group of PAAS. Additional large peak at about 16$0^{\circ}C$ is due to dipole moments in the PAAS films. The DSC and TGA of PAAS, arachidic acid and octadesylamine are measured. Thermal imidization was performed at 30$0^{\circ}C$ far 1 hour by our pre study

  • PDF

Square Wave Voltammetric Determination of Indole-3-acetic Acid Based on the Enhancement Effect of Anionic Surfactant at the Carbon Paste Electrode

  • Zhang, Sheng-Hui;Wu, Kang-Bing
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권9호
    • /
    • pp.1321-1325
    • /
    • 2004
  • Sodium dodecyl sulfate (SDS), an anionic surfactant, can strongly adsorb at the surface of a carbon paste electrode (CPE) via the hydrophobic interaction. In pH 3.0 $Na_2HPO_4$-citric acid buffer (Mcllvaine buffer) and in the presence of SDS, the cationic indole-3-acetic acid (IAA, $pK_a$ = 4.75) was highly accumulated at the CPE surface through the electrostatic interaction between the negative-charged head group of SDS and cationic IAA, compared with that in the absence of SDS. Hence, the oxidation peak current of IAA increases greatly and the oxidation peak potential shifts towards more negative direction. The experimental parameters, such as pH, varieties of surfactants, concentration of SDS, and scan rate were optimized for IAA determination. The oxidation peak current is proportional to the concentration of IAA over the range from $5\;{\times}\;10^{-8}$ mol/L to $2\;{\times}\;10^{-6}$ mol/L. The detection limit is $2\;{\times}\;10^{-8}$ mol/L after 3 min of accumulation. This new voltammetric method was successfully used to detect IAA in some plant leaves.

절연용 실리콘 고무의 열자격 전류에 미치는 $SiO_2$의 영향 (The Effect of $SiO_2$ Affect to Thermally Stimulated Current of Insulating Silicone Rubbers)

  • 이성일
    • 한국안전학회지
    • /
    • 제11권2호
    • /
    • pp.60-66
    • /
    • 1996
  • In order to look into the internal structure and electrical properties of insulating Silicone rubbers added reinforcing fillers ; Silica(0-140 phr ), and to examine the behavior of charged particles, and the properties of thermally stimulated current (TSC) are investigated, respectively. From the TSC which are formed by applying the electric field of 2~5 ㎸/mm to specimen at temperature range from -150 to $270^{\circ}C$, the results arp as following. In the case of non-filled specimen, four peaks of $\delta$, $\gamma$ , $\beta$ and u are obtained at the temperature of $-120^{\circ}C$, $-60^{\circ}C$, $20^{\circ}C$ and $130^{\circ}C$, respectively and the case of filled specimen, three peaks of $\delta$, ${\alpha}_2$ and ${\alpha}_1$ are observed at the temperature of of $-120^{\circ}C$, $80^{\circ}C$ and $130^{\circ}C$, respectively. The origins of these peaks are that, the $\delta$ peak seems to the result from the contribution of side chain methyl radical, and the $\beta$ peak from the depolarization of space charge polarization owing to added imputity during during manufacturing specimens, and the $\beta$ peak from the orientation of $Si-CH_3$dipole, and the ${\alpha}_2$ near the temperature of $130^{\circ}C$ from carboxyl acid that is formed by the thermal oxidation of high temperature.

  • PDF

고속도금된 3가 크롬도금의 전류효율 및 조직특성에 미치는 첨가제의 영향 (The Effect of Additives on the Current Efficiency and the Microstructure of Trivalent Cr Electrodeposits Plated in Flow Cell System)

