• 제목/요약/키워드: particle detection

검색결과 310건 처리시간 0.026초

Qualitative and quantitative assessment of process related impurities in Brigatinib raw material and formulations using HPLC

  • Attada Tharun;Potnuru Jagadeesh;B Srinivasa Kumar;Kota Thirumala Prasad;Venkateswara Rao Anna
    • 분석과학
    • /
    • 제36권4호
    • /
    • pp.180-190
    • /
    • 2023
  • The presence of process related impurities in any drug or the drug product was associated with its safety, stability and efficacy. The overall literature survey proved that there is no method published on the assessment of process related impurities in brigatinib. In this study, a simple, reliable and stable HPLC qualitative method was reported for quantification of process related impurities with easy and quick extraction procedure. The impurities along with standard brigatinib was resolved on Lichrospher® C18 (250 mm × 4.6 mm; 5 ㎛ particle size) column in room temperature using methanol, acetonitrile, pH 4.5 phosphate buffer in 55:25:20 (v/v) at 1.0 mL/min as mobile phase and UV detection at 261 nm. The method produces well resolved peaks at retention time of 4.60 min, 12.28 min, 3.37 min, 7.34 min and 8.39 min respectively for brigatinib, impurity A, B, C and D. The method produces a very sensitive detection limit of 0.0065 ㎍/mL, 0.0068 ㎍/mL, 0.0053 ㎍/mL and 0.0058 ㎍/mL for impurity A, B, C and D respectively with calibration curve linear in the concentration range of 22.5-135 ㎍/mL for brigatinib and 0.0225-0.135 ㎍/mL for impurities. The method produces all the validation parameters under the acceptable level and doesn't produces any considerable changes in peak area response while minor changes in the developed method conditions. The method can effectively resolve the unknown stress degradation products along with known impurities with less % degradation. The method can efficiently resolve and quantify the impurities in formulation and hence can suitable for the routine quality analysis of brigatinib in raw material and formulation.

삼겹살과 고등어 조리시 발생하는 나노입자의 시간과 거리에 따른 크기분포와 PAH 검출 (Measurement of Nanoaerosol Size Distributions and PAHs Detection After Cooking)

  • 한정석;우창규;노승렬;배용준;성향기;최만수
    • 한국입자에어로졸학회지
    • /
    • 제7권3호
    • /
    • pp.71-77
    • /
    • 2011
  • Pork belly meat and mackerel are popular meals in Korea. Although a lot of people enjoy cooking these food, there have been some reports that generated organic particles during cooking could be thereas on of lung cancer of nonsmoking housewives. In addition, some experiments show that carcinogens may be included in meat and fishes which we eat usually. For this reason, particle size and concentration in formation during cooking are necessary to figure out the relationship between particles and the diseases. Thus, we identify number concentrations and size distributions of generated nano aerosol in cooking with respect to time, hood operation, and distance between cooking and measurement locations. The maximum concentrations of nano aerosol(diameter sizes are between 10 to 700nm)are decreased after the cooking from $8{\times}10^6{\sharp}/cm^3$ to zeroth order in pork belly meat cooking, and from $3.5{\times}{\times}10^6{\sharp}/cm^3$ to zeroth order in mackerel cooking respectively. When it comes to hood operation during cooking, the detected concentrations of generated aerosols are decreased as in taking flow rate of the hood increases. In cooking pork belly meat, the reduced amount of concentration is about $3{\times}10^6{\sharp}/cm^3$ compared to no hood operation, when hood in taking flow rate is $610m^3/hr$ In mackerel cooking, reduced concentration is $6{\times}10^5{\sharp}/cm^3$ in the same condition. Also, Naphthalene and Fluorene, which are known as polycyclic aromatic hydrocarbons (PAHs), are detected in the generated aerosols during cooking.

자동연속측정시스템 개발 및 이 시스템을 이용한 서울 대기 중 PM2.5의 화학적 조성과 특성에 관한 연구 (Development of an Automated and Continuous Analysis System for PM2.5 and Chemical Characterization of the PM2.5 in the Atmosphere at Seoul)

