• Title/Summary/Keyword: particle removal efficiency

Search Result 348, Processing Time 0.027 seconds

Particle Swarm Optimization for Snowplow Route Allocation and Location of Snow Control Material Storage (Particle Swarm Optimization을 이용한 제설차량 작업구간 할당 및 제설전진기지 위치 최적화)

  • Park, U-Yeol;Kim, Geun-Young;Kim, Sun-Young;Kim, Hee-Jae
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.4
    • /
    • pp.369-375
    • /
    • 2017
  • This study suggests PSO(Particle Swarm Optimization) algorithm that optimizes the snowplow route allocation and the location of the snow control material storage to improve the efficiency in snow removal works. The modified PSO algorithm for improving the search capacity is proposed, and this study suggests the solution representation, the parameter setting, and the fitness function for the given optimization problems. Computational experiments in real-world case are carried out to justify the proposed method and compared with the traditional PSO algorithms. The results show that the proposed algorithms can find the better solution than the traditional PSO algorithms by searching for the wider solution space without falling into the local optima. The finding of this study is efficiently employed to solve the optimization of the snowplow route allocation by minimizing the workload of each snowplow to search the location of the snow control material storage as well.

An experimental study on the filtration test of cotton ball filters (코튼볼 여재의 여과 특성 실험 연구)

  • Kim, Sunghong;Kim, Heejun;Kim, Donghan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.79-86
    • /
    • 2019
  • In order to measure the filtration characteristics of a cotton ball shape filter, the experiments of suspended solids(SS) surrogate material selection and filtration performance have been carried out in this study. Between the two materials of powdered activated carbon(PAC) and powdered red-clay, PAC is more suitable surrogate material in terms of experimental criteria and particle size distribution in the non-point source pollutants removal system. As a result of the filtration experiments with the cotton ball shape filter, the initial headloss was about 8 cm, and the headloss slightly increased over filtration time. The Kozeny-Carman equation was used to analyze the changes of pressure and porosity during the filtration. The initial porosity was calculated as 0.945 and it decreased to 0.936 at the end of design filtration time. As the filtration continued, the SS concentration of the filtered water gradually increased and the SS removal rate gradually decreased. When the SS target removal efficiency is assumed to be 80%, the cumulative SS removal capacity is expected as $28.8kg/m^2$. This means the volume loading rate of the cotton ball shape filter can be $115m^3/m^2$ when the typical SS concentration of non-point source water pollution is assumed as 250 mg/L.

Prediction of Wet Scrubber Particle Removal Efficiency due to Diffusion, Interception and Impaction (확산, 차단, 충돌에 의한 세정탑의 입자 제거 효율 예측)

  • 김현태;정창훈;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.213-214
    • /
    • 2000
  • 입자상 물질을 제거하기 위한 수단으로는 싸이클론, 필터, 전기집진기, 세정탑 등이 있다. 이중에 세정탑은 설치 및 운전이 편리한 반면, 미세 입자 제거 효율이 낮아 산업체에서 제한적으로 사용되고 있다. 이러한 결점, 즉 미세 입자의 제거 효율을 높이기 위해 다양한 형태의 세정탑이 연구되었으나(Laitinen et al., 1997; Fan et al., 1988), 대부분 실험적인 연구로서 세정탑에서 입자의 제거 기작이나 크기 분포 특성을 설명하지는 못한다. (중략)

  • PDF

Absorption Characteristics of Sulfur Dioxide in Jet Bubbling Reactor (가스분사반응기에서의 SO2 흡수 특성)

  • Choi, Byung-Sun;Park, Seung-Soo;Kim, Yung-whan
    • Applied Chemistry for Engineering
    • /
    • v.5 no.5
    • /
    • pp.836-842
    • /
    • 1994
  • The optimum design conditions of gas sparger pipe and the effects of operating variables on $SO_2$ removal efficiency have been examined in Jet Bubbling Reactor. Geometry of gas sparser pipe of Jet Bubbling Reactor is a very important factor to obtain a effective gas-liquid contact. Test results revealed that Reynolds numbers at sparger and slot have to be kept greater than 12,000 identically at a given gas velocity. $SO_2$ removal efficiency was a function of ${\Delta}P$, pH, inlet $SO_2$ concentration and particle size of limestone and was more sensitive to the change of ${\Delta}P$ than to the changes of others. The ${\Delta}P$ of at least 230mmAq must be maintained to acheive the above 90% $SO_2$ removal at pH of 4.0 which is considered as adequate operating pH. Higher $SO_2$ removal efficiency was obtained even at lower pH ranges, which resulted from the complete oxidation of the absorbed $SO_2$ to sulfates by adding air and consequently from the reduction of $SO_2$ equillibrium partial pressure in the gas-liquid interface The 99.5% of the limestone utilization was attained in pH range from 3.0 to 5.0 with regardless to the particle size of limestone employed.

