• 제목/요약/키워드: passive samplers

검색결과 61건 처리시간 0.025초

수동측정기에 의한 대기오염 자동측정망의 지역대표성 조사 및 보완방완에 대한 기초연구 (Evaluation and Complement of the Representativeness of Air Quality Monitoring Stations Using Passive Air Samplers)

  • 우정현;김선태;김정욱
    • 한국대기환경학회지
    • /
    • 제13권6호
    • /
    • pp.415-426
    • /
    • 1997
  • Some arguments have been about over the representativeness of government-run air quality monitoring stations among scholars and non-governmental organizations (NGOs). However, it is not a simple problem to move monitoring stations because of continuity of data and high cost. So it is necessary to complement the monitoring data if it do not represent the ambient air quality properly. The purpose of this study was to evaluate the representativeness of some monitoring stations using passive $NO_2$ samplers and to find a complementary method from linear regression. Two stations were chosen for the evaluation: Shinlim Station was one of the most controversial stations in Seoul and Banpo Station had the best reputation. Air qualities were surveyed at seven points around each monitoring station with consideration of land use and distance. The ratios of the average $NO_2$ levels of the areas to these at the monitoring stations were 1.59 for Shinlim Station and 1.03 for Banpo Station. The differences between the average $NO_2$ levels and those at the monitoring stations were 10.75 ppb for Shilim Station and 0.34 ppb for Banpo Station. The correlation coefficients between the two levels were 0.7668 for Shinlim and 0.7662 for Banpo. The average coefficients of determination $(R^2)$ were 0.61 for Shinlim and 0.61 for Banpo. The Shinlim Station could not represent the air quality of Shinlim-Dong good because it is located in a green area at an outskirt of Shinlim-Dong. But the Banpo Station located in a central residential area of Banpo-Dong showed a fair representativeness. However, air quality turned out to be different with land use such as residential area, green area or road: the air quality data from a monitoring station located at a certain land use should not be interpreted as representing the air quality at any sites around the station. Equations to predict the average $NO_2$ levels of each area from the data from the monitoring stations were presented based on linear regression.

  • PDF

Relationship between PAHs Concentrations in Ambient Air and Deposited on Pine Needles

  • Chun, Man-Young
    • Environmental Analysis Health and Toxicology
    • /
    • 제26권
    • /
    • pp.4.1-4.6
    • /
    • 2011
  • Objectives: This study was carried out to determine whether or not pine needles can be used as passive samplers of atmospheric polycyclic aromatic hydrocarbons (PAHs) using the correlation between accumulated PAH concentrations in air (Ca, ng/$m^3$) and those deposited on pine needles (Cp, ng/g dry). Methods: PAHs in ambient air was collected using low volume PUF sampler and pine needles was gathered at same place for 7 months. Results: A good correlation ($R^2$=0.8582, p<0.05) was found between Ca and Cp for PAHs with a higher gaseous state in air (AcPy, Acp, Flu, Phen, Ant, Flt, Pyr, BaA and Chry), but there was a poorer correlation ($R^2$=0.1491, p=0.5123) for the PAHs with a lower gaseous state (BbF, BkF, BaP, DahA, BghiP and Ind123). A positive correlation ($R^2$=0.8542) was revealed between the logarithm of the octanol-air partitioning coefficient ($logK_{oa}$) and Cp/Ca for the PAHs with a higher gaseous state in air, but there was a negative correlation ($R^2$=0.8131) for the PAHs with a lower gaseous state. The Ca-Cp model could not be used to estimate PAHs concentrations in air using deposited PAHs concentrations on pine needles, but the logKoa-Cp/Ca model could be used. Conclusions: It was found that pine needles can be used as passive samplers of atmospheric PAHs.

Evaluation of an Ammonia Passive Sampler Using Chamber System

  • Yim, Bong-Been;Kim, Sun-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제22권E1호
    • /
    • pp.1-8
    • /
    • 2006
  • The purpose of this study was to evaluate the efficiency of a passive sampler in measuring atmospheric ammonia concentrations using chamber system. The ability of the passive sampler to quantitatively determine atmospheric ammonia gas was almost identical to that of the reference method (indophenol method). There was no significant difference between concentrations measured by the two methods. The detection and quantification limits of the ammonia passive sampler were 16.9 ppb and 25.3 ppb, respectively, for a 24-h sampling period. The average coefficient of variation between replicated samplers was $6.7{\pm}4.2%$. The concentrations measured by the two methods (passive sampler and indophenol method) were no significant difference with good a correlation (correlation coefficient=0.964).

