• Title/Summary/Keyword: particle deposition

Search Result 570, Processing Time 0.034 seconds

Estimating Critical Stream Power by the Distribution of Gravel-bed Materials in the Meandering River (만곡하천의 자갈하상재료 분포에 따른 한계수류력 평가)

  • Shin, Seung-Sook;Park, Sang-Deok;Lee, Seung-Kyu;Ji, Min-Gyu
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.2
    • /
    • pp.151-163
    • /
    • 2012
  • The distribution of gravel-bed materials in mountainous river is formed by the process of deposition and transportation of sediment responding to stream power of the latest flood that is over the certain scale. The particle size of bed material was surveyed in the longitudinal points of river and detail points of a specific meandering section and used to estimate the critical velocity and stream power. Yang's critical unit stream power and Bagnold's critical stream power for gravel-bed materials increased with the distance from downstream to upstream. Dimensionless shear stress based on the designed flood discharge in Shields diagram was evaluated that the gravel-bed materials in most survey points may be transported as form of bedload. The mean diameter in the meandering section was the biggest size in first water impingement point of inflow water from upstream and the second big size in second water impingement point by reflection flow. The mean diameters were relatively the small sizes in points right after water impingement. The range of mean critical velocity was 0.77~2.60 m/s and critical unit stream power was big greatly in first water impingement point. The distribution of critical stream power, range of 7~171 $W/m^2$, was shown that variation in longitudinal section was more obvious than that of cross section and estimated that critical stream power may be affected greatly in first and second water impingement point.

The effects of solenoid magnet on plasma extraction in Filtered Vacuum Arc Source (FVAS) (자장여과 아크 소스에서 각 전자석이 플라즈마 인출에 미치는 영향)

  • 김종국;변응선;이구현;조영상
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.431-439
    • /
    • 2001
  • In this paper, the a-Diamond films were synthesized using filtered vacuum arc source (FVAS), FVAS was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were composed of one permanent magnet and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Cathode was made of graphite with 80 mm in diameter. The effects of solenoid magnet on plasma extraction were investigated by computer simulation and experiment using Taguchi's methode. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. The beam current density was 3.2 mA/$\textrm{cm}^2$ and average deposition rate was 5 $\AA$/sec when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, 5 A, and 5 A, respectively. The beam current density and the efficiency of beam transportation were increased with the positive bias voltage of the plasma duct.

  • PDF

Comparison of Utrasonic and Vibration Diagnostic Techniques for the Inspection of Pipes in CVD System (화학증착 시스템에서의 파이프내 오염입자 관찰을 위한 초음파 및 진동 진단법의 비교연구)

  • Yun Ju-Young;Seong Dae-Jin;Shin Yong-Hyoen;Lee Ji-Hun;Moon Doo-Kyung;Kang Sang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.421-426
    • /
    • 2006
  • In examining particulate deposits in the pipes of a chemical vapor deposition (CVD) system, vibration diagnostics is compared and studied against ultrasonic diagnostics, The latter method involves pulsing the outer wall of pipes with an ultrasonic sensor and analyzing the resulting echo to observe particulate deposits inside pipes. Vibration diagnostics examines the existence of particulate deposits by analyzing the difference in the frequencies generated when a vibrator is adhered to the outer wall of pipes. With ultrasonic diagnostics, good test results were obtained only when particulate deposits were attached to the inner wall of the pipes, After some time, however, particulate deposits were not detected properly, as the ultrasonic wave failed to cross the fine gaps created between the inner wall of the pipe and the deposits. The ultrasonic wave bounced back because of the dried particulate deposits on the wall. Thus, it has been proven that the ultrasonic diagnostics is not an appropriate means of examining the particulate deposits in a vacuum, On the other hand, vibration diagnostics succeeded in detecting the particulate deposits regardless of the lapsed time. In conclusion, the vibration diagnostics is being expected as the effective method in monitoring the particulate deposits inside pipes in the CVD system where the desired behavior is reduced frequency along with the particulate deposits in comparison to the case where the pipe is clean.

