정류방식에 따른 진단용 X-선 장치의 출력비교 (A Comparative Study on Output of Four Type Diagnostic X-ray Equipments)

  • 김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.34-43
    • /
    • 1997
  • There are 4 types of equipment in diagnostic radiography. These are single phase, three phase, inverter type and condenser type X-ray generators. It is very confusing to make an adequate exposure factor and to know the usage of different type of X-ray generators. In this experiment, I explored a comparative study of outputs in 4 different type of X-ray units. I expect that this experiment could be helpful for manufacturer to make both the X-ray equipment better, In terms of Ideal exposure factors, thereby reducing the patient dose. Experimental results are as follow : 1) X-ray output The ratio of X-ray output of single, three phase and inverter type of X-ray generator was 1 : 1.6 : 2 without absorber and 1 : 2 : 2.6 with 20 mm aluminium absorber. 2) Beam quality The X-ray beam quality of single phase generator was proved to be softer than three phase and inverter type of generators by 0.4 mmAL and 0.55 mmAl HVL respectively. 3) Reproducibility Linearity of X-ray output Retroducibility of X-ray output met the regulation below CV 0.05 and linearity also met the regulation below 0.1 in 4 types of diagnostic X-ray generators. 4) The comparison of incident dose Three phase X-ray generator was 20% higher than two other X-ray generators in radiation dose to make same film density.

  • PDF

전산화단층촬영에서 촬영 목적 부위와 주변 결정장기에 대한 피폭선량 평가: 선량 권고량 중심으로 (Evaluation of Radiation Exposure Dose for Examination Purposes other than the Critical Organ from Computed Tomography: A base on the Dose Reference Level (DRL))

  • 이서영;김경리;하혜경;임인철;이재승;박형후;곽병준;유윤식
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.121-129
    • /
    • 2013
  • 최근 다중검출기 CT의 보편화 된 사용으로 환자의 피폭선량이 증가하고 있다. 따라서 광자극발광선량계를 이용해 촬영 목적 부위와 주변 결정장기에 대한 환자의 피폭선량을 측정하고 그에 따른 생물학적 효과를 예측하여 저감화 방안을 제시하고자 하였다. ICRP에서 권고한 표준안을 대상으로 만들어진 인체 모형 표준 팬텀에 교정상수를 부여받은 OSD 선량계를 측정하고자 하는 좌 우 수정체, 갑상선, 촬영의 중심점, 생식선에 부착하여 각 검사 부위별 노출 조건과 동일한 상태에서 환자의 피폭 선량을 모사하였다. OSL 선량계의 평균 교정상수는 $1.0058{\pm}0.0074$이었으며 검사 부위별 주변 결정장기의 등가선량은 좌 우측 수정체의 경우 직접 피폭이 약 50mGy로 최대였으며 간접 피폭되는 경우 0.24mGy, 원거리에서는 0.005mGy미만의 기준 준위 이하로 측정되었다. 갑상선의 경우 두부 검사에서 10.89mGy로 최대였으며 흉부에서 7.75mGy, 복부 및 요추부, 골반부에서는 기준 미만이었다. 생식선의 경우 골반검사에서 21.98mGy로 최대였으며 간접 피폭되는 검사에서 기준 준위 미만에서 6.92mGy까지 피폭되었다. CT 검사에서 DRL에 대한 저감화 방법은 국제기구에서 권고하고 있는 방사선 방어 원칙에 대한 정당한 해석과 제도적 뒷받침이 필요하다. 따라서 환자의 피폭을 최소화하기 위해서는 정당성을 충족하여야 하며 환자의 피폭선량에 미치는 영향들을 체계화하고 조직의 불필요한 피폭을 최소화 하여야 한다.

안양시에서 치과용 파노라마방사선사진의 참고 선량 수준 (Reference dose levels for dental panoramic radiography in Anyang City)

  • 김영희;이재서;윤숙자;강병철
    • Imaging Science in Dentistry
    • /
    • 제39권4호
    • /
    • pp.199-203
    • /
    • 2009
  • Purpose : To measure dose-width product (DWP) values used for dental panoramic radiography in Anyang city, Korea. Materials and Methods : Thirty-six panoramic dental radiographic sets (17 analogue panoramic sets and 19 digital panoramic sets) in 36 dental clinics in Anyang city were included in the study. Each patient's panoramic exposure parameters were simulated and the panoramic radiation doses were measured at the secondary collimator using a Mult-O-Meter (Unfors Instruments, Billdal, Sweden) at each dental clinic during 2006. The third quartile DWP was determined from 310 surface dose measurements on adult. Results : The third quartile DWP for adult panoramic radiograph was 106.7 mGy mm. For analogue and digital panoramic radiograph, 3/4 DWP were 116.8 mGy mm and 72 mGy mm respectively. The overall third quartile DWP of panoramic radiography was 106.7 mGy mm. Conclusion : The measured 3/4 DWPs were higher than the 3/4 DWP of 65 mGy mm recommended by NRPB. Dentists who are operating above the reference dose should lower their panoramic exposure doses below the recommended reference value by changing the exposure parameters and/or their panoramic equipments.

