• 제목/요약/키워드: passive pressure

검색결과 330건 처리시간 0.028초

피동 주입 시험 장치의 척도 해석 및 설계 방법론 연구 (Study on Scaling Analysis and Design Methodology of Passive Injection Test Facility)

  • 배황;이민규;류성욱;신수재;김영인;이성재;박현식
    • 한국유체기계학회 논문집
    • /
    • 제19권5호
    • /
    • pp.50-60
    • /
    • 2016
  • A design methodology of the modeled test facility to conserve an injection performance of a passive safety injection system is proposed. This safety injection system is composed of a core makeup tank and a safety injection tank. Individual tanks are connected with pressure balance line on the top side and injection line on the bottom side. It is important to conserve the scaled initial injection flow rate and total injection time since this system can be operated by small gravity head without any active pumps. Differential pressure distribution of the injection line induced by the gravity head is determined by the vertical length and elevation of each tank. However, the total injection time is adjustable by the flow resistance coefficient of the injection line. The scaling methodology for the tank and flow resistance coefficient is suggested. A key point of this test facility design is a scaling analysis for the flow resistance coefficient. The scaling analysis proposed on this paper is based on the volume scaling law with the same vertical length to the prototype and can be extended to a model with a reduced vertical length. A set of passive injection test were performed for the tanks with the same volume and the different length. The test results on the initial flow rate and total injection time showed the almost same injection characteristics and they were in good agreement with the design values.

한쪽 다리에 적용한 수축-이완 기법이 반대쪽 무릎관절 폄 범위에 미치는 효과 -예비연구- (The Immediate Effects of Unilateral Contract-Relax Stretching on Contralateral Knee Extension Range -A Preliminary Study-)

  • 신승섭
    • PNF and Movement
    • /
    • 제17권2호
    • /
    • pp.263-274
    • /
    • 2019
  • Purpose: This article was conducted to determine the immediate effects of unilateral contract-relax (CR) stretching on contralateral knee extension range and to compare both sides of the knee extension range between experimental and control groups. Methods: This study recruited 16 adult males and females with straight leg raising abilities below $90^{\circ}$. The subjects were randomly divided into an experimental group and a control group comprising 8 subjects each. The experimental group performed direct CR stretching on the right hamstring muscles with straight hip extension adduction, and the control group performed indirect CR stretching on the right hamstring muscles with straight hip flexion abduction. Each group performed CR stretching 4 times with 4 repetitions comprising 10 sec of contraction and a 10 sec break between repetitions. Before and after the CR stretching exercises, the subjects' passive knee extensions were measured at the hip in a $90^{\circ}$ flexed position. The subjects' peak force on the right leg and peak pressure on the left leg during each CR stretching exercise were also measured. Results: After doing CR stretching 4 times, each group showed a significantly increased passive knee extension range on both sides, and there was no difference in the passive knee extension ranges between the groups. The peak force on the right leg was significantly higher in the experimental group than the control group. There was no difference in peak pressure between the groups. Conclusion: After applying unilateral CR stretching, the study subjects experienced a significantly increased passive knee extension range on the contralateral side. For patients who find it difficult to apply stretching techniques to knee joints directly, the use of the proprioceptive neuromuscular facilitation technique of CR stretching may be useful in improving the range of the knee joint on the contralateral side without direct treatment.

슬롯 형상이 경사충격파 간섭유동의 피동제어에 미치는 영향에 관한 연구 (Effects of Slot Configurations on the Passive Control of Oblique-Shock-Interaction Flows)

  • 장성하;이열
    • 한국항공우주학회지
    • /
    • 제34권12호
    • /
    • pp.18-24
    • /
    • 2006
  • 슬롯과 다공판을 이용한 충격파와 난류 경계층 간섭유동의 피동제어에 관한 연구가 수행되었다. 슬롯의 다양한 형상 변화가 간섭유동에 미치는 영향이 관찰되었으며, 이를 위하여 간섭유동 후방에서 피토/벽압력 분포 및 쉴리렌, 유맥선, 오일막 간섭 줄무늬 형상과 같은 유동가시화 결과 등이 얻어졌다. 유동방향의 슬롯의 경우 간섭유동 후방에서 제어되지 않은 경우와 비교하여 보다 높은 피토압력이 국소적으로 관찰되었으나, 폭방향 슬롯제어는 전체적으로 제어되지 않은 경우에 비하여 피토압력 크기에서 큰 장점을 보이지 않았다.

