• Title/Summary/Keyword: partial function

Search Result 1,243, Processing Time 0.044 seconds

Changes of Coagulability after Off-pump CABG: Comparison with On-pump CABG (심폐바이패스 없이 시행하는 관상동맥우회술 후 혈액응고 기늠의 변화: 심폐바이패스하 관상동맥우회술 후 혈액응고 상태와의 비교)

  • 장우익;김기봉;김욱성;정철현;허재학;장지민;이동순;한규섭
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.245-251
    • /
    • 2004
  • Hemostatic function is regarded to be preserved after an off-pump coronary artery bypass grafting (CABG), compared to conventional CABG, and the preserved hemostatic function may increase thrombotic occlusion of the graft. We studied the changes of hemostatic variables in patients undergoing off-pump CABG, and compared to those of on-pump CABG. We studied the changes of coagulation function in 11 patients who underwent off-pump CABG (group I), and compared them with those of 11 patients who underwent on-pump CABG and Dor procedure (group II). Coagulation status was evaluated by thromboelastography and blood coagulation test preoperatively, postoperative 1$^{st}$ day, 2$^{nd}$ day, 3$^{rd}$ day, and 5$^{th}$ day, respectively. Among the variables measured by thromboelastography (such as r time, k time, $\alpha$ angle, and MA value) and blood coagulation test (such as factor Ⅶ, protein S, protein C, antithrombin III, activated protein C resistance test, plasminogen, D-dimer, prothrombin time, activated partial thromboplastin time, platelet count, hemoglobin, and fibrinogen), there were significant differences in the MA value, $\alpha$ angle, and platelet counts between the two groups. MA values were 140$\pm$72% and 153$\pm$98% in group I, and 87$\pm$27% and 78$\pm$28% in group II, at postoperative 3$^{rd}$ and 5$^{th}$ days, respectively (p<0.05). $\alpha$ angle was 122$\pm$92% in group I and 69$\pm$23% in group II at postoperative 3$^{rd}$ day (p=0.09). Platelet count was 63$\pm$55% in group I and 33$\pm$13% in group II at postoperative 3$^{rd}$ day (p<0.05). Patients who underwent off-pump CABG showed increased coagulability during postoperative periods, compared to those who underwent on-pump CABG. Our data suggest that aggressive perioperative anticoagulation therapy is warranted in patients undergoing off-pump CABG. CABG.

Comparison of Deep Learning Frameworks: About Theano, Tensorflow, and Cognitive Toolkit (딥러닝 프레임워크의 비교: 티아노, 텐서플로, CNTK를 중심으로)