A Case Analysis of Volcanic Ash Dispersion under Various Volcanic Explosivity Index of the Mt. Baegdu (백두산 분화 강도에 따른 화산재 확산 사례 분석)

  • Lee, Soon-Hwan;Jang, Eun-Suk;Lee, Hyun-Mi
    • Journal of the Korean earth science society
    • /
    • v.33 no.3
    • /
    • pp.280-293
    • /
    • 2012
  • In order to clarify the characteristics of dispersion of volcanic tephra emitted from the Mt. Baegdu with various eruption environment, numerical analysis were performed using numerical models, Weather Research and Forecast (WRF) and FLEXPART. Synoptic conditions at 12 October 2010 was adopted because the volcanic ash of Mt. Baegdu can reach the Korean peninsula and its dispersion pattern was compared with different Volcanic Explosivity Index (VEI) and particle size. Predominant size of falling out ash flowing in the peninsular is smaller than 0.5 mm and the ash large than the size is difficult to get in the peninsular due to the its weak ability of truculent diffusion. the difference of ash distribution with various VEI scenarios is not so much but number density of ash in the air is dramatically changed. Volcanic ash tends to be deposited easily in eastern coastal area such as Gangneung and Busan, because of the inflow of ash from East Sea and barrier effect of the Taeback mountains along the east coast of the Korean Peninsula. Accumulated amount of ash deposition can be increased in short period in several urban areas.

A STUDY ON THE RESPONSES OF OSTEOBLASTS TO VARIOUS SURFACE-TREATED TITANIUM

  • Lee Joung-Min;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.3
    • /
    • pp.307-326
    • /
    • 2004
  • Statement of problem. The long-term success of implants is the development of a stable direct connection between bone and implant surface, which must be structural and functional. To improve a direct implant fixation to the bone, various strategies have been developed focusing on the surface of materials. Among them, altering the surface properties can modify cellular responses such as cell adhesion, cell motility and bone deposition. Purpose. This study was to evaluate the cellular behaviors on the surface-modified titanium by morphological observation, cellular proliferation and differentiation. Material and methods. Specimens were divided into five groups, depending on their surface treatment: electropolishing(EP) anoclizing(AN), machining(MA), blasting with hydroxyapatite particle(RBM) and electrical discharge machining(EDM). Physicochemical properties and microstructures of the specimens were examined and the responses of osteoblast-like cells were investigated. The microtopography of specimens was observed by scanning electron microscopy(SEM). Surface roughness was measured by a three-dimensional roughness measuring system. The microstructure was analyzed by X-ray diffractometer(XRD) and scanning auger electron microscopy(AES). To evaluate cellular responses to modified titanium surfaces, osteoblasts isolated from neonatal rat were cultured. The cellular morphology and total protein amounts of osteoblast-like cell were taken as the marker for cellular proliferation, while the expression of alkaline phosphatase was used as the early differentiation marker for osteoblast. In addition, the type I collagen production was determined to be a reliable indicator of bone matrix synthesis. Results. 1. Each prepared specimen showed specific microtopography at SEM examination. The RBM group had a rough and irregular pattern with reticulated appearance. The EDM-treated surface had evident cracks and was heterogeneous consisting of broad sheet or plate with smooth edges and clusters of small grains, deep pores or craters. 2. Surface roughness values were, from the lowest to the highest, electropolished group, anodized group, machined group, RBM group and EDM group. 3. All groups showed amorphous structures. Especially anodized group was found to have increased surface oxide thickness and EDM group had titaniumcarbide(TiC) structure. 4. Cells on electropolished, anodized and machined surfaces developed flattened cell shape and cells on RBM appeared spherical and EDM showed both. After 14 days, the cells cultured from all groups were formed to be confluent and exhibited multilayer proliferation, often overlapped or stratified. 5. Total protein amounts were formed to be quite similar among all the group at 48 hours. At 14 days, the electropolished group and the anodized group induced more total protein amount than the RBM group(P<.05). 6. There was no significant difference among five groups for alkaline phosphatase(ALP) activity at 48 hours. The AN group showed significantly higher ALP activity than any other groups at 14 days(P<.05). 7. All the groups showed similar collagen synthesis except the EDM group. The amount of collagen on the electropolished and anodized surfaces were higher than that on the EDM surface(P<.05).

Reconstruction of Changes in Eolian Particle Deposition Across the Mid-Pleistocene Transition in the Central Part of the North Pacific (중기 플라이스토세 전이기 전후 북태평양 중앙 해역 퇴적물에 기록된 풍성 퇴적물 입자 퇴적 양상 변화 복원)

