• Title/Summary/Keyword: passive and active

Search Result 2,177, Processing Time 0.037 seconds

A Study for Coping Strategies and Anxiety of Patients with Chronic Pain in the Oriental Clinic (한의원 내원 만성 통증환자의 통증대처방식 및 불안에 대한 연구)

  • Lee, Kye-Seung;Lee, Seung-Gi
    • Journal of Oriental Neuropsychiatry
    • /
    • v.19 no.2
    • /
    • pp.123-132
    • /
    • 2008
  • Objective: This clinical research is conducted to find out coping strategies and anxiety of patients with chronic pain, and the correlation between pain coping strategy and anxiety. Method: 50 subjects who came to the local oriental clinic answered the questionnaires about VPMI(Vanderbilt Pain Management Inventory) and SAS(The Self-rating Anxiety Scale). Then we researched the characteristics of pain coping strategies and the correlation. Results: 1. The mean scores of passive coping, active coping, and SAS are 29.62, 17.90, and 38.32 respectively. 2. In the analysis of nonparametric test, the female subjects tend to take more passive coping than the male. The older subjects tend to take less active coping than the younger. Subjects who reported more intense pain tend to take more passive coping. 3. There is significant difference between passive coping and anxiety. Conclusion: Pain coping strategies are related with age, sex, intensity of pain, and anxiety. The therapeutic intervention of decreasing passive coping and increasing active coping may be useful to manage the chronic pain. Further study is needed to find out more adequate inquiries of active coping.

  • PDF

Stress, Coping and Suicidal Ideation among School-aged Children: Focused on Daegu/Gyeongbuk Region (학령기 아동의 스트레스와 대처 및 자살 생각: 대구.경북 지역을 중심으로)

  • Choi, Hye-Seon;Lee, Mi-Kyoung
    • Journal of the Korean Society of School Health
    • /
    • v.25 no.1
    • /
    • pp.85-94
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the stress, coping and suicidal ideation among school-aged children and provide evidence for developing a stress management program for them. Methods: Data were collected and analyzed from 308 fifth graders from 6 elementary schools located in Daegu/Gyeongbuk. Results: First, for stress by general characteristics, there were significant differences in economic status, school record, self-rated health and life satisfaction. Also, subcategory stress by gender, there was a significant difference in appearance stress. Second, passive/avoidant coping had a significant difference in gender. Social support seeking coping and passive/avoidant coping were significant differences in economic status. Active coping had a significant difference in school record. Passive/avoidant coping had a significant difference in self-rated health. Aggressive coping, active coping, social support seeking coping and passive/avoidant coping had significant differences in self-rated life satisfaction. Third, stress and coping had significant differences by suicidal ideation. Fourth, stress showed positive correlations with aggressive coping and passive/avoidant coping while revealing negative correlation with active coping. Conclusion: These results from the study suggest difference by gender and need more active and positive coping strategy for suicide prevention.

  • PDF

Wives Leisure Time and the Perceive Quality of Life (주부의 여가시간과 생활의 질 인식에 관한 연구 - 교육기 자녀를 가진 비취업 주부를 중심으로)

  • 한경미;황덕순
    • Journal of Families and Better Life
    • /
    • v.8 no.1
    • /
    • pp.69-82
    • /
    • 1990
  • The purposes of this are to figure out the amounts of leisure time of full-time homemakers and to find out leisure time factors contributed to raise the quality of life. The major findings are the followings: 1) Full-time homemakers spend 353 minutes(5.9 hours) on the average per day on the leisure. Time for active leisure(creative activities, sports activities, spectator events, going to the party, and so on) is 70 minutes, while that for passive leisure(watching TV. listening to the radio, reading newspapers. magazines. Books, chating, relaxing, card playing) is 283 minutes(4.7 hours). The passive leisure is the main type of spending leisure time. 2) The total leisure time of wives is significantly related to SES factors. The higher the wives age and education, the family income, and the age of the latest child, the more the wives total leisure time. But the more the family numbers, and the child numbers, the lower the leisure time. Active leisure time is highly rela ed to family income, while passive leisure time is considerably family composition. 3) The wives are mostly satisfied with their lives. The wives perceptions of the quality of life is related to wives's education, house type, and family income. 4) The wives total leisure time is not related to the quality of life. There is a positive correlation between active leisure time and the quality of life, while a negative relationship is between passive leisure time and the perception of the quality of life. 5) In analysis of causal model, it appears that family income and active leisure time of wives directly affect the perceived quality of life. The more the family income and active leisure time, the higher the quality of life. it is implicated for wives to take and active attitude and to reduce, if possible, passive leisure time and to increase active leisure time.

