• Title/Summary/Keyword: passive pressure

Search Result 329, Processing Time 0.027 seconds

The Experimental Study on the Efficiency of Ventilation of Korean Paper (Hanji) (한지(韓紙)의 환기성능에 관한 실험적 연구)

  • 이종원;임정명
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.482-489
    • /
    • 2004
  • The purpose of this study is to reevaluate the performance of Hanji as a architectural material. Recent studies report that one of the causes of the Sick-HouseㆍSick-Building Syndrome is due to the contaminants from interior materials and the lack of ventilation. In this study, the properties of Hanji are investigated. The major focuses of this research are (1) how efficient the Hanji is for ventilation of the house and (2) whether the usage of Hanji brings required ventilation volume to the house. According to the test results, differential pressure in the air and the amount of ventilation showed linear relationship. Test results differ from various kinds of Hanji. Since houses usually have double window system, Hanji can be used to the windows system, especially for inner part of double window system. It is suggested that the combination of Hanji windows for the inner part and glass windows for outer part is very effective, and offers a solution to improvement of indoor air quality and the lack of ventilation with passive ventilation that has less energy consumption.

Effects of CEO's Demographic Characteristics on Decoupling (최고 경영자의 인구통계학적 특성이 조직 디커플링 행위에 미치는 영향)

  • Kim, Yong;Choi, Youngjun
    • Knowledge Management Research
    • /
    • v.21 no.1
    • /
    • pp.79-98
    • /
    • 2020
  • The majority of research on institutional theory suggests that the new institutional practices presented by national governments and expert groups is a legitimate demand by society, and that the organization is a passive actor that accepts it. However, individual organizations often perform so-called decoupling acts that run their organizations in their own way instead of following the way the system requires, despite the pressures of a strong institutional environment. In this study, the decoupling behavior of these organizations can be varied by the characteristics of the highest decision maker in the organization based on the upper-echelon theory(UET) even if there is no difference in pressure experienced by individual organizations, and their relationship is empirically analyzed among secondary educational institutions that are relatively strongly regulated by the government. According to the analysis of 192 high schools in Korea, the female principal, the younger the principal, and the higher the educational background, the more likely they are to engage in decoupling behavior that are different from the intent and content of government policies. Therefore, from the results of this study, meaningful theoretical and practical implications can be provided for researchers and managers in the field of knowledge management research.

A study on the inner flow fields characteristics of the Semi-active muffler (반능동형 머플러 내부의 유동장특성에 관한 연구)

  • Park Kyoung-Suk;Heo Hyung-Seok;Park Se-Jong;Son Sung-Man;Kim Dong-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.125-131
    • /
    • 2006
  • Recently air pollution has become an important issue. So, as tile number of vehicles increases, the noise pollution has become one of the most serious social issues nowadays. It is a muffler, which is one of the vehicle components. that has the hugest impact on the noise from the vehicle. And it also has a direct influence on the engine performance. So lately the research is proceeding on tile semi-active muffler which can control the back pressure variably by setting up the exhaust variable valve in the baffle to improve its internal structure. The inner parts of muffler which consist of a baffle, pipes and etc. appear to have the complicated turbulence phenomena by the pulsational wave of an unsteady state in the engine and by the structural characteristics of the inner parts. To analyze these phenomena, it is required to have an analysis of its constant quantity and quality. Therefore this study is to analyze with PIV measurement which can analyze the time and space variables, not with the point measurement method like former multi-point anemometer. It is to suggest proper design variables which need to make internal structure of the muffler improve though comparison between the passive type muffler and the semi-active muffler by fabricating a muffler which can be visualized.