  • Lee, Sojung;Seo, Inah;Hyeong, Kiseong
    • Ocean and Polar Research
    • /
    • v.41 no.4
    • /
    • pp.275-288
    • /
    • 2019
  • We investigated flux, grain size distribution, Nd-Sr isotope composition, mineral composition, and trace metal composition (REEs and Sc) of inorganic silicate fraction (ISF, mainly Asian dust with an unrestricted amount of volcanic materials) deposited during 600~1000 ka across the Mid-Pleistocene Transition at core NPGP 1401-2A (32°01'N, 178°59'E, 5205m) taken from the central part of the North Pacific. Our results reveal about a 2-fold increase in ISF flux after 800 ka, which is associated with an increase in La/Sc and a decrease in mean grain size. Asian dusts are finer than volcanic materials and La/Sc increases with the enhanced contribution of Asian dusts. Thus, increased flux after 800 ka can be explained by the increased contribution of Asian dusts relative to volcanic materials, likely due to an intensified Westerly Jet (WJ) and the drying of the Asian continent after the MPT. Mean grain size of ISF varies systematically in relation to glacial-interglacial cycles with a decrease during glacial stages, which is consistent with the previous results in the study area. Such a cyclical pattern is also attributed to the increase in the relative contribution of Asian dusts over volcanic components in glacial stages due to intensified WJ and drying of the Asian continent. Thus, it can be concluded that climate changes that had occurred across the MPT were similar to those of interglacial to glacial transitions at least in terms of the dust budget. Different from the Shatsky Rise, however, compositional changes associated with glacial-interglacial mean grain size fluctuations are not observed in Nd-Sr isotope ratios and trace element composition in our study of the Hess Rise. This may be attributed to the location of the study site far (> 4,000 km) from the volcanic sources. The volcanic component at the study site comprises less than 10% and varies within 3% over glacial-interglacial cycles. Such a small variation was not enough to imprint geochemical signals.

Evaluation of the Secondary Particle Effect in Inhomogeneous Media for Proton Therapy Using Geant4 Based MC Simulation (Geant4 몬테칼로 시뮬레이션을 활용한 불균질 매질에서의 양성자의 이차입자 영향 분석)

  • Park, So-Hyun;Jung, Won-Gyun;Rah, Jeong-Eun;Park, Sung-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.311-322
    • /
    • 2010
  • In proton therapy, the analysis of secondary particles is important due to delivered dose outside the target volume and thus increased potential risk for the development of secondary cancer. The purpose of this study is to analyze the influence of secondary particles from proton beams on fluence and energy deposition in the presence of inhomogeneous material by using Geant4 simulation toolkit. The inhomogeneity was modeled with the condition that the adipose tissue, bone and lung equivalent slab with thickness of 2 cm were inserted at 30% (Plateau region) and 80% (Bragg peak region) dose points of maximum dose in Bragg curve. The energy of proton was varied with 100, 130, 160 and 190 MeV for energy dependency. The results for secondary particles were presented for the fluence and deposited energy of secondary particles at inhomogeneous condition. Our study demonstrates that the fluence of secondary particles is neither influenced insertion of inhomogeneties nor the energy of initial proton, while there is a little effect by material density. The deposited energy of secondary particles has a difference in the position placed inhomogeneous materials. In the Plateau region, deposited energy of secondary particles mostly depends on the density of inserted materials. Deposited energy in the Bragg region, in otherwise, is influenced by both density of inserted material and initial energy of proton beams. Our results suggest a possibility of prediction about the distribution of secondary particles within complex heterogeneity.

A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector (고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.487-494
    • /
    • 2020
  • The distance between the source and the detector, the diameter of the detector, and the volume effect of the radiation source result in a change in solid angle at the detector entrance, which affects the determination of detection efficiency by causing a difference in path length within the detector. A typical analysis method for calculating solid angles was useful only for a source (60Co) with a simple geometric structure, so in this experiment, the distance between the detector and the source was measured by switching on for up to 25 cm with the reference point of window cap 0.5 cm. In addition, 450 and 1000 ㎖ Marinelli beaker of standard volumetric sources were closely adhered to the detector. For circular point sources co-axial with the detector, the change in the solid angle to the distance from the detector window is equal to half the square radius of the source versus the square radius of the detector, if the resulting relationship of the calculation analysis results in the detector being less than the radius of the source. Since the solid angular difference is 0.5 the result of Monte Carlo is acceptable. The relationship between detector and source distance is shown. Solid angles have been verified to decrease rapidly with distance. Measurement and simulation results for a volumetric source show a difference of ±1.01% from a distance of 0 cm and less than 4 % when the distance is reduced to 5 and 10 cm. It can be seen that the longer distance, the smaller efficiency angle, and the exponential increase in attenuation as the energy decreases, is reflected in the calculation of efficiency. Thus, the detection efficiency has proved sufficient for the use of solid angle and Monte Carlo codes.

