• Title/Summary/Keyword: path length

Search Result 791, Processing Time 0.03 seconds

TREATMENT OF ECTOPIC ERUPTING MANDIBULAR FIRST PERMANENT MOLAR CAUSED BY IMPROPERLY RESTORED STAINLESS STEEL CROWN : CASE REPORT (부적절하게 수복된 stainless steel crown에 의해 야기된 하악 제1대구치 이소맹출의 치험례)

  • Park, Chu-Seok;Choi, Byung-Jai;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.98-102
    • /
    • 2000
  • Ectopic eruption is out of a normal position by local eruption disturbance in the developing permanent molar. The prevalence of ectopic eruption is reported to be the between 2 and 6%, most often associated maxillary first permanent molar whereas, the occurrence for the mandibular is quite rare. The etiologic factors of ectopic eruption are inadequate arch length, lack of growth in the posterior region of the jaw, mesially inclined eruption path of first permanent molars, abnormally large first permanent molars, hereditary factor and a stainless steel crown which has been improperly restored. Ectopic eruption can be treated by the use of brass wire, separating elastics, distal disking and Humphrey appliance and the use of removable appliance and cervical traction headgear after extraction of the second primary molar. This case was that lower right first permanent molar was mesially tilted state by locking on the stainless steel crown of a lower right second primary molar. The stainless steel crown was removed and Humphrey appliance was set. Like this case, ectopic eruption could be happened by the stainless steel crown which improperly restored. In restoration of the stainless steel crown, selection of proper size, trimming and contouring are very important.

  • PDF

CORRECTION OF ECTOPIC ERUPTION WITH BILATERAL ANCHORAGE : REPORT OF CASES (양측성 고정원을 이용한 이소 맹출의 치료에 대한 증례 보고)

  • Ahn, Sung-Ihn;Shun, Ye-Kyung;Shim, Youn-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.446-452
    • /
    • 1999
  • Ectopic eruption of the first permanent molar means the first permanent molar assumes an atypical path of eruption resulting in premature atypical resorption of the second primary molar. If the reversible eruption does not occur, early loss of the second primary molars results in space loss, mesial tipping of the first permanent molar, impaction of the second premolar, buccal segment crowding and overeruption of opposing tooth. The main objectives of treatment are (1) to prevent loss of the second deciduous molars so it can continue to serve as a space maintainer and (2) to regain lost arch length, allowing the second premolar to erupt into normal position. The optimal treatment approach depends on a number of factors including the clinical eruption status of /6/, the change in position of /6/, the amount of enamel ledge of /E/ entrapping /6/, the mobility of /E/, and the presence of pain or infection. Unilateral appliance to correct the mesial angulation of ectopic permanent first molars, as in the majority of the appliance designs, would produce a resultant force that would further enhance the space loss. A bilateral support similar to the holding arch design is recommended to maximize the anchorage. These case reports present the successful result of preserving space for the second premolar in treatment of ectopic eruption of the first permanent molar using Halterman appliance with bilateral anchorage on patients visiting department of pediatric dentistry in Samsung Medical Center.

  • PDF

Analysis of dose from surface to near the buildup region in the therapeutic X-ray beam (표피로 부터 buildup 영역까지 흡수되는 암치료용 방사선의 선량분석)

  • Vahc, Young-Woo
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.41-50
    • /
    • 1995
  • The absorbed dose and contaminant electron distribution of therapeutic X-ray beam (15MV photon) was studied with a half blocked beams of 30$\times$30$\textrm{cm}^2$ and field size ranging from 5$\times$5 to 30$\times$30$\textrm{cm}^2$. For a 15MV photon beam energy, the value of the depth of dose maximum, d$_{max}$, gradually decrease with increasing field size from 5$\times$5 to 30$\times$30$\textrm{cm}^2$ due to mainly by contaminant electrons which are produced in the flattening filter and scattered by collimator jaws, tray holder〔Lucite〕, blocking block and air. The results suggest that separate dosimetry data should be kept for blocked and unblocked field. The inherence of the contaminant electrons to the open field depth of maximum dose can lead to mistaken results if attenuation measurements are made at that depth. A nurmerous contaminant electrons mainly were distributed as shape of corn in the central photon beam and their path length in the water were shorter than 30mm because of the electrons energy having around 6MeV. These results clearly appears that the substraction of scattered electrons (electrons and positrons) from the total depth dose curve not only lowers the absolute dose in the bulidup region and surface dose, it also causes a shift of d$_{max}$ to a deeper depth. In the terapeutic high energy photon beam, the absorbed dose near the buildup region is the combined result of incident contaminant electrons and phantom generated electronsrons.

