• 제목/요약/키워드: passive samplers

검색결과 61건 처리시간 0.018초

확산포집기로 공기중 ppb 농도수준의 휘발성유기물질 포집시 확산길이와 기류변화가 시료포집속도에 미치는 영향 (The effects of face velocity and path length on the uptake rates of volatile organic compounds measured by diffusive samplers)

  • 변상훈;톰 스톡;마리아 모란디;아프샤;제이 크로스
    • 한국산업보건학회지
    • /
    • 제11권1호
    • /
    • pp.34-41
    • /
    • 2001
  • Passive samplers have been used for personal, indoor, and outdoor air monitoring of VOCs at ppb concentrations in community and office environments. The path length of modified passive sampler was shortened, so it was intended to increase an uptake rate. The performance of the modified 3M 3500 organic vapor monitor(OVM) as a tool for assessing exposures to toxic air pollutants in nonoccupational community environments was evaluated using combined controlled test atmospheres of six selected target volatile organic compounds(VOCs): benzene, methyl tert-butyl ether(MTBE), chloroform, 1,4-dichlorobenzene, tetrachloroethylene, and toluene. The experiments were conducted by exposing the dosimeters to concentrations of $50{\sim}100{\mu}g/m^3$ on six face velocity(0.00, 0.02, 0.06, 0.12, 0.20, 0.30 m/sec) for 24 hours. If the uptake rate was increased, that means that we could use the passive sampler more effectively. The uptake rates were increased linearly according to reduce the path length. Although the diffusion path length was shortened, the change of uptake rate was within ${\pm}25%$ of theoretical value, indicating that the modified passive sampler(TM) can be effectively used over the range of concentrations and environmental conditions tested with a 24-h sampling period if the face velocities were over 0.12 m/s for 6 components of VOCs. But when the face velocities were less than 0.12 m/s, uptake rates were reduced more than expected values. So, the passive sampler with the shortened path length should be used at indoor or outdoor environment where the face velocity should be over about 0.10 m/s. If the path length was shortened more, the uptake rate was more effected by starvation.

  • PDF

소나무잎에 침착된 PCDD/Fs 특성 (Characteristics of PCDD/Fs Deposited on Pine Needles)

  • 천만영
    • 대한환경공학회지
    • /
    • 제27권6호
    • /
    • pp.599-605
    • /
    • 2005
  • 대기중 POPs의 passive sampler로 많이 이용되고 있는 1년에서 4년생 까지의 소나무잎을 이용하여 대기중 PCDD/Fs가 소나무잎에 침착될 때의 특성을 연구하였다. 치환된 염소수가 적어 대기 중에서 주로 가스상으로 존재하는 PCDD/Fs는 소나무잎에 누적침착이 일어나지만 입자상으로 존재하는 PCDD/Fs는 누적침착이 일어나지 않았다. 소나무잎에 침착된 PCDD/Fs는 광분해로 농도가 감소되었는데, PCDFs의 광분해율은 PCDDs와 비슷하였고 염소치환수가 많은 homologue일수록 광분해율이 컸다. 소나무잎을 대기중 PCDD/Fs의 passive sampler로 사용할 때 가스상과 입자상 PCDD/Fs의 잎에 대한 누적침착율 차이와 광분해에 의한 오차를 줄이기 위하여 어린 잎을 시료로 채취하는 것이 좋으며, 지역별 PCDD/Fs 농도를 비교할 때에는 동일한 나이의 소나무잎을 채취하여야 오차를 줄일 수 있다.

나이별 소나무 잎에 침착된 대기 중 폴리브롬화디페닐에테르 특성 (Characteristics of Atmospheric Polybrominated Diphenyl Ethers (PBDEs) Deposited on Pine Needles by Age)

  • 천만영
    • 한국환경보건학회지
    • /
    • 제40권4호
    • /
    • pp.313-321
    • /
    • 2014
  • Objectives: Pine needles are used as passive air samplers (PAS) of atmospheric persistent organic pollutants (POPs). This study was carried out in order to investigate whether pine needles can also be used as a PAS of polybrominated diphenyl ethers (PBDEs). Methods: PBDEs in one to three year-old pine needles were analyzed with HRGC/HRMS. Results: PBDEs in the atmosphere were accumulated in the pine needles. The rate of increase in concentration of lower substituted PBDEs (tri- through hepta-) in pine needles was linear. The rate of increase of the higher substituted PBDEs (octa- through deca-) was also liner, but only up to two year-old pine needles. The concentration did not increase further in older pine needles. Conclusion: Therefore, it can be concluded that young pine needles, those that are two years old or less, are recommended for use as PAS of atmospheric PBDEs.