Comparison of Lung Ventilation Scan Using Technegas and $^{99m}Tc-DTPA$ Aerosol (Technegas 환기스캔과 $^{99m}Tc-DTPA$ Aerosol 스캔의 비교)

  • Choi, Yoon-Ho;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Keun-Youl;Koh, Chang-Soon;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.237-243
    • /
    • 1990
  • Pulmonary embolism demands rapid and accurate diagnosis. And ventilation imaging has greatly improved the diagnostic accuracy of pulmonary embolism in addition to perfusion imaging. Agents currently used include xenon-133, krypton-81m and technetium-99m radioaerosols. However radioactive gases are compromised by availability and cost for krypton-81m, radiation dose, gamma energy and non?physiologic behaviour for xenon-133. Radioaerosols of technetium-99m componds are rapidly cleared from the lung after inhalation, and their relative low effeciency (specific radioactivity) and wide distribution of particle sizes make them also suboptimum. A new ventilation agent, Technegas is a suspension of structured graphite ellipsoids with diameter below 20nm, labelled with $^{99m}Tc$ in a carrier gas of Argon. This report describes the authors' clinical experience with Technegas. This is the first reported clinical study of this agent in Korea. A comparison of Technegas and $^{99m}Tc-DTPA$ aerosol was performed in 12 patients with various pulmonary diseases such as COPD, pulmonary tuberculosis and pleural effusion. All patients were studied with $^{99m}Tc-DTPA$ aerosol inhalation and Technegas ventilation. In both studies image quality was assessed (1) semiquantitatively by scoring bronchial and gastric activity, (2) subjectively by direct visual comparison of peripheral lung images and (3) quantitatively by computing the peripheral penetration index(PI) for each lungs. The bronchial activites were seen in 7 out of 12 cases with $^{99m}Tc-DTPA$ aerosol and in 5/12 with Technegas. The gastric activities were seen in 5/12 and 1/12 cases respectively. The average values of PI were 61.26% with $^{99m}Tc-DTPA$ aerosol and 69.20% with Technegas (p>0.05). Using $^{99m}Tc-DTPA$ aerosol, COPD patients showed deposition in the central airways with poor visualization of the peripheral areas of the lungs. In Technegas studies these phenomena were less prominent, and the examination is well tolerated by pateients and requires only a minimum of patient cooperation. With superiority of easy availability and handling, better physical characteristics and favorable Image quality, Technegas is a Promising agent for lung ventilation scanning.

  • PDF

COMPARISON OF DIFFUSION COEFFICIENTS AND ACTIVATION ENERGIES FOR AG DIFFUSION IN SILICON CARBIDE

  • KIM, BONG GOO;YEO, SUNGHWAN;LEE, YOUNG WOO;CHO, MOON SUNG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.5
    • /
    • pp.608-616
    • /
    • 2015
  • The migration of silver (Ag) in silicon carbide (SiC) and $^{110m}Ag$ through SiC of irradiated tristructural isotropic (TRISO) fuel has been studied for the past three to four decades. However, there is no satisfactory explanation for the transport mechanism of Ag in SiC. In this work, the diffusion coefficients of Ag measured and/or estimated in previous studies were reviewed, and then pre-exponential factors and activation energies from the previous experiments were evaluated using Arrhenius equation. The activation energy is $247.4kJ{\cdot}mol^{-1}$ from Ag paste experiments between two SiC layers produced using fluidized-bed chemical vapor deposition (FBCVD), $125.3kJ{\cdot}mol^{-1}$ from integral release experiments (annealing of irradiated TRISO fuel), $121.8kJ{\cdot}mol^{-1}$ from fractional Ag release during irradiation of TRISO fuel in high flux reactor (HFR), and $274.8kJ{\cdot}mol^{-1}$ from Ag ion implantation experiments, respectively. The activation energy from ion implantation experiments is greater than that from Ag paste, fractional release and integral release, and the activation energy from Ag paste experiments is approximately two times greater than that from integral release experiments and fractional Ag release during the irradiation of TRISO fuel in HFR. The pre-exponential factors are also very different depending on the experimental methods and estimation. From a comparison of the pre-exponential factors and activation energies, it can be analogized that the diffusion mechanism of Ag using ion implantation experiment is different from other experiments, such as a Ag paste experiment, integral release experiments, and heating experiments after irradiating TRISO fuel in HFR. However, the results of this work do not support the long held assumption that Ag release from FBCVD-SiC, used for the coating layer in TRISO fuel, is dominated by grain boundary diffusion. In order to understand in detail the transport mechanism of Ag through the coating layer, FBCVD-SiC in TRISO fuel, a microstructural change caused by neutron irradiation during operation has to be fully considered.