새로운 생물농축 기법에 의한 PAHs의 오염도 확인 (Use of New Passive Sampler to Assess PAHs Contamination)

  • 박정규;황인영;문성환;정홍배
    • Environmental Analysis Health and Toxicology
    • /
    • 제16권4호
    • /
    • pp.171-179
    • /
    • 2001
  • A new passive sampler was developed, improving SPMD (Semipermeable Membrane Devices) that contained triolein in nonporous, low-density polyethylene layflat tubing. Experiments to measure PAHs concentration were carried out at four sites (Dukpo, Sochi, Sohwonggando, Yeonmok) on the southern coast of Korea that were contaminated by oil spills. Passive samplers were deployed at 4 and 8 week intervals at each site. Results showed that bioconcentration levels of PAHs were increased in proportion to exposure duration from all sample sites and accumulation in the passive sampler was much higher than in biota at the Dukpo site. Results of these tests suggest that new passive sampler is a useful tool for measuring bioconcentration organic compounds in aquatic environments.

  • PDF

폴리우레탄 폼 수동형 공기시료채취기를 이용한 대기 중 다이옥신/퓨란 농도 측정 (Measurement of Atmospheric PCDD/Fs Concentrations Using Polyurethane Foam Disk Passive Air Samplers)

  • 김태욱;천만영
    • 한국환경보건학회지
    • /
    • 제42권2호
    • /
    • pp.102-111
    • /
    • 2016
  • Objectives: This study was conducted to evaluate the use of polyurethane foam disk passive air samplers (PUF PAS) for better measurement of atmospheric polychlorinared dibenzo-p-dioxins/furans (PCDD/Fs) concentrations compared to PUF PAS combined with high volume air samplers (HVS). Methods: Air samples were collected by a low volume air sampler (LVS) and PUF PAS. A total of two pairs were continuously collected for six months, but the PUF was replaced every two months. Results: A good correlation was shown ($R^2=0.8595$, p<0.0001) between atmospheric PCDD/Fs concentration measured by the LVS and PUF PAS. The average air sampling rate ($1.5m^3/day-sampler$) of all PCDD/Fs congeners showed a middle of the means which were measured using a HVS by other researchers in different cities. In addition, the air sampling rates of the LVS for each congener made less difference than did those of the HVS. Conclusion: It was found that measurements using the LVS were less influenced by atmospheric peak PCDD/Fs concentrations. However, trace POPs such as PCDD/Fs may involve relatively large analytical errors in measurement, and as a result the air sampling rate of the respective PCDD/Fs isomer is also likely to involve errors. The method of using a regression straight line between the concentrations obtained from the LVS and those from the PUF PAS was judged higher than the method using the air sampling rate, since the former compensated for the experimental errors in the process of evaluation of atmospheric PCDD/F concentrations using the PUF PAS.

연구참여자에 의한 주택실내 휘발성 유기화합물 농도의 측정 (Measurement of Residential Volatile Organic Compound Exposure Through A Participant-Based Method)

  • 황윤형;이기영;김서진;홍윤철;전종관;조수헌
    • 한국환경보건학회지
    • /
    • 제37권5호
    • /
    • pp.369-375
    • /
    • 2011
  • Objectives: Exposure to hazardous chemicals during pregnancy may result incritical reproductive health outcomes. Indoor residential levels are significant component of personal exposure. The collection of residential exposure data has been hampered by the cost and participant burden of health studies of indoor air pollution. This study utilized a participant-based approach to collect volatile organic compounds concentration from homes. Methods: Four hundred thirteen women were recruited from three major hospitals in Seoul and Gyeongi Provence and 411 agreed to participate. A passive sampler (OVM 3500, 3M, USA) with instructions were given to the participants, as well as a questionnaire. They were asked to deploy the sampler in their homes for three to five days and return them viapre-stamped envelope. Results: Three hundred forty six participants returned the sampler. Among the returned samplers, three hundred samplers satisfied our monitoring quality criteria. The success rate of the monitoring method was 73%. The geometric mean of TVOC level was 429(2) ${\mu}g/m^3$. The TVOC guideline of 500 ${\mu}g/m^3$ was exceeded in 38% of the houses. The residential VOC levels were significantly associated with remodeling of the house. Conclusions: The results suggested that a participant-based sampling approach may be a feasible and costeffective alternative to exposure assessment involving home visits by a field technician.

장기 NO2 및 SO2 Passive Diffusive Sampler(PDS)를 이용한 대전시 대기질 모니터링 (Air Quality Monitoring in Daejeon City with Long-Term NO2 and SO2 Passive Diffusive Samplers)

  • 임봉빈;김선태;정재호;이범진
    • 한국환경과학회지
    • /
    • 제16권2호
    • /
    • pp.187-195
    • /
    • 2007
  • Long-term passive diffusive samplers(PDS) have been used to measure $NO_2\;and\;SO_2$ concentrations at 21 sampling sites in Daejeon, Korea during the period of January 2000 - December 2002. The spatial distributions of annual $NO_2\;and\;SO_2$ concentrations were mapped. Average annual $NO_2$ concentration over the sampling period was $28.5{\pm}12.5\;ppb$, ranging from 1.2 to 81.7 ppb. Average annual $SO_2$ concentration over the sampling period was $7.7{\pm}4.8\;ppb$, ranging from 0.6 to 26.8 ppb. On average, $NO_2$ concentration was approximately 5.8%(1.6 ppb) larger in 2002. $SO_2$ concentration was decreased by 13%(1.1 ppb) during the sampling period. The seasonal variation of $NO_2\;and\;SO_2$ concentration was observed with a tendency to be higher in fall and winter. $NO_2\;and\;SO_2$, concentrations measured at different site types(patterns of land use) show significant difference. The observed difference in concentration was associated with difference in emissions of $NO_2$ from motor vehicles and $SO_2$ by non-traffic fuel consumption for heating.

