• Title/Summary/Keyword: patient dose

Search Result 1,806, Processing Time 0.033 seconds

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF

HVL Measurement of the Miniature X-Ray Tube Using Diode Detector (다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정)

  • Kim, Ju-Hye;An, So-Hyeon;Oh, Yoon-Jin;Ji, Yoon-Seo;Huh, Jang-Yong;Kang, Chang-Mu;Suh, Hyunsuk;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • The X ray has been widely used in both diagnosis and treatment. Recently, a miniature X ray tube has been developed for radiotherapy. The miniature X ray tube is directly inserted into the body irradiated, so that X rays can be guided to a target at various incident angles according to collimator geometry and, thus, minimize patient dose. If such features of the miniature X ray tube can be applied to development of X ray imaging as well as radiation treatment, it is expected to open a new chapter in the field of diagnostic X ray. However, the miniature X ray tube requires an added filter and a collimator for diagnostic purpose because it was designed for radiotherapy. Therefore, a collimator and an added filter were manufactured for the miniature X ray tube, and mounted on. In this study, we evaluated beam characteristics of the miniature X ray tube for diagnostic X ray system and accuracy of measuring the HVL. We used the Si PIN Photodiode type Piranha detector (Piranha, RTI, Sweden) and estimated the HVL of the miniature X ray tube with added filter and without added filter. Through an another measurement using Al filter, we evaluated the accuracy of the HVL obtained from a direct measurement using the automatic HVL calculation function provided by the Piranha detector. As a result, the HVL of the miniature X ray tube was increased around 1.9 times with the added filter mounted on. So we demonstrated that the HVL was suitable for diagnostic X ray system. In the case that the added filter was not mounted on, the HVL obtained from use of the automatic HVL calculation function provided by Piranha detector was 50% higher than the HVL estimated using Al filter. Therefore, the HVL automatic measurement from the Piranha detector cannot be used for the HVL calculation. However, when the added filter was mounted on, the HVL automatic measurement value using the Piranha detector was approximately 15% lower than the estimated value using Al filter. It implies that the HVL automatic measurement can be used to estimate the HVL of the miniature X ray tube with the added filter mounted on without a more complicated measurement method using Al filter. It is expected that the automatic HVL measurement provided by the Piranha detector enables to make kV-X ray characterization easier.

A Study of Various Filter Setups with FBP Reconstruction for Digital Breast Tomosynthesis (디지털 유방단층영상합성법의 FBP 알고리즘 적용을 위한 다양한 필터 조합에 대한 연구)

  • Lee, Haeng-Hwa;Kim, Ye-Seul;Lee, Youngjin;Choi, Sunghoon;Lee, Seungwan;Park, Hye-Suk;Kim, Hee-Joung;Choi, Jae-Gu;Choi, Young-Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.271-280
    • /
    • 2014
  • Recently, digital breast tomosynthesis (DBT) has been investigated to overcome the limitation of conventional mammography for overlapping anatomical structures and high patient dose with cone-beam computed tomography (CBCT). However incomplete sampling due to limited angle leads to interference on the neighboring slices. Many studies have investigated to reduce artifacts such as interference. Moreover, appropriate filters for tomosynthesis have been researched to solve artifacts resulted from incomplete sampling. The primary purpose of this study is finding appropriate filter scheme with FBP reconstruction for DBT system to reduce artifacts. In this study, we investigated characteristics of various filter schemes with simulation and prototype digital breast tomosynthesis under same acquisition parameters and conditions. We evaluated artifacts and noise with profiles and COV (coefficinet of variation) to study characteristic of filter. As a result, the noise with parameter 0.25 of Spectral filter reduced by 10% in comparison to that with only Ramp-lak filter. Because unbalance of information reduced with decreasing B of Slice thickness filter, artifacts caused by incomplete sampling reduced. In conclusion, we confirmed basic characteristics of filter operations and improvement of image quality by appropriate filter scheme. The results of this study can be utilized as base in research and development of DBT system by providing information that is about noise and artifacts depend on various filter schemes.

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.