ASSESSMENT OF A NEW DESIGN FOR A REACTOR CAVITY COOLING SYSTEM IN A VERY HIGH TEMPERATURE GAS-COOLED REACTOR

  • PARK GOON-CHERL;CHO YUN-JE;CHO HYOUNGKYU
    • Nuclear Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.45-60
    • /
    • 2006
  • Presently, the VHTGR (Very High Temperature Gas-cooled Reactor) is considered the most attractive candidate for a GEN-IV reactor to produce hydrogen, which will be a key resource for future energy production. A new concept for a reactor cavity cooling system (RCCS), a critical safety feature in the VHTGR, is proposed in the present study. The proposed RCCS consists of passive water pool and active air cooling systems. These are employed to overcome the poor cooling capability of the air-cooled RCCS and the complex cavity structures of the water-cooled RCCS. In order to estimate the licensibility of the proposed design, its performance and integrity were tested experimentally with a reduced-scale mock-up facility, as well as with a separate-effect test facility (SET) for the 1/4 water pool of the RCCS-SNU to examine the heat transfer and pressure drop and code capability. This paper presents the test results for SET and validation of MARS-GCR, a system code for the safety analysis of a HTGR. In addition, CFX5.7, a computational fluid dynamics code, was also used for the code-to-code benchmark of MARS-GCR. From the present experimental and numerical studies, the efficacy of MARS-GCR in application to determining the optimal design of complicated systems such as a RCCS and evaluation of their feasibility has been validated.

Development of a Barrier Embedded Chaotic Micromixer (배리어가 포함된 카오스 마이크로 믹서의 개발)

  • 김동성;이석우;권태헌;이승섭
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.1
    • /
    • pp.63-69
    • /
    • 2004
  • It is of great interest to enhance mixing performance in a microchannel in which the flow is usually characterized as a low Reynolds number (Re) so that good mixing is quite difficult to be achieved in this laminar flow regime. In this regard, we present a new chaotic passive micromixer, named Barrier Embedded Micromixer (BEM), of which the mixing mechanism is based on chaotic flows. In BEM, chaotic flow is induced by periodic perturbation of the velocity field due to periodically inserted barriers along the channel wall while a helical type of flow is obtained by slanted grooves on the bottom surface of the channel in the pressure driven flow. To experimentally compare the mixing performance, a T-microchannel and a microchannel with only slanted grooves were also fabricated. All microchannels were made of PDMS (Polydimethylsiloxane) from SU-8 masters that were fabricated by conventional photolithography. Mixing performance was experimentally characterized with respect to an average mixing intensity by means of color change of phenolphthalein as pH indicator. It was found that mixing efficiency decreases as Re increases for all three micromixers. Experimental results obviously indicate that BEM has better mixing performance than the other two. Chaotic mixing mechanism, suggested in this study, can be easily applied to integrated microfluidic systems , such as Micro-Total-Analysis-System, Lab-on-a-chip and so on.

A Study On The Reinforcing Effect Multibell Anchor Applied To The Cut Slope (비탈면에 적용된 다구근 앵커의 보강효과 연구)

  • Cha, Kyung-Sub;Kim, Seon-Ju;Kim, Tae-Hoon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1286-1293
    • /
    • 2010
  • The ground anchor used in domestic area, which resists by adhesion between anchor body and the ground to the external force, seems not to be adequate for soft ground and urban area where the boundary between structures is close because the ground is disturbed and lost its strength during boring. In order to overcome such a shortcoming an expanded anchor system has been developed. The ground expansion is accomplished by means of Pulse Discharge Technology. In this technology, a high voltage of electricity is stored and discharged in milliseconds which induces high pressure acting on the ground. By making a couple of bulbs, a passive resistance as well as shaft resistance are mobilized, and therefore a higher pullout resistance comparing existing ground anchors is developed.In this study, a couple of full scale tests were conducted in order to figure out how much the resistance of an expanded anchor increases comparing to the straight. As a result, it was found that a remarkable increase in ultimate pullout capacity is observed for the soft ground and as the number of bulb increases. In addtion, as a result of applying to a cut slope reinforcement, it appeared that the length of fixed zone of anchor can be reduced effectively.

  • PDF

Estrogen Attenuates the Pressor Response Mediated by the Group III Mechanoreflex (폐경전후 여성의 Group III 기계적 수용기 자극 시 운동승압반사의 비교)

  • Park, Seung-Ae;Kim, Jong-Kyung
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.2
    • /
    • pp.191-196
    • /
    • 2011
  • Purpose: We investigated the effects of group III mechanoreceptors to cardiovascular responses in both pre-menopausal woman and post-menopausal woman during passive ankle dorsiflexion (PAD). Methods: Twenty healthy volunteers (10 post-menopausal women and 10 pre-menopausal women) were recruited for this study. Stroke volume (SV), heart rate (HR), cardiac output (CO), and total vascular conductances (TVC) were measured continuously throughout the experiment. To stimulate the group III mechanoreceptors, PAD was performed for one minute. Results: The results showed that mean arterial pressure (MAP) mediated by the mechanoreflex activation was significantly increased in both groups. However, this pressor response was significantly higher in post-menopausal women. This reflex significantly increased both SV and CO in pre-menopausal women, while there were no differences in post-menopausal women. There was no difference in HR in either group. The mechanoreflex significantly decreased TVC in post-menopausal woman, while there was no difference in pre-menopausal woman. Conclusion: The results indicate that the excessive pressor response mediated by the mechanoreflex occurs due to overactivity of group III mechanorecptors and the mechanism is produced mainly via peripheral vasoconstriction in post-menopausal women.

