• 제목/요약/키워드: passive design

검색결과 1,387건 처리시간 0.029초

The concept of the innovative power reactor

  • Lee, Sang Won;Heo, Sun;Ha, Hui Un;Kim, Han Gon
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1431-1441
    • /
    • 2017
  • The Fukushima accident reveals the vulnerability of existing active nuclear power plant (NPP) design against prolonged loss of external electricity events. The passive safety system is considered an attractive alternative to cope with this kind of disaster. Also, the passive safety system enhances both the safety and the economics of NPPs. The adoption of a passive safety system reduces the number of active components and can minimize the construction cost of NPPs. In this paper, reflecting on the experience during the development of the APR+ design in Korea, we propose the concept of an innovative Power Reactor (iPower), which is a kind of passive NPP, to enhance safety in a revolutionary manner. The ultimate goal of iPower is to confirm the feasibility of practically eliminating radioactive material release to the environment in all accident conditions. The representative safety grade passive system includes a passive emergency core cooling system, a passive containment cooling system, and a passive auxiliary feedwater system. Preliminary analysis results show that these concepts are feasible with respect to preventing and/or mitigating the consequences of design base accidents and severe accidents.

Passive 트랜스폰더의 RF-DC 변환회로에 대한 설계 및 분석 (The Design and Analysis of RF-DC conversion circuit in the Passive Tranponder)

  • 진인수;김종범;양경록;김양모
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.757-760
    • /
    • 1999
  • Depending upon the existence of the battery, transponder is divided into active and passive transponder. The passive transponder operates without battery and so has no limitation in its operating range and life time. But it needs the RF-DC conversion circuit. In this paper, the analysis and design of the RF-DC conversion circuit in passive transponder operated in high frequency is presented and is confirmed by simulation and experiment.

  • PDF

패시브 디자인을 적용한 ICF공법 주택의 난방에너지 성능 분석 (An Analysis of Heating Energy Performance in Housings of ICF Method with Passive Design Applied)

  • 김준희;이태구
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.33-40
    • /
    • 2013
  • The world population is consuming more than 1/3 of the total energy for heating housings. Particularly in our country, 21% of the consumption energy is occupied by building section. Therefore, it is necessary to increase the energy efficiency in buildings, thus promoting a comfortable residential environment while minimizing energy consumption. Accordingly, this study presents considerations for implementing high-insulated and airtight passive houses. This study selected four houses with passive house design applied, performed building energy performance through PHPP2007, a German passive house design simulation program, and compared the building-specific heat loss and heat gain. As a result, the most vulnerable part to heat loss was turned out to be a window and the heat loss was caused by outer wall, roof, and ventilation. Accordingly, for the implementation of passive house, it is necessary to make a careful plan and airtight construction that are complementary to various parts through the energy performance analysis started from the design phase.

Robust passive damper design for building structures under uncertain structural parameter environments

  • Fujita, Kohei;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제3권6호
    • /
    • pp.805-820
    • /
    • 2012
  • An enhanced and efficient methodology is proposed for evaluating the robustness of an uncertain structure with passive dampers. Although the structural performance for seismic loads is an important design criterion in earthquake-prone countries, the structural parameters such as storey stiffnesses and damping coefficients of passive dampers are uncertain due to various factors or sources, e.g. initial manufacturing errors, material deterioration, temperature dependence. The concept of robust building design under such uncertain structural-parameter environment may be one of the most challenging issues to be tackled recently. By applying the proposed method of interval analysis and robustness evaluation for predicting the response variability accurately, the robustness of a passively controlled structure can be evaluated efficiently in terms of the so-called robustness function. An application is presented of the robustness function to the design and evaluation of passive damper systems.

Design of Passive Treatment Systems for Mine Drainage Waters

  • Jeen, Sung-Wook
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권2호
    • /
    • pp.1-9
    • /
    • 2017
  • Passive treatment systems are commonly used for remediation of mine drainage waters because they do not require continuous chemical inputs and operation. In this study, the selection and design criteria for such systems were evaluated, particularly the two most commonly used ones, i.e., permeable reactive barriers (PRBs) and vertical flow biological reactors (VFBRs). PRBs and VFBRs are operated on the same principles in terms of biochemical reaction mechanisms, whereas differences relate to configuration, engineering, and water management. In this study, each of these systems were described with respect to key design variables, such as metal removal mechanisms and removal rates, effectiveness and longevity, general design and construction, flow capacity, and cost. The information provided from this study could be used as a design guideline when a passive treatment option is considered for potential remediation of a mine site.

