• Title/Summary/Keyword: patient moving

Search Result 209, Processing Time 0.026 seconds

A Study on the Design Qualification of an Isolation Hospital According to Circulation System (동선계획에 따른 격리병동의 설계검증에 관한 연구)

  • Park, Hyun-Jin;Jung, Chung-Soo;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.7
    • /
    • pp.520-527
    • /
    • 2011
  • Recently, Influenza(AI, PI) patients have been increasing rapidly. But, there is a lack of isolation hospitals. In particular, according to increase the rate of patients with airborne infection, in order to prevent the spread of pathogens, design of layout plan and air conditioning system of isolation hospitals becomes more important to maintain patient's room as negative pressure. In this study, the spread of pathogens are analyzed as room differential pressure, moving time of medical staff and patients, and moving way in isolation hospitals by multizone simulation; CONTAM 2.4. Through the analysis, the ways to improve isolation hospital considered at the design step are reached to prevent the spread of pathogens effectively. Also, it verifies that HVAC system for isolation hospital is suitably designed as standard.

A Study on Locational Control of Motion Ghost in Magnetic Imaging System (자기공명영상장치(磁氣共鳴映像裝置)에서 움직임허상(虛像)의 위치제어(位置制御)에 관(關)한 연구(硏究))

  • Lee, Who-Min
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.19-26
    • /
    • 1993
  • Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.

  • PDF

A feasibility study of audio-video communication application using mobile telecommunication in inter-hospital transfer situations (병원 간 전원 상황에서 이동통신망을 이용한 음성화상정보통신 애플리케이션의 유용성에 관한 연구)

  • Jeong, Joo;Kim, Tae-Han;Kang, Saee-Byel
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.1
    • /
    • pp.125-134
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the usefulness of video communication with medical staff located at a remote location, through a communication application connected to a long term evolution (LTE) mobile communication network in a moving ambulance. Methods: In this study, we recruited patients who were transferred by mobile intensive care unit ambulance from one hospital to another. In the moving ambulance, the information of the patient was transferred to a physician using the application in real time. Recorded video files were evaluated by emergency physicians with experience in video direct medical control. Results: A total of 18 patients were evaluated, and the average score was 5.9 out of a possible 9. It was expected that applying the use of the technology to actual clinical sites would enable the sites to provide assistance. Conclusion: In this study, we confirmed the possibility of benefiting from the clinical field when using the video-audio communication application which is connected to the remote location in real time through the current LTE mobile communication network in the ambulance.

Verification of X-sight Lung Tracking System in the CyberKnife (사이버나이프에서 폐종양 추적 시스템의 정확도 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Cho, Sam-Ju;Min, Chul-Ki;Cho, Kwang-Hwan;Lee, Sang-Hoon;Choi, Jin-Ho;Lim, Sang-Wook;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.174-179
    • /
    • 2009
  • To track moving tumor in real time, CyberKnife system imports a technique of the synchrony respiratory tracking system. The fiducial marker which are detectable in X-ray images were demand in CyberKnife Robotic radiosurgery system. It issued as reference markers to locate and track tumor location during patient alignment and treatment delivery. Fiducial marker implantation is an invasive surgical operation that carries a relatively high risk of pneumothorax. Most recently, it was developed a direct lung tumor registration method that does not require the use of fiducials. The purpose of this study is to measure the accuracy of target applying X-sight lung tracking using the Gafchromic film in dynamic moving thorax phantom. The X-sight Lung Tracking quality assurance motion phantom simulates simple respiratory motion of a lung tumor and provides Gafchromic dosimetry film-based test capability at locations inside the phantom corresponding to a typical lung tumor. The total average error for the X-sight Lung Tracking System with a moving target was $0.85{\pm}0.22$ mm. The results were considered reliable and applicable for lung tumor treatment in CyberKnife radiosurgery system. Clinically, breathing patterns of patients may vary during radiation therapy. Therefore, additional studies with a set real patient data are necessary to evaluate the target accuracy for the X-sight Lung Tracking system.

