• Title/Summary/Keyword: passive hemagglutination (PHA) titer

Search Result 5, Processing Time 0.019 seconds

A Study on the Validity of Passive Hemagglutination (PHA) Test for HBsAb (B형 간염 바이러스 표면 항체 검출을 위한 Passive Hemagglutination (PHA)방법의 정확도에 관한 연구)

  • Park, Byung-Joo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.20 no.1 s.21
    • /
    • pp.114-119
    • /
    • 1987
  • The author investigated the effect of some variables such as age, sex and the experience of past vaccination on the validity of PHA. The changing pattern of the validity with the change of PHA diagnostic criteria, and the relationship between PHA test result and RIA Ratio Unit were also studied. The results obtained were as follow; 1) No statistically significant difference was found in sensitivity, specificity and negative predictability by sex, but positive predictability was significantly higher in male than that in female. 2) Positive predictability was shown to become higher with the increase of age and nagative predictability was found to be significally different among age groups, but no statistically significant difference was found in sensitivity and specificity by age group. 3) Significantly low specificity and high positive predictability were found in past vaccined group, but no statistically significant difference was found in sensitivity and negative predictability between past vaccined group and non-vaccined group. 4) False negative cases by PHA were found to be the weak positive reactors by RIA and false positive rate of PHA was as high as 46.3 per cent. 5) Sensitivity and specificity of PHA at the diagnostic criteria of HBsAb titer 1:2 were 98.4% and 53.8% respectively, but after increasing the HBsAb titer to 1:64 as the diagnostic criteria the results were 60.0% and 95.6% respectively.

  • PDF

Antigenicity Studies of the Aqueous Extract of Red Ginseng in Guinea Pigs

  • Lee, Jong-Wha;Rhee, Man-Hee;Park, Ki-Hyun
    • Archives of Pharmacal Research
    • /
    • v.17 no.3
    • /
    • pp.154-160
    • /
    • 1994
  • The antigenicity of the aqueous extract of red ginseng (ARG) was evaluated using the following assay procedures : 1. active systemic anaphylaxis (ASA) in guinea pigs, 2 active cutaneous anaphylaxis (ACA) in guinea pigs, 3 passive cutaneous anaphylaxis (PCA) in guinea pigs, 2.active cutaneous anaphylaxis (ACA) in guinea pigs, 3. passive cutanepous anaphylaxis (PCA) in guina pigs with serum for guina pigs sensitized with ARG and 4. passive hemagglutination (PHA) with serum from guinea pigs sensitized with ARG. 1. ASA : No anaphylaxis reaction was observed in any of the sensitized guinea pigs by elictitation with ARG. 2. ACA : No skin reaction was observed in sensitized guinea pigs after intrademal injection of ARG. 3. PCA in guinea pigs : PCA titer of sera from all the sensitized animals was less than 10 in eliciation with ARG. 4. PHA reaction : When eythrocytes coated with challenge antigen were added to sensitized sera, the hemagglutination titer was less than 1. These results suggest that ARG has no antigenicity under the conditions used. And the dose levels of ARG employed in the present experiment were confirmed not to suppress immune reactions.

  • PDF

Immune response and efficacy of pigeon pox virus vaccine and fowl pox virus vaccine in chickens

  • Shil, Niraj Kanti;Rahman, Md Siddique;Hossain, M.T.;Islam, M.T.;Rahman, M.M.;Islam, K.B.M. Saiful;Cha, Se-Yeoun;Jang, Hyung-Kwan;Song, Hee-Jong
    • Korean Journal of Veterinary Service
    • /
    • v.30 no.4
    • /
    • pp.497-503
    • /
    • 2007
  • The humoral immune response of chicken vaccinated with fowl and pigeon pox virus vaccines was determined with the protective potentiality of the two vaccines in field condition of Bangladesh. Different aged Fayoumi chicks were subjected for the study. To assess the relationship with better immune response among experimental groups, the average percentage of 'take reaction' was examined and recorded to 97.77% in group A, 93.33% in group B and 100.0% in group C. The level of immune status induced by different vaccinated group was measured by passive hemagglutination (PHA) microplate test method. The mean PHA titer levels after primary vaccination were $33.06{\pm}14.13$ in group A, $32.0{\pm}14.81$ in group B, and $33.0{\pm}13.66$ in group C. Following booster vaccination, the mean PHA titer levels in prior of challenge were increased to $55.46{\pm}14.64$ in groups A and C, and $46.93{\pm}16.52$ in group B. The recorded PHA titer levels of each group at two weeks after challenge were significantly increased to $106.66{\pm}31.22$, $93.86{\pm}33.04$ and $110.93{\pm}29.29$, respectively. The PHA titer levels after vaccination and challenge were significantly increased compared to pre-vaccination titer levels (P<0.01). Although the PHA titer levels among three groups administrated different vaccine combinations in prior of challenge were significantly varied (P<0.01), it was observed that all of the vaccinated chicks were highly protected against challenge infection.