  • 이보경;김영훈;하재윤;이동수
    • 한국대기환경학회지
    • /
    • 제21권4호
    • /
    • pp.439-458
    • /
    • 2005
  • An automated analysis system for water soluble constituents in $PM_{2.5}$ has been developed. The system consists of a high capacity multi tube diffusion scrubber (MTDS), a low temperature particle impactor (LTPI), and two ion (anion and cation) chromatography (IC) systems. Atmospheric particles have been collected by passing sample air through a thermostated MTDS followed by a LTPI. This system allows simultaneous measurements of soluble ions in $PM_{2.5}$ at 30 minutes interval. At the air sampling flow rate of 1.0L/min, the detection limits of the overall system are in the order of tens of $ng/m^3$. This system has been successfully used for the measurement of particulate components of Seoul air from April 2003 to January 2004. $SO_4^{2-},\;NO_3^-,\;NH_4^+,\;NO_2^-,\;Cl^-,\;Na^+,\;K^+,\;Ca^{2+},\;and\;Mg^{2+}$ are the major ionic species for $PM_{2.5}$ at Seoul. Among them, $SO_4^{2-},\;NO_3^-\;and\;NH_4^+$ are the most abundant ions, contributed up to $86\%$ of the total and the concentrations were higher than those in any other urban sites in the world except for Chinese cities. There are high pollutant episodes which contribute about $15\~20\%$ of annual average values of the major ions. During the episode, the all parcels were transported from the asian continent and $PM_{2.5}$ were significantly neutralized. This suggests that aged and long range transported pollutants caused the high pollutant episodes. They showed a distinct daily and seasonal variations:they showed a peak in the early morning caused by the night-time accumulation of particulate matters. Atmospheric reactions including gas-to-particle reactions and inter-particle reactions and meteorological parameters including relative humidity and ambient temperature were described with related to the $PM_{2.5}$ 5 concentrations. All of the ionic species showed higher concentrations during the spring than those for summer and winter.

An OTHBVS Cell Line Expresses the Human HBV Middle S Protein

  • Park, Sung-Gyoo;Guhung Jung
    • Journal of Microbiology
    • /
    • 제37권2호
    • /
    • pp.86-89
    • /
    • 1999
  • An OTHBVS cell line from HepG2 was established. This cell line stably expresses the human hepatitis B virus (HBV) middle S protein that includes the preS2 region which is important for HBV particle entry into the hepatocyte. To establish this cell line, the middle S open reading frame (ORF), with a promoter located in the 5' region and enhancer located in the 3' region, was cloned downstream from the metallothionine (MT) promoter of the OT1529 vector. In this vector, expression of the middle S protein was constructed to be regulated by its own promoter and enhancer. Expression of the large S protein which contains the preS1 region in addition to the middle S protein was designed to be regulated by the MT promoter. When extracts of OTHBVS cells were examined with an S protein detection kit (RPHA, Korea Green Cross Co.), an S protein was detected. Total mRNA of OTHBVS cell examined by northern blot analysis with an S ORF probe revealed small/middle S transcripts (2.1 kb). When the MT promoter was induced by Zn, large S transcripts (2.4 kb) were detected. The GP36 and GP33 middle S proteins were presumably detected, but large S proteins were not detected by immunostain analysis using anti-preS2 antibody.

  • PDF

Fabrication and Simulation of Fluid Wing Structure for Microfluidic Blood Plasma Separation

  • Choe, Jeongun;Park, Jiyun;Lee, Jihye;Yeo, Jong-Souk
    • Applied Science and Convergence Technology
    • /
    • 제24권5호
    • /
    • pp.196-202
    • /
    • 2015
  • Human blood consists of 55% of plasma and 45% of blood cells such as white blood cell (WBC) and red blood cell (RBC). In plasma, there are many kinds of promising biomarkers, which can be used for the diagnosis of various diseases and biological analysis. For diagnostic tools such as a lab-on-a-chip (LOC), blood plasma separation is a fundamental step for accomplishing a high performance in the detection of a disease. Highly efficient separators can increase the sensitivity and selectivity of biosensors and reduce diagnostic time. In order to achieve a higher yield in blood plasma separation, we propose a novel fluid wing structure that is optimized by COMSOL simulations by varying the fluidic channel width and the angle of the bifurcation. The fluid wing structure is inspired by the inertial particle separator system in helicopters where sand particles are prevented from following the air flow to an engine. The structure is ameliorated in order to satisfy biological and fluidic requirements at the micro scale to achieve high plasma yield and separation efficiency. In this study, we fabricated the fluid wing structure for the efficient microfluidic blood plasma separation. The high plasma yield of 67% is achieved with a channel width of $20{\mu}m$ in the fabricated fluidic chip and the result was not affected by the angle of the bifurcation.

분진을 이용한 연기감지기 신뢰성 분석에 관한 연구 (A Study on the Reliability Analysis for Smoke Detector using Dust)

  • 홍성호;최문수;이영만
    • 한국안전학회지
    • /
    • 제28권6호
    • /
    • pp.11-16
    • /
    • 2013
  • This paper presents a study on the analyzing reliability of smoke fire detector using accelerated life test. In general, the smoke fire detector is broken by dust which flow in smoke detection chamber. In order to conduct accelerated life test of smoke fire detector dust is set accelerated factor in this paper. The dust is fly-ash which is test particle 5th regulated by KS A 0090. The dust accelerated level is 60 g, 180 g and 360 g and failure time is measured by smoke sensitivity testing. It is considered to failure of detector if detector don't operate within 30 secconds when subjected to an air stream having a velocity of 20 cm/s~40 cm/s containing smoke with a concentration of 15% of rate of light-response of 1 m. The goodness of fit test and mean life prediction conduct using the failure time. The result show that life distribution fits the weibull distribution for failure time data and the mean lifes calculate 22.5 year in domestic product and 14.7 years in overseas product applied dust stress only.

