• Title/Summary/Keyword: partial stripping

Search Result 7, Processing Time 0.024 seconds

Spalling Resistance of High Strength Concrete Using Non-Stripping Form (비탈형 거푸집에 의한 고강도 콘크리트의 폭렬방지)

  • You, Ji-Young;Han, Chang-Pyung;Jee, Suk-Won;Han, Min-Cheol;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.865-868
    • /
    • 2008
  • As a part of a series of study, this study reviewed the fire proof characteristics of high performance concrete RC column members using non-stripping form that accompanied metal lath lateral confinement to prevent spalling of high performance concrete which is increasingly used recently, and the results are as follows. Flow and air amount both satisfied target range, and compressive strength, over 80MPa at age 28 days, showed high strength range. As for spalling characteristics, in the case of plain in which no fiber is mixed, severe spalling occurred, and in the case of 0.05% nylon("NY" hereinafter)+polypropylene("PP" hereinafter) fiber mixture, only surface area experienced partial spalling. Regarding non-stripping form changes, both non-stripping 25-20 and non-stripping 50-20 experienced spalling at finish material area, and non-stripping 50-20 showed better spalling proof performance than non-stripping 25-20. In the case of non-stripping 50-40, spalling was prevented, and while mass reduction rate was less than 10%, its temperature hysteresis showed the most excellent fire proof performance with base metal surface area maximum temperature $376.1^{\circ}C$.

  • PDF

Partial Nitrification of Wastewater with Strong N for Anaerobic Nitrogen Removal (혐기성 질소제거를 위한 고농도 질소폐수의 부분질산화)

  • Hwang, In-Su;Min, Kyung-Sok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.414-420
    • /
    • 2006
  • Effluent from an anaerobic digestion system with an elutriated phased treatment(ADEPT, Anaeorbic Digestion Elutriated Phase Treatment) for piggery waste treatment using anaerobic ammonium oxidation(ANAMMOX) process was used as a substrate of partial nitrification reactor. In mesophilic condition($35^{\circ}C$), controlling parameters of nitrite accumulation were HRT, pH, free ammonia(FA) and hydroxylamine rather than dissolved oxygen. Bicarbonate alkalinity consumption ratio including bicarbonate stripping and buffering was 8.78 g $Alk._{comsumed}/g\;NH_4-N_{converted}$. In steady state for 1 day of HRT and $2.7{\sim}4.4mg/L$ of DO, $NO_2-N/NH_4-N$ ratio of partial nitrification effluent was about $1{\sim}3$, which was applicable to ANAMMOX reactor influent for the combined partial nitrification-ANAMMOX process.

Effect of Deodorizing Temperature on Physicochemical Characteristics in Corn Oil IV. Effect of Deodorizing Temperature on Volatile Flavor Component Composition in Corn Oil (탈취온도가 옥수수기름의 이화학적 특성에 미치는 영향 제4보, 탈취온도가 옥수수기름의 휘발성 냄새성분 변화에 미치는 영향)

  • 이근보;한명규;이미숙
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.3
    • /
    • pp.272-277
    • /
    • 1998
  • We carried out separation and guantitation of flavor components by GC about essential oils extracted from deodorized corn oil at the different deodorizing temperature. Flavor components were detected total 16 kinds included aldehydes of 8 kinds, major components were propane, pentane, hexanal etc. These major components content was about 70~75% of the total flavor components. According to rise of deodorizing temperature, both ethane and aldehydes of 8 kinds content were in proportion to increase, but propane, pentane, hexane, octan, pentyl furan content were decreased by contraries, respectively. On the other hand, total flavor component content was appeared the lowest level at 245$^{\circ}C$ treating group, aldehydes content was in proportion to increase according to rise of deodorizing temperature. These phenomenons consider that the undesirable reactions such as partial auto-oxidation, degradation, polymerization and hydrolysis etc. by effecting factors of stripping steam and vacuum degree. Conclusively, deodorizing temperature under high temperature was undesirable for the minimization of off-flavor materials.

  • PDF

A CASE REPORT OF TOTAL AVULSED SCALP WITH RIGHT TOTAL EAR (우측이부를 포함한 전두피박이환자의 재이식 치험예)

  • Lee, Yeoul-Hi;Byun, Gi-Jung;Kim, Shin-Ho
    • The Journal of the Korean dental association
    • /
    • v.15 no.2
    • /
    • pp.115-120
    • /
    • 1977
  • Extensive avulsion of the scalp, or stripping of a large area of soft tissue from the skull, is a serious accidnet. The avulsed scalp is often injured otherwise, such as by crushing, tearing, or from multiple laceration. The surrounding skin may be devitalized. Replacement of the scalp is usually followed by necrosis and sloughing within a short time. In such instances, the outer table of the cranium may become sucessively exposed. dry, dead, and affected by osteomyelitis. Hence the securing of early healing to prevent these is of the utmost importance. The successful case of reimplantation of the completely avulsed scalp, which is exposured to air for about 14 hours, is reported, in which there was partial growth of hair afterwards. The avulsed scalp caused by her long hair being caught in a grain belt was contaminated with hairs & dust. Authors treated this 19-year old female patient by split thickness skin graft, intermediate skin graft, full thickness skin graft from her own avulsed scalp.

