• 제목/요약/키워드: patient exposure

검색결과 895건 처리시간 0.028초

전남 지방에서 치근단방사선사진의 참고 선량 수준 (Reference dose levels for dental periapical radiography in Chonnam Province)

  • 한미라;강병철;이재서;윤숙자;김영희
    • Imaging Science in Dentistry
    • /
    • 제39권4호
    • /
    • pp.195-198
    • /
    • 2009
  • Purpose : To establish reference doses of periapical radiography in Chonnam Province, Korea. Materials and Methods : The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. Results : The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. Conclusion : The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  • PDF

복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향 (Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography)

  • 김유현;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

CT 촬영 조건에 따른 PET 영상의 변화 (Change of PET Image According to CT Exposure Conditions)

  • 박재윤;김정훈;이용기
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.473-479
    • /
    • 2019
  • 다양한 촬영 조건의 CT 감쇠 지도가 PET 영상에 영향을 미치는지 알아보기 위하여 다양한 kVp와 mA조건에서 Uniformity phantom 영상의 신호 강도(SI; Signal Intensity)와 표준 섭취율 계수(SUV; Standardized Uptake Value)를 측정하고, CTDI (Computed Tomography Dose Index)를 통해 각 조건에 따른 피폭선량을 측정하였다. 또한 동일한 조건에서 Resolution phantom의 반치폭(FWHM; Full Width at Half Maximum)을 측정하여 CT의 kVp와 mA에 따른 PET 영상의 화질 변화에 대하여 정량적으로 알아보고자 하였다. 연구 결과, CT의 촬영 조건은 PET 영상에는 영향을 주지 않는 것으로 나타났으나, CT의 촬영 조건이 감소하게 되면 방사선 피폭이 감소하게 되지만 영상에 영향을 미치게 되므로 향후 진단이 가능한 CT 화질을 유지하면서 방사선 피폭을 최소화할 수 있는 양전자 방출 단층 촬영(PET/CT; Positron Emission Tomography / Computed Tomography)의 촬영 조건에 대한 연구가 지속적으로 되어야 할 것이다.

Patient care와 cost benefit를 고려(考慮)한 흉부(胸部) X선촬영(線撮影) (A Study on Chest Radiography Taken Patient Care and Cost Benefit into Consideration)

  • 임태랑
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제13권2호
    • /
    • pp.53-65
    • /
    • 1990
  • Exposure factors in the chest radiographic examination vary with hospital. They include low voltage radiation to high voltage hard radiation quality, which are in wide use. In the present report, exposure factors generally employed are reviewed, and the chest radiograhic techniques performed in our hospital are explained. In addition, the attitude of radiological technologists toward patients and so forth are also discussed.

  • PDF

Videodensitometry법을 이용한 X선사진의 흑화도와 대조도에 관한 연구 (THE VIDEODENSITOMETRIC ANALYSIS OF THE RADIOGRAPHIC DENSITY AND CONTRAST)

  • 유영선;이상래
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.293-303
    • /
    • 1992
  • Generally the patient's absorb dose and readability of radiograms are affected by the exposure time and kVp of which are related with the radiographic density and contrast The investigator carried studies to know the adequate level of exposure time and kVp to obtain the better readability of radiograms. In these studies dried human mandible with selfcuring acrylic resins attached with aluminum step wedge was used and readability of radiograms were compared with each other by videodensitometry among various combination sets of the exposure time, such as 5, 6, 8, 12, 15, 19, 24, 30, 38, 48 and 60, and varing level of kVp, such as 60, 65, 70, 80 and 90 respectively. The obtained results were as follows: 1. As exposure time and kVp were increased, radiographic density of radiograms was increased. 2. The subject contrast was increased where aluminum step wedge was thin and reduced in the reversed condition. At the thin aluminum step wedge, subject contrast was increased at the condition of lower kilovoltage than that of higher kilovoltage. 3. In the case of non-constant radiographic density, the radiographic contrast was reduced with the increment kilovoltage. The radiographic contrast was increased in the lower kilovoltage with the longer exposure time and the higher kilovoltage with the shorter exposure time. 4. At the condition of short exposure time, better readability of each reading item was obtained with the increment of the kilovoltage but at the opposite condition increasing exposure time worsened readability of radiograms. Since X-ray machine in the current dental clinics is fixed between the range of 60-70kVp and 10mA, good radiograms can be obtained by varied exposure time. But according to the conclusion of these studies, better radiograms can be obtained by using filtered high kVp and then the absorb dose to patient and exposure time can be reduced.

