• 제목/요약/키워드: passive pressure

검색결과 329건 처리시간 0.027초

전해 연마액 금속 이온 농도에 따른 스테인리스 스틸의 부동태 피막 형성 거동 (Formation Behavior of Passive State Film on Stainless Steel for Metallic Ion Concentration in Electropolishing Solution)

  • 오종수;강은영;정대용
    • 한국재료학회지
    • /
    • 제32권4호
    • /
    • pp.230-236
    • /
    • 2022
  • The formation behavior of a passive state film on the surface of STS304 in electrolytic solution was analyzed to determine its metallic ion composition. The properties of passive state films vary depending on the Fe and Cr ions in the electrolytic solution. It was observed that the passive state film surface became flat and glossy as the concentration of Fe and Cr ions in the electrolytic solution increased. The corrosion resistance property of the passive state film was proportional to the amount of Fe and Cr in the electrolytic solution. An initial passive state film with high Fe concentration was formed on the surface of STS304 during early electrolytic polishing. Osmotic pressure of Fe ions occurs between the passive state film and electrolytic solution due to the Fe ion concentration gradient. The Fe in the passive state film is dissolved into the electrolyte, and Cr fills up the Fe ion vacancies. As a result, a good corrosion-resistant floating film was formed. The more Fe ions in the electrolytic solution, the faster the film is formed, and as a result, a flat passive state film containing a large amount of Cr can be formed.

피동제어법을 이용한 초음속 공동유동의 진동 제어 (Control of Supersonic Cavity Flow Oscillation Using Passive Means)

  • 이영기;;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.363-366
    • /
    • 2006
  • 본 연구에서는 초음속 공동유동장에서 발생하는 압력 진동을 완화시키기 위하여 사용된 두 가지 피동제어방법들의 유효성을 수치해석적으로 조사하였다. 사용된 제어 장치들은 삼각돌기와 sub-cavity로, 전단층의 발달 특성을 조절하기 위하여 공동 전단 부근에 설치된다. 공동유동의 압력변동 특성을 조사하기 위하여 3차원 비정상 Navier-Stokes 방정식에 유한체적법을 적용하여 유동장을 모사하였으며, 유동의 난류상태량들은 LES 방법을 사용하여 계산하였다. 그 결과, 공동유동의 진동 특성은 공동의 후단 벽면에서 발생하는 압력 진동에 의해 지배되며, 제시된 방법들의 효과는 공동의 후단에서 가장 크게 나타났다. 특히, sub-cavity는 삼각돌기나 블로잉이 있는 경우에 비하여 압력 진동 저감효과가 상대적으로 크며, sub-cavity가 큰 경우 압력 진동의 저감효과가 더욱 뚜렷하게 나타났다.

  • PDF

Research on the Urban Ecological Space Changes under Modern Passive Industrialization Case Study of Zhengzhou City in China

  • Yang, Juntao;Baek, Seungman
    • Architectural research
    • /
    • 제23권2호
    • /
    • pp.29-37
    • /
    • 2021
  • Early in the communist era, many cities in modern China experienced a special period of passive industrialization during which the construction of urban spaces laid the spatial urban foundation. During this period, the city construction was carried out rapidly under the administrative intervention of the government. The passive industrialization caused by taking economic construction as the center made the city construction deviate from the correct track and resulted in a variety of problems. Focusing on ecological space change, this paper selects Zhengzhou as an example of many similar cities in China, and analyzes the impact of passive industrialization on urban ecological spaces from the perspectives of city scale, city layout and city construction management system. The analysis results reveal that the construction of urban ecological space under the influence of passive industrialization induced a lagging characteristic, led to insufficient integrity of urban ecological space, and placed great pressure on the urban environment. Finally, the paper puts forward some methods to optimize the urban ecological space.

