• Title/Summary/Keyword: particle removal efficiency

Search Result 348, Processing Time 0.023 seconds

Case Study on Remodeling Outlet Structure within a Sedimentation Basin for Improving Performance (침전지 유출부 구조 Remodeling을 통한 개선사례 연구)

  • Kim, Seong-Su;Park, No-Suk;Moon, Yong-Taik;Lee, Sun-Ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.911-918
    • /
    • 2006
  • This study was conducted to evaluate the effect of the launder type on settling performance and hydrodynamic behavior within the two certain full-scale sedimentation basins (each flow rate/one basin; $10,000m^3/d$); one is the transverse typed launder(existing basin) and the other is building the finger type launder in combination with the longitudinal baffle. Comparative experimental investigations have been carried out through residual turbidity and particle concentration measurements in each effluent from two basins with the transverse and the finger type launders, respectively. From the experimental results, we could observe that turbidity removal rate in the finger type launder basin (modified basin) is about 30% higher than that in the transverse type launder basin (existing basin). Also, from the measurement of total particle concentration in each effluent, the removal efficiency was improved about 27% within modified basin compared to the existing basin. In order to explain the comparative experimental results and investigate the hydridynamic behavior within each basin in more detail, we conducted computational fluid dynamics (CFD) simulation and verified simulation results with acoustic Doppler velocimetry (ADV) technique. From the CFD simulation, it was investigated that extreme upward flow occurs underneath of the transverse launder. On the other hand, in the case of modified basin, the upward flow, which occurred in the beneath of launder, was much less than that in the existing basins.

A Study on the Improvement of Treatment Efficiency for Nitrogen and Phosphorus by Improved Sewage Treatment Process in Constructed Wetland by Natural Purification Method (자연정화공법에 의한 인공습지 하수처리장에서 하수처리 공정개선에 따른 질소 및 인의 처리효율 향상 방안)

  • Seo, Dong-Cheol;Park, Woo-Young;Lim, Jong-Sir;Park, Chan-Hoon;Lee, Hong-Jae;Kim, Hong-Chul;Lee, Sang-Won;Lee, Do-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • To effectively treat the domestic sewage that was produced on a small-scale in farming and fishing village in order to encourage an ecologically friendly environment, a small-scale sewage treatment apparatus using natural purification methods that consisted of an aerobic and an anaerobic plots were constructed. The efficiency of sewage treatment according to the sewage loading was investigated to obtain the optimum sewage loading in small-scale sewage treatment apparatus. Removal rate of pollutants according to the sewage loading were in the order of $150\;Lm^{-2}day^{-1}{\fallingdotseq}300\;Lm^{-2}day^{-1}>600\;Lm^{-2}day^{-1}$. Therefore, the optimum sewage loading was 300 L m-2 day-1. Under the optimum sewage loading, removal rate of BOD, $COD_{Mn}$, turbidity, T-N and T-P were 99, 94, 99, 49 and 89%, respectively. However, to satisfy the water quality standard in effluent in small-sclae sewage treatment apparatus for domestic sewage treatment, the low removal efficiency of T-N and T-P must be improved. So to improve the removal rate of T-N and T-P, the efficiency of sewage treatment according to the improved sewage treatment process such as, re-treatment at aerobic plot, anaerobic condition of aerobic plot, changing the filter media sizes and the depths in anaerobic plot, and also addition of oyster shells to filter media at anaerobic plot were investigated. In case of 150 cm depth in anaerobic plot with filter medium A (effectivity particle size 1.50 mm) and addition of oyster shells to filter media at anaerobic plot, removal rate of T-N and T-P in both plots were increased by 10 and 3%, and 14 and 7% in comparison with 100 cm depth in anaerobic plot with filter medium B(effectivity particle size 0.95 mm), respectively. The optimum improved sewage treatment process in small-scale sewage treatment apparatus were 150 cm depth in anaerobic plot with filter medium A and addition of oyster shells to filter media at anaerobic plot.

Optimal Design of Mud Flushing System in Ballast tank of LNG Carrier (LNG선 Ballast Tank Mud Flushing System의 최적설계)

  • Park, Sang Hyeop;Song, Yoo Seok;Kim, Young Bok
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.2
    • /
    • pp.85-92
    • /
    • 2016
  • During ballast of a LNG carrier, the mud at the sea floor can enter the tanks together with the ballast water if the LNG terminal is located at shallow water region. In order to remove the mud deposited on the tank floor during deballasting, the mud flushing system in the ballast tanks is applied. In this study, various analyses to conform the efficiency in the mud removal are performed. In order to design the mud flushing system, the particle size of the mud is measured by particle size analyzer. Flushing performance is evaluated by numerical analysis. From the results of numerical analysis including flow field and piping system network, the optimized flushing system is determined.