LCD 패널 Review & Repair 장비의 결함수정 자동화 알고리즘 (Auto Defect Repair Algorithm for LCD Panel Review & Repair Machine)

  • 이우철;임성묵;이승기;정수화;홍순국
    • 한국레이저가공학회지
    • /
    • 제15권1호
    • /
    • pp.6-9
    • /
    • 2012
  • In TFT-LCD manufacturing process, various defects are generated by manufacturing machine trouble or particle. These defects can be repaired through the TFT-Laser repair process that only can't be automated in TFT-LCD manufacturing Process. In this Paper, we propose auto defect algorithm for TFT-LCD laser repair machine using image processing algorithm in order to automate process. Proposed algorithm can detect very small defects (< 2um) in 98% success ratio, and generated laser repair path guarantee highly precise position accuracy. Through proposed system, much of the work still done the old-fashioned way, by hand, can be automated and manufacturing company can be strengthed the competitiveness of cost.

  • PDF

초음파에 의한 필렛 용접힐부의 표면결함 검출능에 관한 실험적 검증 (Experimental Verification on the Detectability of Surface Flaws at Fillet Weld Hills by Ultrasonic Method)

  • 박익근;이철구
    • Journal of Welding and Joining
    • /
    • 제18권1호
    • /
    • pp.46-51
    • /
    • 2000
  • Ultrasonic nondestructive evaluation (UNDE) technique is commonly used for detecting inner defects in the materials. Recently, new methods are trying to apply for detecting surface and subsurface flaws using Rayleigh wave or creeping wave. These techniques, however, have following problems. Echo amplitude is remarkably affected by the surface conditions and discrimination of echo pattern is usually difficult because shear wave propagate in the material at the same time. We can apply surface SH-wave(which is horizontally polarized shear wave traveling along near surface layer) technique to detect surface flaws. In this paper, directivity, distance amplitude characteristics and detectability of surface flaws at fillet weld hills of the 5 MHz and 2 MHz surface flaws at fillet weld hills of the 5 MHz and 2 MHz surface Sh-wave are experimentally investigated. As a result of the study, it was found out that these techniques are valuable for the detection of fatigue cracks at fillet weld heels which can not be detected by other ultrasonic techniques such as angle beam technique and which are inaccessible for non-destructive testings e.g. MT(magnetic particle testing) or PT(liquid penetrant testing).

  • PDF

NEAR-INFRARED PAH FEATURES IN GALACTIC PLANETARY NEBULAE

  • Ohsawa, R.;Onaka, O.;Sakon, I.;Mori, T. I.;Kaneda, H.;Matsuura, M.
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.87-91
    • /
    • 2017
  • Polycyclic aromatic hydrocarbons (PAHs) are considered to be carriers of the unidentified infrared bands, which are ubiquitously observed in the Universe. PAHs are mainly formed around evolved carbon-rich stars and injected into interstellar space. Planetary nebulae (PNe), a late stage of low- and intermediate stellar mass evolution, are suitable objects to investigate the formation and evolution of PAHs. The shortest PAH feature is located in $3.3{\mu}m$, which is important to examine the excitation and size distribution of PAHs. While the number of samples had been limited before, the high sensitivity of AKARI /IRC has drastically increased the number of samples. We obtained the $2-5{\mu}m$ spectra of Galactic PNe with AKARI /IRC and compiled a near-infrared spectral catalog, containing 73 PNe. We investigate the detection rate and the evolution of the PAH features. The characteristics of the catalog are illustrated and the origin of the evolution of the PAH features is discussed.

RP-HPLC를 이용한 혈액에 포함된 펩타이드의 분리 (Isolation of Peptides from Human Blood by RP-HPLC)

  • 노경호;이승기
    • KSBB Journal
    • /
    • 제17권3호
    • /
    • pp.261-265
    • /
    • 2002
  • 생리활성을 가지는 펩타이드에 관한 연구는 각종 질환의 진단, 예방 및 치료약으로서의 응용 가능성이 매우 높아서 현재 많은 연구가 진행 중이다. 펩타이드를 RP-HPLC에 의해 정량, 정성분석 함으로 다양한 연구 분야로의 확대를 모색해 볼 수 있다. 혈액 속에 있는 적혈구내의 펩타이드를 분리하기 위해 0.75% TFA가 포함된 물과 아세토나이트릴을 이동상과 선형적 구배용매 조성을 이용한 실험결과, 펩타이드의 peak 분리도는 상당히 우수하였다. 혈액을 채취한 날짜의 경과에 따라서 새로운 생리활성 물질이 만들어짐을 확인할 수 있었다. 이와 같은 현상은 적혈구내의 세포들이 산소를 계속적으로 소비함으로써 산소 부족현상 때문에 발생하는 것으로 알려져 있고 구조적 변화를 나타내는 생리활성 펩타이드를 정성적으로 확인함으로써 좀더 의학적인 분야로의 연구를 수 행할 수 있게 될 것이다.