  • Chung, Yeojin;Ahn, SungMahn;Yang, Jiheon;Lee, Jaejoon
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.2
    • /
    • pp.1-17
    • /
    • 2017
  • The deep learning framework is software designed to help develop deep learning models. Some of its important functions include "automatic differentiation" and "utilization of GPU". The list of popular deep learning framework includes Caffe (BVLC) and Theano (University of Montreal). And recently, Microsoft's deep learning framework, Microsoft Cognitive Toolkit, was released as open-source license, following Google's Tensorflow a year earlier. The early deep learning frameworks have been developed mainly for research at universities. Beginning with the inception of Tensorflow, however, it seems that companies such as Microsoft and Facebook have started to join the competition of framework development. Given the trend, Google and other companies are expected to continue investing in the deep learning framework to bring forward the initiative in the artificial intelligence business. From this point of view, we think it is a good time to compare some of deep learning frameworks. So we compare three deep learning frameworks which can be used as a Python library. Those are Google's Tensorflow, Microsoft's CNTK, and Theano which is sort of a predecessor of the preceding two. The most common and important function of deep learning frameworks is the ability to perform automatic differentiation. Basically all the mathematical expressions of deep learning models can be represented as computational graphs, which consist of nodes and edges. Partial derivatives on each edge of a computational graph can then be obtained. With the partial derivatives, we can let software compute differentiation of any node with respect to any variable by utilizing chain rule of Calculus. First of all, the convenience of coding is in the order of CNTK, Tensorflow, and Theano. The criterion is simply based on the lengths of the codes and the learning curve and the ease of coding are not the main concern. According to the criteria, Theano was the most difficult to implement with, and CNTK and Tensorflow were somewhat easier. With Tensorflow, we need to define weight variables and biases explicitly. The reason that CNTK and Tensorflow are easier to implement with is that those frameworks provide us with more abstraction than Theano. We, however, need to mention that low-level coding is not always bad. It gives us flexibility of coding. With the low-level coding such as in Theano, we can implement and test any new deep learning models or any new search methods that we can think of. The assessment of the execution speed of each framework is that there is not meaningful difference. According to the experiment, execution speeds of Theano and Tensorflow are very similar, although the experiment was limited to a CNN model. In the case of CNTK, the experimental environment was not maintained as the same. The code written in CNTK has to be run in PC environment without GPU where codes execute as much as 50 times slower than with GPU. But we concluded that the difference of execution speed was within the range of variation caused by the different hardware setup. In this study, we compared three types of deep learning framework: Theano, Tensorflow, and CNTK. According to Wikipedia, there are 12 available deep learning frameworks. And 15 different attributes differentiate each framework. Some of the important attributes would include interface language (Python, C ++, Java, etc.) and the availability of libraries on various deep learning models such as CNN, RNN, DBN, and etc. And if a user implements a large scale deep learning model, it will also be important to support multiple GPU or multiple servers. Also, if you are learning the deep learning model, it would also be important if there are enough examples and references.

A Study on Make-up Culture of Korea, China and Japan (한국.중국.일본 여성의 색조대장문화)

  • 박보영;황춘섭
    • Journal of the Korean Society of Costume
    • /
    • v.39
    • /
    • pp.217-237
    • /
    • 1998
  • The present research is to study the make-up culture of Korea and its neighboring countries such as China and Japan during the period from the prehistoric age to the 19th cen-tury. The research was made by documents analysis. The results are summerised as follows : (1) A man has a basic instinct to beautify himself. There was not a significant difference between the make-up behavior of men and women in its primal stage. It was by the start of farming and the division of labor that made the make-up behavior as a feminine culture. The difference of sexual role caused the con-ceptual difference between manly beauty and womanly beauty. It was very natural for women to regard the make-up as the best way for showing their feminine beauty. In Korea, China and Japan, there were vari-ous kinds of primal actions such as tattooing, body-painting, and tooth make-up which were used in the purpose of body protection, incantation, ornament, and so on. Ass their ornamental purpose was becoming more important, these primal actions became the basis of the feminine make-up culture. Nowadays make-up, having mental and emo-tional function, is helpful to increasing self-satisfaction, promoting good personal relation-ship, and attracting attention from the other sex. It also has other functions of showing social status, wealth, age, sex, courage, power, and so on. (2) The representative make-up product used widely in the three countries was Boon (powder) which decides the overall color of face. The key point in the production of Boon was to increase its power of adsorption. The invention of Yunboon (power mixed with lead) solved this major problem of Boon. Yeonji which decides the color of cheek was the mixture of Boon and the powder of Honghwa (a kind of red-colored flower or tree). Mimook (eyebrow pencil) was developed to match up with the various and changing currencies of penciling eyebrows in each nation and times, Yeonji and Joosa (red sand) were used as Jinji (lip stick). The predominant color of Jinji was red. As miscellaneous methods of partial make-up, there were Kon-ji used in a wedding cer-emony in korea, Aek-hwang, Hwa-jeon, Sa-hong, and Myun-yup in China, and Chi-heuk, a peculial method of partial make-up in japan. (3) There were various factors which decided the characteristics of make-up culture usually reflects international atmosphere, the form of government, economic situation, re-ligious and social ideology, aesthetic sense, symbolizing meanings of colors, and so on. The up and down of an influentian country was one of the major factors which decided the characteristics of the make-up culture of its neighboring countries. When a country took a liberal form of government, it had diverse and splendid tendencies in its make-up culture. The better a nation's economic situation is, the more abandant and various its make-up culture is, and sometimes, the more eccentric and decadents it was. In the field of make-up production, the three countries had their own characteristics. But, as a whole, China was the leading nation who spread the culture and products of make-up to Korea and Japan. Though the Chinese make-up culture and products were usually spread to Japan through Korean, there was some evidence of direct exchanges between China and Japan through its dispatches of Kyun-Tang-Sa(Japanese delegation to the Tang Dynasty). While religion had a positive influence on the development of make-up culture by introducing new methods of make-up, Confucianism exercised strict control over the make-up cul-ture. The currencies in arts and changes of esthetic sense introduced new methods and booms to the make-up culture. Literature made people pay increasing attentions to the countenances of women and changed the standards of esthetic sense. We can find out that the social status of woman was also reflected in the make-up culture. As the social status of women became higher, the feminine make-up culture also developed more then ever. As mentioned above, the make-up cultures of the three countries reflected their social values, esthetic senses, and emotional feelings. Through their cultural exchanges, the three countries could develop various make-up products and methods.