  • PDF

Fixation Method of Prestressed Fiber Optic Sensor (광섬유센서의 프리스트레인 부가 고정방식)

  • Kim, Ki-Soo
    • Composites Research
    • /
    • v.25 no.6
    • /
    • pp.211-216
    • /
    • 2012
  • FBG sensor peaks could be split due to polarization by shear strain, when the fiber optic sensors embedded or attached to the structure. For the fiber optic sensor packages, sensor grating has to be protected from shear strains. Also, pretension has to be applied to the sensor because compressive strain must be measured. Without pretension of sensor, the sensor does not show any change of signal until it is stretched. In order to mesure compressive and tensile strains, two fixing point and prestressed sensor need. In the fixing point, just holding the optical fiber cause slip between core and cladding in the fiber. A Fixation method of prestressed FBG sensors fixed with partially stripped fibers was developed. The sensor package has the prestress controllable fixtures at the fixing points. Prestress to the sensor imposed by controlling the two fixed points with bolts and nuts make it easy to measure compressive strain as well as tensile strain. The fiber optic sensor packages applied to the actual structure and the structural monitoring system using the package can be applied to safety through surveillance.

Influencing Factors Analysis of Facial Nerve Function after the Microsurgical Resection of Acoustic Neuroma

  • Hong, WenMing;Cheng, HongWei;Wang, XiaoJie;Feng, ChunGuo
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.2
    • /
    • pp.165-173
    • /
    • 2017
  • Objective : To explore and analyze the influencing factors of facial nerve function retainment after microsurgery resection of acoustic neurinoma. Methods : Retrospective analysis of our hospital 105 acoustic neuroma cases from October, 2006 to January 2012, in the group all patients were treated with suboccipital sigmoid sinus approach to acoustic neuroma microsurgery resection. We adopted researching individual patient data, outpatient review and telephone followed up and the House-Brackmann grading system to evaluate and analyze the facial nerve function. Results : Among 105 patients in this study group, complete surgical resection rate was 80.9% (85/105), subtotal resection rate was 14.3% (15/105), and partial resection rate 4.8% (5/105). The rate of facial nerve retainment on neuroanatomy was 95.3% (100/105) and the mortality rate was 2.1% (2/105). Facial nerve function when the patient is discharged from the hospital, also known as immediate facial nerve function which was graded in House-Brackmann : excellent facial nerve function (House-Brackmann I-II level) cases accounted for 75.2% (79/105), facial nerve function III-IV level cases accounted for 22.9% (24/105), and V-VI cases accounted for 1.9% (2/105). Patients were followed up for more than one year, with excellent facial nerve function retention rate (H-B I-II level) was 74.4% (58/78). Conclusion : Acoustic neuroma patients after surgery, the long-term (${\geq}1year$) facial nerve function excellent retaining rate was closely related with surgical proficiency, post-operative immediate facial nerve function, diameter of tumor and whether to use electrophysiological monitoring techniques; while there was no significant correlation with the patient's age, surgical approach, whether to stripping the internal auditory canal, whether there was cystic degeneration, tumor recurrence, whether to merge with obstructive hydrocephalus and the length of the duration of symptoms.

Endovenous 980-nm Diode Laser Treatment of Incompetent Great Saphenous Vein (정맥 내 980-nm 다이오드 레이저를 이용한 대복재정맥 역류의 치료)

  • Kim, Kun-Il;Jo, Tae-Jun;Lee, Jae-Woong;Hong, Ki-Woo;Lee, Won-Yong
    • Journal of Chest Surgery
    • /
    • v.40 no.2 s.271
    • /
    • pp.97-102
    • /
    • 2007
  • Background: Endovenous laser treatment has recently been introduced as a less invasive technique, with many good results reported, A 980-nm diode laser was used on the great saphenous vein (GSV) occlusions in patients with varicose veins, due to GSV reflux, and the therapeutic effects analyzed. Material and Method: Between September 2003 and February 2006, 238 patients (332 cases) with GSV reflux underwent endovenous laser treatment with a 980-nm diode laser. Operative procedures were simultaneous endovenous laser treatment and ambulatory phlebectomy. The preoperative clinical findings, postoperative complications and postoperative duplex US follow up results at 1 and 3 months were reviewed. Result: Postoperative complications were ecchymosis in almost cases, paresthesia 68 cases (20.5%) and skin burn in 3 cases (0.9%). Follow up duplex US revealed 26 and 10 cases at 1 and 3 months of GSV reflux or partial recanalization, with therapeutic success rates of 91.3 and 87.9%, respectively. Conclusion: The treatment of GSV occlusion with an endovenous laser is less invasive than traditional GSV stripping, but relatively high recanalization was experienced, possibly due to inadequate laser power, laser fiber pullback speed or an extremely dilated GSV. However, continuous attempts will be required to reduce the recanalization after the procedure, with accurate follow up using duplex US.