  • 예길촌;서경훈
    • 한국표면공학회지
    • /
    • 제37권2호
    • /
    • pp.92-98
    • /
    • 2004
  • The current efficiency and the microstructure of the trivalent Cr deposits plated in flow cell system were investigated according to additives in sulfate bath and current density. The current efficiency of the deposits plated in the formic acid complexed bath was noticeably higher than that of the deposits from glycine complexed bath. The current efficiency of the deposits from the complexed baths with boric acid buffer increased linearly with current density in the range of 60-100 A/dm$^2$, while that of the deposits from the baths with both Al sulfate and mixed buffers increased parabolically with current density. The nodular crystallite size of the deposits increased with current density, and the deposits plated in low current density region had relatively smooth surface appearance with fine grains. The structure of the deposits from the complexed baths with boric acid buffer changed from amorphous structure to crystalline one with strong (110)peak with increasing current density. The deposits from the baths with both Al sulfate and mixed buffers had generally amorphous structure.

Biomechanical Effectiveness of the Low-Dye Taping on Peak Plantar Pressure During Treadmill Walking Exercise in Subjects With Flexible Flatfoot

  • Lim, One-Bin;Kim, Jeong-Ah;Kwon, Oh-Yun;Yi, Chung-Hwi
    • 한국전문물리치료학회지
    • /
    • 제22권2호
    • /
    • pp.41-51
    • /
    • 2015
  • The purposes of this study were 1) to determine the effects of low-dye taping on peak plantar pressure following treadmill walking exercise, 2) to determine whether the biomechanical effectiveness of low-dye taping in peak plantar pressure was still maintained following removal of the tape during treadmill walking, and 3) to determine the trend towards a medial-to-lateral shift in peak plantar pressure in the midfoot region before and after application of low-dye taping. Twenty subjects with flexible flatfoot were recruited using a navicular drop test. The peak plantar pressure data were recorded during five treadmill walking sessions: (1) un-taped, (2) baseline-taped, (3) after a 10-minute treadmill walking exercise, (4) after a 20-minute treadmill walking exercise, and (5) after removal of the taping. The foot was divided into six parts during the data analysis. One-way repeated measures analysis of variance was performed to investigate peak plantar pressure variations in the six foot parts in the five sessions. This study resulted in significantly increased medial forefoot peak plantar pressure compared to the un-taped condition (p=.017, post 10-minute treadmill walking exercise) and (p=.021, post 20-minute treadmill walking exercise). The peak plantar pressure in the lateral forefoot showed that there was a significant decrease after sessions of baseline-taped (p=.006) and 10-minute of treadmill walking exercise (p=.46) compared to the un-taped condition. The tape removal values were similar to the un-taped values in the five sessions. Thus, the findings of the current study may be helpful when researchers and clinicians estimate single taping effects or consider how frequently taping should be replaced for therapeutic purposes. Further studies are required to investigate the evidence in support of biomechanical effectiveness of low-dye taping in the midfoot region.

스파크 플러그를 이용한 혼합기 농도 측정 (Measurements of Mixture Strength Using Spark Plug)

  • 조상현;임명택
    • 한국자동차공학회논문집
    • /
    • 제8권4호
    • /
    • pp.18-25
    • /
    • 2000
  • Ion current in an S.I engine cylinder is measured with the spark plug as a probe. The peak values are confirmed to show a fair correlation with local air-fuel ration and engine speed which implies that the ion current measured at the spark plug may provide a signal for the local mixture strength which is the key parameter in precise fuel control for future engines especially of gasoline direct-injected lean burn engines.

  • PDF

글로우방전 가스크로마토그라프 검출기에서 방전가스의 영향 (Effect of Discharge Gas on the Electrical Characteristics of the Glow Discharge Plasma for the Gas Chromatographic Detector)

  • 박현미;강종성;김효진
    • 약학회지
    • /
    • 제39권5호
    • /
    • pp.480-486
    • /
    • 1995
  • The change in discharge current of a glow discharge has been shown the potential sensitive detector for gas chromatography. To investigate the effect of carrier gas on the electrical characteristics of the discharge and the peak response, the discharge pressure, gas flow rate, and discharge gap have been studied. The discharge gas included the Ar, He, and N$_{2}$. The gas flow rate has been found one of the important parameters to affect both the electrical characteristics and the peak response.

  • PDF