토양 간극수의 효율적 포집을 위한 오염물질 제거에 관한 연구 (A Study of Contaminant Removal for Pore-Water Collection)

  • 이성백
    • 한국토양환경학회지
    • /
    • 제4권1호
    • /
    • pp.69-73
    • /
    • 1999
  • PCAPS는 토양 간극수를 효율적으로 포집하기 위해서 fiberglass wick의 모세관 잠재력을 이용하여 토양오염을 조사하는 장치이다. Fiberglass에 붙어 있는 불순물은 wick의 모세관 성질과 포집된 시료의 화학적 성질에 영향을 미치게 되므로 4가지 처리방법들 (소각처리, 아세톤처리, 세정제처리, 비세척)을 이용하여 불순물을 제거하였다. Wick은 미국의 PPG Industries와 Manville Company에서 생산되는 제품을 사용하였다. 실험결과로, PPG fiber는 소각처리에 의해 원래 부피의 3.4%정도 손실되었으며, Manville fiber 는 0.6%미만이 손실되었다. 이들 손실은 제작과정에 사용된 유기합성물이 소각되면서 발생하였다. 모든 세척방법들은 비세척 방법보다 모세관의 상승높이가 더 크게 나타났다. 소각이 가장 좋은 세척방법으로 나타났으며 40$0^{\circ}C$의 온도에서 4시간 처리시 불순물의 98~100%를 제거할 수 있었다.

  • PDF

Assessment of Occupational Symptoms and Chemical Exposures for Nail Salon Technicians in Daegu City, Korea

  • Park, Sung-Ae;Gwak, Sugyeong;Choi, Sangjun
    • Journal of Preventive Medicine and Public Health
    • /
    • 제47권3호
    • /
    • pp.169-176
    • /
    • 2014
  • Objectives: This study aimed to evaluate occupational symptoms and chemical exposures of nail salon technicians. Methods: Work-related symptoms of nail salon technicians in Daegu City were surveyed using a researcher-administered questionnaire, and responses were compared to those of non-exposed office workers as controls. Personal exposure level of airborne volatile organic compounds was also monitored using passive samplers. Results: A total of 159 subjects in 120 salons were interviewed. Average work-shift concentrations of 13 chemicals were measured for 50 workers from 30 salons using personal passive samplers. The most frequently reported respiratory or neurologic symptoms by nail shop technicians compared to controls were nose irritation (odds ratio [OR], 54.0; confidence interval [CI], 21.6 to 134.8), followed by headache (OR, 9.3; CI, 4.7 to 18), and throat irritation (OR, 4.3; CI, 2.2 to 8.5). For eyes and skin, 92% of respondents complained eye irritation (OR, 13.1; CI, 5.7 to 30.1). In musculoskeletal symptoms, workers reported pain or discomfort in shoulders (OR, 20.3; CI, 7.7 to 54) and neck (OR, 19.7; CI, 8.9 to 43.6). From personal measurements, the proportion of exceeding the Korean Occupational Exposure Limit was the highest for acetone with 64%, followed by toluene (50%), butyl acetate (46%), and methyl methacrylate (12%). However, the service was being provided without a proper ventilation system in most surveyed shops. Conclusions: Based on these findings, it is warranted to have appropriate local exhaust ventilation place to ensure adequate health protection of nail shop technicians as well as customers. At the same time, greater policy interests are warranted in nail care business to protect health of both workers and customers.

