컴퓨터 단층촬영 방사선 노출 관리 시스템 소프트웨어 설계 (System Software Design of Computerized Tomography Radiation Dose Management)

  • 양유미;조상욱;이길흥
    • 디지털산업정보학회논문지
    • /
    • 제10권3호
    • /
    • pp.41-48
    • /
    • 2014
  • This paper provides the design of system software for the management of radiation dose that is generated by using computerized tomography(CT). Recently, the radiation leakage incident of Japanese nuclear power plant was in the news internationally and there is a growing interest not only in nuclear power plant but in medical radiation exposure. In spite of the fact that currently safety management of radiation is under control only the workers of the radiation involved, now the exposure management of patients have been required. As surgery and inspections using the radiation have increased, this medical radiation exposure is increasing too. But it is a real situation that medical institutions don't know the level of radiation exposure applied to the patient. Therefore, a system for managing the radiation exposure of a patient from the medical institution is required. This paper proposes a design of a software program that manages the radiation exposure of CT which is a typical imaging tool to use the radiation in the medical institution. By check the amount of radiation dose and set the limit of dose, we would be of help to optimize the medical exposure of the patient.

X선 촬영시 피폭선량 및 실내공간선량에 관한 연구 (A Study on the Exposure and Free Space Scattered Dose in Radiography)

  • 안봉선;이규은;선종률
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권2호
    • /
    • pp.26-30
    • /
    • 1998
  • We tried to study in order to furnish the data for medical exposure dose and scattered ray in radiography. As the tables(from 1 to 3) show, we can presume, by means of a concrete numerical value, the amount of results affected by patient radiation exposure dose and somatic effect in radiography. However, there are many difficulties in the difference of exposure factor in each hospital, the accuracy of measuring by tracebility, shortage of exposure dose data especially in the area of children, and portable radiography, etc. In the radiation examination, it is considered if the gained benefit to the patient due to radiation is more than the risk of radiation, then the medical exposure is thought to be justified. Therefore, the radiotechnologists should continually make an effort to develop and study new techniques so as to reduce patient exposure dose.

  • PDF

흉부질환의 화질과 피폭을 고려한 촬영조건의 연구 (A Study on the Chest Radiography with Diseases in Consideration of Image Qualify and Patient Exposure)

  • 이만구;임태랑;석전유치
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.56-62
    • /
    • 1997
  • To evaluated the image quality and the patient exposure for the chest radiography, its fundamental imaging properties were investigated. The basic imaging properties were evaluated by measuring characteristic curves, relative speeds, average gradient, and patient exposure dose. The image qualities were evaluated by using a rotating meter. It was found that the film gradient of SRO750/SRH system was 3.13 and that of SRO750/HR-C30 was 1.77. The ratio of SRO1000/TMH to FS/RP-1 was 1 to 18.2. It was possible to visualize the static image when the exposure time was less than 2.5 msec in patient that had respiratory excessive motion, heart beat and natural physical motion, and less than 8.5 msec in normal. The ratio of medical exposure dose compared with our method was 1 to 25 in the routine chest radiography and maximum was 1 to 70. In estimation of the image quality in same cases, we found that the image of SRO1000/SRH and TMH of super sensitive systems was the same results. We found that these super sensitive screen-film systems were available for the chest radiography considering the relationship between the image quality and patient exposure.

  • PDF

병원의료진의 언론노출과 진료실적간의 관계 - 일개 대학병원 사례를 기준으로 - (The Relationship between the Media Exposure of Hospital Physicians and Patient Volume - a University Hospital Case -)

  • 김성철;김태경;김태현;박소희;이상규
    • 한국병원경영학회지
    • /
    • 제21권1호
    • /
    • pp.51-61
    • /
    • 2016
  • This study attempted to investigate how mass media marketing of a hospital influences patient volume. Additionally, the association of patient volume with exposure time and the type of mass media was examined. Data from a university hospital in Bundang (from January 2014 to November 2014) were used. Degree of physicians' mass media marketing was measured by the number of media exposure. Linear mixed model for repeated measures data was run to identify the associations between the number of media exposure and patient volume. First, the number of hospital physician's mass media exposure and new patients and the first visit patients were positively associated. Second, broadcasting media which has relatively significant in patient volume is TV programs such as cultural programs and news. Third, hospital physicians with higher ranks who were exposed to press media receive more patient appointment. Also, nonsurgical hospital physicians who were exposed to press media receive more patients. Fourth, medical treatment activities for hospital staff who hold the rank of Professor in case of making an appearance at press media have relatively increased. Hospital physician's media exposure, particularly TV programs, was significantly related to patient volume for outpatients.