  • PDF

Effect of attachments and palatal coverage of maxillary implant overdenture on stress distribution: a finite element analysis (상악 임플란트 피개의치에서 유지장치 종류와 구개 피개 유무에 따른 응력분포에 대한 유한요소분석)

  • Park, Jong-Hee;Wang, Yuan-Kun;Lee, Jeong-Jin;Park, Yeon-Hee;Seo, Jae-Min;Kim, Kyoung-A
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.70-79
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effect of attachments and palatal coverage on stress distribution in maxillary implant overdenture using finite element analysis. Materials and Methods: Four maxillary overdenture 3-D models with four implants placed in the anterior region were fabricated with computer-aided design. 1) Ball-F: Non-splinted ball attachment and full palatal coverage, 2) Ball-P: Non-splinted ball attachment and U-shaped partial palatal coverage, 3) Bar-F: Splinted milled bar attachment and full palatal coverage, 4) Bar-P: Splinted milled bar attachment and U-shaped partial palatal coverage. Stress distribution analysis was performed with ANSYS workbench 14. 100 N vertical load was applied at the right first molar unilaterally and maximum stress was calculated at the implant, peri-implant bone and mucosa. Results: The use of the ball attachment showed lower maximum stress on implant and peri-implant bone than the use of the milled bar attachment. But it showed contrary tendency in the mucosa. Regardless of attachment, full palatal coverage showed lower maximum stress on implant, peri-implant bone and mucosa. Conclusion: Within the limitation of this study, ball attachment improved stress distribution on implant and peri-implant bone rather than milled bar attachment in maxillary implant overdenture. Also, full palatal coverage is more favorable in stress distribution.

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.

The Clinical Outcomes of Arthroscopic Repair of Isolated type II SLAP Lesion in Non-athletes (비 운동선수에 있어 단독 제 2형 SLAP 병변의 관절경적 봉합수술의 임상적 결과)