보조공동을 이용한 초음속 공동내부의 압력진동 저감에 관한 연구 (A Study on the Reduction of Supersonic Cavity Pressure Oscillations Using a Sub-Cavity System)

  • 신춘식;정준창;;김희동
    • 한국추진공학회지
    • /
    • 제13권5호
    • /
    • pp.41-47
    • /
    • 2009
  • 2차원 초음속 공동유동에서 발생하는 압력진동을 제어하기 위한 목적으로, 본 연구에서는 수치해석적 연구를 수행하였다. 본 계산에서는 압력진동을 제어하기 위하여 보조공동의 형상을 변화시켰으며, 유동의 마하수를 1.50, 1.83 그리고 2.50로 변화시켰다. 그 결과, 보조공동은 압력진동을 상당히 감소시켰으며, 압력진동의 제어효과는 유동의 마하수와 보조공동의 상세형상에 크게 의존함을 알았다.

수치해석을 이용한 패시브 마이크로 믹서의 성능평가 (Performance Assessment of Passive Micromixer using Numerical Analysis)

  • 이정익;김철규
    • 한국융합학회논문지
    • /
    • 제9권10호
    • /
    • pp.237-242
    • /
    • 2018
  • 마이크로 믹서는 랩-온-어-칩이나 마이크로 유체 기기의 하나의 구성품으로 두 가지의 화학 물질을 혼합(융합)하는 장치이다. 본 연구는 다양한 형상의 패시브 마이크로 믹서의 성능을 평가하는 것을 목적으로 한다. 다양한 형상의 마이크로 믹서는 총 6가지의 형상을 비교하였고, 서로 동일한 수력 직경을 갖도록 3차원 모델링하였다. 내부 혼합 유동을 전산모사하기 위해여 상용 유동해석 프로그램인 ANSYS Fluent를 사용하였다. 수치해석 방법은 본 논문에 자세하게 기술하였다. 마이크로 믹서의 성능 평가는 혼합 지수와 압력 강하로 비교하였고, 결론적으로 CDM-8T은 합리적인 혼합성능과 상대적으로 낮은 압력 강하를 갖는 것으로 나타났다.

PASTELS project - overall progress of the project on experimental and numerical activities on passive safety systems

  • Michael Montout;Christophe Herer;Joonas Telkka
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.803-811
    • /
    • 2024
  • Nuclear accidents such as Fukushima Daiichi have highlighted the potential of passive safety systems to replace or complement active safety systems as part of the overall prevention and/or mitigation strategies. In addition, passive systems are key features of Small Modular Reactors (SMRs), for which they are becoming almost unavoidable and are part of the basic design of many reactors available in today's nuclear market. Nevertheless, their potential to significantly increase the safety of nuclear power plants still needs to be strengthened, in particular the ability of computer codes to determine their performance and reliability in industrial applications and support the safety demonstration. The PASTELS project (September 2020-February 2024), funded by the European Commission "Euratom H2020" programme, is devoted to the study of passive systems relying on natural circulation. The project focuses on two types, namely the SAfety COndenser (SACO) for the evacuation of the core residual power and the Containment Wall Condenser (CWC) for the reduction of heat and pressure in the containment vessel in case of accident. A specific design for each of these systems is being investigated in the project. Firstly, a straight vertical pool type of SACO has been implemented on the Framatome's PKL loop at Erlangen. It represents a tube bundle type heat exchanger that transfers heat from the secondary circuit to the water pool in which it is immersed by condensing the vapour generated in the steam generator. Secondly, the project relies on the CWC installed on the PASI test loop at LUT University in Finland. This facility reproduces the thermal-hydraulic behaviour of a Passive Containment Cooling System (PCCS) mainly composed of a CWC, a heat exchanger in the containment vessel connected to a water tank at atmospheric pressure outside the vessel which represents the ultimate heat sink. Several activities are carried out within the framework of the project. Different tests are conducted on these integral test facilities to produce new and relevant experimental data allowing to better characterize the physical behaviours and the performances of these systems for various thermo-hydraulic conditions. These test programmes are simulated by different codes acting at different scales, mainly system and CFD codes. New "system/CFD" coupling approaches are also considered to evaluate their potential to benefit both from the accuracy of CFD in regions where local 3D effects are dominant and system codes whose computational speed, robustness and general level of physical validation are particularly appreciated in industrial studies. In parallel, the project includes the study of single and two-phase natural circulation loops through a bibliographical study and the simulations of the PERSEO and HERO-2 experimental facilities. After a synthetic presentation of the project and its objectives, this article provides the reader with findings related to the physical analysis of the test results obtained on the PKL and PASI installations as well an overall evaluation of the capability of the different numerical tools to simulate passive systems.

