• Title/Summary/Keyword: passive imaging

Search Result 80, Processing Time 0.027 seconds

Development of Passive Millimeter-wave Security Screening System (수동 밀리미터파 보안 검색 시스템 개발)

  • Yoon, Jin-Seob;Jung, Kyung Kwon;Chae, Yeon-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.138-143
    • /
    • 2016
  • The designed and fabricated millimeter-wave security screening system receives radiation energy from an object and a human body. The imaging system consist of sixteen array antennas, sixteen four-stage LNAs, sixteen detectors, an infrared camera, a CCD camera, reflector, and a focusing lens. This system requires high sensitivity and wide bandwidth to detect the input thermal noise. The LNA module of the system has been measured to have 65.8 dB in average linear gain and 82 GHz~102 GHz in bandwidth to enhance the sensitivity for thermal noise, and to receive it over a wide bandwidth. The detector is used for direct current (DC) output translation of millimeter-wave signals with a zero bias Schottky diode. The lens and front-end of the millimeter-wave sensor are important in the system to detect the input thermal noise signal. The frequency range in the receiving sensitivity of the detectors was 350 to 400 mV/mW at 0 dBm (1 mW) input power. The developed W-band imaging system is effective for detecting and identifying concealed objects such as metal or plastic.

Development of New Methods for Position Estimation of Underground Acoustic Source Using a Passive SONAR System

  • Jarng, Soon-Suck;Lee, Je-Hyeong;Ahn, Heung-Gu
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.1
    • /
    • pp.69-75
    • /
    • 2000
  • The aim of the work described in this paper is to develop a complex underground acoustic system which detects and localizes the origin of an underground hammering sound using an array of hydrophones located about 100m underground. Three different methods for the sound localization will be presented, a time-delay method, a power-attenuation method and a hybrid method. In the time-delay method, the cross correlation of the signals received from the array of sensors is used to calculate the time delays between those signals. In the power-attenuation method, the powers of the received signals provide a measure of the distances of the source from the sensors. In the hybrid method, both informations of time-delays and power-ratios are coupled together to produce better performance of position estimation. A new acoustic imaging technique has been developed for improving the hybrid method. This new acoustic imaging method shows the multi-dimensional distribution of the normalized cost function, so as to indicate the trend of the minimizing direction toward the source location. For each method the sound localization is carried out in three dimensions underground. The distance between the true and estimated origins of the source is 28m for a search area of radius 250m.

  • PDF

Position estimation of underground acoustic source origin using a passive SONAR system (수동형 SONAR 시스템을 사용한 지하 진원지의 추정)

  • Jarng Soon Suck;Lee Je Hyeong;Ahn Heung Gu;Choi Heun Ho
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.103-108
    • /
    • 1999
  • The aim of the work described in this paper is to develop a complex underground acoustic system which detects and localizes the origin of an underground hammering sound using an array of hydrophones located about loom underground. Three different methods for the sound localization will be presented, a time-delay method, a power-attenuation method and a hybrid method. In the time-delay method, the cross correlation of the signals received from the array of sensors is used to calculate the time delays between those signals. In the power-attenuation method, the powers of the received signals provide a measure of the distances of the source from the sensors. In the hybrid method, both informations of time-delays and power-ratios are coupled together to produce better performance of position estimation. A new acoustic imaging technique has been developed for improving the hybrid method. This new acoustic imaging method shows the multi-dimensional distribution of the normalized cost function, so as to indicate the trend of the minimizing direction toward the source location. For each method the sound localization is carried out in three dimensions underground. The distance between the true and estimated origins of the source is 28m for a search area of radius 250m.

  • PDF

Design and Analysis of an Optical System for an Uncooled Thermal-imaging Camera Using a Hybrid Lens (Hybrid 렌즈를 이용한 비냉각 열상장비 광학계 설계 및 분석)

  • Ok, Chang-Min;Kong, Hyun-Bae;Park, Hyun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.5
    • /
    • pp.241-249
    • /
    • 2017
  • This paper presents the design and evaluation of the optical system for an uncooled thermal-imaging camera. The operating wavelength range of this system is from $7.7{\mu}m$ to $12.8{\mu}m$. Through optimization, we have obtained a LWIR (Long Wave Infrared) optical system with a focal length of 5.44 mm, which consists of four aspheric surfaces and two diffractive surfaces. The f-number of the optical system is F/1.2, and its field of view is $90^{\circ}{\times}67.5^{\circ}$. The hybrid lens was used to balance the higher-order aberrations, and its diffraction properties were evaluated by scalar diffraction theory. We calculated the polychromatic integrated diffraction efficiency, and the MTF drop generated by background noise. We have evaluated the thermal compensation of a LWIR fixed optical system, which is optically passively athermalized to maintain MTF performance in the focal depth. In conclusion, these design results are useful for an uncooled thermal-imaging camera.

A STUDY ON THE DETERMINATION OF THE INSTANTANEOUS FIELD OF VIEW FOR I-M HIGH RESOLUTION SATELLITE IMAGE

  • Seo Doo-Chun;Park Su-Young;Lee Dong-Han;Lee Sun-Gu;Song Jeong Heon;Lim Hyo-Suk
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.649-652
    • /
    • 2005
  • In this paper we present a detail approach of the determination of IFOV (Instantaneous Field of View) of high-resolution (l m) panchromatic satellite image over test site. IFOV is the representative measurements as the determination of the spatial resolution in remote sensed imaging system. It can be defined as some area on the ground with the particular altitude when the satellite acquires the image at any given time. Especially, spatial resolution of passive sensors primarily depends on their IFOV. The determination of IFOV goes through simple steps of procedure as followings: Firstly, the GSD (Ground Sample Distance) should be computed at each point on the geometrically corrected image. Then, The GSD is converted into the IFOV. So we are going to explain our test procedures and results.