Effects of Postoperative Radiotherapy on Distribution of Bone Metastases in Breast Cancer (유방암환자에서 수술 후 방사선치료가 골전이 분포에 미치는 영향)

  • Kim, Bo-Kyoung;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.211-215
    • /
    • 2001
  • Purpose : This study was done to evaluate the efficacy of low-dose radiation in reduction of thoracic vertebral metastases in patients with breast cancer. Materials and Methods : 109 patients who were treated for bone metastasis from breast cancer from June, 1988 to June, 1998 in the Department of Therapeutic Radiology, Seoul National University were included. Of the 109 patients, 40 patients had been previously treated by postoperative radiotherapy and 69 had not. Postoperative radiotherapy had been given using Co-60 teletherapy device in 30 patients or 6 MV linear accelerator in 10. Thoracic spines from 1 to 10 were usually irradiated except in 1 patient and cervical vertebrae 6 and/or 7 were partially included in ,: patients. A total of 50.4 Gy was given with 1.8 Gy fraction. Metastatic bone diseases were scored in 11 regions, i. e., skull, conical spine, thoracic spine from 1 to 4, from 5 to 8, 9 and 10, 11 and 12, lumbar spine, pelvis, femur, ribs and others. Results : In no postoperative parasternal irradiation group, lumbar vertebrae were the most common metastatic sites $(55.1\%)$ followed by pelvis $(44.9\%)$, ribs $(40.6\%)$, thoracic vertebrae 11 and 12 $(37.7\%)$, thoracic vertebrae between 5 and 8 $(36.2\%)$, thoracic vertebrae 9 and 10 $(34.8\%)$, and thoracic vertebrae between 1 and 4 $(26.1\%)$. In postoperative parasternal irradiation group, lumbar vertebrae and pelvis were also the most common sites of metastases ($55.0\%$, respectively) followed by ribs $(37.5\%)$, and thoracic vertebrae 11 and 12 $(32.5\%)$. But significant less metastases were seen at thoracic vertebrae from 1 to 10. Conclusion : We can find that the were significantly less bony metastases at thoracic vertebrae which had been previously irradiated postoperatively.

  • PDF

Chronic Hereditary Tyrosinemia Type I with Novel Mutation in FAH Gene (FAH gene novel mutation을 가진 만성형 Hereditary tyrosinemia 1형)

  • Yang, Sungmin;Choi, Hyo Won;Kang, Yun Koo;Lee, Jin-Sung;Namgoong, Mee Kyung
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.20 no.2
    • /
    • pp.55-62
    • /
    • 2020
  • A 22-month-old girl who had taken iron supplements due to iron deficiency anemia, presented bloody mucoid stool for one month. She had a bruise at the right periorbital area due to minor trauma and hepatosplenomegaly. Laboratory studies showed anemia, thrombocytopenia, elevated alkaline phosphatase (ALP), hypophosphatemia, decreased haptoglobin, hypocomplementemia, negative direct/indirect Coomb's test, normal vitamin D3 level and high PTHi. Wrist x-ray showed no signs of rickets. The abdominal ultrasound showed only accessory spleen. Tandem mass spectrometry was normal. During follow up, bloody stool regressed after seven days of withdrawal of iron supplement and cow milk, and the total CO2 level had been within 15-20 mEq/L with normal anion gap. NGS (next generation sequencing) panel test for evaluation of renal tubular acidosis showed negative results. After low dose steroid and vitamin D supplements under the impression of hypocomplementemic vasculitis, thrombocytopenia, C3/C4, decreased haptoglobin, and elevated ALP level became normal. At 57 months of age, laboratory findings showed elevated liver enzyme, ALP and gamma-glutamyl transferase again. And liver cirrhosis with splenomegaly and diffuse renal disease were reported with abdomen CT scan. Liver biopsy reported macro- and micronodular cirrhosis. Urine organic acid profile showed elevated succinylacetone level. Whole exome sequencing revealed novel compound heterozygous mutations (NM_00137.2:c.107T>C, NM_00137, 2:c.614T>C) in FAH gene and confirmed by Sanger sequencing. Consequently, the patient was diagnosed as chronic hereditary tyrosinemia type I. She started low phenylalanine/tyrosine diet and nitisinone treatment. Our case had presented symptoms very slowly, which is the first case of chronic tyrosinemia type I in South Korea.

