• Title/Summary/Keyword: passive construction

Search Result 267, Processing Time 0.024 seconds

A Study of Critical Items and Related Standards on Designing for Passive Apartments (패시브 공동주택 계획을 위한 설계 중점항목 및 관련 기준 연구)

  • Lee, Myoung-Ju
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.7
    • /
    • pp.21-29
    • /
    • 2018
  • This study aimed to find and suggest the purpose of future plans, critical items on designing and Related standards to amend construction standards for domestic energy saving and environmentally friendly housings. It would also activate and increase the supplies of passive house minimizing the problems on current apartment housings in winter and reducing heating energy which brings fine dust pollution. After defining the standard model of Korean apartment housings(reference model), this study calculated the amount of heating energy demand per unit area annually as applying the yearly changed standards from 2008 to 2017 to existing standard model. It turned out that applying 2017 construction standards of energy saving and eco-friendly housings to reference model has saved up to 75% of heating energy demand comparing to the one applied 2008's. However, it still could not solve the fundamental problems such as winter fungus, condensation, freezing, freeze and burst, and insulation weakness space, and could not be free from fine dust particles. To solve them, this study suggested improved standards adding critical items on design related to outside insulation, cut off the heat-bridge, enforce air-tightness and heat change efficiency on heat recovery ventilator. As a result, it has reduced more than 10% of heat demand from 2017. It would be more than 90% of savings from 2008 if we make the amount of heat loss be zero on heat bridge on designing stage in the future.

Deriving Priorities Based on Combination of Green Remodeling Application Elements in Old Public Libraries (노후 공공도서관의 그린리모델링 적용 요소 조합에 따른 우선순위 도출)

  • Sung Jin Sim;Se Hyeon Lim;Seong Eun Kim;Yong Woo Song
    • Land and Housing Review
    • /
    • v.15 no.2
    • /
    • pp.1-7
    • /
    • 2024
  • The Ministry of Land, Infrastructure, and Transport has been promoting strengthening energy efficiency of old buildings through public green building remodeling projects since 2020. Green remodeling includes both essential and optional construction of passive and active elements. However, there is a lack of integrated designs of passive and active systems and no standards for prioritizing these systems according to the building's age. Therefore, this study examined six public libraries in central region 2 that were expected to be high energy consuming. Remodeling strategy priorities were selected based on potential energy reduction. The libraries were divided into three groups based on their year of construction, completed in the 1980s (Model 1), 1990s (Model 2), and 2000s (Model 3). ECO2-OD, based on ISO 13790 and DINV 18599, was used as the primary energy consumption analysis tool. Simulation results indicated Model 1 and Model 2 benefited most from higher insulation and replacement of mechanical equipment. Model 3 benefited most from upgrading to more energy efficient windows.

A Preliminary Study on Active Learning Process in Construction Engineering (건설엔지니어링 대학교육의 능동적 학습방식 도입 기초 연구)

  • Cho Chang-Yeon;Lee Jun-Bok
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.610-613
    • /
    • 2003
  • Ensuring technical ability is essential in the construction industry to increase competitiveness in the global market. A new paradigm is coming up in academic education system to cultivate the competent engineers. The major objective of this research is to suggest a positive learning pattern In order to overcome the limitations of the passive learning style. A case study, technical upgrading with a tower crane, us explained in terms of active learning process, results, and evaluation of students' performance.

  • PDF

A Recommendation of the Technique for Measurement and Analysis of Passive Surface Waves for a Reliable Dispersion Curve (신뢰성 있는 분산곡선의 결정을 위한 수동표면파 측정 및 분석기법의 제안)

  • Yoon, Sung-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.2
    • /
    • pp.47-60
    • /
    • 2007
  • Conventional active surface wave measurements performed using a transient or continuous source are often limited in the maximum depth of penetration due to the difficulty of generating low-frequency energy with reasonably portable sources. This limitation may inhibit accurate seismic site response calculations because of the inability to define deeper subsurface structure. By measuring surface wave generated by passive sources including microtremors and cultural noise, it is possible to overcome this problem and develop soil stiffness profiles to much larger depth. Reliability of dispersion estimates from the passive surface wave measurements is critical to present reliable shear wave velocity profiles and can be improved by the measurements and analyses of passive surface waves based on correct understanding of systematic errors included in passive dispersion data. In this study, the systematic errors caused by poor wavenumber resolution and energy leakage into sidelobes in passive tests are mainly explored. Recommendations for reliable passive surface wave measurements and dispersion estimates are presented and illustrated at a site in San Jose, California, U.S.

