• 제목/요약/키워드: partial temperature

검색결과 1,452건 처리시간 0.029초

Impact of Temperature and Alkalinity on Nitrogen Removal in the Start-up Period of Partial Nitrification in a Sequence Batch Reactor

  • Nguyen Van Tuyen;Tran Hung Thuan;Chu Xuan, Quang;Nhat Minh Dang
    • 공업화학
    • /
    • 제34권5호
    • /
    • pp.541-547
    • /
    • 2023
  • The effect of temperature and influent alkalinity/ammonia (K/A) ratio on the start-up of the partial nitrification (PN) process for an activated sludge-based domestic wastewater treatment was studied. Two different sequence batch reactors (SBR) were operated at 26 ℃ and 32 ℃. The relationship between temperature and the concentration of free ammonia (FA) and free acid nitrite (FNA) was investigated. A stable PN process was achieved in the 32 ℃ reactor when the influent ammonium concentration was lower than 150 mg-N/L. In contrast, the PN process in the 26 ℃ reactor had a higher nitrite accumulation rate (NAR) and ammonium removal efficiency (ARE) when the influent ammonia concentration was increased to more than 150 mg-N/L. Then three different ranges of the K/A ratio were applied to an SBR reactor. In the K/A range of 2.48~1.65, the SBR reactor achieved the highest NAR ratio (75.78%). This ratio helps to achieve the appropriate level of alkalinity to maintain a stable pH and provide a sufficient amount of inorganic carbon source for the activity of microorganisms. At the same time, FA and FNA values also reached the threshold to inhibit nitrite-oxidizing bacteria (NOB) without a significant effect on ammonia-oxidizing bacteria (AOB). Results showed that the control of temperature and K/A ratio during the start-up period may be important in establishing a stable and steady PN process for the treatment of domestic wastewater.

주조 형상기억 니켈-티타늄 합금의 초탄성 (SUPERELASTICITY OF CAST SHAPE MEMORY Ni-Ti ALLOY)

  • 최동익;최목균
    • 대한심미치과학회지
    • /
    • 제3권1호
    • /
    • pp.32-43
    • /
    • 1995
  • Ni-Ti alloy has excellent corrosion resistance, biocompatibility, shape memory effect and superelasticity, so it has been used widely in biomedical fields. But it has difficulty in casting due to its high melting temperature and oxygen affinity at high temperature. Recently it has been attempted to cast Ni-Ti alloy using new casting machine and investment. The purpose of this study was to examine the superelastic behavior of cast shape memory Ni-Ti alloy and to compare the mechanical properties of the cast shape memory alloy with those of commercial alloys for removable partial denture framework. Ni-Ti alloy(Ni 50.25%, Ti 49.75% : atomic ratio) was cast with dental argon-arc pressure casting machine and Type IV gold alloy, Co-Cr alloy, Ni-Cr alloy, pure titanium were cast as reference. Experimental cast Ni-Ti alloy was treated with heat($500{\pm}2^{\circ}C$) in muffle furnace for 1 hour. Transformation temperature range of cast Ni-Ti alloy was measured with differential scanning calorimetry. The superelastic behavior and mechanical properties of cat Ni-Ti alloy were observed and evaluated by three point bending test, ultimate tensile test, Vickers microhardness test and scanning electron microscope. The results were as follows : 1. Cast Ni-Ti alloy(Ni 50.25%, Ti 49.75% : atomic ratio) was found to have superelastic behavior. 2. Stiffness of cast Ni-Ti alloy was considerably lesser than that of commercial alloys for removable partial denture. 3. Permanent deformation was observed in commercial alloys for removable partial denture framework at three point bending test over proportional limit(1.5mm deflection), but was not nearly observed in cast Ni-Ti alloy. 4. On the mechanical properties of ultimate tensile strength, elongation and Vickers microhardness number, cast Ni-Ti alloy was similiar to Type IV gold alloy, Co-Cr alloy, Ni-Cr alloy and pure titanium. With these results, cast Ni-Ti alloy had superelastic behavior and low stiffness. Therefore, it is suggested that cast Ni-Ti alloy may be applicated to base metal alloy for removable partial denture framework.

  • PDF

국부적 용융이 ${Si_3}{N_{4p}}$/2124 Al 복합재의 초소성 거동에 미치는 영향 (II) (The Effect on Partial Melting on Superplastic Flow of ${Si_3}{N_{4p}}$/2124 Al Composites (II))