  • PDF

Radiation safety for pain physicians: principles and recommendations

  • Park, Sewon;Kim, Minjung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제35권2호
    • /
    • pp.129-139
    • /
    • 2022
  • C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician's but also the patient's radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician's and patient's radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • 나길주;백수웅;양현훈;박계춘
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

전립선암의 근접치료 시 이식환자에 근접한 사람의 선량평가 (Dose Evaluation of the Man Adjacent to an Implanted Patient During the Prostate Cancer Brachytherapy)

  • 박은태;김정훈
    • 한국방사선학회논문지
    • /
    • 제10권1호
    • /
    • pp.39-44
    • /
    • 2016
  • 본 연구는 전립선암의 치료방법 중 근접치료 시 환자 주변의 공간에 대한 선량을 평가한 것으로 환자, 시술자 그리고 보호자에 대한 선량을 예측함으로서 피폭을 최소한으로 예방하고자 수행하였다. 실험방법은 몬테칼로법을 기반으로 한 MCNPX를 사용하여 가상의 공간에서 모의피폭체를 만들어 실험하였으며, 선원은 $^{192}Ir$, $^{125}I$, $^{103}Pd$를 seed 형태로 이식하였다. 환자를 중심으로 전방 30, 50, 100, 200 cm 거리에 관심영역을 설정하여 공간 선량을 평가하였다. 그 결과 거리에 관계없이 $^{192}Ir$에서 가장 높은 선량을 나타내었다.

환자 이송원의 피폭선량 측정 (A Measurement of Exposure Dose for Patient Transporter)

  • 송채림;이왕희;안성민
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.433-438
    • /
    • 2019
  • 의료기관에서는 환자의 진단 및 치료를 위해 방사선발생장치 및 방사성동위원소를 사용하고 있다. 환자이송원은 환자이송을 위해 불가피하게 방사선 관리구역에 출입하거나, 동위원소가 투여된 환자를 근거리에서 이송하는 등 일반인과 비교했을 때, 방사선에 노출될 확률이 높은 환경에서 업무를 수행한다. 따라서 환자이송원의 피폭 정도를 알아보고자 연구를 진행했다. 인천 A 종합병원에서 근무하고 있는 12명의 환자이송원을 대상으로 2019년 4월 1일부터 4월 30일까지 한 달 동안 선량계를 가슴에 패용하고, 누적된 선량을 측정했다. 사용된 선량계는 광자극발광선량계(OSLD), 선량판독은 OSLD Microstar Reading System을 사용했다. 한 달 동안 누적선량 측정 결과 심부선량은 평균 0.13 mSv, 표층선량은 평균 0.13 mSv로 측정되었고, 한 달 동안 누적된 선량에 12를 곱해 일 년 동안 업무를 수행할 시 받게 될 누적선량 예상치를 추정한 결과 심부선량은 평균 1.52 mSv, 표층선량은 평균 1.51 mSv로 나타났다. 환자이송원의 수시출입자 분류를 통해 피폭선량을 측정, 관리 하고, 교육훈련을 통해 방사선에 대한 방호지식을 높이며 건강진단을 통해 방사선장해 발생을 방지하기 위한 노력이 필요하다.

흉부촬영시 피폭선량과 화질에 관한 조사연구 (The Study on the Image Quality and Patient Exposure Dose of Chest Radiography in Korea)

  • 이선숙;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제18권2호
    • /
    • pp.49-59
    • /
    • 1995
  • Recently, general radiography became to variety because of the continuous development of Inverter type generator and ortho chromatic system. Therefore, we must re-evaluate about patient exposure dose and image quality. I studied about chest radiography which has frequency among general radiography being used during FEB. to AUG., 1994 over 151 medical facilities from medical facilities that are located in Seoul area. The result obtained were as follows ; 1) The rectification method of the generator were employing mainly single phase full wave in 82.8 %, three phase full wave in 11.26 % and Inverter type in 4.64 % and condenser type is 1.32 %. 2) Exposure kV was used below 80 kV in most medical facilities and 21.8 % of the medical facilities was using high tube voltage higher than 120 kV. 3) The exposure time was used below the 0.05 sec in 28.4 %, in 29.8 % of the medical facilities used above 0.1 sec. 4) The usage frequency of the added filter is 15.3 %, and among them compound filter was used only 4 %. 5) Rare earth screen was used in 37.7 %. 6) The average skin entrance dose was 0.25 mSv, the range of dose is $0.05{\sim}0.79\;mSv$ in each medical facilities. 7) The average density of the lung field is 1.76, 0.49 in lung side, 0.30 in mediastinum and 0.37 in heart shadow. Therefore it is required to improve all of these for increasing image quality and reducing patient exposure dose as soon as possible.

  • PDF