• 제목/요약/키워드: particle removal efficiency

검색결과 348건 처리시간 0.029초

비친수성유기물질(HOC)로 오염된 토양의 정화를 위한 동전기-생물활성화공정의 개발

  • 양지원;김상준;박지연;이유진;기대정
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.326-329
    • /
    • 2003
  • When an electrokinetic process is applied to a HOC-contaminated soil, hybrid types combined with soil flushing, chemical oxidation, and bioremediation are generally used. Especially when the electrokinetic process is combined with bioremediation, the hybrid technology can solve several limits of bioremediation such as low microbial mobility, low soil temperature, and shortage of nutrients in subsurface circumstance. Because microbial surface is charged negatively, the microorganism moves from cathode to anode under electrical field. In this study, mixed culture mainly-consisted by Pseudomonas sp. was applied to remediate pentadecane-contaminated kaolinite with particle size less than 300${\mu}{\textrm}{m}$. This remediation system was named ‘electrokinetic bioaugmentation’ and consisted of model aquifer, electrode reservoirs, bioreactor, power supply, and pump. The mixed culture above 0.5 of optical density in bioreactor was supplied to two reservoirs and penetrated soil when the electric current was applied. To enhance the removal efficiency, the optimal medium composition, electric current, and voltage were investigated.

  • PDF

나노패턴 세정을 위한 소형 메가소닉 모듈 개발 (Development of a Small-type Megasonic Module for Nano-scale Pattern Cleaning)

  • 김현세;이양래;임의수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1810-1814
    • /
    • 2008
  • A small L-type megasonic module for nano-pattern cleaning was designed and manufactured. The impedance graph of the quartz waveguide with a piezoelectric actuator was predicted using finite element method (FEM). The peak value of the piezoelectric actuator alone was 3.373 MHz, which was the same as the experimentally measured value of 3.373 MHz (0.0% error). In addition, the maximum impedance value of the quartz waveguide with the actuator was 3.373 MHz, which agreed well with the measured value of 3.362 MHz (0.3% error). The acoustic pressures of a conventional megasonic system (3 MHz) and the developed system under similar conditions were measured and compared. The results showed that the maximum values and standard deviations of the developed system decreased by 29% and 18%, respectively, compared with the conventional type. This suggests that the small L-type would have higher particle removal efficiency with lower possibilities of pattern damages.

  • PDF

제주시 한천 저류지의 수질 특성 (Characteristics of water quality at Han stream retention ponds in Jeju City)

  • 김진근
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.207-214
    • /
    • 2013
  • To evaluate characteristics of water quality in Jeju, a study was implemented for Han stream and retention ponds. Inflow water quality of retention ponds was heavily dependent on precedent rainfall, and no pesticide was detected due to the little artificial pollution sources. A smooth settling efficiency curve was noticed because heavy particles were already settled down in front of the retention pond. There were weak relationships between retention time and water quality, and this can be attributable to high concentration of pollutants influx at peak inflow. In addition, as Han stream retention pond has a role of groundwater recharge, inflow control based on water quality as well as quantity is needed to maximize pollutant removal at the retention ponds.

NUMERICAL STUDY FOR A SECONDARY CIRCULAR CLARIFIER WITH DENSITY EFFECT

  • Kim, Hey-Suk;Shin, Mi-Soo;Jang, Dong-Soon;Lee, Sang-Ill;Park, Jong-Woon
    • Environmental Engineering Research
    • /
    • 제10권1호
    • /
    • pp.15-21
    • /
    • 2005
  • A computer program is developed for the prediction of the flow pattern and the removal efficiency of suspended solid (SS) in a circular secondary clarifier. In this study the increased density effect by SS on hydrodynamics has been systematically investigated in terms of Froude Number (Fr), baffle existence, and a couple of important empirical models associated with the particle settling and Reynolds stresses. A control-volume based-finite difference method by Patankar is employed together with the SIMPLEC algorithm for the resolution of pressure-velocity coupling. The k-ε turbulence and its modified version are incorporated for the evaluation of Reynolds stresses. The calculation results predicts well the overall flow pattern such as the waterfall phenomenon at the front end of the clarifier and the bottom density current with the formation of strong recirculation especially for the case of decrease of Fr. Even if there are some noticeable differences in the prediction of two turbulence models, the calculated results of the radial velocity profiles are generally in good agreement against experimental data appeared in open literature. Parametric investigation has been systematically made with the Fr and baffle condition with detailed analysis.