수동폐확장과 능동호흡강화 기법이 건강한 성인 폐기능에 미치는 영향 (The Effect of Passive Lung Expansion Technique and Active Respiration Enhancement Technique on Lung Function in Healthy Adults)

  • 이동진;이연섭
    • 대한통합의학회지
    • /
    • 제8권4호
    • /
    • pp.155-161
    • /
    • 2020
  • Purpose : This study was conducted to investigate the effect of positive active pressure technique and active breathing technique on lung function in healthy adults. Methods : In this study, the passive lung expansion technique and active respiration enhancement technique using an air mask bag unit were conducted in 30 normal adults to observe changes in pulmonary function with forced vital capacity (FVC), Forced expiratory volume at one second (FEV1). In order to observe the change in the level of respiratory function, we would like to investigate the peak expiratory flow (PEF) and the forced expiratory flow (FEF 25-75 %). Results : As a result of this study, there was no significant difference in comparison between the passive lung expansion technique and the active breathing enhancement technique (p>.05). The passive lung expansion technique effectively increased the effortful expiratory volume and the median expiratory flow rate of 1 second (p<.05). And the passive lung expansion technique effectively increased the effortless lung capacity and the maximum expiration flow rate (p<.05). Conclusion : The passive lung expansion technique effectively increases the range of motion of the lungs and chest cages, intrathoracic pressure, and elasticity of the lungs, and the active breathing technique increases the muscle functions such as the diaphragm and the biceps muscles. It is expected that it will be able to selectively improve the respiratory function of patients with respiratory diseases or functional limitations as it is found to be effective.

관절의 수동탄성특성을 이용한 족부의 생체역학적 해석 (Biomechanical Analysis of the Human Foot by Using Passive Elastic Characteristics of Joints)

  • 김시열;최현기
    • 한국정밀공학회지
    • /
    • 제21권1호
    • /
    • pp.197-204
    • /
    • 2004
  • In this study we presented kinematic and kinetic data of foot joints using approximated equations and partial plantar pressure during gait. The maximum angular displacements of each tarsometatarsal joint were found to range from 4$^{\circ}$to 7$^{\circ}$ and the maximum moments were from 200Nㆍcm to 1500Nㆍcm. It was relatively wide distribution. Foot kinematic data calculated from the approximated equations, which were represented by the correlation between moment and angular displacement, and the data from motion analysis were similar. We found that the movements of foot joint were mainly decided by the passive characteristics of the joint when ground reaction force acts. The method of kinematic and kinetic analysis using approximated equations which is presented in this study is considered useful to describe the movements of foot joints in gait simulations.

A Study on the Passive Microvalve Applicable to Drainage Device for Glaucoma

  • Sim, Tae-Seok;Kim, Yong-Kweon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제2권4호
    • /
    • pp.253-258
    • /
    • 2002
  • This paper reports the design, modeling, fabrication and measurement of passive microvalves, which are applicable to glaucoma implants. The proposed microvalves were designed using fluidic theory. The microvalves consisted of microchannels and chambers. The microchannels had a constant fluidic resistance generating a pressure difference. Six kinds of microvalves were designed using fluidic equations for laminar flow and fabricated to examine the influences of chamber size, channel length and the shape of channel cross section. The pressure difference between the designed microvalve and the fabricated microvalve was measured to be less than 4%.

골반 중립에 따른 뒤넙다리근 수동 신장 운동이 유연성과 족저압에 미치는 영향 (Effects of the Stretching Exercise of Hamstring Muscle on Flexibility and Foot Pressure in Subjects with and without Pelvis Neutral Position)

  • 조민지;권나영;박수민;서동현;정재령;하미선;양회송;정찬주;유영대;전현주
    • 대한통합의학회지
    • /
    • 제4권1호
    • /
    • pp.31-39
    • /
    • 2016
  • Purpose : The purpose of this study was to investigate the effects of flexibility and foot pressure on stretching exercise of hamstring muscle with and without pelvis neutral position. Methods : This study was performed on 30 subjects. Thirty subjects were divided into two group; hamstring passive stretching exercise with pelvis neutral position(n=15), hamstring passive stretching exercise without pelvis neutral position(n=15). Both of the group performed the exercise 4 times a week for 6 weeks. The data was analyzed by the paired t-test for comparing before and after changes of factors in each group and the independent t-test for comparing the between groups. Results : The results were as follows. There was statistically significant difference of before and after hamstring flexibility, foot pressure in pelvis neutral position(p<0.05). There was statistically significant difference of before and after hamstring flexibility, foot pressure without pelvis neutral position group(p<0.05). There was no statistically significant difference of between the two group in hamstring flexibility, foot pressure(p>0.05). Conclusion : As a result of this study, though no statistically significant difference of the between groups, we suggest that stretching exercise of hamstring muscle with pelvic neutral may be effective more than stretching exercise of hamstring muscle without pelvic neutral in flexibility, foot pressure.