비주거용 건물의 리모델링 계획 시 에너지 성능 향상을 위한 LT method의 적용 방법에 관한 연구 (An application of LT method for Design-decisions to improve energy performance of non-domestic buildings during the early stage of Remodeling Process)

  • 이승복;변소형
    • KIEAE Journal
    • /
    • 제3권4호
    • /
    • pp.3-14
    • /
    • 2003
  • Remodeling for an aged building is emerging as a potential alternative towards the future of the building industry. It is a more effective method than the new construction in environmental friendly view. Most of remodeling were aimed at the improvement of the function of the deteriorated finishing materials. But, at the early stage of remodeling process, energy performance of a building can be improved by adopting passive design solutions such as daylighting and natural ventilation. The purpose of this study is to explain the passive design strategy in remodeling process and to suggest a application of LT method. LT method is an energy-design tool which responds to parameters available early in design development. It provides an output of annual primary energy for lighting, heating, cooling and ventilation in non-domestic buildings. LT method basically uses the concept of passive zone and non-passive zones and should be used to evaluate the energy performance of a number of options and to make comparisons. In this paper, the process of LT method is introduced and investigated an applicability in our office building.

Passive shimming design with commercially available rectangular shim sheets on a cylinder for HTS NMR magnets

  • Ahn, Min Cheol
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권2호
    • /
    • pp.29-33
    • /
    • 2018
  • Although high-temperature superconducting (HTS) magnets have the potential merit of producing ultra-high field (>25 T), they have been not easy to apply to Nuclear Magnetic Resonance (NMR) because of the difficulty of field homogeneity improvement. This paper presents a design technique of passive shimming for HTS magnets. Ferromagnetic shimming design code was developed though MALAB, which includes the optimization algorithm. The proper shim element size was determined by a simulation. This design technique was verified by a case study design of a 3-T HTS magnet. We succeed to improve field homogeneity of the magnet from 634 ppm to 6.39 ppm at 10-mm diameter sphere volume. Feasibility of passive shimming for all-HTS NMR magnet was confirmed by this result.

패시브 하우스 디자인 요소를 적용한 농촌지역 단독주거건물의 난방에너지 모니터링 연구 (A Study on Heating Energy Monitoring of a Rural Detached House Applying Passive House Design Components)

  • 조경민;이태구;한영해
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.39-46
    • /
    • 2013
  • Recently, the field of construction is putting a variety of effort into reducing CO2, since global warming is being accelerated due to climate changes and the increase of greenhouse gas. For reduction of CO2 in the field of construction, it is required to make plans to cut down heating energy of buildings and especially, it is urgently needed to cut down energy of residential buildings in rural area where occupies the majority of consumption of petroleum-based energy sources. Therefore, this research compared and analyzed the actual energy consumption, by evaluating energy performance of a detached house applying passive house design components for reduction of energy. As the result, energy consumption showed remarkable differences, according to the operation of a heat recovery ventilation unit which is one of passive house design components, and building energy consumption displayed remarkable differences, too, depending on the difference of airtightness performance during building energy simulation conducted in process of design. Based on these results, the importance of airtightness performance of passive house was verified. The result of the actual measurement of energy consumption demonstrated that LNG was most economical amongst several heat resources yielded, on the basis of LPG source energy consumption measured within a certain period of time, and it was followed by kerosene. LPG was analyzed to have a low economic efficiency, when used for heating.

부하설비의 고조파 저감장치 설계 (Design of harmonic reduction equipment for load system)

  • 손재현;조양행;김제홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.224-228
    • /
    • 2006
  • The aim of this study is to design a passive filter for the elimination of harmonics. For this design, the harmonics wave generating from the six pulse rectifier was measured and its characteristics were analyzed. We also calculated the quantity of harmonic current by changing the system operational conditions. According to this field data and calculated results, we determined the elements of the passive filter. The simulation and experimental results indicate the efficiency of designed passive filter.

  • PDF

사고 영향 분석을 이용한 성능위주의 내화설계 (Performance Based Design of Passive Fire Protection Using Consequence Analysis)

  • 한동훈;이종호
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.102-107
    • /
    • 2004
  • Performance based design is a recent evolutionary step in the process of designing fire protection systems. In essence, it is a logical design process resulting in a solution that achieves a specified performance. Sometimes the prescriptive solutions presented in various codes and standards are too expensive or inflexible. Often the solutions do not and enables optimization of a solution for cost and function. In this study, performance based design was carried out to determine the extent of passive fire protection for oil terminal facilities. The results of performance based design were compared with those of prescriptive code based design. Performance based design is not always more economic than prescriptive code based design but provides more reliable and effective design that is fit for the purpose.