Evaluation of NH4+-N Ion Exchange Property using Natural Zeolite and Zeolite Carrier (천연 제올라이트와 제올라이트 담체를 이용한 NH4+-N 이온교환 특성 평가)

  • Lee, Kwang Hyun;Park, Min Suk;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.750-757
    • /
    • 2009
  • The ammonium ion exchange characteristics of natural zeolite were investigated to remove ${NH_4}^+-N$. The effect of water temperature, particle size and competitive cation on the exchange capacity was examined. Ammonium ion exchange capacity tended to decrease when the temperature increased from $25^{\circ}C$ to $40^{\circ}C$. Exchange capacity was increased according to the particle size of natural zeolite comes to be small. Batch isotherm experiments were conducted for measuring ammonium ion exchange capacity. The ion exchange capacity was well described either by the Langmuir isotherm model or by the Freundlich isotherm model. The ammonium ion exchange capacity ($q_m$) of zeolite carrier can be calculated $11.744mg-{NH_4}^+/g$-carrier. The ion exchange capacity of manufactured zeolite carrier was showed a similar tendency as ion exchange capacity of powder-sized natural zeolite. Therefore, zeolite carrier can be used for increasing of nitrogen removal efficiency in the wastewater treatment plants.

Assessment of Characteristics of Biofilm Formed on Autotrophic Denitrification

  • JANG AM;BUM MINSU;KIM SUNGYOUN;AHN YEONGHEE;KIM IN S;BISHOP PAUL L
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.3
    • /
    • pp.455-460
    • /
    • 2005
  • A pilot-scale sulfur particle autotrophic denitrification (SPAD) process for the treatment of municipal wastewater was operated for 10 months at Shihwa, Korea, and higher than $90\%\;NO^{-}_{3}-N$ removal efficiency was observed. Plate counting showed that the lower part of the denitrifying column reactor had the most autotrophic denitrifiers. The biofilm thickness formed on sulfur particles from the SPAD reactor was approximately $25-30\;{\mu}m$, measured by DAPI (4,6-diamidino-2-phenylindole) staining. The presence of bacteria inside the highly porous sulfur particle was also monitored by SEM observation of the internal surfaces of broken sulfur particles. Biofilm extracellular polymeric substances (EPS) analysis showed that the ratio of carbohydrate to protein decreased with the reactor heights at which biofilm-formed sulfur particles were obtained.

Application of Newly PAC Selection Method Based on Economic Efficiency (경제성을 고려한 새로운 PAC 선정방법의 적용)

  • Kim, Young-Il;Bae, Byung-Uk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.11
    • /
    • pp.1141-1147
    • /
    • 2006
  • In order to applicate a newly method for powdered activated carbon(PAC) selection based on economic efficiency, PAC adsorption tests were performed for removal of MIB and dissolved organic carbon(DOC) in drinking water supplies. The removal rate of MIB increased when the PAC dose increased. The Coal-based PACs were superior for adsorption of MIB compared to wood-based PACs. PAC adsorption of DOC and $UV_{254}$ were a little different for different PACs and types of raw water, but both were lower than adsorption of MIB. Among the tested PACs, the one called P-1000 was most effective for removal of MIB, DOC and $UV_{254}$. Most of the organics in the tested samples were proven by excitation emission matrix(EEM) results to be fulvic-like materials. Especially, fulvic-like materials, humic-like materials, and soluble microbial byproduct(SMP)-like materials decreased after contact with PAC. P-1000 which had the lowest MIB cost index(MCI) was selected as the optimum PAC for the target water. PAC efficiency and treatability, particle size and distribution, and the cost associated with PAC dosing for MIB removal according to DOC concentration should all be considered before making the final selection of the best PAC for the target water.

Development and experimental verification of vortex typed nonfilter nonpoint source pollution reduction device (와류형 미필터 비점오염저감장치의 개발과 실험적 검증)