  • PDF

진단용 X선을 이용한 방사선검사에서 차폐체 모양과 부가필터 변화에 따른 난소의 선량 분석 (A Dose Analysis on the Ovary According to the Type of Shielding Material and the Change of Additional Filter in Radiography Using Diagnostic X-ray)

  • 최준호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.429-434
    • /
    • 2019
  • The gonads are directly affected by radiation exposure during radiography of the pelvis, abdomen, and spine. Exposure of the gonads to radiation can cause genetic mutations and can result in the occurrence of malignant tumors. In this study, we created three types of shielding material shapes for shielding of the ovaries, which are the gonads of female during radiography of the pelvis, and comparative evaluations using shadow shielding methods. The source surface distance(SSD) was 100 cm and the field size was 42 cm × 43 cm. The three types of shielding material shapes(type 1, 2 and 3) were assessed and the entrance surface dose in the ovaries were measured. The thickness of the shielding material was expanded from 0.3 mm to 2.4 mm and after five repetitions, radiation values were measured and mean values were calculated. The mean dose were 3.09 mGy for type 1, 3.54 mGy for type 2, and 3.19 mGy for type 3, indicating that the measurements were the lowest for type 1. When an additional filter of 0.2 Cu + 1 Al was used, the dose were 3.72 mGy for type 1, 5.43 mGy for type 2, and 4.05 mGy for type 3, indicating that the measurements were the lowest for type 1. The results show that, even if the shielding material is not thick, in other words, even with a thickness of 2.94 mGy for the SN 3(0.9 mm) of type 1, shielding can be achieved, with a patient dose lower than the diagnostic reference level(3.42 mGy). Additionally, among the three types of shielding material, the type 1 appeared to be the most appropriate shielding material. It is thought that the use of shielding material could reduce the risk factors for stochastic effects or critical effects of ionizing radiation during pelvic or lumbar radiography.

머신러닝 기반 고용량 I-131의 용량 예측 모델에 관한 연구 (A Study on Predictive Modeling of I-131 Radioactivity Based on Machine Learning)

  • 유연욱;이충운;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권2호
    • /
    • pp.131-139
    • /
    • 2023
  • High-dose I-131 used for the treatment of thyroid cancer causes localized exposure among radiology technologists handling it. There is a delay between the calibration date and when the dose of I-131 is administered to a patient. Therefore, it is necessary to directly measure the radioactivity of the administered dose using a dose calibrator. In this study, we attempted to apply machine learning modeling to measured external dose rates from shielded I-131 in order to predict their radioactivity. External dose rates were measured at 1 m, 0.3 m, and 0.1 m distances from a shielded container with the I-131, with a total of 868 sets of measurements taken. For the modeling process, we utilized the hold-out method to partition the data with a 7:3 ratio (609 for the training set:259 for the test set). For the machine learning algorithms, we chose linear regression, decision tree, random forest and XGBoost. To evaluate the models, we calculated root mean square error (RMSE), mean square error (MSE), and mean absolute error (MAE) to evaluate accuracy and R2 to evaluate explanatory power. Evaluation results are as follows. Linear regression (RMSE 268.15, MSE 71901.87, MAE 231.68, R2 0.92), decision tree (RMSE 108.89, MSE 11856.92, MAE 19.24, R2 0.99), random forest (RMSE 8.89, MSE 79.10, MAE 6.55, R2 0.99), XGBoost (RMSE 10.21, MSE 104.22, MAE 7.68, R2 0.99). The random forest model achieved the highest predictive ability. Improving the model's performance in the future is expected to contribute to lowering exposure among radiology technologists.

Verification of Secondary Electron Generated by Head Screw in Gamma Knife Using Monte Carlo N-Particle Simulation

  • Kim, Heesoo;Lee, Jeong-Woo
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.29-34
    • /
    • 2020
  • Purpose: The interaction of various substances inserted into the human body and radiation can confirm the radiation enhancement effect. A Leksell frame inserted into the human body for gamma knife treatment will cause not only pain and inconvenience to the patient, but also additional exposure to the patient's normal tissues. In this study, we attempt to confirm the additional exposure caused by the interaction of the Leksell frame and thermoplastic mask, and 60Co used for gamma knife treatment. Methods: A 60Co energy of 1.17, 1.33 MeV is applied using Monte Carlo simulation, and fixation screws and thermoplastic mask are fabricated using aluminum and titanium alloy, and Carbon compounds. Results: Results show a dose enhancement of up to 396.27% higher compared with that without a Leksell frame and up to 391.25% in thermoplastic mask. Conclusions: Hence, appropriate treatment methods and materials must be used to reduce additional exposure to normal tissues.

MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계 (An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode)

  • 오종갑
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.315-321
    • /
    • 2011
  • 본 연구는 검사 기법에 따른 영상의 질과 방사선 피폭의 정도를 제시하여 검사자가 받는 방사선 피폭을 저감시키는 데 목적이 있다. 관상동맥 전산화 단층 혈관조영(Coronary CTA, coronary computed tomography angiography) 검사자를 대상으로 SnapShot Pulse의 전향적 동조화 기법과 SnapShot Segment의 후향적 동조화 기법으로 coronary CTA 검사에서 검사자가 받는 단면 피폭선량(CTDIvol, volume computed tomography dose index), 총 피폭선량(dose-length product; DLP)을 각각 측정하였다. 또한, Coronary CTA 촬영조건을 동일하게 팬텀을 이용하여 CT감약계수, 노이즈 및 균일도, 공간분해능을 측정하였다. 연구 결과 두기법에서 CT감약계수, 노이즈 및 균일도, 공간분해능의 질적 수준이 비슷하게 나타났으며, CTDIvol, DLP는 SnapShot Segment의 후향적 동조화 기법에 비해 피폭선량이 약 37.5%, 40.3% 감소되었다. 임상에서 coronary CTA 검사 시 SnapShot Pulse의 전향적 동조화 기법을 적극 채택하여 검사자가 받는 방사선 피폭을 감소시키기 위한 노력이 절실히 요구된다.

몬테칼로 기법을 이용한 CBCT의 인체 내 장기의 흡수선량 평가 (Assesment of Absorbed Dose of Organs in Human Body by Cone Beam Computed Tomography using Monte Carlo Method)

  • 김종보;임인철;박은태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.215-221
    • /
    • 2018
  • Cone beam Computed Tomography(CBCT) is an increasing trend in clinical applications due to its ability to increase the accuracy of radiation therapy. However, this leaded to an increase in exposure dose. In this study, the simulation using Monte Carlo method is performed and the absorbed dose of CBCT is analyzed and standardized data is presented. First, after simulating the CBCT, the photon spectrum was analyzed to secure the reliability and the absorbed dose of the tissue in the human body was evaluated using the MIRD phantom. Compared with SRS-78, the photon spectrum of CBCT showed similar tendency, and the average absorbed dose of MIRD phantom was 8.12 ~ 25.88 mGy depending on the body site. This is about 1% of prescription dose, but dose management will be needed to minimize patient side effects and normal tissue damage.

경피적 추체 성형술 시행 시 환자와 시술자의 방사선 피폭선량에 관한 연구 (A Study on Radiation Exposure Dose of Patients and Operator during Percutaneous Vertebroplasty)

  • 이재헌;신성규;이효영
    • 한국방사선학회논문지
    • /
    • 제11권2호
    • /
    • pp.139-144
    • /
    • 2017
  • 경피적 추체 성형술은 최소 침습적 척추 수술로 골다공증성 압박골절, 골수종 그리고 암에 의한 척추 전이 등에 치료방법으로 많이 사용되어 왔다. 이러한 최소침습적 시술은 환자에게 작은 수술 흉터, 통증, 출혈, 짧은 회복시간등 여러가지 장점이 많으나, 환자와 시술자가 방사선의 위험으로부터 벗어날 수 없다. 이에 본 연구의 목적은 경피적 추체 성형술을 하는 동안 방사선 조사시간의 측정과 함께 시술자와 환자의 방사선 피폭선량을 측정해 보았다. 본원에 내원한 경피적 추체 성형술 시행 대상인 환자를 3명의 마취통증의학과 전문의가 동일한 방법으로 총 20명의 환자에게 경피적 추체 성형술을 실시하였다. 방사선 조사시간을 측정하고 전자선량측정계를 이용하여 총 6군데의 방사선 피폭량을 측정해 보았다. 환자는 직접 엑스선을 측정하였으며, 전 후면과 옆면 부위에 전자선량측정계를 위치하였고, 시술자는 환자로부터 산란되는 산란선을 측정하였으며, 납가운 바깥쪽에 위치한 갑상선, 왼쪽 가슴, 왼쪽 허벅지 그리고 납가운 안쪽에 위치한 왼쪽 가슴부위에 전자선량측정계를 위치하였다. 총 시술 시간은 $19.3{\pm}3.88min$이며, 방사선에 의한 노출 시간은 $3.6{\pm}0.71min$ 이었다. 환자의 피폭선량은 전후면 일 때 $121.4{\pm}48.15{\mu}Sv$ 였으며, 측면 일 때 피폭선량은 $614.7{\pm}177.14{\mu}Sv$ 이다. 시술자가 받은 피폭선량은 납가운 바깥쪽의 갑상선 부분이 $33.7{\pm}7.30{\mu}Sv$ 이고, 왼쪽 가슴 부위가 $49.2{\pm}15.09{\mu}Sv$ 이고, 왼쪽 허벅지 부위가 $12.8{\pm}3.80{\mu}Sv$ 이며, 납가운의 안쪽 가슴에 위치한 부위의 선량계는 $4.2{\pm}1.44Sv$ 이였다. 경피적 추체 성형술 시행 시 방사선의 위험으로부터 벗어나기 위해 C-arm 튜브에서 환자에게 엑스선이 도달하여 산란되는 거리를 최대한 멀게 유지하여야 하며, 방사선이 조사되는 시간을 줄이고, 납가운등 보호장구를 적절히 착용하여 방사선 피폭을 줄임으로써 시술자와 환자 모두 안전한 시술이 되도록 노력하여야 할 것이다.