어깨관절의 수동적 내회전 관절 가동범위의 측정 방법에 따른 신뢰도와 상완골두의 전방 활주 거리 비교 (A Comparison of Reliability and Anterior Glide Distance of Humerus Head of Passive Shoulder Internal Rotation Range of Motion Measurement Methods)

  • 김현숙;이원휘;정성대
    • 한국전문물리치료학회지
    • /
    • 제17권3호
    • /
    • pp.1-10
    • /
    • 2010
  • The purpose of this study was to measure intra-rater and inter-rater reliability and range of motion for measurement of passive shoulder internal rotation range of motion and to compare anterior glide distance of humeral head in three methods. Fifty healthy subjects and fifty patients with shoulder musculoskeletal pain were recruited for this study. The subjects' passive shoulder internal rotation range of motion was measured by visual estimation, manual stabilization, and pressure biofeedback unit methods. In two trials, measurements were performed on each subject by two examiners. Intraclass correlation coefficient (ICC(3,1)) was used to determine the reliability of each measurement. The intra-rater reliability of the three methods was excellent (ICC=.77~.93) in both groups. The inter-rater reliability of the visual estimation method was poor (ICC=.20, .29), the manual scapular stabilization method was poor and fair (ICC=.09, .50), and the pressure biofeedback unit method was excellent (ICC .86, .75) in the experimental and control groups. In the experimental group, the difference of examined range of motion by each examiner was significant in the visual estimation method and manual scapular stabilization method, but there was an insignificant difference between the groups is the pressure biofeedback unit method. This result suggests that the intra-rater and inter-rater reliability of a pressure biofeedback unit was better than the other methods. The difference in distance of the anterior glide of humeral head was insignificant among all the methods. The pressure biofeedback unit method was the most reliable method, so it is proposed to be a new and reliable method to measure internal rotation range of motion.

The effect of active and passive confining pressure on compressive behavior of STCC and CFST

  • Nematzadeh, Mahdi;Fazli, Saeed
    • Advances in concrete construction
    • /
    • 제9권2호
    • /
    • pp.161-171
    • /
    • 2020
  • In this paper, an experimental study was conducted on the compressive behavior of steel tube confined concrete (STCC) and concrete-filled steel tube (CFST) columns with active and passive confinement. To create active confinement in the STCC and CFST specimens, an innovative method was used in this study, in which by applying pressure on the fresh concrete, the steel tube was laterally pretensioned and the concrete core was compressed simultaneously. Of the benefits of this technique are improving the composite column behavior, without the use of additives and without the need for vibration, and achieving high prestressing levels. To achieve lower and higher prestressing levels, short and long term pressures were applied to the specimens, respectively. Nineteen STCC and CFST specimens in three groups of passive, short-term active, and long-term active confinement were subjected to axial compression, and their mechanical properties including the compressive strength, modulus of elasticity and axial strain were evaluated. The results showed that the proposed method of prestressing the STCC columns led to a significant increase in the compressive strength (about 60%), initial modulus of elasticity (about 130%) as well as a significant reduction in the axial strain (about 45%). In the CFST columns, the prestressing led to a considerable increase in the compressive strength, a small effect on the initial and secant modulus of elasticity and an increase in the axial strain (about 55%). Moreover, increased prestressing levels negligibly affected the compressive strength of STCCs and CFSTs but slightly increased the elastic modulus of STCCs and significantly decreased that of CFSTs.