  • PDF

Load-balanced multi-agent model for moving patient management in mobile distribution environment (모바일 분산 환경에서 이동형 환자관리를 위한 부하 균형 다중 에이전트 모델)

  • Lee, Mal-Rye;Kim, Eun-Gyung;Zang, Yu-Peng;Lee, Jae-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.809-816
    • /
    • 2010
  • This paper proposed about a load-balanced multi-agent model in mobile distribution environment to monitor moving patients and to deal with a situation of emergency. This model was designed to have a structure based on distribution framework by expanding a mobile system, and provides healthcare services based on real time situational information on moving patients. In order to overcome the limitation of middleware when we design system, we provided an abstract layer between applications and their base network infrastructure so that balance between QoS requests and network life can be maintained. In addition, clustering was used in cells for the efficient load distribution among multi-agents. By using Clustering FCM, we got optimal resources and had solve about transmission delay.

The Effect of Visual Feedback Training on Balance and ADL in Cerebellar Ataxia : Case Report (시각되먹임 훈련이 소뇌 실조증 환자의 균형과 일상생활 수행에 미치는 영향 : 사례보고)

  • Yang, Hyun-Ju;Cho, Ba-Hoe;Jang, Jong-Sik
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.3 no.1
    • /
    • pp.43-53
    • /
    • 2013
  • Objective : The aim of this study was to identify the effect of visual feedback on balance and ADL in patient with cerebellar ataxia. Method : Between May of 2013, visual feedback applied to cerebellar ataxia patient. The visual feedback applied five times a week for two weeks to patient who are inpatients of Dae-jeon. To assess changes in balance, we performed the LOS, Romberg, BBS, We also assessed ADL using Canadian occupational performance measure(COPM). Result : For the patient of cerebellum ataxia, we can confirm the limitation of stability, and after the intervention, we can check out the changes which are maintained at Romberg test and Berg Balance Scale. In terms of daily activities, such as taking bath, moving to somewhere, using transportation, doing the laundry, and meeting activity, the level of performance and satisfaction has increased in all five fields. Conclusion : After the visual biofeedback training, patients with cerebellar Ataxia showed more increase in balance and ADL.

  • PDF

Development of Frozen Shoulder Rehabilitation Robot Based On Motion Capture Data (모션 캡쳐 데이터 기반의 오십견 재활 보조용 로봇의 개발)

  • Yang, Un-Je;Kim, Jung-Yup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.1017-1026
    • /
    • 2012
  • In this study, an exoskeleton-type robot is developed to assist frozen shoulder rehabilitation in a systematic and efficient manner for humans. The developed robot has two main features. The first is a structural feature: this robot was designed to rehabilitate both shoulders of a patient, and the three axes of the shoulder meet at one point to generate human-like ball joint motions. The second is a functional feature that is divided into two rehabilitation modes: the first mode is a joint rehabilitation mode that helps to recover the shoulder's original range of motion by moving the patient's shoulder according to patterns obtained by motion capture, and the second mode is a muscle rehabilitation mode that strengthens the shoulder muscles by suitably resisting the patient's motion. Through these two modes, frozen shoulder rehabilitation can be performed systematically according to the patient's condition. The development procedure is described in detail.

