Hydrodynamic Characteristics of the Rectangular Type Circulating Fluidized Bed (4각 순환유동층의 수력학적 특성)

  • Hyun, Sang Yeol;Rhee, Kwan Seok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.10 no.4
    • /
    • pp.232-236
    • /
    • 1997
  • A rectangular type circulating fluidized bed (CFB) with an internal nozzle and two partition walls was proposed. In this modified CFB, an internal nozzle and two slanted partition walls were additionally set in the riser. This cold mode apparatus was made of acrylic resin; the riser was 1500mm high and $1000{\times}1000mm^2$ in the cross sectional area, the internal nozzle was 200mm high and 10mm in the inner diameter, and the partition wall was 7mm thick. Glass beads of $91{\mu}m$ in the mean diameter were employed as bed materials. In the cold mode by using the proposed CFB with an internal nozzle, it was possible to change the particle hold up by changing the gas flow ratio of the nozzle to the total(Qn/Qt). It was found that the inflection point which devided the bed structure between the dense and the dilute phase in the riser varied with Qn/Qt.

  • PDF

Experimental Study for Natural Convection Flow in an Inclined Partitioned Square Enclosure (격판이 존재하는 경사진 정사각형 밀폐공간 내의 자연대류유동에 관한 실험적 연구)

  • Kim, Gwang-Hui;Kim, Yu-Gon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.310-317
    • /
    • 2002
  • In the present study, an experimental study of natural convection in a partitioned 2D square enclosure has been carried out. The square enclosure consist of two adiabatic vertical walls and the upper cold and the lower hot walls. A partition is positioned perpendicularly at the center of the left vortical insulated wall. The PIV measurements were performed with the variations of Rayleigh number, partition length and inclination of the enclosure. The working fluid is water with Prandtl number of 6.996 at 20$\^{C}$. The captured images were analyzed by using a cross-correlation (two-frame/single-exposure) PIV method.

A Numerical Study on Effect of a Partition Wall Height on Wind Pressure Load when KTX passes through a Station (한국고속전철(KTX)이 역사를 통과할 때 격벽의 높이에 따른 풍하중의 변화에 대한 수치해석 연구)

  • Cho D.;Hur N.;Kim S. R.
    • Journal of computational fluids engineering
    • /
    • v.6 no.1
    • /
    • pp.56-62
    • /
    • 2001
  • A high speed train passing through a station may have undesired effects to passengers on platform due to abrupt pressure transients. Therefore it is very important to reduce the possible degree of danger by installing partition walls in passing lanes in designing the stations having passing train. In the present study, a pressure load to a passenger on platform is studied for the cases of various heights of the partition wall to assess the effectiveness of the wall on the passenger safety. From the results, it is seen that the pressure load on a passenger may be largely reduced by the partition wall. The heights of the partition wall for various passing speed are also studied based on the safety regulation.

  • PDF

EFFECT OF PARTITION AND SPECIES DIFFUSIVITY ON DOUBLE DIFFUSIVE CONVECTION OF WATER NEAR DENSITY MAXIMUM

  • Sivasankaran, S.;Kandaswamy, P.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.11 no.1
    • /
    • pp.71-83
    • /
    • 2007
  • The double diffusive convection of cold water in the vicinity of its density maximum in a rectangular partitioned enclosure of aspect ratio 5 with isothermal side walls and insulated top and bottom is studied numerically. A thin partition is attached to the hot wall. The species diffusivity of the fluid is assumed to vary linearly with concentration. The governing equations are solved by finite difference scheme. The effects of position and height of the partition, variable species diffusivity and enclosure width are analyzed for various hot wall temperatures. It has been found that adding partition on the hot wall reduces the heat transfer. The density inversion of the water has a great influence on the natural convection. When increasing species diffusivity parameter heat and mass transfer rate is decreased.

  • PDF

Evaluation of Sound Insulation Performance of Extruded Cement Panel with a-Hemihydrate Gypsum

  • Kim, Jin-Man;Choi, Duck-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.6
    • /
    • pp.575-585
    • /
    • 2012
  • The extruded cement panel, which has many advantages as a prefabricated method, has been limited in its application due to its low fire-resistance. However, an extruded cement panel produced by mixing a-hemihydrate gypsum offers dramatically improved fire-resistance and is expected to have wide-ranging applications in the construction sector as an interior material or partition wall between housing units. Sound insulation performance is very important for the partition wall between housing units. In this study, the sound insulation performance of the extruded cement panel produced through the mixture of a-hemihydrate gypsum is reviewed in order to determine its usability for a partition wall between housing units and for interior materials. Through the review it was found that the wall formed using the extruded cement panels produced by mixing the a-hemihydrate gypsum have ★★★ class in sound insulation test, equal or superior compared with the other two types of extruded cement panel walls currently available in the market.