  • PDF

Topic Modeling based Interdisciplinarity Measurement in the Informatics Related Journals (토픽 모델링 기반 정보학 분야 학술지의 학제성 측정 연구)

  • Jin, Seol A;Song, Min
    • Journal of the Korean Society for information Management
    • /
    • v.33 no.1
    • /
    • pp.7-32
    • /
    • 2016
  • This study has measured interdisciplinarity using a topic modeling, which automatically extracts sub-topics based on term information appeared in documents group unlike the traditional top-down approach employing the references and classification system as a basis. We used titles and abstracts of the articles published in top 20 journals for the past five years by the 5-year impact factor under the category of 'Information & Library Science' in JCR 2013. We applied 'Discipline Diversity' and 'Network Coherence' as factors in measuring interdisciplinarity; 'Shannon Entropy Index' and 'Stirling Diversity Index' were used as indices to gauge diversity of fields while topic network's average path length was employed as an index representing network cohesion. After classifying the types of interdisciplinarity with the diversity and cohesion indices produced, we compared the topic networks of journals that represent each type. As a result, we found that the text-based diversity index showed different ranking when compared to the reference-based diversity index. This signifies that those two indices can be utilized complimentarily. It was also confirmed that the characteristics and interconnectedness of the sub-topics dealt with in each journal can be intuitively understood through the topic networks classified by considering both the diversity and cohesion. In conclusion, the topic modeling-based measurement of interdisciplinarity that this study proposed was confirmed to be applicable serving multiple roles in showing the interdisciplinarity of the journals.

Kinetics of Seed Growth of α-Ferric Oxyhydroxide (α-Ferric oxyhydroxide 입자의 핵성장 반응에 관한 연구)

  • Seul, Soo-Duk;Shin, Dong-Ock
    • Applied Chemistry for Engineering
    • /
    • v.8 no.4
    • /
    • pp.602-609
    • /
    • 1997
  • The seed formation and growth of $\alpha$-ferric oxyhydroxide with aerial oxidative precipitation from aqueous solution of ferrous sulfate with KOH, NaOH, $Na_2CO_3$ and $K_2CO_3$ as precipitants have been studied by free pH drift experiment. It has been shown that all precipitants give same particle formation and growth path, and average particle length from KOH and NaOH as precipitants was about 1.5 times shorter than that of $K_2CO_3$ and $Na_2CO_3$. When initial mole ratio, $R_o=[Fe^{2+}]_o/[OH^-]_o$ of KOH was decreased the particle was grown oxyhydroxide seed growth from aqueous solution of ferrous sulfate with KOH has been studied. The influence of the air flow rate, reaction temperature and initial mole ratio, $R_o=[Fe^{2+}]_o/[OH^-]_o$, on the kinetics of seed growth are investigated by static pH experiment. The oxidation rate of seed growth increased with increase in the air low rate, reaction temperature and initial mole patio. The activation energy of seed growth is 16.16 KJ/mol and the rate equation of seed growth can be written as follows: $-\frac{d[Fe^{2+}]}{dt}=1.46{\times}10^4[P_{o2}]^{0.66}[OH^-]^{2.19}exp(-\frac{16.16}{dt})$.

  • PDF

Comparison of Hospital Standardized Mortality Ratio Using National Hospital Discharge Injury Data (퇴원손상심층조사 자료를 이용한 의료기관 중증도 보정 사망비 비교)

  • Park, Jong-Ho;Kim, Yoo-Mi;Kim, Sung-Soo;Kim, Won-Joong;Kang, Sung-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1739-1750
    • /
    • 2012
  • This study was to develop the assessment of medical service outcome using administration data through compared with hospital standardized mortality ratios(HSMR) in various hospitals. This study analyzed 63,664 cases of Hospital Discharge Injury Data of 2007 and 2008, provided by Korea Centers for Disease Control and Prevention. We used data mining technique and compared decision tree and logistic regression for developing risk-adjustment model of in-hospital mortality. Our Analysis shows that gender, length of stay, Elixhauser comorbidity index, hospitalization path, and primary diagnosis are main variables which influence mortality ratio. By comparing hospital standardized mortality ratios(HSMR) with standardized variables, we found concrete differences (55.6-201.6) of hospital standardized mortality ratios(HSMR) among hospitals. This proves that there are quality-gaps of medical service among hospitals. This study outcome should be utilized more to achieve the improvement of the quality of medical service.

