A design methodology of the modeled test facility to conserve an injection performance of a passive safety injection system is proposed. This safety injection system is composed of a core makeup tank and a safety injection tank. Individual tanks are connected with pressure balance line on the top side and injection line on the bottom side. It is important to conserve the scaled initial injection flow rate and total injection time since this system can be operated by small gravity head without any active pumps. Differential pressure distribution of the injection line induced by the gravity head is determined by the vertical length and elevation of each tank. However, the total injection time is adjustable by the flow resistance coefficient of the injection line. The scaling methodology for the tank and flow resistance coefficient is suggested. A key point of this test facility design is a scaling analysis for the flow resistance coefficient. The scaling analysis proposed on this paper is based on the volume scaling law with the same vertical length to the prototype and can be extended to a model with a reduced vertical length. A set of passive injection test were performed for the tanks with the same volume and the different length. The test results on the initial flow rate and total injection time showed the almost same injection characteristics and they were in good agreement with the design values.
Purpose: This article was conducted to determine the immediate effects of unilateral contract-relax (CR) stretching on contralateral knee extension range and to compare both sides of the knee extension range between experimental and control groups. Methods: This study recruited 16 adult males and females with straight leg raising abilities below $90^{\circ}$. The subjects were randomly divided into an experimental group and a control group comprising 8 subjects each. The experimental group performed direct CR stretching on the right hamstring muscles with straight hip extension adduction, and the control group performed indirect CR stretching on the right hamstring muscles with straight hip flexion abduction. Each group performed CR stretching 4 times with 4 repetitions comprising 10 sec of contraction and a 10 sec break between repetitions. Before and after the CR stretching exercises, the subjects' passive knee extensions were measured at the hip in a $90^{\circ}$ flexed position. The subjects' peak force on the right leg and peak pressure on the left leg during each CR stretching exercise were also measured. Results: After doing CR stretching 4 times, each group showed a significantly increased passive knee extension range on both sides, and there was no difference in the passive knee extension ranges between the groups. The peak force on the right leg was significantly higher in the experimental group than the control group. There was no difference in peak pressure between the groups. Conclusion: After applying unilateral CR stretching, the study subjects experienced a significantly increased passive knee extension range on the contralateral side. For patients who find it difficult to apply stretching techniques to knee joints directly, the use of the proprioceptive neuromuscular facilitation technique of CR stretching may be useful in improving the range of the knee joint on the contralateral side without direct treatment.
슬롯과 다공판을 이용한 충격파와 난류 경계층 간섭유동의 피동제어에 관한 연구가 수행되었다. 슬롯의 다양한 형상 변화가 간섭유동에 미치는 영향이 관찰되었으며, 이를 위하여 간섭유동 후방에서 피토/벽압력 분포 및 쉴리렌, 유맥선, 오일막 간섭 줄무늬 형상과 같은 유동가시화 결과 등이 얻어졌다. 유동방향의 슬롯의 경우 간섭유동 후방에서 제어되지 않은 경우와 비교하여 보다 높은 피토압력이 국소적으로 관찰되었으나, 폭방향 슬롯제어는 전체적으로 제어되지 않은 경우에 비하여 피토압력 크기에서 큰 장점을 보이지 않았다.
2차원 초음속 공동유동에서 발생하는 압력진동을 제어하기 위한 목적으로, 본 연구에서는 수치해석적 연구를 수행하였다. 본 계산에서는 압력진동을 제어하기 위하여 보조공동의 형상을 변화시켰으며, 유동의 마하수를 1.50, 1.83 그리고 2.50로 변화시켰다. 그 결과, 보조공동은 압력진동을 상당히 감소시켰으며, 압력진동의 제어효과는 유동의 마하수와 보조공동의 상세형상에 크게 의존함을 알았다.
마이크로 믹서는 랩-온-어-칩이나 마이크로 유체 기기의 하나의 구성품으로 두 가지의 화학 물질을 혼합(융합)하는 장치이다. 본 연구는 다양한 형상의 패시브 마이크로 믹서의 성능을 평가하는 것을 목적으로 한다. 다양한 형상의 마이크로 믹서는 총 6가지의 형상을 비교하였고, 서로 동일한 수력 직경을 갖도록 3차원 모델링하였다. 내부 혼합 유동을 전산모사하기 위해여 상용 유동해석 프로그램인 ANSYS Fluent를 사용하였다. 수치해석 방법은 본 논문에 자세하게 기술하였다. 마이크로 믹서의 성능 평가는 혼합 지수와 압력 강하로 비교하였고, 결론적으로 CDM-8T은 합리적인 혼합성능과 상대적으로 낮은 압력 강하를 갖는 것으로 나타났다.