Whole Spine Scanography의 검사방향에 따른 환자 선량 평가 (Patient Radiation Exposure Dose Evaluation of Whole Spine Scanography Due to Exposure Direction)

  • 김정수;서덕남;권순무;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권1호
    • /
    • pp.1-6
    • /
    • 2015
  • Whole spine scanography(WSS)는 전신에 X선을 조사하는 검사로 치료기간 동안 빈번한 X선 조사가 이루어지는 검사이다. 일반촬영 분야에서는 많은 X선이 전신에 조사되는 검사이다. 따라서 논문에서는 Auto image pasta기법의 디지털 WSS 검사에서 환자의 검사방향에 따른 유효선량과 장기선량을 전산모사를 통하여 평가하였고, 영상에서 척추의 확대도와 각도의 변화를 평가하였다. 전후면 자세에서의 평균 유효선량은 0.069 mSv였고, 후전면 자세에서 평균 유효선량은 0.0361 mSv로 약 2배의 차이를 보였다. 전후면 자세에서 남성의 평균 유효선량은 0.089 mSv, 여성에 대한 평균 유효선량은 0.431 mSv로 나타났고, 후전면 자세에서 남성의 평균 유효선량은 0.050 mSv, 여성에서는 0.026 mSv로 나타났다. 확대율에서는 후전면 자세에서 전후면 자세에 비해 5%정도 확대 되었으나 각도에는 큰 변화를 보이지 않았다. 따라서 임상 환경에서 동일한 검사조건에서 환자의 자세를 변화시키는 것만으로도 환자의 피폭선량을 감소시킬 수 있음을 확인하였다. 특히 WSS와 같이 치료기간 동안 반복되는 검사에서 환자의 피폭선량 최적화를 위하여 검사 프로토콜의 재정립이 필요함을 확인하였다.

갑상선 암의 방사성요오드 치료 시 의료진은 방사선 피폭으로부터 안전한가? (Are Medical Personnel Safe from Radiation Exposure from Patient Receiving Radioiodine Ablation Therapy?)

  • 김창근;김대응
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권4호
    • /
    • pp.259-279
    • /
    • 2009
  • Radioiodine ablation therapy has been considered to be a standard treatment for patient with differentiated thyroid cancer after total thyroidectomy. Patients may need to be hospitalized to reduce radiation exposure of other people and relatives from radioactive patients receiving radioiodine therapy. Medical staffs, nursing staffs and technologists sometimes hesitate to contact patients in radioiodine therapy ward. The purpose of this paper is to introduce radiation dosimetry, estimate radiation dose from patients and emphasize the safety of radiation exposure from patients treated with high dose radioiodine in therapy ward. The major component of radiation dose from patient is external exposure. However external radiation dose from these patients treated with typical therapeutic dose of 4 to 8 GBq have a very low risk of cancer induction compared with other various risks occurring in daily life. The typical annual radiation dose without shielding received by patient is estimated to be 5 to 10 mSv, which is comparable with 100 to 200 times effective dose received by chest PA examination. Therefore, when we should keep in mind the general principle of radiation protection, the risks of radiation exposure from patients are low and the medical personnel are considered to be safe from radiation exposure.

심장 전기생리학 검사 시 조건 변화에 따른 환자 피폭 선량 평가 (Evaluation of Patient Exposure Dose during Cardiac Electrophysiology Study under Various Conditions)

  • 고성빈;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.501-508
    • /
    • 2023
  • This study used a adult absorption dose phantom (CIRS model 701-G, USA) made of human equivalent material and the vascular imaging equipment Allura Xper FD 20 (Philips, Netherlands). Optically stimulated luminescent dosimeters (OSLD) were inserted into the anatomical positions corresponding to each organ, and the exposure dose was measured. Dose area product (DAP) and air kerma (AK) measured by the dose meter in the equipment were compared. Continuous imaging was performed at two angles for a total of 20 minutes, with a frame per seconds of 3.75 and 7.5 fps and an FOV of 42 cm, 37 cm, and 31 cm, respectively, under the conditions of fluoflavor I, II, and III, each selected for 5 repetitions. This study was found that selecting a lower fps was the most effective way to reduce patient exposure dose, and adjusting the fluoflavor was a good alternative method for reducing patient exposure dose at high fps. Therefore the method of condition change with the greatest dose reduction effect is to set the minimum FPS and can reduce patient exposure dose according to geometric conditions and fluoflavor characteristics.