An Efficient Algorithm for 3-D Range Measurement using Disparity of Stereoscopic Camera (스테레오 카메라의 양안 시차를 이용한 거리 계측의 고속 연산 알고리즘)

  • 김재한
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.6
    • /
    • pp.1163-1168
    • /
    • 2001
  • The ranging systems measure range data in three-dimensional coordinate from target surface. These non-contact remote ranging systems is widely used in various automation applications, including military equipment, construction field, navigation, inspection, assembly, and robot vision. The active ranging systems using time of flight technique or light pattern illumination technique are complex and expensive, the passive systems based on stereo or focusing principle are time-consuming. The proposed algorithm, that is based on cross correlation of projection profile of vertical edge, provides advantages of fast and simple operation in the range acquisition. The results of experiment show the effectiveness of the proposed algorithm.

  • PDF

The effect of active and passive confining pressure on compressive behavior of STCC and CFST

  • Nematzadeh, Mahdi;Fazli, Saeed
    • Advances in concrete construction
    • /
    • v.9 no.2
    • /
    • pp.161-171
    • /
    • 2020
  • In this paper, an experimental study was conducted on the compressive behavior of steel tube confined concrete (STCC) and concrete-filled steel tube (CFST) columns with active and passive confinement. To create active confinement in the STCC and CFST specimens, an innovative method was used in this study, in which by applying pressure on the fresh concrete, the steel tube was laterally pretensioned and the concrete core was compressed simultaneously. Of the benefits of this technique are improving the composite column behavior, without the use of additives and without the need for vibration, and achieving high prestressing levels. To achieve lower and higher prestressing levels, short and long term pressures were applied to the specimens, respectively. Nineteen STCC and CFST specimens in three groups of passive, short-term active, and long-term active confinement were subjected to axial compression, and their mechanical properties including the compressive strength, modulus of elasticity and axial strain were evaluated. The results showed that the proposed method of prestressing the STCC columns led to a significant increase in the compressive strength (about 60%), initial modulus of elasticity (about 130%) as well as a significant reduction in the axial strain (about 45%). In the CFST columns, the prestressing led to a considerable increase in the compressive strength, a small effect on the initial and secant modulus of elasticity and an increase in the axial strain (about 55%). Moreover, increased prestressing levels negligibly affected the compressive strength of STCCs and CFSTs but slightly increased the elastic modulus of STCCs and significantly decreased that of CFSTs.

A parametric study on the use of passive fire protection in FPSO topside module

  • Friebe, Martin;Jang, Beom-Seon;Jim, Yanlin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.4
    • /
    • pp.826-839
    • /
    • 2014
  • Fire is a continuous threat to FPSO topside modules as large amounts of oil and gas are passing through the modules. As a conventional measure to mitigate structural failure under fire, passive fire protection (PFP) coatings are widely used on main structural members. However, an excessive use of PFP coatings can cause considerable cost for material purchase, installation, inspection and maintenance. Long installation time can be a risk since the work should be done nearly at the last fabrication stage. Thus, the minimal use of PFP can be beneficial to the reduction of construction cost and the avoidance of schedule delay. This paper presents a few case studies on how different applications of PFP have influence on collapse time of a FPSO module structure. A series of heat analysis and thermal elasto-plastic FE analysis are performed for different PFP coatings and the resultant collapse time and the amount of PFP coatings are compared with each other.