  • PDF

Comparison of Active and Passive Sampler for Determining Temperal and Spatial Concentration Assessment of the Main Volatile Organic Compounds Concentration in Shihwa Industrial Complex (시화산업단지에서 주요 휘발성유기물질의 시간적, 공간적 농도 파악을 위한 능동식과 수동식 시료채취기 비교)

  • Byeon, Sang-Hoon;Choi, Hyeon-Il;Moon, Hyung-Il;Lee, Jung-Geun;Kim, Jung-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.790-796
    • /
    • 2011
  • In this study, we measured the concentrations of volatile organic compounds (VOCs) in Shiwha area by using active and passive sampler. We did a comparative analysis of the characteristics of the active sampler and passive sampler. In the case of the passive sampler, the average TVOC concentration of the industrial area was 1.86 times higher than that of the residential area. In the case of the active sampler, the average TVOC concentration of the industrial area was 1.07 times higher than that of the residential area. When using the passive sampler, the concentration of VOCs in the industrial area was noted to be higher than the concentration found in the residential area. However, when we used the thermal desorption tube, the concentration of residential area was higher rather than that of industrial area in some substances such as trichloroethylene, toluene, ethylbenzene, and xylene. Toluene was a larger percentage of the overall BTEX ratio. In case of the passive sampler, the relative ratio of toluene, ethylbenzene, and xylene was higher in the industrial area than in the residential area. In contrast in case of the thermal desorption tube, the ratio of these substances was higher in the residential area rather than in the industrial area. The passive sampling in this study showed an appropriate method to analyze the temporal and spatial concentrations of air contaminants. This assessment would prove to be useful for its observance of standards or epidemical study.

Semi-active control of seismic response of a building using MR fluid-based tuned mass damper

  • Esteki, Kambiz;Bagchi, Ashutosh;Sedaghati, Ramin
    • Smart Structures and Systems
    • /
    • v.16 no.5
    • /
    • pp.807-833
    • /
    • 2015
  • While tuned mass dampers are found to be effective in suppressing vibration in a tall building, integrating it with a semi-active control system enables it to perform more efficiently. In this paper a forty-story tall steel-frame building designed according to the Canadian standard, has been studied with and without semi-active and passive tuned mass dampers. The building is assumed to be located in the Vancouver, Canada. A magneto-rheological fluid based semi-active tuned mass damper has been optimally designed to suppress the vibration of the structure against seismic excitation, and an appropriate control procedure has been implemented to optimize the building's semi-active tuned mass system to reduce the seismic response. Furthermore, the control system parameters have been adjusted to yield the maximum reduction in the structural displacements at different floor levels. The response of the structure has been studied with a variety of ground motions with low, medium and high frequency contents to investigate the performance of the semi-active tuned mass damper in comparison to that of a passive tuned mass damper. It has been shown that the semi-active control system modifies structural response more effectively than the classic passive tuned mass damper in both mitigation of maximum displacement and reduction of the settling time of the building.

Active Noise Control of 3D Enclosure System using FXLMS Algorithm (FXLMS 알고리즘을 이용한 3 차원 인클로저 시스템의 능동소음제어)

  • Oh, Jae-Eung;Yang, In-Hyung;Yoon, Ji-Hyun;Jung, Jae-Eun;Lee, Jong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.240-241
    • /
    • 2009
  • The method of the reduction of the duct noise can be classified by the method of passive control and the method of active control. However, the passive control method has a demerit to reduce the effect of noise reduction at low frequency (below 500Hz) range and to be limited by a space. Whereas, the active control method can overcome the demerit of passive control method. The algorithm of active control is mostly used the Least-Mean-Square (LMS) algorithm because the LMS algorithm can easily obtain the complex transfer function in real-time. Especially, When the Filtered-X LMS (FXLMS) algorithm is applied to an ANC system.