Comparison of Methods for the Detection of Anti-HBs for Hepatitis B Vaccination Program in Korea (보건예방사업을 위한 B형간염 표면항체 검사방법 비교)

  • Lee, Jeong-Nyeo;Urm, Sang-Hwa;Lee, Jong-Tae;Chun, Jin-Ho;Sohn, Hae-Sook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.2
    • /
    • pp.226-230
    • /
    • 2000
  • Objectives : The purpose of this study was to suggest a proper method for the detection of heaptitis B surface antibody(anti-HBs) in a screening program for hepatitis B vaccination. Methods : Sensivitity, specificity and predictive values were compared between Immunochromatographic assay (ICA) and passive hemagglutination(PHA) in 978 subjects(565 males, 413 females, 19-78 years ranging in age, mean 46.5 years old). EIA was used as a standard method for the detection of HBsAb. Results : Sensitivity in the detection of anti-HBs of PHA and ICA was 88.7%, and 94.9%, specificity was 94.3% and 96.6%, negative predictive value was 96.5%, and 98.0%, and positive predictive value was 82.3%, and 91.3%,, respectively. False negative rate(11.3%) of PHA was higher than that(5.1%) of ICA. The higher the titer of anti-HBs in EIA was, the lower the false negative rate was. There was no false negative result in the cases with $101mIU/{\beta}c$ or more in EIA Conclusion : We suggest that ICA should be the choice of screening method in the detection of anti-HBs in Hepatitis B vaccination program.

  • PDF

Antigenicity of CFC-101(Pseudomonas vaccine) in Guinea Pigs and Mice (기니픽과 마우스에서 CFC-101(녹농균 백신)의 항원성시험)

  • 백남진;김달현;이동억;선우연;한형미;정승태;김필선;김현수
    • Biomolecules & Therapeutics
    • /
    • v.2 no.4
    • /
    • pp.331-335
    • /
    • 1994
  • As a part of the safety evaluation of Pseudomonas vaccine(CFC-101), antigenicity tests were carried out in guinea pigs and mice. In active systemic anaphylaxis(ASA) test, guinea pigs showed no sign or only moderate sign(1/5) when sensitized and challenged with up to 200 $\mu\textrm{g}$/kg. In homologous passive cutaneous anaphylaxis(PCA) test using guinea pigs, inoculation of CFC-101 alone did not produce CFC-101-specific antibody. When inoculated with 200 $\mu\textrm{g}$/kg plus adjuvant, challenge of 200 $\mu\textrm{g}$/kg produced PCA titer of 32(5/5) but challenge of 20 $\mu\textrm{g}$/kg did not produce CFC-101-specific antibody. In heterologous PCA test using mice, CFC-101-specific antibody was not detected when sensitized with CFC-101 alone. Some animals(3/12) showed positive PCA response when inoculated with 200 $\mu\textrm{g}$/kg plus alum. In passive hemagglutination (PHA) test, although no antibody was detected at 20 $\mu\textrm{g}$/kg, inoculation of 200 $\mu\textrm{g}$/kg alone or with alum produced positive response in all animals. This result has already been predicted because CFC-101 is a vaccine developed for the purpose of immunization. From the above results, it can be concluded that there is no adverse antigenic potential up to 10 times clinical dose of 200 $\mu\textrm{g}$/kg.

  • PDF