• 제목/요약/키워드: particle detection

검색결과 310건 처리시간 0.028초

TEV 검출에 의한 가스 절연 개폐기의 절연 진단 (Insulation Diagnosis of Gas-Insulated Switchgears by TEV Detection)

  • 공정배;길경석;김성욱
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.307-312
    • /
    • 2019
  • Transient earth voltage (TEV) signals propagate on metal surfaces when partial discharge (PD) occurs due to the deterioration of insulation performance in the operation of gas-insulated switchgears (GIS). A TEV sensor has advantages of high sensitivity and convenient installation for detecting PD defects. However, the TEV sensor depends on imports in domestic and detailed studies have not been conducted. In this study, a sensor was designed and fabricated by the TEV principle and its response characteristics were evaluated for detecting PD defects, which were simulated as protrusion on conductor (POC), protrusion on enclosure (POE), and free moving particle (FMP) defects. Finally, the PD-induced TEV signals were measured and phase-resolved partial discharge (PRPD) patterns were analyzed to identify the type of defect.

Simultaneous Determination of Cysteamine and Cystamine in Cosmetics by Ion-Pairing Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Yejin;Na, Dong Hee
    • Toxicological Research
    • /
    • 제35권2호
    • /
    • pp.161-165
    • /
    • 2019
  • Cysteamine has been used in cosmetics as an antioxidant, a hair straightening agent, and a hair waving agent. However, recent studies indicate that cysteamine can act as an allergen to hairdressers. The objective of this study was to develop and validate a simple and effective reversed-phase high-performance liquid chromatography (RP-HPLC) method for the measurement of cysteamine and its dimer, cystamine. Sodium 1-heptanesulfonate (NaHpSO) was used as an ion-pairing agent to improve chromatographic performance. Separation was performed on a Gemini C18 column ($250mm{\times}4.6mm$, $5{\mu}m$ particle size) using a mobile phase composed of 85:15 (v/v) 4 mM NaHpSO in 0.1% phosphoric acid:acetonitrile. UV absorbance was monitored at 215 nm. The RP-HPLC method developed in this study was validated for specificity, linearity, limit of detection, limit of quantitation, precision, accuracy, and recovery. Cysteamine and cystamine were chromatographically resolved from other reducing agents such as thioglycolic acid and cysteine. Extraction using water and chloroform resulted in the recovery for cysteamine and cystamine ranging from 100.2-102.7% and 90.6-98.7%, respectively. This validated RP-HPLC method would be useful for quality control and monitoring of cysteamine and cystamine in cosmetics.

접착층을 고려한 플라즈모닉 금 나노 디스크의 광산란 특성 (Effect of Adhesion layer on the Optical Scattering Properties of Plasmonic Au Nanodisc)

  • 김주영;조규만;이경석
    • 대한금속재료학회지
    • /
    • 제46권7호
    • /
    • pp.464-470
    • /
    • 2008
  • Metallic nanostructures have great potential for bio-chemical sensor applications due to the excitation of localized surface plasmon and its sensitive response to environmental change. Unlike the commonly explored absorption-based sensing, the optical scattering provides single particle detection scheme. For the localized surface plasmon resonance spectroscopy, the metallic nanostructures with controlled shape and size have been usually fabricated on adhesion-layer pre-coated transparent glass substrates. In this study, we calculated the optical scattering properties of plasmonic Au nanodisc using a discrete dipole approximation method and analyzed the effect of adhesion layer on them. Our result also indicates that there is a trade-off between the surface plasmon damping and the capability of supporting nanostructures in determining the optimal thickness of adhesion layer. Marginal thickness of Ti adhesion layer for supporting Au nanostructures fabricated on a silica glass substrate was experimentally analyzed by an adhesion strength test using a nano-indentation technique.

윤활유 분석 센서를 통한 기계상태진단의 문헌적 고찰 (윤활유 센서의 종류와 기능) (Literature Review of Machine Condition Monitoring with Oil Sensors -Types of Sensors and Their Functions)

  • 홍성호
    • Tribology and Lubricants
    • /
    • 제36권6호
    • /
    • pp.297-306
    • /
    • 2020
  • This paper reviews studies on the types and functions of oil sensors used for machine condition monitoring. Machine condition monitoring is essential for maintaining the reliability of machines and can help avoid catastrophic failures while ensuring the safety and longevity of operation. Machine condition monitoring involves several components, such as compliance monitoring, structural monitoring, thermography, non-destructive testing, and noise and vibration monitoring. Real-time monitoring with oil analysis is also utilized in various industries, such as manufacturing, aerospace, and power plants. The three main methods of oil analysis are off-line, in-line, and on-line techniques. The on-line method is the most popular among these three because it reduces human error during oil sampling, prevents incipient machine failure, reduces the total maintenance cost, and does not need complicated setup or skilled analysts. This method has two advantages over the other two monitoring methods. First, fault conditions can be noticed at the early stages via detection of wear particles using wear particle sensors; therefore, it provides early warning in the failure process. Second, it is convenient and effective for diagnosing data regardless of the measurement time. Real-time condition monitoring with oil analysis uses various oil sensors to diagnose the machine and oil statuses; further, integrated oil sensors can be used to measure several properties simultaneously.