  • PDF

Comparison Study on Power Output Characteristics of Power Management Methods for a Hybrid-electric UAV with Solar Cell/Fuel Cell/Battery

  • Lee, Bohwa;Kwon, Sejin
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.4
    • /
    • pp.631-640
    • /
    • 2016
  • A dual-mode power management for a hybrid-electric UAV with a cruise power of 200W is proposed and empirically verified. The subject vehicle is a low-speed long-endurance UAV powered by a solar cell, a fuel cell, and a battery pack, which operate in the same voltage bounds. These power sources of different operational characteristics can be managed in two different methods: passive management and active management. This study proposes a new power management system named PMS2, which employs a bypass circuit to control the individual power sources. The PMS2 normally operates in active mode, and the bypass circuit converts the system into passive mode when necessary. The output characteristics of the hybrid system with the PMS2 are investigated under simulated failures in the power sources and the conversion of the power management methods. The investigation also provides quantitative comparisons of efficiencies of the system under the two distinct power management modes. In the case of the solar cell, the efficiency difference between the active and the passive management is shown to be 0.34% when the SOC of the battery is between 25-65%. However, if the SOC is out of this given range, i.e. when the SOC is at 90%, using active management displays an improved efficiency of 6.9%. In the case of the fuel cell, the efficiency of 55% is shown for both active and passive managements, indicating negligible differences.

Control of a Seismically Excited Cable-Stayed Bridge Employing a Hybrid Control Strategy (복합제어기법을 이용한 지진하중을 받는 사장교의 제어)

  • 박규식;정형조;이종헌;이인원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.338-345
    • /
    • 2002
  • This paper presents a hybrid control strategy for seismic protection of a benchmark cable-stayed bridge, which is provided as a testbed structure for the development of strategies for the control of cable-stayed bridges. In this study, a hybrid control system is composed of a passive control system to reduce the earthquake-induced forces in the structure and an active control system to further reduce the bridge responses, especially deck displacements. Lead rubber bearings and ideal hydraulic actuators are used fur the passive and active control systems. Bouc-Wen model is used to simulate the nonlinear behavior of lead rubber bearings and an H₂/LQG control algorithm is adopted as an active control algorithm. Numerical simulation results show that the performance of the proposed hybrid control strategy is superior to that of the passive control strategy and slightly better than that of the active control strategy. The proposed control method is also more reliable than the fully active control method due to the passive control part. Therefore, the proposed hybrid control strategy can effectively be used to seismically excited cable-stayed bridges.

  • PDF

Single Axis Vibration Isolation System Using Series Active-passive Approach (직렬형 능-수동 제진 방법을 이용한 1축 제진 시스템)

  • Banik, Rahul;Lee, Dong-Yeon;Gweon, Dae-Gab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.176-179
    • /
    • 2005
  • To control the vibration transmitted to the precision instruments from ground has always been of great interest among the researchers. This paper proposes a single axis vibration isolation system which can be used as a module far a table top six axis isolator for highly precise measurement and actuation system. The combined active-passive isolation principle is used for vertical vibration isolation by mounting the instrument on a passively damped isolation system made of Elastomer along with the active stage in series which consists of very stiff piezo actuator. The active stage works in combination with the passive stage for working as a very low frequency vibration attenuator. The active stage is isolated from the payload disturbance through the Passive stage and thus modularity in control is achieved. This made the control algorithm much easier as it does not need to be tuned to specific payload.

  • PDF

Performance analysis of the passive safety features of iPOWER under Fukushima-like accident conditions

  • Kang, Sang Hee;Lee, Sang Won;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.676-682
    • /
    • 2019
  • After the Fukushima Daiichi accident, there has been an increasing preference for passive safety features in the nuclear power industry. Some passive safety systems require limited active components to trigger subsequent passive operation. Under very serious accident conditions, passive safety features could be rendered inoperable or damaged. This study evaluates (i) the performance and effectiveness of the passive safety features of iPOWER (innovative Power Reactor), and (ii) whether a severe accident condition could be reached if the passive safety systems are damaged, namely the case of heat exchanger tube rupture. Analysis results show that the reactor coolant system remains in the hot shutdown condition without operator actions or electricity for over 72 h when the passive auxiliary feedwater systems (PAFSs) are operable without damage. However, heat exchanger tube rupture in the PAFS leads to core damage after about 18 h. Such results demonstrate that, to enhance the safety of iPOWER, maintaining the integrity of the PAFS is critical, and therefore additional protections for PAFS are necessary. To improve the reliability of iPOWER, additional battery sets are necessary for the passive safety systems using limited active components for accident mitigation under such extreme circumstances.