  • 정하국;김혜성
    • 한국재료학회지
    • /
    • 제11권7호
    • /
    • pp.585-589
    • /
    • 2001
  • 많은 연구결과들은 국부적 용융체의 존재가 고온인장 변형 시 발생하는 내부공극의 발달을 억제할 수 있음을 보고하고 있다. 그러나 이러한 국부적 용융체가 존재한다고 해서 반드시 고변형속도 초소성 현상이 관찰될 수 있는 것은 아니다. 금속기지와 보강재간의 계면에 국부적 용융체의 양이 너무 많이 존재하면 두상간의 결합력이 떨어져 금속기지상으로부터 보강재가 분리되는 현상이 야기될 수 있기 때문이다. 그러므로, $Si_3$$N_{4p}$ 2124 Al 복합재의 초소성 유동 특성을 이해하기 위해 변형온도에 따른 미세구조 변화와 계면특성을 조사하였다. 본 연구를 룽해 $Si_3$$N_{4p}$ 2124 Al 복합재에서 Al-기지와 $Si_3$$N_{4p}$ 강화상간의 계면상의 국부적 용융이 시작되는 온도부근에서는 큰 초소성 특성이 얻어지지만, 국부적 용융이 시작되는 온도를 지난 인장온도범위에서는 오히려 초소성 특성이 현저하게 저하되는 현상이 관찰되었다. 위의 실험결과는 $Si_3$$N_{4p}$ 2124 Al복합재의 고변형속도 초소성 거동에 기여하는 최적의 액상량이 존재한다는 것을 의미한다.

  • PDF

열화학 수소 제조를 위한 금속 치환 페라이트 매체의 부분 환원 및 물 분해 특성 (Partial Reduction and Water Splitting Characteristics of Metal Substituted Ferrite Mediums for Thermochemical Hydrogen Production)

  • 이동희;김홍순;차광서;박주식;강경수;김영호
    • 한국수소및신에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.356-364
    • /
    • 2007
  • The partial reduction and water splitting properties of metal substituted ferrite mediums for two-step thermochemical hydrogen production, were carried out by TPR/O(Temperature programmed reduction/oxidation) method at a temperature of below 1173 K and under atmospheric pressure. $ZrO_2$ was added to the ferrite as a binder to prevent the sintering. As the results, the reactivity of the metal species added to the ferrite mediums decreased in the order of Cu>Co>Ni>Mn, on the basis of water-splitting temperature. It was also found that the produced hydrogen amounts in the water-splitting step on partial reduced mediums were corresponding to the consumed hydrogen amounts in the previously partial reduction step.

송풍기와 폐풍기를 이용한 연소기내의 부분 예혼합화염 연소 특성에 관한 실험적 연구 (Experimental Investigation on premixed combustion Characteristics with suction & blow fans)

  • 강기발;오상헌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.143-148
    • /
    • 2001
  • We measured emission indices for $NO_x$, CO, temperature and radical characteristics for partially premixied flames formed by suction & blow fans air condition. At sufficiently high levels of partial premixing a double flame structure consisting of a rich premixed inner flame and outer diffusion flame was established similar to that previously observed in premixed flames. $NO_x$, Temperature, CO values were experimented with approximately constant air flow rate and decreasing equivalence ratios. The reduction in $NO_x$ and temperature at suction condition as compared with that for blow condition was approximately 20%, but on the contrary, CO emission was increased. In addition, We measured temperature distributions and found that temperature increased continuously with increasing partial premixing. We also estimated CH, $C_2$ radical intensity. CH and $C_2$ radicals provide evidence that, for the present measurement, CH and $C_2$ radicals intensity was associsated with their premixed component. And we observed stronger $C_2$, CH radicals intensity at suction conditions than blow conditions.

  • PDF

Suction과 blow fan을 이용한 연소기내의 부분 예혼합화염 연소 특성에 관한 실험적 연구 (Experimental Investigation on Premixed Combustion Characteristics with Suction & Blow Fans)

  • 강기발;김동일;오상헌
    • 한국연소학회지
    • /
    • 제7권2호
    • /
    • pp.15-23
    • /
    • 2002
  • We measured emission indices for $NO_x$, CO, temperature and radical characteristics for partially premixied flames formed by suction & blow fans air condition. At sufficiently high levels of partial premixing a double flame structure consisting of a rich premixed inner flame and outer diffusion flame was established similar to that previously observed in premixed flames. $NO_x$, Temperature. CO concentration were experimented with approximately constant air flow rate and decreasing equivalence ratios. The reduction in $NO_x$, and temperature at suction condition as compared with that for blow condition was approximately 20%, but on the contrary, CO emission was increased. In addition, We measured temperature distributions and found that temperature increased continuously with increasing partial premixing. We also estimated CH, $C_2$ radical intensity. CH and $C_2$ radicals provide evidence that, for the present measurement, CH and $C_2$ radicals intensity was associsated with their premixed component. And we observed stronger $C_2$, CH radicals intensity at suction conditions than blow conditions.

  • PDF

맥류의 유수발육기 저온장해유형과 피해시기 분류 (Classification for Types of Damages Caused by Cold Stress at Different Young Spike Development Stages of Barley and Wheat)