Filtering Rate Model of Farming Oyster, Crassostrea gigas with effect of Water Temperature and Size (수온과 크기의 영향을 고려한 양식굴, Crassostrea gigas의 여수율 모형)

  • KIM Yong-Sool
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.5
    • /
    • pp.589-598
    • /
    • 1995
  • Filtering rates of Crassostrea gigas were experimentally investigated with reference to effects of water temperature and size. Absorptiometric determinations of filtering rates with oysters being fed diatom Chaetoceros calcirtans were carried out in a closed system. Optical density of 675nm in path length 100mm cell used as the indication of food particles absorption was appeared directly In proportion with the concentration of diatom pigment $chlorophyll-\alpha$. In the closed system where $C_0$ is $OD_{675}$ at initial time 0, $C_t$, at time t, and Z is the decreasing coefficient of OD as meaning of instantaneous removal speed, then $C_t=C_0{\cdot} e^{-2t}$, $Z=In(C_t/C_0)/t$. On the assumption that the filtering rate is constant, then removal rate per unit time (d) is $d=-e^{-z}$. If t is used to time unit of hour (hr), the filtering rate (FR) in I/hr is given by $FR=V{\cdot}d=V(1-e^{-z})$, where V is the water volume (I) of the experimental vessel. Filtering rate increased as exponential function with increasing temperature while not over critical limit. The critical temperature for filtering rate was assumed to be between $28^{\circ}C$ and $29^{\circ}C$. And the weight exponent for filtering rate is 0.223. The model formula derived from the results as FR, $Ihr^{-1}$ = $Exp(0.208{\cdot}T-4.324){\cdot} (DW)^{0.223}$ (T<29 $^{\circ}C)$ where T is water temperature $(^{\circ}C

  • PDF

THE FORCED ERUPTION OF IMPACTED MAXILLARY INCISOR: CASE REPORT (매복된 상악 중절치의 교정적 견인을 이용한 치험례)

  • Kim, Jong-Sik;Kim, Eun-Jung;Kim, Hyun-Jung;Nam, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.26-32
    • /
    • 2005
  • A tooth impaction means a state that a tooth does not erupt out of oral mucosa or alveolar bone for many reasons. The reasons for an impaction of the Maxillary central incisor are an odontoma, supernumerary tooth, space loss, prolonged remaining or early loss of a preceding deciduous tooth, abnormalities of crown or root caused by trauma of a deciduous tooth and an ectopic position of a tooth germ. In the case of the impacted maxillary incisor, a rapid mesial movement of a lateral incisor leads a space loss and a midline deviation can be happened. Furthermore, it can cause a cyst. When we treated a patient with an impacted central incisor early, we could see a better prognosis. It means an early diagnosis and an exact treatment are very important. Generally if the impaction is not severe or it is caused by a keratinized covering tissue, a surgical exposure can induce an eruption easily but an orthodontic force is recommended when an eruption does not happen after a surgical method, when the eruption path is too transpositioned to be corrected spontaneously and when an impacted tooth is located so deeply. In the treatment using an orthodontic force, careful considerations about a root length, pulp, and a periodontal tissue can improve the periodontal and esthetic prognosis for the long follow-up results. This case is using an orthodontic traction following a periodic observation and in no expectation of spontaneous eruption. After treatment of this case, I have got some knowledges, so I report this case.