Passive Sampler를 이용한 $SO_2$ 공간농도분포 조사와 토양오염 상관성 연구 (A Study on Correlations between Distribution of Sulfur Dioxide Concentration and Soil Environments by Using Passive Samplers)

  • 송영배
    • 대한환경공학회지
    • /
    • 제27권10호
    • /
    • pp.1025-1029
    • /
    • 2005
  • 공단지역에서 아황산가스의 오염농도와 공간분포를 조사하기 위해 토지이용 유형별로 약 500 m 격자망을 구성하여 76개의 지점에 패시브샘플러를 설치하여 분석을 수행하였다. 또한 아황산가스를 비롯한 대기오염물질이 공업단지, 주거지 및 녹지지역의 토양에 미치는 오염영향을 파악하기 위해 120개 지점에서 토양시료를 채취하여 토성과 중금속 농도를 분석하였다. 분석결과 아황산가스 농도와 Cu 및 Pb와의 상관도는 0.05 및 0.04로 낮게 도출되었으나, 공업지역만을 대상으로 분석하였을 경우 상관도는 0.17 및 0.08로서 각각 3.3배와 2배 증가한 것으로 분석되었다. 위 연구결과는 대기오염농도의 공간분포 및 토양오염과의 상관성을 파악할 수 있도록 공업지역, 주거지역 및 녹지지역으로 구분하여 도면에 표시하였으며, 연구결과는 인간, 동 식물이 장기간 오염환경에 노출정도와 대기위생 및 공중보건 위험성평가를 위한 자료로 활용될 수 있다.

Man-in-Simulant Test(MIST) 실험을 위한 다양한 흡착제의 화학증기 흡착용 샘플러 제작 (Facile Fabrication of Chemical Vapor Samplers with Various Adsorbents for Man-in-Simulant Test(MIST))

  • 정현숙;이규원;최근섭;박명규;이해완
    • 한국군사과학기술학회지
    • /
    • 제17권1호
    • /
    • pp.129-134
    • /
    • 2014
  • We have developed a cost-effective and facile method to manufacture a pouch-type chemical vapor sampler. Originally, the sampler was developed by U. S. Army Natick Soldier Research, Development, and Engineering Center(NSRDEC) to determine the protective capability of individual protective ensembles or Man-in-Simulant Test (MIST). They used a selectively permeable high density polyethylene(HDPE) as front membrane and aluminum/ Nylon barrier film as an impermeable back sheet in order to mimic the actual adsorption process that occurs when the skin is exposed to chemical weapons. However, it costs over twenty dollars per sampler and the minimum of quantity is 2500 per order. In addition, it is inconvenient to employ a variety of adsorbents into the sampler, which could prevent MIST researchers to do various tests for development of MIST methodologies. Here, we report the simple method to manufacture the sampler in a laboratory scale. All the materials we used are easily obtainable and inexpensive. In addition, all the procedures we perform are generally known. We used methyl salicylate(MeS) vapor to be adsorbed into the sampler and employed several different adsorbents to evaluate the performance of samplers. The results obtained by home-made samplers and commercially avaliable one showed no significant differences. Also, MeS vapor was selectively adsorbed into the sampler depending on adsorbents. We conclude that home-made samplers are capable of collecting any kind of chemical vapor for a variety of purposes.

Evaluation of Short-Term CO2 Passive Sampler for Monitoring Atmospheric CO2 Levels

  • Yim, Bongbeen;Sim, Yoon-Ah;Kim, Sun-Tae
    • 한국기후변화학회지
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 2016
  • In this study, we investigated the applicability of a short-term carbon dioxide ($CO_2$) passive sampler using turbidity change in a solution containing barium hydroxide ($Ba(OH)_2$). The mass of $CO_2$ introduced into the $Ba(OH)_2$ aqueous solution was strongly correlated ($r^2=0.9565$) to the change in turbidity caused by its reaction with the solution. The sampling rates calculated for 1 h and 24 h were $42.4{\pm}5.4mL\;min^{-1}$ and $2.3{\pm}0.3mL\;min^{-1}$, respectively. Both unexposed (blank) and exposed samplers remained stable during the storage period of at least two weeks. The detection limits of the passive sampler for $CO_2$ were 81.5 ppm for 1 h and 61.5 ppm for 24 h. Based on the results, the passive sampler using the change of turbidity in the $Ba(OH)_2$ aqueous solution appears to be a suitable tool for measuring short-term atmospheric concentrations of $CO_2$.