• Title/Summary/Keyword: peak

Search Result 18,462, Processing Time 0.045 seconds

A Study on Radiation Quality of the Diagnostic X-ray Equipments (진단용(診斷用) X-선장치(線裝置)의 선질(線質) 특성(特性)에 관(關)한 연구(硏究))

  • Park, Myeong-Hwan;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.55-59
    • /
    • 1997
  • The quality of continuous X-ray beam depends upon the half value layer which varies according to the geometric conditions, filtration thickness, and tube voltage. We compared the inverter type X-ray equipment with the conventional single phase 2 peak and the three phase 12 peak for the quality obtained by changes of the added filter thickness and the tube voltage. The quality of single phase 2 peak X-ray generator showed increase for the added filter and the tube volt-age. The half value layer is Increased the thicker the filter and the higher the kVp. The quality of the Inverter type and the three phase 12 peak in comparison with the single phase 2 peak X-ray generator is increased.

  • PDF

Seasonal Occurrence of the Tobacco Moth, Ephestia elutella Hubner (Lepidoptera : Pyralididae). (다색알락명나방의 발생소장에 관한 연구)

  • 오명희;김상석;부경생
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.5 no.1
    • /
    • pp.11-17
    • /
    • 1983
  • The tobacco moth, Ephestia elutella Hubner (Lepidoptera: Pyralididae), was first reported one of the serious of stored tobacco in Korea in 1939 (8). In recent years, tobacco moth lavae were observed infesting in all of the tobacco storage warehouses in this Country. Adults of the tobacco moth for the seasonal occurrence were studied in the three and four regions in 1981 and 1982, respectively. This species was caught from early May to late October in all regions for both years. In 1981, the first emergence peak was in late May to late at Andong, early June at Suweon and the second one in middle August in both regions. In 1982, on the other hand, there were three peak times, late May and July, and middle September. But the relate size of the peaks was different in two years; the second peak showed about 66% of the total number of tobacco moths captured in the whole year in 1981 at Suweon and 59% of those at Andong, while the first peak had 32% at Suweon and 57% at Shintanjin in 1982. This difference in relative peak sizes was discussed.

  • PDF

Valence Band Photoemission Study of the Kondo Insulator CeNiSn

  • Kang, J.S.;Olson, C.G.;Ouki, Y.
    • Journal of Magnetics
    • /
    • v.2 no.4
    • /
    • pp.111-115
    • /
    • 1997
  • The electronic structure of the Kondo insulator CeNiSn has been investigated by using photoemission spectroscopy. A satellite feature is observed in the valence band spectrum about 6 eV below the Ni 3d main peak, indicating a strong Ni 3d Coulomb correlation in CeNiSn. The Ce 4f partial spectral weight exhibits three peak structures, including one due to the 4f1\longrightarrow4f0 transition, another near EF, and the other which overlaps the Ni 3d main peak. We interpret the peak near EF as reflecting mainly the Ce 4f/Sn 5p hybridization, whereas that around the ni 3d main peak as reflecting both the Ce 4f/Ni 3d and Ce 5d/Ni 3d hybridization. Yield measurements across the 4d\longrightarrow4f threshold indicate the Ce valence to be close to 3+. The prominent Fermi edge suggests a metallic ground state in CeNiSn.

  • PDF

Partial Shift Mapping for PAPR Reduction with Low Complexity in OFDM Systems

  • Ouyang, Xing;Jin, Jiyu;Jin, Guiyue;Wang, Zhisen
    • ETRI Journal
    • /
    • v.34 no.2
    • /
    • pp.268-271
    • /
    • 2012
  • The high peak-to-average power is one of the main drawbacks in OFDM systems. This letter proposes a partial shift mapping (PSM) method for peak power reduction in OFDM systems. By utilizing the properties of the discrete Fourier transform, the proposed method generates a set of candidate signals without additional complex multiplication and selects the one with minimum peak power for transmission. Analyses and simulations confirm that the PSM method achieves satisfactory peak power reduction performance and low complexity compared with other kindred methods, for example, selected mapping and partial transmit sequences.

Novel Peak-to-Average Power Ratio Reduction Methods for OFDM/OQAM Systems

  • Sandeep, Vangala;Anuradha, Sundru
    • ETRI Journal
    • /
    • v.38 no.6
    • /
    • pp.1124-1134
    • /
    • 2016
  • The tone reservation method is one of the most effective pre-distortion methods for peak-to-average power ratio reduction in orthogonal frequency division multiplexing (OFDM) systems. Its direct application to OFDM systems with offset quadrature amplitude modulation (OQAM) is, however, not effective. In this paper, two novel TR-based methods are proposed, specifically designed for OFDM/OQAM systems by taking into consideration the overlapping nature of OQAM signals. These two methods have different approaches to the generation of the peak-cancelling signal. The first one (overlapped scaling tone reservation) generates the peak-cancelling signal using a least squares approximation algorithm with possible adjacent symbol overlap; the second one (multi-kernel tone reservation) generates the peak-cancelling signal by using multiple impulse-like time domain kernels. It is shown by simulation that, when used in OFDM/OQAM systems, the proposed methods can provide better performance than the direct application of the existing controlled clipping tone reservation method, and even outperform the multi-block tone reservation method.