F-18 FDG PET Scan findings in Patients with Pulmonary Involvement in the Hypereosinophilic Syndrome (원발성 과호산구증가 증후군 환자들 중 폐침범을 보이는 환자군의 F-18 FDG PET 소견)

  • Lee, Jae-Hoon;Kim, Tae-Hoon;Yun, Mi-Jin;Hur, Jin;Kim, Tae-Sung;Kim, Sang-Jin;Kim, Hyung-Joong;Pai, Moon-Sun;Ryu, Young-Hoon;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.239-245
    • /
    • 2005
  • Purpose: Hypereosinophilic syndrome (HES) is an infiltrative disease of eosinophils affecting multiple organs including the iung. F-18 2-fluoro-2-deoxyglucose (F-18 FDG) may accumulate at sites of inflammation or injection, making interpretation of whole body PET scan difficult in patients with cancer. This study was to evaluate the PET findings of HES with lung involvement and to find out differential PET features between lung malignancy and HES with lung involvement. Material and Methods: F-18 FDG PET and low dose chest CT scan was performed for screening of lung cancer. light patients who showed ground-glass attenuation (GGA) and consolidation on chest CT scan with peripheral blood eosinophilia werr included in this study. The patients with history of parasite infection, allergy and collagen vascular disease were excluded. CT features and FDG PET findings were meticulously evaluated for the distribution of GGA and consolidation and nodules on CT scan and mean and maximal SUV of abnormalities depicted on F-18 FDG PET scan. In eight patients, follow-up chest CT scan and FDG PET scan were done one or two weeks after initial study. Results: F-18 FDG PET scan identified metabolically active lesions in seven out of eight patients. Maximal SUV was ranged from 2.8 to 10.6 and mean SUV was ranged from 2.2 to 7.2. Remaining one patient had maximal SUV of 1.3. On follow-up FDG PET scan taken on from one to four weeks later showed decreased degree of initially noted FDG uptakes or migration of previously noted abnormal FDG uptakes. Conclusions: Lung involvement in the HES might be identified as abnormal uptake foci on FDG PET scan mimicking lung cancer. Follow-up FDG PET and CT scan for the identification of migration or resolution of abnormalities and decrement of SUV would be of help for the differentiation between lung cancer and HES with lung involvement.

Clinical Usefulness of Implanted Fiducial Markers for Hypofractionated Radiotherapy of Prostate Cancer (전립선암의 소분할 방사선치료 시에 위치표지자 삽입의 유용성)

  • Choi, Young-Min;Ahn, Sung-Hwan;Lee, Hyung-Sik;Hur, Won-Joo;Yoon, Jin-Han;Kim, Tae-Hyo;Kim, Soo-Dong;Yun, Seong-Guk
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.91-98
    • /
    • 2011
  • Purpose: To assess the usefulness of implanted fiducial markers in the setup of hypofractionated radiotherapy for prostate cancer patients by comparing a fiducial marker matched setup with a pelvic bone match. Materials and Methods: Four prostate cancer patients treated with definitive hypofractionated radiotherapy between September 2009 and August 2010 were enrolled in this study. Three gold fiducial markers were implanted into the prostate and through the rectum under ultrasound guidance around a week before radiotherapy. Glycerin enemas were given prior to each radiotherapy planning CT and every radiotherapy session. Hypofractionated radiotherapy was planned for a total dose of 59.5 Gy in daily 3.5 Gy with using the Novalis system. Orthogonal kV X-rays were taken before radiotherapy. Treatment positions were adjusted according to the results from the fusion of the fiducial markers on digitally reconstructed radiographs of a radiotherapy plan with those on orthogonal kV X-rays. When the difference in the coordinates from the fiducial marker fusion was less than 1 mm, the patient position was approved for radiotherapy. A virtual bone matching was carried out at the fiducial marker matched position, and then a setup difference between the fiducial marker matching and bone matching was evaluated. Results: Three patients received a planned 17-fractionated radiotherapy and the rest underwent 16 fractionations. The setup error of the fiducial marker matching was $0.94{\pm}0.62$ mm (range, 0.09 to 3.01 mm; median, 0.81 mm), and the means of the lateral, craniocaudal, and anteroposterior errors were $0.39{\pm}0.34$ mm, $0.46{\pm}0.34$ mm, and $0.57{\pm}0.59$ mm, respectively. The setup error of the pelvic bony matching was $3.15{\pm}2.03$ mm (range, 0.25 to 8.23 mm; median, 2.95 mm), and the error of craniocaudal direction ($2.29{\pm}1.95$ mm) was significantly larger than those of anteroposterior ($1.73{\pm}1.31$ mm) and lateral directions ($0.45{\pm}0.37$ mm), respectively (p<0.05). Incidences of over 3 mm and 5 mm in setup difference among the fractionations were 1.5% and 0% in the fiducial marker matching, respectively, and 49.3% and 17.9% in the pelvic bone matching, respectively. Conclusion: The more precise setup of hypofractionated radiotherapy for prostate cancer patients is feasible with the implanted fiducial marker matching compared with the pelvic bony matching. Therefore, a less marginal expansion of planning target volume produces less radiation exposure to adjacent normal tissues, which could ultimately make hypofractionated radiotherapy safer.