Detection of Toxoplasma gondii Infections using Virus-Like Particles Displaying T. gondii ROP4 Antigen

  • Kim, Min-Ju;Mao, Jie;Kang, Hae-Ji;Chu, Ki-Back;Quan, Fu-Shi
    • Parasites, Hosts and Diseases
    • /
    • 제59권6호
    • /
    • pp.565-572
    • /
    • 2021
  • Toxoplasma gondii ME49 infections are typically diagnosed by serological tests. However, serological diagnosis of RH strain-induced toxoplasmosis remains unknown. In order to develop seradiagnosis of above 2 kinds of infections, we generated recombinant virus-like particles (VLPs) displaying the T. gondii rhoptry protein 4 (ROP4) and evaluated their potential in T. gondii ME49 or RH strain infection diagnostics. Mice were orally infected with either the tachyzoites of T. gondii (RH) or cysts of T. gondii (ME49) at various dosages, and sera were collected at regular intervals. ELISA-based serological tests were performed to assess IgG, IgM, and IgA antibody responses against ROP4 VLP antigen and tissue lysate antigen (TLA). Compared to TLA, IgG, IgM, and IgA levels to ROP4 VLP antigen were significantly higher in the sera of T. gondii RH-infected mice 1 and 2 week post-infection (PI). T. gondii-specific IgG antibody was detected at 1, 2, 4, and 8 week PI in the T. gondii ME49-infected mice with infection dose-dependent manner. These results indicated that the ROP4 VLP antigen was highly sensitive antigens detecting T. gondii RH and ME49 antibodies at an early stage.

Analytical Quality by Design Methodology Approach for Simultaneous Quantitation of Paeoniflorin and Decursin in Herbal Medicine by RP-HPLC Analysis

  • Kim, Min Kyoung;Park, Geonha;Hong, Seon-Pyo;Jang, Young Pyo
    • Natural Product Sciences
    • /
    • 제27권4호
    • /
    • pp.264-273
    • /
    • 2021
  • Simultaneous quantification of multiple marker compounds in herbal medicine by high performance liquid chromatography (HPLC) analysis is still a challenge due to the complexity in various parameters to be considered and co-existing multi-components. As a case study, a reliable HPLC method for simultaneous quantification of paeoniflorin from Paeoniae Radix and decursin from Angelicae Gigantis Radix in various commercial herbal medicine was developed based on analytical quality by design (AQbD) strategy. As a first step, risk assessment was performed to select the critical method parameters (CMPs) which were decided as organic mobile phase ratio and column oven temperature. In order to evaluate the effect of the CMPs on critical method attributes (CMAs) of peak resolution and tailing, central composite design (CCD) was employed. The final chromatographic conditions were optimized as follows: column- C18, 4.6 × 250 mm, 5 ㎛ particle size; mobile phase- A: acetonitrile, B: 0.1% acetic acid water; detection wavelength- 235 nm for paeoniflorin, 325 nm for decursin; column oven temperature- 25℃; flow rate- 1.0 mL/min; gradient mobile phase system as Time (min) : % A, 0:14, 25:14, 30:50, 60:50, 61:100, 65:100, 66:14, 75:14. The method was successfully validated according to the International Conference on Harmonization (ICH) guidelines and piloted for ten commercial herbal medicines.

Extraction of quasi-static component from vehicle-induced dynamic response using improved variational mode decomposition

  • Zhiwei Chen;Long Zhao;Yigui Zhou;Wen-Yu He;Wei-Xin Ren
    • Smart Structures and Systems
    • /
    • 제31권2호
    • /
    • pp.155-169
    • /
    • 2023
  • The quasi-static component of the moving vehicle-induced dynamic response is promising in damage detection as it is sensitive to bridge damage but insensitive to environmental changes. However, accurate extraction of quasi-static component from the dynamic response is challenging especially when the vehicle velocity is high. This paper proposes an adaptive quasi-static component extraction method based on the modified variational mode decomposition (VMD) algorithm. Firstly the analytical solutions of the frequency components caused by road surface roughness, high-frequency dynamic components controlled by bridge natural frequency and quasi-static components in the vehicle-induced bridge response are derived. Then a modified VMD algorithm based on particle swarm algorithm (PSO) and mutual information entropy (MIE) criterion is proposed to adaptively extract the quasi-static components from the vehicle-induced bridge dynamic response. Numerical simulations and real bridge tests are conducted to demonstrate the feasibility of the proposed extraction method. The results indicate that the improved VMD algorithm could extract the quasi-static component of the vehicle-induced bridge dynamic response with high accuracy in the presence of the road surface roughness and measurement noise.