소나무 잎을 PAS로 이용하여 대기 중 PCDD/Fs 농도 추정 (Estimation of PCDD/Fs Concentrations in Ambient Air Using Pine Needles as a Passive Air Sampler (PAS))

  • 천만영
    • 한국환경보건학회지
    • /
    • 제41권2호
    • /
    • pp.116-125
    • /
    • 2015
  • Objective: This study was carried out to use pine needles as a passive air sampler (PAS) for atmospheric polychlorinared dibenzo-p-dioxins/furans (PCDD/Fs). Methods: PCDD/Fs concentrations in ambient air ($C_a$, $pg/m^3$) and deposited pine needles ($C_p$, pg/g dry) were analyzed simultaneously from June 1 to December 31. Air samples were taken using two low volume PUF active air samplers with an overall average air volume of approximately $1,200Sm^3$. Pine needles were collected the end of December near the air sampler. PCDD/Fs was analyzed by HRGC/HRMs. Results: A good correlation was shown ($R^2=0.6357$, p=0.0001) between $C_a$ and $C_p$, but a better correlation ($R^2=0.7372$, p<0.0001) existed between the logarithm of octanol-air partitioning coefficient ($LogK_{oa}$) and Log($C_p/C_a$). The average PCDD/Fs sampling rates from air to pine needles were 0.045($0.018-0.185m^3/day-g\;dry$). Conclusion: It was found that pine needles can be used as PAS for atmospheric PCDD/Fs, and they are especially suitable for long time PAS compared to PUF disk PAS.

대기 중 PCBs의 PAS에 이용되는 여러 매체의 PCBs 침착 특성 (Depositional Characteristics of Atmospheric PCBs in Several Media Used Passive Air Samplers)

  • 천만영
    • 한국환경보건학회지
    • /
    • 제39권2호
    • /
    • pp.151-158
    • /
    • 2013
  • Objective: This study was carried out to determine the depositional characteristics of pine needles, pine tree bark, moss, and soil, which are used as a passive air sampler (PAS) of atmospheric polychlorinated biphenyls (PCBs). Methods: All four media were sampled from the same site. PCB concentrations were analyzed by GC/MSD, and the lipid contents were measured using the gravimetric method. Results: The total PCB concentration (IUPAC No. 28, 52, 101, 138, 153, 180) was the highest in soil (227.97 pg/g dry), followed by pine needles (71.36 pg/g dry), pine tree bark (44.58 pg/g dry), then moss (21.91 pg/g dry). Pine needles contained the highest lipid contents (21.31 mg/g dry), whereas soil (10.01 mg/g dry), pine tree bark (4.85 mg/g dry), and moss (1.92 mg/g dry) contained less. The concentration of lower-chlorinated PCBs was relatively high in pine needles, pine tree bark and moss, but not in soil. The PCB concentrations were proportional to their lipid contents in pine needles, pine tree bark and moss, but a different trend was revealed in soil. Conclusions: The PCBs concentrations in the media were affected by various factors including atmospheric PCB concentrations, lipid contents, and depositional pathways. However, each of these factors had a varying influence depending on the type of medium.

안면도에서 대기 중 가스상 PAHs의 계절적 변동 (Seasonal Variation of Atmospheric Polycyclic Aromatic Hydrocarbons (PAHs) on Anmyeon Island)

  • 안준건;임운혁;심원준;김기범;김승규;이희일
    • Ocean and Polar Research
    • /
    • 제31권2호
    • /
    • pp.189-198
    • /
    • 2009
  • Passive air samplers with polyurethane foam (PUF) disks were employed to determine seasonal gas phase variation of polycyclic aromatic hydrocarbons (PAHs) in ambient air on Anmyeon island from March 2007 to January 2008. Sum of 13 PAHs ranged between $3.5\;ng/m^3$ and $27.6\;ng/m^3$. Total PAHs during the heating season was 6.2 times higher than non-heating season. The dominant PAHs components during sampling periods were low and middle molecular weight PAHs including phenanthrene, fluoranthene, pyrene and chrysene. Gas exchange fluxes of PAHs across the air-water interface of the Yellow Sea were calculated using a modified two-film exchange model. PAHs fluxes ranged from $196\;ng/m^2/d$ net volatilization during summer to $3830\;ng/m^2/d$ net absorption during winter. Passive air sampler provides a convenient and cost-effective tool for measuring averaged gas phase PAHs, which was successfully used for calculation of gas exchange flux of PAHs in the Yellow Sea.