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

Deep Neck Abscesses in Korean Children (소아 심부 경부 농양에 대한 임상적 고찰)

  • Lee, Dae Hyoung;Kim, Sun Mi;Lee, Jung Hyun;Kim, Jong Hyun;Hur, Jae Kyun;Kang, Jin Han
    • Pediatric Infection and Vaccine
    • /
    • v.11 no.1
    • /
    • pp.81-89
    • /
    • 2004
  • Purpose : Retropharyngeal and parapharyngeal abscesses are often distinguishable from other head and neck abscesses on clinical grounds, but these infections can combine and the presentations are similar to one another. Because of the advances of antibiotic therapy, the frequency of the diseases decreased considerably, but recently the incidence of neck abscesses has increased. We sought to describe the clinical presentation of patients with deep neck abscess, and implications on management. Methods : For 10 year periods, 94 cases of charts were reviewed retrospectively, who were diagnosed as neck abscesses aged below 16 years old(between January 1993 to August 2003) in 4 hospitals. Deep neck abscesses were diagnosed by surgical pus drainage, neck CT (homogenous, hypodense area with ring enhancement) and neck sono findings. Results : The annual incidence of deep neck abscess has been increased since 2000. The median age of the patients was 4 years(range, 26 days~15 years); 63% of the patients were younger than 5 years. Abscesses in the submandibular space(34%) were most common, followed by peritonsillar space(29.7%), retropharyngeal space(11.7%), combined(10.8%), parotid space(7.4%) and parapharyngeal space(6.4%). Fever(73.4%), sore throat(37.2%), decreased oral intake(34%) and neck pain(27.7%) were the most common symptoms. In 6 children(6.4%), there was refusal to move neck, in 6(6.4%) headache, and in 4(4.3%) torticollis. Respiratory distress was observed in only 1 patient(2.1%) and stridor in 1 other(2.1%). The most common physical examinations were neck swelling/mass(67%), pharyngitis(46.8%), tonsillitis(36.2 %), and cervical lymphadenopathy(28.7%). Neck stiffness was observed in 4 patients(4.3%). Total 35 organisms were isolated in 33 patients. The most common organisms cultured by patients' blood or pus were S. aureus(34%) and S. pyogenes(28.6%). Most organisms were gram positive, and had sensitivities in vancomycin(96.4%), cefotaxime(88.9%), cephalothin (86.4%), trimethoprime-sulfamethoxazole(83.3%), and clindamycin(77.8%). 77 patients(81.9%) underwent surgery plus antibiotics; 17 patients(18.1%) were treated with antibiotics only. There is no significant differences between two groups. In duration of admission, fever after admission, and antibiotic treatment. Conclusion : The incidence of deep neck abscess has increased recently and the major symptoms have been changed. The incidence of respiratory distress or stridor is decreasing, while the incidence of abnormal head and neck symptoms and signs like headache, neck stiffness, refusal to move neck, or torticollis are increasing. Gram positive organisms are predominant, S. aureus is the most common followed by S. pyogenes. 1st generation cephalosporin has high sensitivity on gram positive organisms. Treatment with surgery plus antibiotics dose not significantly decrease total duration of antibiotic treatment or admission compared to treatment with antibiotics alone.

  • PDF