  • PDF

ZnO nanostructures for e-paper and field emission display applications

  • Sun, X.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.993-994
    • /
    • 2008
  • Electrochromic (EC) devices are capable of reversibly changing their optical properties upon charge injection and extraction induced by the external voltage. The characteristics of the EC device, such as low power consumption, high coloration efficiency, and memory effects under open circuit status, make them suitable for use in a variety of applications including smart windows and electronic papers. Coloration due to reduction or oxidation of redox chromophores can be used for EC devices (e-paper), but the switching time is slow (second level). Recently, with increasing demand for the low cost, lightweight flat panel display with paper-like readability (electronic paper), an EC display technology based on dye-modified $TiO_2$ nanoparticle electrode was developed. A well known organic dye molecule, viologen, was adsorbed on the surface of a mesoporous $TiO_2$ nanoparticle film to form the EC electrode. On the other hand, ZnO is a wide bandgap II-VI semiconductor which has been applied in many fields such as UV lasers, field effect transistors and transparent conductors. The bandgap of the bulk ZnO is about 3.37 eV, which is close to that of the $TiO_2$ (3.4 eV). As a traditional transparent conductor, ZnO has excellent electron transport properties, even in ZnO nanoparticle films. In the past few years, one-dimension (1D) nanostructures of ZnO have attracted extensive research interest. In particular, 1D ZnO nanowires renders much better electron transportation capability by providing a direct conduction path for electron transport and greatly reducing the number of grain boundaries. These unique advantages make ZnO nanowires a promising matrix electrode for EC dye molecule loading. ZnO nanowires grow vertically from the substrate and form a dense array (Fig. 1). The ZnO nanowires show regular hexagonal cross section and the average diameter of the ZnO nanowires is about 100 nm. The cross-section image of the ZnO nanowires array (Fig. 1) indicates that the length of the ZnO nanowires is about $6\;{\mu}m$. From one on/off cycle of the ZnO EC cell (Fig. 2). We can see that, the switching time of a ZnO nanowire electrode EC cell with an active area of $1\;{\times}\;1\;cm^2$ is 170 ms and 142 ms for coloration and bleaching, respectively. The coloration and bleaching time is faster compared to the $TiO_2$ mesoporous EC devices with both coloration and bleaching time of about 250 ms for a device with an active area of $2.5\;cm^2$. With further optimization, it is possible that the response time can reach ten(s) of millisecond, i.e. capable of displaying video. Fig. 3 shows a prototype with two different transmittance states. It can be seen that good contrast was obtained. The retention was at least a few hours for these prototypes. Being an oxide, ZnO is oxidation resistant, i.e. it is more durable for field emission cathode. ZnO nanotetropods were also applied to realize the first prototype triode field emission device, making use of scattered surface-conduction electrons for field emission (Fig. 4). The device has a high efficiency (field emitted electron to total electron ratio) of about 60%. With this high efficiency, we were able to fabricate some prototype displays (Fig. 5 showing some alphanumerical symbols). ZnO tetrapods have four legs, which guarantees that there is one leg always pointing upward, even using screen printing method to fabricate the cathode.

  • PDF

Radiologic study of intraosseous path of the inferior alveolar cantal, mental canal, and mental foramen for endosseous implants (인공치아 매식술을 위한 하악관, 이관, 이공의 골내 주행에 관한 방사선학적 연구)

  • Hong, So-Mi;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.4
    • /
    • pp.933-948
    • /
    • 1996
  • The purpose of this study was to examine the anatomic structures of the mandible-inferior alveolar canal, mental foramen, mental canal-with panoramic radiography and conventional tomography and to compare both radiographic techniques in conjunction with endosseous implants. In this study 14 adult dentulous mandibles -27 cases of right and left side of mandibles- were examined and the results were as follows. 1. The distance between superior border of the inferior alveolar canal and the alveolar ridge crest showed a decreasing tendency from the mental foramen to 4cm posterior to the mental foramen. 2. The mean diameter of the inferior alveolar canal was $4.11{\pm}0.50mm$ with panoramic radiography and $3.29{\pm}0.59mm$ with conventional tomography. 3. The inferior border of the inferior alveolar canal and inferior border of the mandible was closest at 2cm posterior to the mental foramen but it was not statistically significant. the mean distance was $1l.64{\pm}2.95mm$ in panoramic radiography and $1l.68{\pm} 2.91mm$ in conventional tomography. 4. The inferior alveolar canal located lingually in bucco-lingual direction 16%(mental foramen), 54%(lcm posterior to the mental foramen), 68%(2cm posterior to the mental foramen), 50%(3cm posterior to mental foramen), 55%(4cm posterior to the mental foramen). 5. Mean length of the anterior loop of the mental canal was 2.73mm, and the loop below 2mm was 35% and 15% of mental canal was invisible in panoramic radiography. 6. The minimum interforaminal distance was 56.7mm, the maximum distance was 73.2mm and the mean distance was 66.42mm in panoramic radiography. 7. The mean distance between midpoint of the mental canal and alveolar ridge crest was 16.24mm and the mean buccolingual angulation of the mental canal was $52.98^{\circ}$ in conventional tomography. 8. In comparison of panoramic radiography and conventional tomography, inferior alveolar canal is better visualized with conventional tomography than panoramic radiography from the mental foramen to the 2cm posterior to the mental foramen, while visiblity of conventional tomography prominently decreased in 4cm posterior to the mental foramen and alveolar ridge crest is better visualized with panoramic radiography than conventional radiography at the mental foramen and at 4cm posterior to the mental foramen. In radiologic examination of anatomic structures of the mandible for endosseous implants, panoramic radiography and conventional tomography can be effectively used when it is used to overcome the anatomic limitations.

  • PDF