Development of Energy Saving System Using the Microwave Sensor (마이크로웨이브 센서를 이용한 에너지 절약시스템 개발)

  • Jung, Soon-Won;Lee, Jae-Jin;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.404-407
    • /
    • 2008
  • Because of directly receiving the thing in which a microwave is reflected and comparing the frequency, the microwave sensor with doppler effect completely overcomes the problem of the passive infrared sensor. The microwave sensor with doppler effect well operates about a temperature, the dust, and the peripheral noise because of being dull in the most of ambient conditions. The system developed in this research is the electricity saving detection sensor which it senses the real time action of a man as the microwave sensor and automatically turns on the electric lamp and turns off, minimizes the electrical energy consumption. Since the microwave sensor is not influenced in the light, the dust, and the natural element like the ambient temperature, the effectiveness is considered to be superior to the passive infrared sensor being used currently. There was the energy reduction effect more than about 60% in the performed example which established this system. When this was compared with the construction cost, the cost of establishing payback period was about 1-1.5 year. The microwave sensor with doppler effect developed from this research result is convinced in the future to do enough for the electric energy saving.

Seismic response control of a building complex utilizing passive friction damper: Analytical study

  • Ng, C.L.;Xu, Y.L.
    • Structural Engineering and Mechanics
    • /
    • v.22 no.1
    • /
    • pp.85-105
    • /
    • 2006
  • Control of structural response due to seismic excitation in a manner of coupling adjacent buildings has been actively developed, and most attention focused on those buildings of similar height. However, with the rapid development of some modern cities, multi-story buildings constructed with an auxiliary low-rise podium structure to provide extra functions to the complex become a growing construction scheme. Being inspired by the positively examined coupling control approach for buildings with similar height, this paper aims to provide a comprehensive analytical study on control effectiveness of using friction dampers to link the two buildings with significant height difference to supplement the recent experimental investigation carried out by the writers. The analytical model of a coupled building system is first developed with passive friction dampers being modeled as Coulomb friction. To highlight potential advantage of coupling the main building and podium structure with control devices that provide a lower degree of coupling, the inherent demerit of rigid-coupled configuration is then evaluated. Extensive parametric studies are finally performed. The concerned parameters influencing the design of optimal friction force and control efficiency include variety of earthquake excitation and differences in floor mass, story number as well as number of dampers installed between the two buildings. In general, the feasibility of interaction control approach applied to the complex structure for vibration reduction due to seismic excitation is supported by positive results.

Experimental study on RFID frequency band and tag for construction material information management (건설자재 정보관리를 위한 RFID 주파수 대역 및 Tag에 관한 실험적 연구)

  • Han, ChoongHan;Ju, KiBum;Yang, SungHoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2007.11a
    • /
    • pp.874-877
    • /
    • 2007
  • 최근 건설 산업이 고도화, 지능화됨에 따라 건설자재정보의 효율적인 관리방안으로 RFID 기술을 이용하려는 연구 및 적용 사례가 증가 하고 있다. RFID(Radio Frequency Identification)란 라디오 주파수를 이용한 무선인식 기법을 뜻하는 것으로 건설자재에 RFID Transponder(이하 태그)를 부착하여 생산, 유통, 설비 등 전 과정의 정보 추적 및 관리가 가능하다. 그러나 RFID 시스템 특성상 전자기장이 형성되는 철골자재나 수분이 포함된 콘크리트, 도료(안료) 등의 자재에서는 RFID 적용이 쉽지 않다. 또한, 현재 사용 중인 RFID 장비마저도 표준화 되어 있지 않고 사용 주파수 대역 또한 각각 다르기 때문에 건설자재에 적용하기위한 RFID 시스템의 표준화 및 규격화가 절실하다. 본 논문에서는 건설자재에 RFID를 적용하기 위한 표준화 방향을 제시하는 기초 연구로써 목재, 철재 빔, 도료(안료), 콘크리트, 배관자재(철/동/PE)에 Passive Type의 일반(Pager) 태그, 금속 태그, 액체형 태그를 부착 매립하여 125KHz, 13.56MHz, 900MHz의 주파수 대역과 자재 물성별 인식거리 및 인식률 시험을 진행하여 건설자재에 RFID를 적용하기위한 표준 주파수 대역 및 재질에 따른 적정 태그를 제시하고자 한다.