• 제목/요약/키워드: passive pressure

검색결과 330건 처리시간 0.023초

연료전지 자동차용 막 가습기 개발 (Development of Membrane Humidifier for FCEV)

  • 김경주;이무석;윤준기;신용철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.177-179
    • /
    • 2007
  • An object of the present study is to provide a hollow fiber membrane humidifier capable of improving the humidification efficiency while lowering the pressure loss, and is suitably usable for PEMFC(Polymer Electrolyte Membrane Fuel Cell). The performance of PEMFC is decisively dependent on the humidity of the electrolyte membrane(fluorinated membrane) and a humidifier plays an important role in moisturizing electrolyte membrane. Especially, this humidifier is a passive type(power-free) item and is volumetrically optimized. In this research, we propose the substitutes for the expensive fluorinated humidifier materials and the optimum dry-jet wet spinning conditions of hollow fiber membrane. In addition to that, This study will present an performance of an humidifier and compare computational results with the experimental data.

  • PDF

연약점토 지반에 있는 STONE COLUMN의 지지력 산정 (Bearing capacity analysis of stone column in soft clay soils)

  • 이윤주
    • 한국해양공학회지
    • /
    • 제10권4호
    • /
    • pp.141-148
    • /
    • 1996
  • Use of stone column for deep ground treatment in soft clay soils is an effective method. The stone column significantly increases load carrying capacity of the soft clay soil. A analysis method for bearing capacity of stone column in soft clay soil is developed. The capacity made by developed method are compared wity observed values from field load test and a reasonable correlation is noted.

  • PDF

열공압형 마이크로 펌프의 제작에 관한 연구 (A Study on the Fabrication of a Thremopneumatic micropump)

  • 김영수;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1960-1962
    • /
    • 1996
  • A thermopneumatic micropump with two micronozzles has been fabricated and tested. The actuator consists of a p+ diaphragm and a pyrex glass on which a microheater is deposited. Two micronozzles are fabricated on either side of a single silicon wafer and behave as a dynamic passive valves. The actuator and the micronozzle are assembled to make a micropump. The center deflection of the actuator diaphragm to step voltage input has been measured. The dynamic test hag been performed by measuring the center deflection of the diaphragm under various input voltages and duty ratios. Also dynamic pumping test is performed. The measured built-up pressure between inlet and outlet of the micropump is 80 Pa for the actuation at 20V, 10 Hz.

  • PDF

이차원 운송체 모형에서 후류 교란자를 이용한 항력 감소 (Reduction of Drag on a Two-Dimensional Model Vehicle Using Wake Disrupter)

  • 이동건;최진;전우평;김정래;한성현;최해천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.652-657
    • /
    • 2003
  • A wind-tunnel experiment is carried out to examine the applicability of a new passive device, wake disrupter, to flow over a model vehicle for drag reduction. The wake disrupter is a small-size rectangular body attached to a part of the trailing edge of the model vehicle, designed to perturb an essentially two-dimensional nature of wake. A pair of wake disrupter is mounted on the mid-span at the upper and lower trailing edges. From a parametric study about the size of wake disrupter, it is found that the optimum disrupter increases the base pressure by about 20%. Large eddy simulation is also conducted to confirm the experimental result, and shows that the wake is indeed disrupted by the present device.

  • PDF

제품책임(製品責任)을 위한 품질비용(品質費用) 최적화(最適化)에 관한 연구(硏究) (A Study on the Optimization of Quality Cost for Product Liability)

  • 고복수;조남호
    • 품질경영학회지
    • /
    • 제18권1호
    • /
    • pp.116-128
    • /
    • 1990
  • Consumer's demand level for products and goods selection power is considerably improved. The pressure of loss compensation is also being accelerated by products which bring damage on property. The producer prevents the loss from causing poor products and considering the quality cost allotment in these circumstances. That is to say, producer should be concerned with the strategy of product liability prevention instead of passive defence policy. This paper intends to estabilish the optimum quality cost in considering product liability, and present the correlation of quality cost elements and multiple regression analysis. It can utilized in qualitycost and budget planning.