A Computational Study of Natural Convection in Vertical Rectangular Enclosures with Partiton Plates of Finite Thermal Conductivity (유한열전도율(有限熱傳導率)의 격판(隔板)을 갖는 수직구형(垂直矩形) 밀폐공간(密閉空間)에서의 자연대류(自然對流)에 관(關)한 수치적(數値的) 연구(硏究))

  • Park, Man-Heung;Lee, Jae-Heon
    • Solar Energy
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1982
  • A theoretical study by numerical method has been performed on the natural convection of an air contained in enclosures. The enclosures have rectangular cross section with one vertical wall heated and the other cooled, and with two horizontal partition plates of finite thermal conductivity. Steady two-dimensional flow was assumed. The computation was executed by means of the Implicit Alternating Direction (I.A.D) finite-difference method. Two partition plates of Aluminium whose thickness were 0.05mm was employed in computation. Isothemals, streamlines, local Nusselt numbers and mean Nusselt numbers were obtained for various Grashof numbers and aspect ratio and these results were compared with those in the case of the enclosure with two horizontal insulated plates. From the present results, the heat transfer in the case of partition plates was greater than that in the case of insulation. This study suggests a method to measure the overall heat-transfer of coefficient in double walls which supported by partition plates for insulative construction.

  • PDF

A Development of Partition Wall for enhenced Sound Transmission Loss and Air Tightness (차음성능과 기밀성능이 향상된 경량 간막이벽 개발)

  • 배상환;박진우;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.855-860
    • /
    • 2001
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings. it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But. the required performances of a light-weight wall are not evaluated systematically. As a field survey result. partition walls of house-to-house and room-to-room were not showed their respected performances. so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially. occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Also to suppress indoor air movement. stact effect must be concerned. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings.

  • PDF

A Comparison Study of Equivalent Strut Models for Seismic Performance Evaluation of Masonry-Infilled Frame (조적채움벽 골조의 내진성능평가를 위한 등가 스트럿 모델의 비교연구)

  • Yu, EunJong;Kim, MinJae;Jung, DaeGye
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.79-87
    • /
    • 2014
  • Masonry-infilled walls have been used in reinforced concrete(RC) frame structures as interior and exterior partition walls. Since these walls are considered as nonstructural elements, they were only considered as additional mass. However, infill walls tend to interact with the structure's overall strength, rigidity, and energy dissipation. Infill walls have been analyzed by finite element method or transposed as equivalent strut model. The equivalent strut model is a typical method to evaluate masonry-infilled structure to avoid the burden of complex finite element model. This study compares different strut models to identify their properties and applicability with regard to the characteristics of the structure and various material models.

Efficient Micro-Ozone-Bubble Generation by Improving Ozone Dissolution Tank Structure (오존용해탱크 구조 개선을 통한 효율적인 마이크로오존버블 생성)

  • Park, Yong-hwa;Lee, Gwang-hi;Jang, Am
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.10
    • /
    • pp.549-555
    • /
    • 2017
  • The purpose of this study is to investigate how ozone-dissolution-tank structure affects micro-ozone-bubble distribution, energy consumption and water treatment efficiency. The partition walls inside the ozone-dissolution-tank generate pressure changes, shear forces, and swirling flows, which change the size of the bubble diameter. The size of the bubble diameter differs by 10.5% depending on the partition walls. Changes in ozone-bubble diameter are related to energy consumption. As the ozone-bubble becomes smaller, the bubble generation energy increases, but the ozone production energy decreases as the dissolution efficiency increases. Therefore, an ozone-dissolution-tank should be determined by means of an optimal condition producing a micro-ozone-bubble with a minimum sum of bubble generation energy and ozone production energy. The energy consumed to inject the same amount of ozone into the effluent differs by 2.5% depending on the partition walls. However, considering the water treatment efficiency, the conditions for selecting the ozone-dissolution-tank are variable. This is because the free radicals that increase as the ozone-bubble gets smaller are very efficient for water treatment. Even at the same ozone injection concentration, the water treatment efficiency differs by 10.4% according to the partition walls. Therefore, we have studied ozone-dissolution-tank structure which produces reasonable ozone-bubble considering water treatment efficiency and energy efficiency.