확산형 포집기와 활성탄관을 이용한 공기중 혼합 유기용제 측정에 관한 연구 (Comparison of Passive Diffusional Organic Vapor Samplers with Charcoal Tubes for the Measurement of Mixed Organic Solvents)

  • 안규동;연유용;이병국
    • 한국산업보건학회지
    • /
    • 제4권2호
    • /
    • pp.127-136
    • /
    • 1994
  • 활성탄관을 이용한 작업환경 공기중 유기용제의 시료채취는 여러 가지 어려운 점이 있으나 확산형 시료포집기는 이러한 점을 보완하는 새로운 포집기이다. 따라서 본 연구는 확산형 시료포집기가 혼합 유기용제를 사용하는 사업장을 대상으로 확산형 포집기와 활성탄관을 이용, 한 근로자에 대하여 동시에 각 1개씩, 총 181개의 시료를 포집하여 활성탄과 어떠한 차이가 있는 가를 확인하며, 고전적인 활성탄관 시료채취법을 대신할 수 있는 가를 확인하기 위하여 시도한 바 몇가지의 결과를 얻어 보고하는 바이다. 1. 활성탄관 시료포집기에 비하여 확산형의 시료포집기는 톨루엔(toluene), 키시렌(xylene) 등의 방향족 화합물은 다소 높은 농도를 나타내나 전반적으로 통계적인 유의성은 없었다. 2. 엠이케이(methyl ethyl ketone)와 시크로헥사논(c-hexanone)에 대하여 확산형 포집기는 적어도 저농도(허용농도의 1/8 및 1/10 이하농도)에서 활성탄관에 비하여 약 2배 정도 높게 측정되었다(p<0.01). 그러나 공기중 엠이케이와 시크로헥사논의 농도가 증가함에 따라서 확산형의 포집효율은 활성탄관 보다 적은 것으로 나타났다. 3. 활성탄관의 측정치(B)를 1.00으로 하였을 때 확산형 포집기(A)의 측정치 비(A/B)는 톨루엔의 경우 1.11, 키시렌은 1.07, 엠이케이는 1.63, 시크로헥사논은 3.65배 였다. 4. 활성탄관과 확산형 포집기에서의 측정치 비가 0.75-1.25 범위(${\pm}25%$)에 드는 것은 톨루엔 57%, 키시렌 74%였으며, 엠이케이 34%, 시크로헥사논은 약 32%에 불과하였다. 5. 활성탄관과 확산형 포집기에서의 측정치 간의 각 유기용제 별 상관은 톨루엔 0.963, 키시렌 0.957, 엠이케이 0.943, 시크로헥사논은 0.562로서 모두 통계적으로 유의하였다.

  • PDF

VOCs의 위해성 평가를 위한 노출분석 방법 연구 (The Development of Exposure Assessment Tools for Risk Assessment of Volatile Organic Compounds)

  • 조성준;신동천;정용;이덕희
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권2호
    • /
    • pp.147-160
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health issue in Korea and many important questions remain to be addressed with respect to assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in their analytic determination Valid Personal exposure assessment methods are needed to evaluate exposure frequency, duration and intensity, as well as their relationship to personal exposure characteristics. Biological monitoring is also important since it may contribute significantly in risk assessment by allowing the estimation of effective absorbed doses. This study was on ducted to establish the environmental measurement, personal dosimetry and biological monitoring methods for VOCs. These methods are needed to compare blood, urinary and exhalation breath VOC levels and to provide tools for risk assessment of VOC exposure. Passive monitors (badge type) and a active samplers (trap) for the VOCs collection were used for air sampling. Methods development included determining the minimum detectable amounts of VOCs in each media, as well as evaluating collection methods and developing analytical procedures. Method reliability was assessed by determining breakthrough volumes and comparing results between laboratories and with other methods. A total capacity of trap used in this study was 60ι. Although variable by compound, the average breakthrough was 20%. Also, there was no loss of compounds in trap even if keep for 45 day in -7$0^{\circ}C$. The recovery of active and passive methods was 69% ~ 126% and method detection limit was 0.24 $\mu\textrm{g}$/trap and 0.07 $\mu\textrm{g}$/badge. There was no statistical difference (P > 0.05) between active and passive methods.