• 제목/요약/키워드: particle detection

검색결과 321건 처리시간 0.029초

Simultaneous Measurements of Gaseous Nitrous Acid and Particulate Nitrite Using Diffusion Scrubber/Steam Chamber/Luminol Chemiluminescence

  • Chang, Won-Il;Choi, Jung-Ho;Hong, Sang-Bum;Lee, Jai H.
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권8호
    • /
    • pp.1525-1532
    • /
    • 2008
  • An instrument was developed for the simultaneous determination of gas- and aerosol-phase nitrous acid (HONO). Gaseous HONO (HONO(g)) was sampled by a diffusion scrubber and particulate nitrite ($NO_2\;^-$(p)) was collected by a particle growth chamber. The collected samples were analyzed in time-sharing manner, based on the peroxynitrite-induced luminol chemiluminescence. The automated system was found to be sensitive with 13 pptv of detection limit, fast with 4 min. of sampling frequency, and simple and affordable to construct and operate. The system was optimized by adjusting the experimental parameters. The system was applied to the field measurement of gas- and particle-phase HONO during the springtime of 2004 in Gwangju, South Korea. HONO(g) concentrations varied diurnally from 200 pptv around 3 P.M. to 800 pptv at 5 A.M. The variation of $NO_2\;^-$(p) was not significant with the maximum of 240 pptv at 11 P.M. and the minimum of 170 pptv at 4 P.M., not displaying distinct characteristics.

Mini Neutron Monitors at Concordia Research Station, Central Antarctica

  • Poluianov, Stepan;Usoskin, Ilya;Mishev, Alexander;Moraal, Harm;Kruger, Helena;Casasanta, Giampietro;Traversi, Rita;Udisti, Roberto
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권4호
    • /
    • pp.281-287
    • /
    • 2015
  • Two mini neutron monitors are installed at Concordia research station (Dome C, Central Antarctica, $75^{\circ}06^{\prime}S$, $123^{\circ}23^{\prime}E$, 3,233 m.a.s.l.). The site has unique properties ideal for cosmic ray measurements, especially for the detection of solar energetic particles: very low cutoff rigidity < 0.01 GV, high elevation and poleward asymptotic acceptance cones pointing to geographical latitudes > $75^{\circ}S$. The instruments consist of a standard neutron monitor and a "bare" (lead-free) neutron monitor. The instrument operation started in mid-January 2015. The barometric correction coefficients were computed for the period from 1 February to 31 July 2015. Several interesting events, including two notable Forbush decreases on 17 March 2015 and 22 June 2015, and a solar particle event of 29 October 2015 were registered. The data sets are available at cosmicrays.oulu.fi and nmdb.eu.

알파입자 부식-새김을 이용한 PN-3 선량측정기의 특성 (Characteristics of Track-Etch PN-3 Dosimeters for Alpha Particles)

  • Yoo, Done-Sik
    • 한국의학물리학회지:의학물리
    • /
    • 제1권1호
    • /
    • pp.97-107
    • /
    • 1990
  • 본 논문에서는 플라스틱 검출기의 일종인 알릴 다이글리콜 카보네이트 물질 (PN-3) 에서의 하전입자의 검출 방법과 여러장의 흡수체를 통과하여 얻어진 알파 업자의 에너지 (3.17~5.49 MeV) 에 대한 알파입자 궤적의 특성을 논의하였다. 또한 등가흡수선량율을 계산하였고, 일파입자의 도달거리를 특정하기위해 섬광계수기를 사용하였다. PN-3 의 에칭특성과 검출 특성등이 여러가지 변수들로 표현되었다. 즉, 부식당한 입자궤적의 길이가 갖는 각각의 알파입자 에너지에대한 연관성등을 논의하였다. PN-3 플라스틱 선량 검출기에 기록된 알 파업자의 에칭과정에서 매우 흥미있는 결과를 얻었다.