컴퓨터 단층촬영(CT) 방사선 노출 관리 시스템 소프트웨어 설계 (System Software Design of Computed Tomography Radiation Dose Management)

  • 양유미;이길흥;조상욱
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.489-492
    • /
    • 2014
  • 본 논문에서는 컴퓨터 단층활영(CT)을 통해 발생되는 방사선 노출량의 관리를 위한 시스템의 소프트웨어 설계를 제안한다. 방사선 피폭량은 환자의 각 신체 부위별로 민감성의 차이에 따라 다르기 때문에 방사선의 노출량을 관리할 수 있게 되면 결과적으로 환자의 방사선 피폭량을 추정할 수 있다. 최근 일본 원전의 방사선 누출 사건이 국제적으로 뉴스가 되었고 원전 뿐 만아니라 의료용 방사선 피폭까지 폭넓게 관심이 커지고 있다. 현재 방사선 안전관리는 방사선 관계 종사자에 대해서만 관리되고 있지만, 이제는 환자에 대한 피폭 관리까지 요구되고 있다. 우리나라에서 방사선을 이용한 검사와 시술이 증가하여 이에 따른 의료 피폭이 증가하였으나 의료 기관에서는 환자에게 가해지는 방사선 피폭 수치를 알지 못하는 실정이다. 따라서 의료 기관에서 환자의 방사선 피폭을 관리할 수 있는 시스템이 필요하다. 본 논문에서는 의료 기관에서 방사선을 이용하는 대표적인 촬영 도구인 CT의 방사선 노출량을 관리할 수 있는 소프트웨어 설계를 제시한다. 방사선의 노출량을 확인하고 선량의 한도를 설정함으로써 환자의 의료 피폭량을 최적화 하는데 도움이 되고자 한다.

  • PDF

진단참고수준 기반 두부 방사선검사의 최적 목표노출지수 설정에 관한 연구 (A Study on Establishment of the Optimal Target Exposure Index for Skull Radiography Based on Diagnostic Reference Level)

  • 박혜민;윤용수;김은혜;정회원;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.599-605
    • /
    • 2021
  • The International Electrotechnical Commission (IEC) 62494-1 has defined the exposure index (EI) that have a proportional relationship with the dose incident on the image receptor, and target exposure index (EIT), deviation index (DI). In this study, an appropriate EIT for skull radiography was established through the diagnostic reference level (DRL) and changes in DI were confirmed. Entrance surface dose (ESD) and EI were obtained using the computed radiography system displayed the EI as per IEC on console and skull phantom by experiment based on the national average exposure conditions announced in 2012 and 2019. And appropriate EIT was established by applying the DRL in 2012 and 2019. As a results, the EIT is changed according to the change in the DRL, and the exposure condition that becomes the ideal DI according to the change in the EIT also has a difference of about 1.41 times. DRL is recommended to optimize the patient dose, however it is difficult to measure in real time at medical institutions whereas EI and DI are displayed on the console at the same time as exposure. When the EIT is set based on the DRL and the DI is closed to an ideal value, it is useful as a patient dose management tool. Therefore, when the EIT is periodically managed along with the revision of the DRLs, the patient dose can be optimized through the EI, EIT and DI.

Blood and Body Fluid Exposure Related Knowledge, Attitude and Practices of Hospital Based Health Care Providers in United Arab Emirates

  • Zaidi, Moazzam Ali;Grifftths, Robin;Beshyah, Salem A.;Myers, Julie;Zaidi, Mukarram A.
    • Safety and Health at Work
    • /
    • 제3권3호
    • /
    • pp.209-215
    • /
    • 2012
  • Objectives: Knowledge, attitudes, and practices of healthcare providers related to occupational exposure to bloodborne pathogens were assessed in a tertiary-care hospital in Middle East. Methods: A cross-sectional study was undertaken using a self-administered questionnaire based on 3 paired (infectivity known vs. not known-suspected) case studies. Only 17 out of 230 respondents had an exposure in the 12 months prior to the survey and of these, only 2 had complied fully with the hospital's exposure reporting policy. Results: In the paired case studies, the theoretical responses of participating health professionals showed a greater preference for initiating self-directed treatment with antivirals or immunisation rather than complying with the hospital protocol, when the patient was known to be infected. The differences in practice when exposed to a patient with suspected blood pathogens compared to patient known to be infected was statistically significant (p < 0.001) in all 3 paired cases. Failure to test an infected patient's blood meant that an adequate risk assessment and appropriate secondary prevention could not be performed, and reflected the unwillingness to report the occupational exposure. Conclusion: Therefore, the study demonstrated that healthcare providers opted to treat themselves when exposed to patient with infectious disease, rather than comply with the hospital reporting and assessment protocol.