Evaluation of neutron attenuation properties using helium-4 scintillation detector for dry cask inspection

  • Jihun Moon;Jisu Kim;Heejun Chung;Sung-Woo Kwak;Kyung Taek Lim
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3506-3513
    • /
    • 2023
  • In this paper, we demonstrate the neutron attenuation of dry cask shielding materials using the S670e helium-4 detector manufactured by Arktis Radiation Ltd. In particular, two materials expected to be applied to the TN-32 dry cask manufactured by ORANO Korea and KORAD-21 by the Korea Radioactive Waste Agency (KORAD) were utilized. The measured neutron attenuation was compared with our Monte Carlo N-Particle Transport simulation results, and the difference is given as the root mean square (RMS). For the fast neutron case, a rapid decline in neutron counts was observed as a function of increasing material thickness, exhibiting an exponential relationship. The discrepancy between the experimentally acquired data and simulation results for the fast neutron was maintained within a 2.3% RMS. In contrast, the observed thermal neutron count demonstrated an initial rise, attained a maximum value, and exhibited an exponential decline as a function of increasing thickness. In particular, the discrepancy between the measured and simulated peak locations for thermal neutrons displayed an RMS deviation of approximately 17.3-22.4%. Finally, the results suggest that a minimum thickness of 5 cm for Li-6 is necessary to achieve a sufficiently significant cross-section, effectively capturing incoming thermal neutrons within the dry cask.

Structural and component characterization of the B4C neutron conversion layer deposited by magnetron sputtering

  • Jingtao Zhu;Yang Liu;Jianrong Zhou;Zehua Yang;Hangyu Zhu;Xiaojuan Zhou;Jinhao Tan;Mingqi Cui;Zhijia Sun
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3121-3125
    • /
    • 2023
  • Neutron conversion detectors that use 10B-enriched boron carbide are feasible alternatives to 3He-based detectors. We prepared boron carbide films at micron-scale thickness using direct-current magnetron sputtering. The structural characteristics of natural B4C films, including density, roughness, crystallization, and purity, were analyzed using grazing incidence X-ray reflectivity, X-ray diffraction, X-ray photoelectron spectroscopy, time-of-flight secondary ion mass spectrometry, and scanning electron microscopy. A beam profile test was conducted to verify the practicality of the 10B-enriched B4C neutron conversion layer. A clear profile indicated the high quality of the neutron conversion of the boron carbide layer.

중성자 모니터링을 위한 전도성 10B 박막 개발 (The development of conductive 10B thin film for neutron monitoring)

  • 임창휘;김종열;이수현;정용주;최영현;백철하;문명국
    • Journal of Radiation Protection and Research
    • /
    • 제39권4호
    • /
    • pp.199-205
    • /
    • 2014
  • 중성자 검출분야에서$^3He$는 높은 중성자 검출효율 때문에 아주 많이 사용되고 있다. 하지만 2009년 초반부터 발생하고 있는 전세계적인 $^3He$의 품귀현상으로 인하여 가격이 급등하고 수급이 어려워졌기 때문에 대체 중성자 검출물질에 대한 필요성이 높아졌다. 그러므로 중성자 검출물질로 사용될 수는 있지만 $^3He$에 비해 반응효율이 낮아 중성자 검출용으로 주로 사용되지 않던 물질들을 사용하여 검출기를 제작하는 연구가 다시 활발하게 진행되고 있다. $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$ 등과 같은 $^3He$ 대체 물질들 중 하나인 $^{10}B$은 손쉬운 감마선 구별, 무독성, 낮은 가격 등과 같은 여러 장점으로 인하여 여러 연구그룹에서 연구되고 있다. $^{10}B$ 박막을 이용한 중성자 검출은 중성자와 반응하여 발생되는 2차 방사선을 측정하여 간접적으로 중성자를 측정하는 검출기법이다. 반응을 통해 생성된 알파입자의 비정은 고체 내에서 아주 짧기 때문에 $^{10}B$ 층은 박막 형태로 얇게 제작해야 한다. 그러므로 중성자와 박막의 반응을 통해 발생되는 알파입자의 검출효율을 증가시키기 위해서는 $^{10}B$ 박막의 두께를 얇게 제작하는 것이 중요하다. 하지만 박막의 두께를 얇게 제작하는 것은 중성자와 반응하여 생성되는 알파입자의 수집효율을 증가시키는 장점이 있지만 또한 중성자와 반응할 단면적을 감소시키는 단점이 있다. 본 논문에서는 리튬이온전지에 사용되는 초박막 극판 제조 기술을 이용하여 중성자 검출을 위한 대략 $60{\mu}m$ 두께의 얇은 $^{10}B$ 박막을 제작하였다. 그리고 전도성, 분포, 점착력, 유연성와 같은 간단한 물리적 실험을 통해 제작된 $^{10}B$ 박막의 물성을 확인하였다. 또한, 제작된 $^{10}B$ 박막을 사용하여 중성자 모니터링을 위한 비례계수기 제작하고 이를 이용하여 한국원자력연구원의 중성자 조사시설의 중성자 파고 스펙트럼을 측정하였다. 또한, 중성자 검출효율을 증가시킬 수 있는 방법 중 하나인 다층 박막을 이용한 중성자 측정 방법을 이용하여 박막 층수에 따른 중성자 검출효율의 변화를 몬테칼로 전산모사 기법을 이용하여 계산하였고 실험을 통해 박막층의 증가에 따른 신호변화를 측정하였다.