A Study on the Impulse Waves Discharged from the Exit of the Convergent/Divergent Pipes (축소/확대관 출구로부터 방출되는 펄스파에 관한 연구)

  • Lee, D.H.;Ju, K.M.;Kim, H.S.;Kim, H.D.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.640-645
    • /
    • 2001
  • The present study is to investigate the characteristics of the impulse waves discharged from the exit of the convergent and divergent pipes. An experiment is carried out using a shock tube with an open end and is compared to the computation of the axisymmetric, compressible, unsteady Euler equations, which are solved by the second-order total variation diminishing(TVD) scheme. For the computational work, some initial compression waves are assumed inside the pipe so that those are identical to the experimental ones of the shock tube. The results show that the peak pressures of the impulse waves discharged from the exit of convergent and divergent pipes decrease with an increase in the wavelength of the initial compression wave. All of the impulse waves have a strong directivity toward the pipe axis, regardless of the exit type of the pipe employed. The impulse waves discharged from the divergent pipe are stronger than those from the straight pipe, while the impulse waves of the convergent pipe are weaker than those from the straight pipe. It is believed that the convergent pipe can playa role of a passive control to reduce the peak pressure of the impulse wave. The present computations represent the experimented impulse waves with a good accuracy.

  • PDF

VPI Varnishing Technology Effects on Frequency Characteristics of an Air Core Inductor Used in LISN Circuit Application

  • Kanzi, Khalil;Kanzi, Majid;Nafissi, Hamidreza
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.57-64
    • /
    • 2013
  • The functional characteristic of LISN circuit, which is used for measurements of conductive noise in mains power line, is basically related to frequency characteristics of passive elements like inductors used in the circuit as well as the frequency response of inductors is highly related to the resins used in the varnishing process. The significant problem in determination of an inductor's frequency characteristic is the intrinsic resistance, inductance and parasitic capacitance. In this triplet, the parasitic capacitance is the major limiting factor of inductor's frequency range. This capacitance depends on inductor design parameters and materials filling the spaces of coil like resin and its coherency after curing process. In this paper, two similar inductors were designed and built. The first inductor was not varnished while the second one was varnished with VPI technology. VPI, or Vacuum, Pressure, Impregnation technology is one of the most reliable methods performing good insulating conditions for electrical circuits and windings based on resins. The measured results show that implying varnishing technology does not significantly affect the frequency response. However, due to mechanical solidity aspects and improved environmental protection, it is better to varnish the inductors.

Effect of the Sprue Design on the Fitness of Implant Prosthesis (주입선의 설계가 임플란트 보철물의 적합도에 미치는 영향)

  • Hwang, Sung-Taek;Ahn, Jae-Seok;Shin, Sang-Wan
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.57-63
    • /
    • 2008
  • Statement of problem: Conventional techniques for implant framework fabrication produce significant error that is inconsistent with passive-fit requirement for osseointegrated implants. One of the etiologic factors which cause the errors is a sprue which may deform the framework during solidification and contraction. Purpose: This study was aimed to evaluate objectively effect of the sprue design on the accuracy of fit of implant prosthesis. Materials and method: Three different designs were considered relative to effect of casting accuracy. The first design had straight sprues and a button of excess alloy at the non-casting end of the sprues. The second was runner bar design(with the button). The last was straight sprues design(without the button). Gold cylinder and laboratory analogue had been used to diminish variables affecting to casting accuracy. Gold alloy and pressure-vacuum casting machine had been used. Marginal gap had been measured by SEM. One-way ANOVA and Duncan test had been used for statistical analysis. Results: The first design showed $79.87{\pm}13.95{\mu}m$ marginal gap. The second and third were $40.17{\pm}15.8{\mu}m$ and $35.17{\pm}9.95{\mu}m$ respectively. Conclusion: Straight sprues without button and runner bar designs were more accurate than straight sprues with button design(P<.05).

  • PDF