Clock Scheduling and Cell Library Information Utilization for Power Supply Noise Reduction

  • Kim, Yoo-Seong;Han, Sang-Woo;Kim, Ju-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.1
    • /
    • pp.29-36
    • /
    • 2009
  • Power supply noise is fundamentally caused by large current peaks. Since large current peaks are induced by simultaneous switching of many circuit elements, power supply noise can be minimized by deliberate clock scheduling which utilizes nonzero clock skew. In this paper, nonzero skew clock scheduling is used to avoid the large peak current and consequently reduce power supply noise. While previous approaches require extra characterization efforts to acquire current waveform of a circuit, we approximate it only with existing cell library information to be easily adapted to conventional design flow. A simulated annealing based algorithm is performed, and the peak current values are estimated for feasible clock schedules found by the algorithm. The clock schedule with the minimum peak current is selected for a solution. Experimental results on ISCAS89 benchmark circuits show that the proposed method can effectively reduce the peak current.

A Fast Response Integrated Current-Sensing Circuit for Peak-Current-Mode Buck Regulator

  • Ha, Jung-Woo;Park, Byeong-Ha;Kong, Bai-Sun;Chun, Jung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.810-817
    • /
    • 2014
  • An on-chip current sensor with fast response time for the peak-current-mode buck regulator is proposed. The initial operating points of the peak current sensor are determined in advance by the valley current level, which is sensed by a valley current sensor. As a result, the proposed current sensor achieves a fast response time of less than 20 ns, and a sensing accuracy of over 90%. Applying the proposed current sensor, the peak-current-mode buck regulator for the mobile application is realized with an operating frequency of 2 MHz, an output voltage of 0.8 V, a maximum load current of 500 mA, and a peak efficiency of over 83%.

Sulfur Redox Equilibrium in Mixed Alkali Silicate Glass Melts

  • Kim, Ki-Dong;Hwang, Jong-Hee
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.3
    • /
    • pp.205-210
    • /
    • 2011
  • The dependence of sulfur redox behavior and its diffusivity on temperature and composition was studied in mixed alkali silicate melts by means of square wave voltammetry (SWV) at different frequencies in a temperature range of $1000^{\circ}C$ to $1400^{\circ}C$. The voltammograms showed two reduction peaks at high frequency but only one peak at low frequency. Irrespective of $K_2O/(Na_2O+K_2O)$, each peak potential due to reduction of $S^{6+}$ to $S^{4+}$ and $S^{4+}$ to $S^0$ moved toward a negative direction with temperature decrease, and the peak current showed a strong dependence on frequency at a constant temperature. However, the compositional dependence of the peak potential showed an inconsistent behavior with an increase of $K_2O$. The mixed alkali effect was not observed in sulfur diffusion. This inconsistency of both peak potential and diffusion for compositional dependence may be derived from the strong volatilization of sulfur in melts.

The research on supporting method of electric peak management for building facilities of heating and cooling (건물냉난방설비관련 전력피크관리사업 지원방안 연구)

  • Yang, Seung-Kwon;Lee, Han-Byul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.379-382
    • /
    • 2008
  • This paper gives the support method of DSM program(power load leveling for heating and cooling facilities on building). As the national power peak load increases recently, the peak load reduction is needed. So we studied about remote controlling of power load from heating/cooling facilities on building during peak times. To adopt new DSM program, it is very important to design DSM customer supporting system. So in this paper, we dealt with the result of customer survey, and the DSM potential regarding heating/cooling facilities on building. In conclusion, the peak reduction program of heating/cooling facilities is very important and the incentive of customer should be consist of two incentive types as an installation and power reduction.

  • PDF

Peak Power Optimization for Metro Railway using by Source Impedance Control (전원 임피던스 제어를 통한 도시철도 최대전력 최적화)

  • Kim, Han-Su;Kwon, Oh-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.841-849
    • /
    • 2014
  • Urban railway with rectifiers is connected by parallel circuits because substations are joined by the power rail. Thus, if an input voltage of a substation is increased, then the voltage of rectifiers is also increased, and which leads to an increase in the peak power of the substation. To solve this problem, this paper proposes a new method reducing the peak power of substations by adjusting the operation number of rectifiers. Its feasibility is exemplified by some simulations performed for Incheon subway Line 1 and GA(Genetic Algorithm) method has been applied to obtain the optimal input. Simulation results show that peak power can significantly be reduced using the method proposed in this paper.