  • PDF

GPS Integrity Monitoring Method Using Auxiliary Nonlinear Filters with Log Likelihood Ratio Test Approach

  • Ahn, Jong-Sun;Rosihan, Rosihan;Won, Dae-Hee;Lee, Young-Jae;Nam, Gi-Wook;Heo, Moon-Beom;Sung, Sang-Kyung
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권4호
    • /
    • pp.563-572
    • /
    • 2011
  • Reliability is an essential factor in a navigation system. Therefore, an integrity monitoring system is considered one of the most important parts in an avionic navigation system. A fault due to systematic malfunctioning definitely requires integrity reinforcement through systematic analysis. In this paper, we propose a method to detect faults of the GPS signal by using a distributed nonlinear filter based probability test. In order to detect faults, consistency is examined through a likelihood ratio between the main and auxiliary particle filters (PFs). Specifically, the main PF which includes all the measurements and the auxiliary PFs which only do partial measurements are used in the process of consistency testing. Through GPS measurement and the application of the autonomous integrity monitoring system, the current study illustrates the performance of the proposed fault detection algorithm.

A Detection of Airborne Particles Carrying Viable Bacteria in an Urban Atmosphere of Japan

  • Hara, Kazutaka;Zhang, Daizhou;Yamada, Maromu;Matsusaki, Hiromi;Arizono, Koji
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권3호
    • /
    • pp.152-156
    • /
    • 2011
  • Viable bacteria on water-insoluble airborne particles were detected in the urban atmosphere of Kumamoto ($134^{\circ}45'E$, $32^{\circ}28'N$), Japan, in autumn 2008. Airborne particles were collected onto film-covered Cu meshes under clear weather conditions. The samples were stained by fluorescent stains, and then viewed and photographed with an epifluorescent microscope. Non-biological and bacterial parts in particles larger than 0.8 ${\mu}m$ were distinguished by their morphologies, fluorescent colors and fluorescent intensities. Bacterial viable statuses were discriminated according to cell membrane damage. In total, 2681 particles were investigated and it was found that 78 airborne particles were associated with bacteria. Viable bacteria were identified on 48 particles. A few particles carried multiple viable bacteria. These results provide the evidence that airborne particles act as carriers of viable bacteria in the atmosphere.

A New Multiplex-PCR for Urinary Tract Pathogen Detection Using Primer Design Based on an Evolutionary Computation Method

  • Garcia, Liliana Torcoroma;Cristancho, Laura Maritza;Vera, Erika Patricia;Begambre, Oscar
    • Journal of Microbiology and Biotechnology
    • /
    • 제25권10호
    • /
    • pp.1714-1727
    • /
    • 2015
  • This work describes a new strategy for optimal design of Multiplex-PCR primer sequences. The process is based on the Particle Swarm Optimization-Simplex algorithm (Mult-PSOS). Diverging from previous solutions centered on heuristic tools, the Mult-PSOS is selfconfigured because it does not require the definition of the algorithm's initial search parameters. The successful performance of this method was validated in vitro using Multiplex-PCR assays. For this validation, seven gene sequences of the most prevalent bacteria implicated in urinary tract infections were taken as DNA targets. The in vitro tests confirmed the good performance of the Mult-PSOS, with respect to infectious disease diagnosis, in the rapid and efficient selection of the optimal oligonucleotide sequences for Multiplex-PCRs. The predicted sequences allowed the adequate amplification of all amplicons in a single step (with the correct amount of DNA template and primers), reducing significantly the need for trial and error experiments. In addition, owing to its independence from the initial selection of the heuristic constants, the Mult-PSOS can be employed by non-expert users in computational techniques or in primer design problems.

LIIM(Laser-Induced Ion Mobility) 계측을 이용한 매연 나노입자 측정 (Measurement of Soot Nano-Particle Using LIIM(Laser-Induced Ion Mobility))

  • 이의주
    • 대한기계학회논문집B
    • /
    • 제28권9호
    • /
    • pp.1110-1116
    • /
    • 2004
  • Experimental measurements of laser-induced ion mobility(LIIM) were performed for ethene/air premixed flames operated near the soot inception point. Soot was ionized using a pulsed laser operated at 532 nm. The ionization signal was collected with a tungsten electrode located in the post-flame region. ionization signals were collected using both a single electrode and dual electrode configuration. Prior LIIM studies have focused on the use of a single biased electrode to generate the electric field, with the burner head serving as the path to ground. In many practical combustion systems, a path to ground is not readily available. To apply the LIIM diagnostic to these geometries, a dual electrode geometry must be employed. The influence of electrode configuration, flame equivalence ratio, and flame height on ionization signal detection was determined. The efficacy of the LIIM diagnostic to detect soot inception in the post-flame region of a premixed flame using a dual electrode configuration was investigated. For the different dual electrode configurations tested, the dual parallel electrode geometry was observed to be most sensitive to detect the soot inception point in a premixed flame.