  • 구본철;박문웅;김기준;안종국;이춘우;윤의병
    • 한국작물학회지
    • /
    • 제48권3호
    • /
    • pp.252-261
    • /
    • 2003
  • 보리, 밀 품종의 조숙화와 온난한 겨울로 인하여 봄에 나타나는 저온장해가 최근에 자주 발생하는데 생육재생기 이후 발생하는 저온장해의 양상, 발생시기 및 증상을 구명하고자 자연조건과 저온항온기 그리고 포장의 비닐 피복을 이용한 저온처리시험을 실시한 결과를 보면 다음과 같다. 1. 저온장해중 줄기 고사는 -2.4∼$-10.2^{\circ}C$, 퇴화, 백수, 탈색등은 -2.4∼$-8.6^{\circ}C$,불임은 -1.3∼$-7.6^{\circ}C$의 저온에서 6-39시간 지속될 때 발생하였는데 특히 자연포장에서 많이 나타나는 저온장해는 불임과 퇴화로, 이의 유발온도는 -2.5∼$-3.0^{\circ}C$였다. 2. 보리, 밀 모두 수잉기에 불임이 많이 발생하였고 출수기, 영화분화기, 화기발육기 순으로 발생정도에 차이를 보였다 백수는 출수 전후 10일에 주로 발생하였으며 발생정도는 출수후 10일>출수기>수잉기 순이었다. 3. 유수퇴화는 출수기에 가장 많이 발생한 것으로 나타났고 수잉기, 화기발육기에도 많이 발생하였다. 부분희화도 수잉기에 많이 발생하였다. 포장에서는 영화분화기의 개체들에서도 많이 발생하였다. 4. 망 탈색은 주로 밀에서 발생하였는데 수잉기에 일부 발생하긴 했으나 출수기의 식물체에서 대부분이 발생하여 출수기에 주로 나타나는 장해라 할 수 있었다. 식물체 고사는 전 생육기에 걸쳐 발생하였고 가장 심한 피해는 출수기>수잉 >영화분화기>화기 발육기 순으로 발생한 것으로 나타났다. 5. 저온장해 발생지표로 유수장, 제1절간장, 지엽-이삭간 거리가 유용하였다. 유수장이 밀에서는 망 탈색시 9.0-9.8cm, 이삭 탈색시 7.5cm, 백수발생시 5.7-9.4cm, 이삭 퇴화시 0.2-9.2cm, 줄기고사시 0.3-3.8cm로 나타났고 보리에서는 백수발생시 평균 3.4-7.0cm, 부분퇴화가 4.2-5.2cm, 퇴화가 0.4-5.4cm, 줄기 고사가 0.4-0.6cm로 차이를 보였다. 제1절간장은 보리, 밀 각각 0.3-8.4cm, 0.2-24.2cm로 신장정도에서 저온에 따른 변이를 보였고, 지엽-이삭간 거리도 보리 -2.5∼-7.4cm, 밀 -0.6-11.5cm로 신장정도에 차이가 컸다.

배선에서의 반단선 및 접촉불량에 대한 열적 전조 DB구축 (Development of Thermal Precursor DB for Partial Disconnection and Poor Contact on Electrical Wire)

  • 김두현;김성철;이종호;강동규
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.30-36
    • /
    • 2009
  • This paper aims at the precursor analysis and DB development of electrical fires based on thermal and current signals for partial disconnection and poor contact on electric wires through experiments and simulations. Also, DB system required for developing the precursor DB with these data was studied and designed. Firstly, in case of partial disconnection, characteristics were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF and IV electric wires. Based on the characteristics, About 351 partial disconnection precursor patterns were generated by the thermal analysis for electric wire according to deterioration time under normal state and 200% overload state of rated current. Secondly, in order to develop poor contact precursor patterns, temperature value and the current signal were considered. In simulating the poor contact situation on connector area of MCCB, connection torque was changed. Through the experimental analysis, about 251 poor contact precursor patterns were generated. Finally, Using thermal precursor patterns obtained by partial disconnection and poor contact, electrical fire thermal precursor DB was developed.

A New Charge Analysis Derived From the Results of Semi-Emprical Mo-Lcao Calculation

  • Yilmaz, Hayriye;Ceyhan, Emre Cahit;Guzel, Yahya
    • 대한화학회지
    • /
    • 제56권2호
    • /
    • pp.195-200
    • /
    • 2012
  • In this study we present a new approach for computing the partial atomic charge derived from the wavefunctions of molecules. This charge, which we call the "y_charge", was calculated by taking into account the energy level and orbital populations in each molecular orbital (MO). The charge calculations were performed in the software, which was developed by us, developed using the C# programming language. Partial atomic charges cannot be calculated directly from quantum mechanics. According to a partitioning function, the electron density of constituent molecular atoms depends on the electrostatic attraction field of the nucleus. Taking into account the Boltzmann population of each MO as a function of its energy and temperature we obtain a formula of partial charges.

부분방전 전자파 측정용 광대역 주파수 분석 시스템 개발 (The Development of wide frequency analyzing system by partial electric discharge electromagnetic-wave Receiver)

  • 박두용;신영진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.547-549
    • /
    • 2004
  • This system is monitors the degree of aging happened at the electric machine. It detects electromagnetic wave generated from the insulator when the voltage is applied to the machine. By analyzing the internal and external factors make the electric, mechanic, or thermal characteristics of the electric machinery deteriorate the electric insulation and eventually cause the partial electric discharge. The continuous partial electric charge accelerates the insulation aging and the insulation breakdown happens at last. This system consists of the relays connected with 10 sensors (40 total) detecting the partial electric discharge ans the temperature, the server, ans the program analyzing and storing the data.

  • PDF