초고압 발효 더덕 추출물의 인지능력 개선 효과 (Memory Enhancing Effect of Codonopsis lanceolata by High Hydrostatic Pressure Process and Fermentation)

  • 원진배;이보형;윤보라;이지우;이현용;박동식;정희철;정재윤;마충제
    • 생약학회지
    • /
    • 제44권1호
    • /
    • pp.41-46
    • /
    • 2013
  • Alzheimer's disease (AD), most common form of dementia is characterized that memory deficit and loss of cognitive function. The Codonopsis lanceolata (C.lanceolata) was treated by high hydrostatic pressure process and fermentation. This study was evaluated cognitive enhancing effect C.lanceolata extract by high hydrostatic pressure process and fermentation and compared with common C.lanceolata extract using Morris water maze and passive avoidance test. And their neuroprotective effect on glutamate induced oxidative stress in HT22 cell was investigated by MTT assay. High hydrostatic pressure process and fermented C.lanceolata extract (HFCE) and common C.lanceolata extract (CCE) (100 and 300 mg/kg) were administered to mice. Results showed HFCE enhanced cognitive function than CCE as shown by decrease in escape latency time. HFCE increased the latency time of the passive avoidance test compared to CCE. Furthermore, HFCE showed significant neuroprotective effect against glutamate cytotoxicity in HT22 cells. These results indicate that high hydrostatic pressure process and fermented more improve spatial cognitive ability of C. laanceolata.

관 경사출구에 부착된 플랜지가 소음방사에 미치는 영향 (The effect of the flange attached to the inclined exit of tube on the noise radiation)

  • 백두산;양윤상;이동훈;이영균
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.134-137
    • /
    • 2014
  • The noise reduction performance of a passive facility is dependent on the its length or volume. In other words, this means that the larger the size of passive facility is, the better the noise reduction performance is. The sound directivity control has been proposed as an alternative for the noise reduction without a passive facility. The purpose of this study is to investigate the correlation between the flange attached to inclined exit of the tube and sound directivity when the sound radiates from the tube to the outside. As a result, the sound radiated from flanged tube had weak sound directivity in the wide angle. Also as the flange was bigger, the sound pressure level was lower in the behind the flange.

  • PDF

압력에 따른 평행박막 밸브의 자율 변형을 이용한 수동형 유량 제어기의 동적특성 평가 (Dynamic Characterization of Passive Flow-Rate Regulator Using Pressure-Dependent Autonomous Deflection of Parallel Membrane Valves)

  • 도일;조영호
    • 대한기계학회논문집B
    • /
    • 제35권8호
    • /
    • pp.825-829
    • /
    • 2011
  • 본 연구에서는, 미소유체시스템 상에서 정밀한 유체 제어를 위해 입력압력이 변하여도 일정한 유량을 유지할 수 있는 수동형 유량제어기를 개발함에 있어, 주기적으로 변화하는 압력에 대한 유량제어기의 동적특성을 평가하였다. 압력 변화의 주기보다 짧은 시간 내에 유량을 측정하기 위하여 입자영상속도계(Particle Image Velocimetry, PIV) 방법을 이용하였다. 지름이 $0.7{\mu}m$ 인 형광입자가 담긴 탈이온수를 유량제어기에 공급하고, 펄스레이저와 형광현미경을 이용하여 $10{\mu}s$ 간격의 연속된 사진을 얻고 이를 분석하여 유량제어기를 통과한 후의 유체의 속도를 측정하였다. 개발된 유량제어기는 20kPa 과 50kPa 사이를 주기적으로 변화하는 60Hz 의 압력 하에서 0.194${\pm}$0.014m/s의 일정한 유속을 유지함을 실험적으로 확인하였다. 압력의 주파수를 1~60Hz 까지 변화시켜가며 수행한 실험에서도 유량제어기는 압력의 주파수에 상관없이 $5.82{\pm}0.29\;{\mu}l/s$ 의 일정한 유량 공급이 가능함을 확인하였다.

차량 능동 현가 장치용 유압 액추에이터의 감쇠력 특성에 관한 연구 (A Study on the Characteristics of Damping Force in a Hydraulic Actuator for Vehicle Active Suspension System)

  • 윤영환;최명진
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.150-158
    • /
    • 2002
  • Through experimental works, the damping force vibration problem was investigated, which results from valve and surge pressure in the oil return line of the hydraulic circuit of an active suspension system in a passenger cu. Experiments were carried out under passive system, where an orifice valve was closed and non-active system, where an orifice valve was opened, using a pressure control valve controlled by solenoid. The effects of parameters of the valve overlap and accumulator on smoothing surge pressure was elucidated. It was proved that the apparent variation of damping force due to the overlap amount of pressure control valve is the most important factor to control the damping force variation. The procedure of the experimental works shows the development process of a proportional pressure control valve in the hydraulics system of an active suspension system of passenger car.