  • PDF

New Guidance Filter Structure for Homing Missiles with Strapdown IIR Seeker

  • Kim, Tae-Hun;Kim, Jong-Han;Kim, Philsung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.4
    • /
    • pp.757-766
    • /
    • 2017
  • For implementing the proportional navigation guidance law on passive homing missiles equipped with strapdown imaging infrared seekers, the line-of-sight angles and rates with respect to the inertial frame should be estimated by carefully handling the parasitic instability effect due to the seeker's latency. By introducing a new state vector representation along with the Pade approximation for compensating the time-delay of the seeker, this paper proposes a new guidance filter structure, stochastic dynamic models and measurement equations, in three-dimensional homing problem. Then, it derives the line-of-sight angle and rate estimator in general two-dimensional engagement by applying the extended Kalman filter to the proposed structure. The estimation performance and the characteristics of the proposed filter were evaluated via a series of numerical experiments.

Microwave Radiometer for Space Science and DREAM Mission of STSAT-2

  • Kim, Y.H.
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.31.4-32
    • /
    • 2008
  • The microwave instruments are used many areas of the space remote sensing and space science applications. The imaging radar of synthetic aperture radar (SAR) is well known microwave radar sensor for earth surface and ocean research. Unlike radar, microwave radiometer is passive instrument and it measures the emission energy of target, i.e. brightness temperature BT, from earth surface and atmosphere. From measured BT, the geophysical data like cloud liquid water, water vapor, sea surface temperature, surface permittivity can be retrieved. In this paper, the radiometer characteristics, system configuration and principle of BT measurement are described. Also the radiometer instruments TRMM, GPM, SMOS for earth climate, and ocean salinity research are introduce. As first korean microwave payload on STSAT-2, the DREAM (Dual-channels Radiometer for Earth and Atmosphere Monitoring) is described the mission, system configuration and operation plan for life time of two years. The main issues of DREAM unlike other spaceborne radiometers, will be addressed. The calibration is the one of main issues of DREAM mission and how it contribute on the space borne radiometer. In conclusion, the radiometer instrument to space science application will be considered.

  • PDF

Image Forgery Detection Using Gabor Filter (가보 필터를 이용한 이미지 위조 검출 기법)

  • NININAHAZWE, Sheilha;Rhee, Kyung-Hyune
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.11a
    • /
    • pp.520-522
    • /
    • 2014
  • Due to the availability of easy-to-use and powerful image editing tools, the authentication of digital images cannot be taken for granted and it gives rise to non-intrusive forgery detection problem because all imaging devices do not embed watermark. Forgery detection plays an important role in this case. In this paper, an effective framework for passive-blind method for copy-move image forgery detection is proposed, based on Gabor filter which is robust to illumination, rotation invariant, robust to scale. For the detection, the suspicious image is selected and Gabor wavelet is applied from whole scale space and whole direction space. We will extract the mean and the standard deviation as the texture features and feature vectors. Finally, a distance is calculated between two textures feature vectors to determine the forgery, and the decision will be made based on that result.

Clinical Results of Distal Femoral Osteotomy for Treatment of Grade 4 Medial Patella Luxation with Concurrent Distal Femoral Varus in Small Breeds Dogs: 13 Cases

  • Roh, Yoon-Ho;Jung, Jin-Ho;Lee, Je-Hun;Jeong, Jae-Min;Jeong, Seong Mok;Lee, HaeBeom
    • Journal of Veterinary Clinics
    • /
    • v.37 no.3
    • /
    • pp.135-140
    • /
    • 2020
  • The purpose of this study was to determine the outcome of distal femoral osteotomy for distal femoral varus and medial patellar luxation (MPL) grade 4 in small-breed dogs. Radiographs and medical records were reviewed to collect data and plan the surgery in small-breed dogs with MPL grade 4. Computed tomography (CT) imaging was also performed in cases of severe bone deformities. Signalment, weight, medial patellar luxation and lameness grade, radiographic bone union, complications, pre- and postoperative femoral varus angle, passive range of motion, static weight bearing distribution and visual analogue scale scores were recorded. Thirteen corrective distal femoral osteotomies were performed with ancillary and additional procedures in 9 dogs; 4 dogs had staged bilateral procedures; and four stifles were suspected to have partial or complete rupture of the cranial cruciate ligament. One stifle underwent patellar groove replacement. The mean ± SD pre- and postoperative femoral varus angles were 109.15°± 3.71° and 96.30°± 2.97°, respectively. Significant improvements in passive range of motion, thigh circumference and visual analogue scale (VAS) scores were observed. There was no reluxation of the patella. This study suggests that distal femoral osteotomy with traditional and additional procedures provided satisfactory outcomes in patient healing and functional recovery in small-breed dogs with excessive femoral varus angles.

Design of W-Band Diode Detector (W-Band 다이오드 검출기 설계)

  • Choi, Ji-Hoon;Cho, Young-Ho;Yun, Sang-Won;Rhee, Jin-Koo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.3
    • /
    • pp.278-284
    • /
    • 2010
  • In this paper, a millimeter-wave detector using zero-bias schottky diode is designed and fabricated at W-band. It consists of LNA(Low Noise Amplifier) and detector module to improve sensitivity. LNA case with a highly stop-band characteristic is designed to prevent the oscillation by LNA MMIC chip. Diode detector of planar structure is fabricated for the easy connection with LNA module and zero bias Schottky diode is utilized. In practice, the fabricated diode detector have shown the detection voltage of 20~500 mV to the RF input power of -45~-20 dBm. The proposed W-band detector can be applicable to the passive millimeter image system.