Long-Term Management of a Refractory Corticosteroid Responsive Tremor Syndrome

  • Kim, Soomin;Kim, Yoonji;Kim, Ji-Hee;Kim, Hyeon-Jin;Lee, Ji-Hye;Geum, Migyeong;Kim, Ha-Jung
    • Journal of Veterinary Clinics
    • /
    • v.38 no.3
    • /
    • pp.143-146
    • /
    • 2021
  • A 2-year-old intact female Maltese dog was presented with generalized involuntary tremors and nystagmus without regular direction. The dog was conscious the whole time while it was trembling. Its involuntary tremors were alleviated at rest or during sleep. Magnetic resonance imaging (MRI) revealed asymmetric hydrocephalus and caudal occipital malformation. In cerebrospinal fluid (CSF) analysis, a trace of protein was found and total nucleated cell count (TNCC) was slightly increased. However, infectious pathogens were not found. In complete blood count, there was a mild leukocytosis. After the patient received anticonvulsants (midazolam, phenobarbital, KBr), diuretics (furosemide) with an anti-inflammatory drug (prednisolone, 0.5 mg/kg PO bid), and a proton-pump inhibitor (omeprazole), it showed no improvement. The patient was tentatively diagnosed with corticosteroid responsive tremor syndrome. So the anticonvulsants and diuretics were discontinued and the dose of prednisolone was increased to an immunosuppressive dose (1 mg/kg PO bid). After administering the immunosuppressive dose of prednisolone, the patient did not show nystagmus. Its tremors were much alleviated. However, they did not disappear. Five weeks later, the patient showed gradual improvement but still was trembling when moving around. Nine weeks later, its tremors were similar to before. So diazepam (0.3 mg/kg PO sid) was added to the treatment. After that, its tremors were alleviated more. Prednisolone and diazepam were maintained for about five months, with tapering of the dose of prednisolone (until 0.5 mg/kg PO sid). About 7 months later after the treatment was started, the dog was trembling rarely except when it was excited. Therefore, diazepam was discontinued. This case describes a refractory white dog shaker syndrome successfully managed with long-term administration of a steroid and diazepam.

The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT (심근관류 SPECT에서 움직임 보정 방법들의 비교)

  • Park, Jang-Won;Nam, Ki-Pyo;Lee, Hoon-Dong;Kim, Sung-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose Patient motion during myocardial perfusion SPECT can produce images that show visual artifacts and perfusion defects. This artifacts and defects remain a significant source of unsatisfactory myocardial perfusion SPECT. Motion correction has been developed as a way to correct and detect the patient motion for reducing artifacts and defects, and each motion correction uses different algorithm. We corrected simulated motion patterns with several motion correction methods and compared those images. Materials and Methods Phantom study was performed. The anthropomorphic torso phantom was made with equal counts from patient's body and simulated defect was added in myocardium phantom for to observe the change in defect. Vertical motion was intentionally generated by moving phantom downward in a returning pattern and in a non-returning pattern throughout the acquisition. In addition, Lateral motion was generated by moving phantom upward in a returning pattern and in a non-returning pattern. The simulated motion patterns were detected and corrected similarly to no-motion pattern image and QPS score, after Motion Detection and Correction Method (MDC), stasis, Hopkins method were applied. Results In phantom study, Changes of perfusion defect were shown in the anterior wall by the simulated phantom motions, and inferior wall's defect was found in some situations. The changes derived from motion were corrected by motion correction methods, but Hopkins and Stasis method showed visual artifact, and this visual artifact did not affect to perfusion score. Conclusion It was confirmed that motion correction method is possible to reduce the motion artifact and artifactual perfusion defect, through the apply on the phantom tests. Motion Detection and Correction Method (MDC) performed better than other method with polar map image and perfusion score result.

  • PDF

Advanced airway management for the prehospital traumatic patient (병원 전 환경의 외상성 응급환자를 위한 전문기도관리)

  • Shim, Gyu-Sik;Kim, Eun-Mee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2360-2367
    • /
    • 2013
  • The purpose of this study was to improve the paramedics skills to manage advanced airway by comparing speed and success rate between endotracheal intubation and laryngeal mask airway(LMA) insertion in a moving ambulance. Sixty subjects were randomly recruited and samely divided into control group and experimental group. And they were asked to join a practical experiment using dummy model. Data analysis was done by SPSS WIN 14.0 Version. As a result of this research, in terms of difference in speed according to patient's intubation posture, the speed of control group was indicated to be good in sniffing position(t=-4.038, p<.001). There was no difference in speed between two groups in neutral position. In the neutral posture given the endotracheal intubation, tooth fracture occurred in 16 people(53.3%). There was no difference in success rate between two groups. As for a change in self-confidence before and after experiment, the post self-confidence was indicated to have been enhanced in both groups. In conclusion, it is effective to use LMA in the traumatic patient who is unable to receive endotracheal intubation in sniffing position. It is very important for the paramedics to receive the continuous training of the airway management skills.