Effects of Preparation Method and Evaluations on Structural Integrity in Model Antigen-Containing Biodegradable Microspheres for Vaccine Delivery

  • Cho Seong-Wan;Kim Young-Kwon
    • 대한의생명과학회지
    • /
    • 제12권3호
    • /
    • pp.177-183
    • /
    • 2006
  • To demonstrate the effect of formulation conditions and evaluations of structural integrity from ovalbumin containing poly lactide glycolide copolymer (PLGA) microspheres for Vaccine delivery, OVA microspheres were prepared by a W/O/W multiple emulsion solvent extraction technique. Dichloromethan (DCM) and Ethyl acetate (EA) were applied as an organic phase and poly vinyl alcohol (PVA) as a secondary emulsion stabilizer. Microspheres were characterized for particle size, morphology (optical microscopy and Scanning Electron Microscope (SEM)). Protein denaturation was evaluated by size exclusion chromatography (SEC), SDS-PAGE and isoelectric focusing (IEF). Residual organic solvent was estimated by gas chromatography (GC) and differential scanning calorimetry (DSC). Optical photomicrograph and SEM revealed that micro spheres were typically spherical but various morphologies were observed. Mean particle size $(d_{vs})$ of microspheres were in the range of $3{\sim}50{\mu}m$. Also, The protein stability was not affected by the fonnulation process and residual organic solvent was beyond the detection below 0.1ppm. These results demonstrated that micro spheres might be a good candidate for the parenteral vaccine delivery system.

  • PDF

Optical Tracking of Three-Dimensional Brownian Motion of Nanoparticles

  • Choi C. K.;Kihm K.D.
    • 한국가시화정보학회지
    • /
    • 제3권1호
    • /
    • pp.3-19
    • /
    • 2005
  • Novel optical techniques are presented for three-dimensional tracking of nanoparticles; Optical Serial Sectioning Microscopy (OSSM) and Ratiometric Total Internal Reflection Fluorescent Microscopy (R-TIRFM). OSSM measures optically diffracted particle images, the so-called Point Spread Function (PSF), and dotermines the defocusing or line-of-sight location of the imaged particle measured from the focal plane. The line-of-sight Brownian motion detection using the OSSM technique is proposed in lieu of the more cumbersome two-dimensional Brownian motion tracking on the imaging plane as a potentially more effective tool to nonintrusively map the temperature fields for nanoparticle suspension fluids. On the other hand, R-TIRFM is presented to experimentally examine the classic theory on the near-wall hindered Brownian diffusive motion. An evanescent wave field from the total internal reflection of a 488-nm bandwidth of an argon-ion laser is used to provide a thin illumination field of an order of a few hundred nanometers from the wall. The experimental results show good agreement with the lateral hindrance theory, but show discrepancies from the normal hindrance theory. It is conjectured that the discrepancies can be attributed to the additional hindering effects, including electrostatic and electro-osmotic interactions between the negatively charged tracer particles and the glass surface.

  • PDF

결절법을 이용한 전영역에서의 연기입자 응집체에 대한 브라운응집현상 해석 (Simulation of the Brownian Coagulation of Smoke Agglomerates in the Entire Size Regime using a Nodal Method)

  • 구재학
    • 한국대기환경학회지
    • /
    • 제27권6호
    • /
    • pp.681-691
    • /
    • 2011
  • The size distributions of smoke particles from fire are prerequisite for the studies on fire detection and adverse health effects. Above the flame of the fire, coagulation dominates and the smoke particles grow from 1 to 50 nm up to 100 to 3,000 nm, sizes ranging from the free-molecular regime to the continuum regime. The characteristics of the agglomeration of the smoke particles are well known, independently for each of the free-molecular and continuum regimes. However, there are not many systematic studies in the entire regime by the complexity of the mechanisms. The purpose of this work is to find the characteristics of the development of the size distribution of smoke particles by agglomeration in the entire size range covering the free-molecular regime, via transition regime, to the near-continuum and continuum regime for each variation of parameters such as fractal dimension, primary particle size and dimensionless coagulation time. In this work, the dynamic equation for the discrete-size spectrum of the particles was solved using a nodal method based on the modification of a sectional method. In the calculation, the collision frequency function for the entire regime, which is derived by using the concept of collision volume and general enhancement function, was applied. The self-preserving size distribution for the entire regime is compared with the ones for the free-molecular or continuum regimes for each variation of the parameters.