Development of a Plate-type Megasonic with Cooling Pins for Sliced Ingot Cleaning

  • Hyunse Kim;Euisu Lim
    • 반도체디스플레이기술학회지
    • /
    • 제22권3호
    • /
    • pp.21-27
    • /
    • 2023
  • In this article, a plate-type megasonic cleaning system with cooling pins is proposed for the sliced ingot, which is a raw material of silicon (Si) wafers. The megasonic system is operated with a lead zirconate titanate (PZT) actuator, which has high electric resistance, thus when it is being operated, it dissipates much heat. So this article proposes a megasonic system with cooling pins. In the design process, finite element analysis was performed and the results were used for the design of the waveguide. The frequency with the maximum impedance value was 998 kHz, which agreed well with the measured value of 997 kHz with 0.1 % error. Based on the results, the 1 MHz waveguide was fabricated. Acoustic pressures were measured, and analyzed. Finally, cleaning tests were performed, and 90 % particle removal efficiency (PRE) was achieved over 10 W power. These results imply that the developed 1 MHz megasonic will effectively clean sliced ingot wafer surfaces.

  • PDF

H 광산배수 내 미세부유물질 및 용해성 중금속의 제거를 위한 침전 및 여과 공법에 관한 연구 (Settling and Filtering Process for the Treatment of Fine Suspended Solids and Soluble Heavy Metals in H Mine Drainage)

  • 오민아;김원기;김덕민;이상훈;이재영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권6호
    • /
    • pp.102-111
    • /
    • 2012
  • Fine suspended solids generated effluence from treatment process of mine drainage could destroy environment as the aesthetic landscapes, and depreciate water quality. Therefore, the purpose of this research is focused on process development applied the actual field for controlling fine suspended solids and heavy metals, and so lab-scale test was performed for inducement of basic data. The mine drainage used in this research was sampled in H mine located Jeongseon-gun, Gangwon-do. Concentration of suspended solid, arsenic, iron and manganese was exceeded the standard of contaminant limitation for the clean water, and particle size of suspended solid was less than 10 m as fine particle. Although hydraulic retention time of mine drainage for effective settling was required more than 6 hours, hydraulic retention time would be increased in winter season when the settling efficiency could be reduced because of viscosity decreasing. Moreover, installed inclination plate helped to increase settling efficiency of suspended solid about 48 %. Filtering media that was the most effective removal of suspended solids and heavy metal was decided granular activated carbon of 1~2 mm was the optimal size.

도로면 강우유출수의 입도분포를 고려한 여재특성 비교분석 (A Comparison of Filtering Characteristics of Various Media considering Particle Size Distribution of Road Runoff)

  • 구본진;최계운;최원석;송창수
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.299-312
    • /
    • 2013
  • This study investigated the contaminant loading and characteristics of particle size distributions(PSDs) in the rainfall runoff from two different sources, the pavement road and the ancillary parking lot, and then evaluated four different types of filter media(i.e., EPP, EPS, Zeolite, and Perlite) to treat runoff water. The results showed that runoff from the pavement road contains 5.6 and 20 times higher SS and Pb concentrations, respectively, than that from the parking lot. The particles smaller than $100{\mu}m$ occupied 89.8 % of runoff from the pavement road and 81.4 % of that from the parking lot by volume. The effect of the hydraulic loading, at 950 m/day filtering linar velocity and 40 cm head loss, was largest for Zeolite, followed by Perlite, EPS, and EPP. The return period of tested media calculated by the regression equation for head loss indicated that EPP has the longest life time. The average SS removal rate was similar for all media at between 84.9 % and 89 %, while the effect of various filter column heights was different, showing minimal for EPP and maximum for EPS. All filter media tested demonstrated over 95 % of SS treatment efficiency for the particles bigger than $100{\mu}m$, while for the ones smaller than $100{\mu}m$ the efficiency was in order of EPP(82.4%) > Perlite(76.1 %) > EPS(66.2 %) > Zeolite(65.2 %). The results in conclusion implies that EPP is most effective filter media for the highly contaminated fine particles from road runoff.