  • Yoo, Jae-Chul;Ahn, Jin-Hwan;Koh, Kyoung-Hwan;Kim, Seung-Yeon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.185-190
    • /
    • 2008
  • Purpose: The purpose of this study is to provide the clinical outcomes of arthroscopic type II SLAP repair in non-athletes, and to compare the clinical outcomes between those who had isolated type II SLAP lesion and those who had combined partial thickness supraspinatus tear that did not required a combined repair. Materials and Methods: From July 2005 to January 2007, 142 consecutive type II SLAP lesions were treated with arthroscopic surgery. The inclusion criteria for the study were; (1) younger than 50 years old; and (2) non-athletes. Exclusion criteria were; (1) prior surgery, fracture or combined recurrent dislocation history on the affected shoulder; (2) combined full thickness rotator cuff tear or PTST (>50% thickness) patient that needed repair; and (3) combined infection, arthritis or inflammatory disease. Remaining 19 patients meet the criteria. Among them, 13 had combined PTRCT that did not require repair (Group I), and 6 had isolated type II SLAP lesion without combined supraspinatus tear (Group II). The mean age was 36.7 years (29~49 years), mean symptom duration was 39.1 months (3~216 months) and mean follow-up was 19.0 months (12~27 months). In all patients, the range of motion of affected shoulder, pain and function visual analogue scale (PVAS, FVAS), the Constant score and UCLA score were evaluated preoperatively and postoperatively. Results: In group I, external rotation at side was decreased significantly (p=0.003),but there were no statistical significant change at the remains(p>0.05). And there were no differences between groups (p>0.05). At the final follow-up, all clinical outcome measurements improved after surgery with statistical significance (p<0.05): UCLA score, $22.8{\pm}5.2$ to $32.8{\pm}2.1$; Constant score, $79.4{\pm}8.6$ to $94.9{\pm}4.3$; PVAS $5.4{\pm}2.7$ to $1.1{\pm}1.4$; FVAS $63.2{\pm}15.3$ to $93.4{\pm}7.3$. But, in group comparison of the mean UCLA score and Constant score, there were no statistical significant differences between two groups. Conclusion: Arthroscopic repair of type II SLAP lesion provided good clinical outcomes in nonathletic population. Combined partial thickness supraspinatus tear does not seem to hamper the final outcome at minimal 1 year follow-up.

  • PDF

Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.643-649
    • /
    • 1998
  • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

  • PDF

Preliminary Result in Patients with Primary Hepatoma Treated by Stereotactic Radiotherapy (원발성 간암에 대한 정위방사선치료의 예비결과)

  • Kang Ki Mun;Choi Ihl Bohng;Kim In Ah;Choi Byung Ock;Kang Young Nam;Chai Gyu Young;Han Sung Tae;Chung Gyu Won
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.34-39
    • /
    • 2001
  • Purpose : It is not common to evaluate the response of the fractionated stereotactic radiotherapy (SRT) to primary hepatoma as compared with conventional radiotherapy. The purpose of the study was to take the preliminary result on the clinical trial of primary hepatoma by SRT. Materials and Methods : From July 1999 to March 2000, thirty three patients were hospitalized in the St. Mary's Hospital, and treated with SRT for extracranial tumors. Among them, 13 patients were diagnosed to primary hepatoma and then applied by frameless SRT using 6 MV linac accelerator. There were 12 male and 1 female patients. They had the age of $ 44\~66$ year old (median : 59) and the tumor size of $10\~825\;cc$ (median : 185 cc). SRT was given to them $3\~5$ fractions a week (5 Gy/fraction, $90\%$ isodose line) for $2\~3$ weeks. Median dose of SRT was 50 Gy and the range was $30\~50\;Gy$. Results : Follow-up period ranged from 3 months to 13 months with median of 8 months. After treating SRT to thirteen patients with primary hepatoma, the response of the tumor was examined by abdominal CT : they are classified by 1 complete regression $(7.7\%)$, 7 partial regression $(53.8\%)$, 4 minimal regression $(30.8\%)$, 1 stable disease $(7.7\%)$. The positive responses more than partial remission were 8 patients $(61.5\%)$ after the treatment. The level of serum alpha-fetoprotein (AFP) after the treatment as compared with pretreatment had been $92.3\%$ decreased. There was no severe complication except dyspepsia $84.6\%$, mild nausea $69.2\%$, transient decreased of hepatic function $15.4\%$ and fever $7.7\%$. Conclusion : SRT to the patients with primary hepatoma was potentially suggested to become the safe and more effective tool than the conventional radiotherapy even though there were relatively short duration of follow-up and small numbers to be tested.