  • PDF

A Study on Desulfurization Efficiency of Limestone Sludge with Particle Size (석회석 슬러지의 입도제어에 따른 배연탈황효율에 관한 연구)

  • Seo, Sung Kwan;Chu, Yong Sik;Shim, Kwang Bo
    • Resources Recycling
    • /
    • v.24 no.6
    • /
    • pp.17-23
    • /
    • 2015
  • Flue gas desulfurization(FGD) is the technique to remove $SO_2$ gas from stack gases of coal-fired plants. Many researcher have studied to replace the desulfurizing agent because FGD systems use a lot of limestone and energy. In this study, we use the limestone sludge which is a by-product of steel industry in order to replace desulfurizing agent of FGD system by control the particle size of limestone sludge. And desulfurization performance test is implemented by investigating $SO_2$ gas removal properties upon the characteristic of the limestone sludge with various particle size.

Effect of Bubble Size in DAF (DAF에서 기포크기의 영향)

  • Park, Yong-Hyo;Han, Moo-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.528-533
    • /
    • 2003
  • Bubble size is one of the most important parameters affecting DAF (Dissolved-Air-Flotation) process. It is generally known that small bubbles are preferred. However, the fact seems to be based on the particle removal efficiency at contact zone only, without considering separation zone. Besides, the effect of bubble size on the overall DAF process has not been fully investigated yet. Therefore, the effect of bubble size on collision efficiency, collision chances, and surface loading rate is calculated using theoretical models, and the results are discussed in this paper.

Evaluation of Removal Efficiencies of Micropollutants in Wastewater Treatment Plants (산업폐수처리장에서의 미량유해물질 제거율 평가)

  • Lee, In-Seok;Sim, Won-Jin;Oh, Jeong-Eun;Kim, Chang-Won;Chang, Yoon-Seok;Yoon, Young-Sam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.2
    • /
    • pp.214-219
    • /
    • 2007
  • 66 micropollutants analyses in 9 wastewater treatment plants(WWTPs) along Nak-dong river were implemented to identify the concentrations and removal efficiencies before and after treatment processes. As a result of study, the concentration levels discharged from WWTP effluents to water system were below the water quality criteria and the levels of other studies. The removal efficiencies were 84.6%(DAF/CCR) and 81.6%(AC) for 1,4-dioxane. Phenol, Clphs and PAHs were removed 94.6%, 66.4% and 80.6% respectively by the activated sludge(AS) process. The removal efficiencies of Clbzs were 45.3% for the activated sludge(AS) process and 60.6% for the activated carbon(AC) process. However, other processes besides AS and AC, the removal efficiencies of Clbzs were very low(<20%). The sand filtration(SF) process that could remove particle matters showed the best efficiency for PCDDs / Fs removal$(\geq99%)$. However, in case of relatively low PCDDs/Fs concentration level in influent, the removal efficiency was not so high$(\leq50%)$.

Effect of Operating Parameters on Microbial Desulfurization of Coal by Acidithiobacillus ferrooxidans. (Acidithiobacillus ferrooxidans에 의한 생물학적 석탄탈황에 미치는 조업인자의 영향)