I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구 (In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors)

  • 임광석;최학기;이기현
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.62-66
    • /
    • 2013
  • 우리나라의 갑상선 암이 증가함에 따라서 갑상선 전 절제술 후 고용량 방사성동위원소 치료를 받는 환자 또한 증가하였다. 하지만 치료를 위해서 사용되는 I-131의 경우 반감기가 8.01일 이며 감마선과 베타선을 내는 특징이 있어 타인에게 줄 수 있는 외부 피폭의 영향을 막기 위해 일정기간 동안 환자가 격리병실에 입원하여 치료를 받게 된다. 이틀 내지 사흘 동안의 격리치료를 한 후 퇴원 전 환자의 몸에서 나오는 방사선량이 법적 기준(70 uSv/h)에 만족하는지 확인한 후 퇴원을 하게 된다. 그리고 다음 환자가 입원 시까지 병실 곳곳의 오염도를 확인 한 후 필요 시에는 제염작업을 수행하게 된다. 우리는 이러한 일련의 과정들 상에서 의료진들이 피폭의 영향을 받게 되는 주 요인으로는 환자의 퇴원선량 확인 및 치료병실의 오염도확인과 제염작업시의 피폭으로 예상된다. 본 연구는 환자의 여러 가지 요소들을(환자의 신기능, 연령, 성별, 초기 투여용량, Tg, Tg-ab)정하고 그 인자들을 통해 환자의 퇴원선량 및 치료병실 오염도에 어떠한 영향을 미치는지 알아보고자 한다. 본원에서 2011년 8월 1일부터 2012년 5월 29일까지 입원하여 고용량방사성 요오드 치료를 받은 환자 151명을 대상으로 실시하였다. 환자의 glomerular filtration rate (GFR) 값이 높을수록 퇴원선량이 낮은 상관관계를 보였다(P<0.001).초기 투여용량의 경우 5.5 GBq (150 mCi) 미만과 5.5 GBq (150 mCi) 이상을 투여 받은 환자군 두 그룹 사이에 평균 퇴원선량을 비교 분석한 결과 5.5 GBq (150 mCi) 미만을 투여 받은 환자 군에서 퇴원선량이 유의하게 낮음을 알 수 있었다($23.95{\pm}10.44uSv/h$, $28.65{\pm}11.79uSv/h$). 연령,성별, Tg, Tg-ab는 환자의 퇴원 선량과 유의한 관계를 보이지 않았다(p>0.05). 그리고 치료병실 오염도는 환자의 퇴원선량과 환자의 신기능과는 유의한 관계를 보이지 않았다 (p>0.05). 병실 오염도의 경우는 입원기간 동안 환자의 생활습관이나 기타 다른 다양한 요인에 의해 영향을 받을 것으로 사료된다. 비록 성별의 집단 간에 따라서 오차가 있다고 여겨지지만 추후 더 많은 환자들을 비교 분석 한다면 도움이 될 것이라고 판단된다. 또한 퇴원선량과 병실의 오염도에 영향을 줄 수 있는 기타 다른 요인들에 대해서도 지속적으로 연구한다면 환자 본인의 피폭뿐만 아니라 가족과 그주변인 의료진들에게도 조금이나마 피폭의 영향을 감소 시킬 수 있을 것이라고 사료된다.

  • PDF