  • Jang, Suk Hwan;Lee, Jae-Kyoung;Lee, Hae-Kwang;Hwang, Sung-Gyu
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.4
    • /
    • pp.265-277
    • /
    • 2019
  • The objective of this study was to develop and verify an effective vortex typed nonfilter nonpoint source pollution reduction device. To verify this pollution reduction device, a total of twelves scenarios (three rainfall intensities${\times}$two states${\times}$two steps) of experiments were conducted using pollutants. First, simulated inflow (rainfall intensity 2.5 mm/hr: $0.00152m^3/s$, rainfall intensity 3.395 mm/hr: $0.00206m^3/s$, rainfall intensity 6.870 mm/hr: $0.00326m^3/s$) was calculated. Second, pollutants (mixture of 25% of four particle sizes) were selected and injected. Third, pollutant removal efficiencies of this device at its initial state and operating states were measured. As a result of analysis based on rainfall intensity, the concentration of pollutants was decreased by the device at initial and operating states at all rainfall intensities. Its pollutant removal efficiency was more than 80%, the standard set by the Ministry of Environment. Its pollutant removal efficiency was gradually increased over time, reaching approximately 90%. Its pollutant removal efficiency was higher in its operating state than that in its initial state. Therefore, nonpoint source pollutants can be effectively removed by this vortex typed nonpoint source pollution reduction device developed in this study.

Experimental Application of DAF Hybrid Process to Remove Algae Particles for Conventional Water Treatment Processes and Change of Particle Characteristics (재래식 정수처리공정에서 조류입자 제거를 위한 DAF Hybrid 공정의 실험적 적용과 입자특성 변화)

  • Kwak, Dong-Heui;Yoo, Seung-Joon
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.516-520
    • /
    • 2008
  • There are many water treatment plants built over couple of decade ago in Korea. For most of those plants, they are required a countermeasure to cope with the deterioration caused from the superannuated facilities and the objective materials change of water treatment from inorganic particles like clay to algae particles due to eutrophication of lake and reservoir. A series of field and laboratory experiments was performed to investigate the feasibility of DAF hybrid process and the variation of particle characteristics by applying the additional DAF unit in conventional water treatment processes. On the basis of this experiments, the DAF was effective as an additive process in filtration basin (DAF-CSF combination processes). Using DAF-CSF combination process, the efficiency of stable particle removal can be achieved to produce the safe drinking water.

CFD Analysis on the Flow in the Connection Duct of the Cyclone-Bag Hybrid Dust Collector (사이클론-백 하이브리드형 집진장치에서 유동연결부 설계조건에 따른 유동균일성 전산해석)

  • Koo, Seongmo;Oh, Wonchul;Chang, Hyuksang
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.115-126
    • /
    • 2016
  • Numerical analysis was done to evaluate the movement of the particles and the fluid inside of the cyclone-bag hybrid dust collector. Flow discharged from the cyclone in the hybrid particle collector has swirl pattern, and it results in the biased flow to the bag filters and deteriorates the collection performance of the bag filter. The current study is to evaluate the effect of the duct lengths and the baffle arrays in the connection duct by the computational methods. Main concerns of the analysis are how to improve the uniformity of the internal flow between the cyclone and the bag filter. Numerical analysis was done to check the particle removal efficiencies of the system with respect to the flow characteristics which is expressed in RMS values of the upward flow inside of the connection duct. The flow pattern inside of the connection duct is evaluated under different the duct lengths and the baffle arrays. In case of the reference geometry the RMS value of inside flow was 56.7%, and the value was decreased to 30.1% by controlling the lengths of duct. The effects of baffle was also evaluated, the RMS value of flow could be decreased 55.2% and so on. But the pressure drop across the baffles becomes high and the system efficiency becomes lower.

Application of surface modified sericite to remove anionic dye from an aqueous solution

  • Choi, Hee-Jeong
    • Environmental Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.312-319
    • /
    • 2017
  • The treatment of dyeing wastewater is not easy because dyes are mainly aromatic, heterocyclic compounds. The most effective technologies and methods to treat dyeing wastewater are costly and involve materials that are difficult to regenerate after use. Therefore, it is necessary to develop cost-effective, eco-friendly technologies to treat dyeing wastewater. The aim of this study was to investigate the removal of sulfur blue 11 (CI 53235) anionic dye using methyl esterified sericite (ME-sericite) adsorbents in an aqueous solution. The results are discussed in terms of the ME-sericite particle size, temperature, pH value and initial sorption rate according to the initial sulfur blue concentration. In addition, we analyzed the adsorption kinetics using a Pseudo-second-order model with the desorption and reusability. The methyl esterification caused a considerable increase in the specific surface area from 4.45 to $17.62m^2/g$. The ME-sericite adsorbents successfully removed > 98% of the sulfur dye in the aqueous solution. For the adsorption of 1 mg of sulfur dye, approximately 4.6 to 6.6 g/L ME-sericite were required. The desorption process was carried out by mixing a NaOH eluent to desorb 90.56% of the sulfur dye with 2 h of contact time. Thus, the ME-sericite is a promising adsorbent to treat dyeing wastewater due to its low dose requirement, high removal efficiency and inexpensive material.