    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.4
    • /
    • pp.400-407
    • /
    • 2003
  • In microbial coal desulfurization process (MCDP) by using Acidithiobacillus ferrooxidans, the effect of process variables on pyritic sulfur removal efficiency has been investigated. The inhibitory effect of toxic materials contained in coal matrix on the activity of desulfurizing bacteria have been evaluated in coal extracts, and the results showed that the method was useful to evaluate the applicability of a coal which is to be desulfurization to MCDP. The removal efficiency increased with decreasing particle size and decreases with increasing pulp density, but has no significant influence of particle size and pup densities at high pulp densities over 20 wt%. The mass transfers of gaseous nutrients such as oxygen and carbon dioxide into coal slurry with various pulp densities and coal particle size has been studied in an airlift bioreactor. Mass transfer coefficient was independent of pulp density in coal slurry with fine particle below 175 $\mu\textrm{m}$, but significantly decreased with increasing pulp density over 225 $\mu\textrm{m}$. The coal particles over 575 $\mu\textrm{m}$ were significantly settled to the bottom of bioreactor resulting in poor mixing. Considering mass transfer, pulp density and coal mixing, an optimal size of coal particle for the microbial coal desulfurization process seems to be about 500 $\mu\textrm{m}$.

Treatment Efficiency of Pollutants in Constructed Wetlands under Different Hydroponic Wastewater Injection Methods and Characteristic of Filter Media (시설하우스 폐양액 주입방법 및 여재 특성에 따른 인공습지에서 수질오염물질의 처리효율)

  • Seo, Dong-Cheol;Park, Jong-Hwan;Cheon, Yeong-Seok;Park, Seong-Kyu;Kim, Ah-Reum;Lee, Won-Gyu;Lee, Sang-Won;Lee, Seong-Tae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.2
    • /
    • pp.146-151
    • /
    • 2010
  • In order to improve T-N and T-P removal in HF (horizontal flow)-HF hybrid constructed wetlands by natural purification method for treating the hydroponic wastewater in greenhouses, the efficiency of water treatment as affected by the injection method of hydroponic wastewater, the addition of special filter media, the particle size of filter media, and the injection ratio of hydroponic wastewater in $1^{st}$ HF and $2^{nd}$ HF beds were investigated in small-scale HF-HF hydroponic wastewater treatment apparatus. Removal rate of T-P in the water in HF-HF hydroponic wastewater treatment apparatus with calcite as affected by addition method of special filter media was higher than that in HF-HF hydroponic wastewater treatment apparatus with other filter media. Removal rate of BOD, COD, SS, T-N and T-P in the water in mixed filter media with calcite were 86, 84, 87, 50 and 97%, respectively. Removals of pollutants except for T-P in the water were slightly different. Therefore, it should be considered that the removal rate of T-P was good for calcite in HF-HF hydroponic wastewater treatment apparatus. To improve T-N and T-P removal, the optimum particle size of filter media was 1.2 mm, and the optimum injection ratio ($1^{st}$ HF bed : $2^{nd}$ HF bed) of hydroponic wastewater was 60:40.

Comparison of Pollutant Removal Efficiency in Road Sediment with Media Using Filter Separator (필터 분리기를 이용한 여재별 도로퇴적물의 오염물질 제거효율 비교)

  • Bang, Ki-Woong;Lee, Jun-Ho;Choi, Chang-Su;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.332-340
    • /
    • 2007
  • Storm runoff from road contains significant loads of particulate and dissolved solids, organic constituents and metal elements. Micro particle is important when considering pollution mitigation because pollutant metal and organics have similar behavior with particles. The objective of this research is to evaluate the hydrodynamic filter separator performance for road storm runoff treatment. A various types of media such as perlite, granular activated carbon, zeolite were used for column test packing media and filter separator, and to determine the removal efficiency with various surface loading rate. As the results of column test, the highest SS removal efficiency was using mixed media(granular activated carbon, zeolite and perlite), and granular activated carbon mixed with zeolite has higher heavy metal removal efficiency than perlite. In laboratory scale hydrodynamic filter separator study, the operation ranges of surface loading rates were from 192 to 1,469 $m^3/m^2/day$. The estimated overall removal efficiencies of hydrodynamic filter separator for typical storm runoff were SS 48.1%, BOD 31.9%, COD 32.6%, TN 15.5%, and TP 17.3%, respectively. For the case of heavy metals, overall removal efficiencies were Fe 26.0%, Cu 19.4%, Cr 25.7, Zn 16.6%, and Pb 15.0%, respectively. The most appropriate medium for hydrodynamic filter separator was perlite mixed with granular activated carbon to treatment of road storm runoff.