Nuclear accidents such as Fukushima Daiichi have highlighted the potential of passive safety systems to replace or complement active safety systems as part of the overall prevention and/or mitigation strategies. In addition, passive systems are key features of Small Modular Reactors (SMRs), for which they are becoming almost unavoidable and are part of the basic design of many reactors available in today's nuclear market. Nevertheless, their potential to significantly increase the safety of nuclear power plants still needs to be strengthened, in particular the ability of computer codes to determine their performance and reliability in industrial applications and support the safety demonstration. The PASTELS project (September 2020-February 2024), funded by the European Commission "Euratom H2020" programme, is devoted to the study of passive systems relying on natural circulation. The project focuses on two types, namely the SAfety COndenser (SACO) for the evacuation of the core residual power and the Containment Wall Condenser (CWC) for the reduction of heat and pressure in the containment vessel in case of accident. A specific design for each of these systems is being investigated in the project. Firstly, a straight vertical pool type of SACO has been implemented on the Framatome's PKL loop at Erlangen. It represents a tube bundle type heat exchanger that transfers heat from the secondary circuit to the water pool in which it is immersed by condensing the vapour generated in the steam generator. Secondly, the project relies on the CWC installed on the PASI test loop at LUT University in Finland. This facility reproduces the thermal-hydraulic behaviour of a Passive Containment Cooling System (PCCS) mainly composed of a CWC, a heat exchanger in the containment vessel connected to a water tank at atmospheric pressure outside the vessel which represents the ultimate heat sink. Several activities are carried out within the framework of the project. Different tests are conducted on these integral test facilities to produce new and relevant experimental data allowing to better characterize the physical behaviours and the performances of these systems for various thermo-hydraulic conditions. These test programmes are simulated by different codes acting at different scales, mainly system and CFD codes. New "system/CFD" coupling approaches are also considered to evaluate their potential to benefit both from the accuracy of CFD in regions where local 3D effects are dominant and system codes whose computational speed, robustness and general level of physical validation are particularly appreciated in industrial studies. In parallel, the project includes the study of single and two-phase natural circulation loops through a bibliographical study and the simulations of the PERSEO and HERO-2 experimental facilities. After a synthetic presentation of the project and its objectives, this article provides the reader with findings related to the physical analysis of the test results obtained on the PKL and PASI installations as well an overall evaluation of the capability of the different numerical tools to simulate passive systems.
Alzheimer's disease (AD), most common form of dementia is characterized that memory deficit and loss of cognitive function. The Codonopsis lanceolata (C.lanceolata) was treated by high hydrostatic pressure process and fermentation. This study was evaluated cognitive enhancing effect C.lanceolata extract by high hydrostatic pressure process and fermentation and compared with common C.lanceolata extract using Morris water maze and passive avoidance test. And their neuroprotective effect on glutamate induced oxidative stress in HT22 cell was investigated by MTT assay. High hydrostatic pressure process and fermented C.lanceolata extract (HFCE) and common C.lanceolata extract (CCE) (100 and 300 mg/kg) were administered to mice. Results showed HFCE enhanced cognitive function than CCE as shown by decrease in escape latency time. HFCE increased the latency time of the passive avoidance test compared to CCE. Furthermore, HFCE showed significant neuroprotective effect against glutamate cytotoxicity in HT22 cells. These results indicate that high hydrostatic pressure process and fermented more improve spatial cognitive ability of C. laanceolata.
The noise reduction performance of a passive facility is dependent on the its length or volume. In other words, this means that the larger the size of passive facility is, the better the noise reduction performance is. The sound directivity control has been proposed as an alternative for the noise reduction without a passive facility. The purpose of this study is to investigate the correlation between the flange attached to inclined exit of the tube and sound directivity when the sound radiates from the tube to the outside. As a result, the sound radiated from flanged tube had weak sound directivity in the wide angle. Also as the flange was bigger, the sound pressure level was lower in the behind the flange.
본 연구에서는, 미소유체시스템 상에서 정밀한 유체 제어를 위해 입력압력이 변하여도 일정한 유량을 유지할 수 있는 수동형 유량제어기를 개발함에 있어, 주기적으로 변화하는 압력에 대한 유량제어기의 동적특성을 평가하였다. 압력 변화의 주기보다 짧은 시간 내에 유량을 측정하기 위하여 입자영상속도계(Particle Image Velocimetry, PIV) 방법을 이용하였다. 지름이 $0.7{\mu}m$ 인 형광입자가 담긴 탈이온수를 유량제어기에 공급하고, 펄스레이저와 형광현미경을 이용하여 $10{\mu}s$ 간격의 연속된 사진을 얻고 이를 분석하여 유량제어기를 통과한 후의 유체의 속도를 측정하였다. 개발된 유량제어기는 20kPa 과 50kPa 사이를 주기적으로 변화하는 60Hz 의 압력 하에서 0.194${\pm}$0.014m/s의 일정한 유속을 유지함을 실험적으로 확인하였다. 압력의 주파수를 1~60Hz 까지 변화시켜가며 수행한 실험에서도 유량제어기는 압력의 주파수에 상관없이 $5.82{\pm}0.29\;{\mu}l/s$ 의 일정한 유량 공급이 가능함을 확인하였다.
Through experimental works, the damping force vibration problem was investigated, which results from valve and surge pressure in the oil return line of the hydraulic circuit of an active suspension system in a passenger cu. Experiments were carried out under passive system, where an orifice valve was closed and non-active system, where an orifice valve was opened, using a pressure control valve controlled by solenoid. The effects of parameters of the valve overlap and accumulator on smoothing surge pressure was elucidated. It was proved that the apparent variation of damping force due to the overlap amount of pressure control valve is the most important factor to control the damping force variation. The procedure of the experimental works shows the development process of a proportional pressure control valve in the hydraulics system of an active suspension system of passenger car.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.