  • PDF

Comparison of relative fitness between zirconia single coping and 3-unit fixed partial dentures (FPDs) manufactured by dental CAD/CAM system (치과 캐드/캠 시스템으로 제작된 지르코니아 single 코핑과 3-unit 구조물의 상대적 적합도 비교)

  • Lee, Wan-Sun;Park, Jong-Kyoung;Kim, Wook-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.16-22
    • /
    • 2014
  • Purpose: The purpose of this study was to assess the marginal and mesial fitness of zirconia single copings and 3-unit fixed partial dentures (FPDs) manufactured with an identical model. Materials and Methods: An epoxy model in which the maxillary right 2nd premolar is lost and maxillary 1st premolar and 2nd molar are formed as abutments was manufactured and scanned by using a laser scanner. A ten units of zirconia single copings were manufactured for maxillary 1st premolar and 2nd molar, respectively and the same number of 3-unit FPDs were manufactured. For the measurements of fitness, the manufactured silicone replicas were divided into four parts and the fitness were measured by digital microscope at measurement points (P1, P2, P3, P4 and P5) of each plane. The measured gaps were classified into three categories: marginal gap (MG, P1), axial gap (AG, average of P2 and P3), occlusal gap (OG, average of P4 and P5). Results: The ranges of MG, AG and OG for single copings were 18.47 - 40.54 ${\mu}m$, 39.73 - 73.61 ${\mu}m$ and 116.90 - 134.69 ${\mu}m$, respectively. The ranges of MG, AG and OG for 3-unit FPDs were 45.95 - 87.44 ${\mu}m$, 23.78 - 57.00 ${\mu}m$ and 99.89 - 131.06 ${\mu}m$, respectively. Conclusion: The result of the study shows that the MGs for 3-unit FPDs were higher than those of single copings, though they are within the range of clinical acceptance, indicating that the use of more homogeneous zirconia block and modification of sintering processes are needed to ensure the prevention of increase of gap in 3-unit FPDs.

Arthroscopic Repair of Traumatic Subscapularis Tendon Tear (외상성 견갑하건 파열의 관절경하 봉합술)

  • Cho, Su-Hyun;Cho, Hyung-Lae;Ku, Jung-Hoei;Hwang, Tae-Hyok;Park, Man-Jun;Choi, Jae-Hyuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.3
    • /
    • pp.180-187
    • /
    • 2010
  • Purpose: Rotator cuff tears involving the subscapularis are less common than those involving the superior and posterior rotator cuff. The purpose of the present study was to report the clinical results of repair of isolated traumatic tears of the subscapularis tendon. Materials and Methods: Fifteen patients (13 males, 2 females; mean age 46.2 years; range 35 to 52) with unilateral ruptures of the subscapularis tendon after trauma who underwent arthroscopic repair between February 2003 and October 2008 were reviewed retrospectively. All the cases were isolated tears of the subscapularis without the involvement of any other rotator cuff tendon and were followed for at least two years (mean 28 months). The entire subscapularis was involved in 9 cases and the tear was localized to the upper two thirds in 6 cases. The preoperative and postoperative status of patients with isolated subscapularis tears were analyzed using the Constant Score, American Shoulder and Elbow Society Index (ASES Index) and postoperative integrity was determined through magnetic resonance imaging. Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up. The constant shoulder score improved from 41.5 to 81.3 points (P<0.05) compared to before surgery and ASES index improved from 46.4 to 89.6 points (P<0.05) postoperatively. Thirteen patients (87%) were satisfied with the result of the treatment. The total tears were significantly more improved by surgery than the partial tears. In 12 of 15 patients (80%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 13 months postoperatively. The postoperative score was significantly lower for the patients with a failed repair than it was for those with an intact repair (P<0.05). Conclusion: Repair of traumatic isolated subscapularis tears through arthroscopic techniques effectively restores patient function with regard to pain, mobility, strength and postoperative tendon integrity. The postoperative integrity of the repair correlates with the functional results and the total tears were more improved by surgery than the partial tears, but future studies may be needed.

  • PDF