습식-펄스방전 복합시스템의 황산화물 및 질소산화물 제거성능 특성 (SOx and NOx removal performance by a wet-pulse discharge complex system)

  • 박현진;이환영;박문례;노학재;유정구;한방우;홍기정
    • 한국입자에어로졸학회지
    • /
    • 제15권1호
    • /
    • pp.1-13
    • /
    • 2019
  • Current desulfurization and denitrification technologies have reached a considerable level in terms of reduction efficiency. However, when compared with the simultaneous reduction technology, the individual reduction technologies have issues such as economic disadvantages due to the difficulty to scale-up apparatus, secondary pollution from wastewater/waste during the treatment process, requirement of large facilities for post-treatment, and increased installation costs. Therefore, it is necessary to enable practical application of simultaneous SOx and NOx treatment technologies to remove two or more contaminants in one process. The present study analyzes a technology capable of maintaining simultaneous treatment of SOx and NOx even at low temperatures due to the electrochemically generated strong oxidation of the wet-pulse complex system. This system also reduces unreacted residual gas and secondary products through the wet scrubbing process. It addresses common problems of the existing fuel gas treatment methods such as SDR, SCR, and activated carbon adsorption (i.e., low treatment efficiency, expensive maintenance cost, large installation area, and energy loss). Experiments were performed with varying variables such as pulse voltage, reaction temperature, chemicals and additives ratios, liquid/gas ratio, structure of the aeration cleaning nozzle, and gas inlet concentration. The performance of individual and complex processes using the wet-pulse discharge reaction were analyzed and compared.

양전하가 부가된 수처리 필터의 입자제거특성에 관한 연구 (A Study on the Positively Charged Filter for Removing Fine Particles in Water)

  • 정성학;김종원;김상희;전병헌;이승갑;이재근;안영철
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.454-460
    • /
    • 2012
  • The purpose of the present work is to investigate the removal characteristics of positively charged filters for capturing negatively charged particles such as bacteria and virus in water. In order to reduce the pressure drop and increase the filtration efficiency, the filter media, modified by charge modifier having positive functional groups, is developed and evaluated. Improved liquid filters have been developed with the modified surface charge to capture and adsorb particles by electrokinetic interaction between the filter surface and particles contained in an aqueous liquid. The positively charged filter media is composed of glass fiber, cellulose and poly-ethylenimine resin for positively charging with the variation of volume ratio. The zeta potential value of the positively charged filter is +37.92 mV at the glass fiber and cellulose content ratio of 50 : 50 with resin content of 100%, while that of the PSL test particle is -23.5 mV at pH 7. The removal efficiency of the electro-positively charged filter is 98% for PSL particles of 0.11 ${\mu}m$, while that of the negatively charged filter is 7%. The positively charged filter media showed the potential to be an effective method for removing fine particles from the contaminated water for liquid filtration.

지하철 목업차량내 객실 공기정화장치의 미세먼지(PM10) 및 $CO_2$ 저감성능평가 (Removal Efficiency of PM10 & $CO_2$ in Subway Mock-up Cabin)

  • 권순박;박덕신;조영민;김종범;조관현;남궁석;이주열;김태성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.613-618
    • /
    • 2011
  • More than 7 million persons use Seoul Metropolitan Subways (SMS) everyday and the number has been in increasing trend. With the increasing trend of concerns on indoor air quality(IAQ), the management of IAQ has become an important issue, especially in case of subway operators, because most of subway lines are placed underground with poor ventilation condition. The ultimate object of study develop independent cleaning device that reduce efficient fine particle and $CO_2$. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. Two layered electrically pre-charged filters were used for removing particulate matters and gas absorbers are packed between two layer filters for removing gases pollutants such $CO_2$, VOCs and HCHO. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. SCAP prototype is producted as all in one method which decrease fine dust, $CO_2$ and noxious gas. and basic test carry out with quantity of wind, a gap of pressure, sampling efficiency.

  • PDF