  • PDF

연속 가변형 충격흡수기의 감쇠성능 해석 (Damping performance Analysis for an Electronically Contralled Shock Absorber)

  • 박재우;이동락;백운경
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.192-201
    • /
    • 2001
  • Analyzing internal structure, flow rate and dynamic behavior characteristics of electronically controlled shock absorber, damping performance limit is identified to comprise the two reciprocal characteristics of ride comfort and handling safety. Regardless of its lower performance than the active suspension control system, the semi-active suspension control system has been taking interest because of its absolutely higher performance than passive suspension system. Since the pervious studies have been concentrated mostly on analytic aspect and survey on the internal structure of the shock absorber remain insufficient, the main discourse of this paper is focused on analyzing the nonlinear shock absorber which varies the damping force of semi-active suspension system and the dynamic characteristics of the solenoid valve, a sort of pressure valve, and proposing the design factors of importance.

  • PDF

Assessment of RELAPS/MOD3 with Condensation Experiment for Pure Steam Condensation in a Vercal Tube

  • Kim, Sang-Jae;No, Hee-Cheon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.559-564
    • /
    • 1998
  • The film condensation models in RELAP5/MOD3.1 and RELAP5/WOD3.2 are assessed with the data experiment performed in the scaled down condensation experimental facility with a single vertical tube inner diameter 46 mm in the range of pressure 0.1∼7.5 Mpa for the PSCS(Passive Secondary Condenser System) Both MOD3.1 and MOD3.2 don't shows any reliable predictions the experimental data The RELAP5/MOD3.1 overpredicts the heat transfer coefficients experiment, whereas the RELAP5/MOD3.2 underpredicts those data it is recommended that the film condonation model in RELAP5/MOD3.2 should be modified to hue a larger heat transfer coefficient than those the present model to give the reliable predictions.

  • PDF

Effects of the Width and Location of a Flow Disturbing Plate on Pool Boiling Heat Transfer on a Vertical Tube

  • Kang Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.191-205
    • /
    • 2003
  • Effects of the width and location of a flow disturbing circular plate, installed at a vertical tube surface, on nucleate pool boiling heat transfer of water at atmospheric pressure have been investigated experimentally. Through the tests, changes in the degree of intensity of liquid agitation have been analyzed. The plate changes the fluid flow around the tube as well as heat transfer coefficients on the tube surface. It is identified that the plate width changes the rate of the circulating flow whereas its location changes the growth of the active agitating flow. Moreover, the flow chugging was observed at the downside of the plate.

실물인장실험시 변형률계를 이용한 전주에 작용하는 응력분석 (Stress Analysis Acting on Electric Pole using Strain Gauge from Full Scale Pull-Out Test)

  • 안태봉
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.49-55
    • /
    • 2010
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find stresses acting on concrete electric poles. The stresses of concrete poles are relaxed at 600~700[kg] of tensile load, and stresses are concentrated at top of pole, and spread to lower part of pole. In the concrete pole collapse test, tensile load at failure was approximately 1,400[kg], which is twice of design load. As passive zone in the soil increases, the stresses acting on concrete pole are concentrated at lower part of pole based on moment arm earth pressure distribution.

A 12-year long-term study on the external deformation behavior of Geosynthetic Reinforced Soil (GRS) walls

  • Won, Myoung-Soo;Lee, O-Hyeon;Kim, You-Seong;Choi, Se-Kyung
    • Geomechanics and Engineering
    • /
    • 제10권5호
    • /
    • pp.565-575
    • /
    • 2016
  • Geosynthetics reinforced soil (GRS) walls constructed on weak grounds may change in both the horizontal earth pressure and deformation on wall facing. However, only few studies were done in the literature to measure and analyze the horizontal external deformation behavior of GRS walls constructed on soft grounds for a long period of time. The present study describes the external deformation behavior of GRS walls observed for 12-year long-term performance. The horizontal deformation of the geosynthetics-wrapped-facing GRS walls shows a passive behavior along one third of the wall height, from top going downwards, and active behavior for the rest of the wall height. Even if the geogrid and nonwoven geotextiles are exposed directly to sunlight and rainfalls in a span of 12 years, they have functioned well as wall facing. Therefore, the geosynthetic reinforcement material is strong enough to resist ultraviolet rays.