• 제목/요약/키워드: partial efficiency

검색결과 698건 처리시간 0.03초

Numerical Prediction of Unsteady Flows through Whole Nozzle-Rotor Cascade Channels with Partial Admission

  • Sasao, Yasuhiro;Monma, Kazuhiro;Tanuma, Tadashi;Yamamoto, Satoru
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권3호
    • /
    • pp.248-253
    • /
    • 2009
  • This paper presents a numerical study for unsteady flows in a high-pressure steam turbine with a partial admission stage. Compressible Navier-Stokes equations are solved by the high-order high-resolution finite-difference method based on the fourth-order compact MUSCL TVD scheme, Roe's approximate Riemann solver, and the LU-SGS scheme. The SST-model is also solved for evaluating the eddy-viscosity. The unsteady two-dimensional flows through whole nozzle-rotor cascade channels considering a partial admission are numerically investigated. 108 nozzle passages with two blockages and 60 rotor passages are simultaneously calculated. The influence of the flange in the nozzle box to the lift of rotors is predicted. Also the efficiency of the partial admission stage changing the number of blockages and the number of nozzles is parametrically predicted.

부분 무치악 환자에서 텔레스코프 시스템을 적용한 전악 수복 증례 (A Telescopic System and Its Clinical Application for the Restoration of the Partially Edentulous Arch)

  • 신미란
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.139-144
    • /
    • 2007
  • Prosthodontic treatment planning for various edentulous arches is not an easy issue for dentists. Especially, in case of removable partial denture, we must have a knowledge of overall treatment procedures, and a careful approach is needed. Recently, interest of dental implant and case reports are increasing, the decrease of the removable partial denture is true, but dental implantation takes longer treatment period and it is more expensive. Also, there are still some limitations like lack of available alveolar bone, patient's general condition, and chronic periodontitis. Therefore, sometimes implantation is impossible. Finally, implantation cannot be adapted to every single patient. Currently, the clasp type removable partial dentures are used routinely, giving patients many unesthetic and functional difficulties. With better laboratory technique, removable partial denture with attachment and removable partial denture in rigid type increase patient's happiness level much more than predicted. The case presented in this article, clinically demonstrate the efficiency of using a telescopic system to improve esthetic and functional recovery for patients who lose multiple teeth.

보조부분 공진 회로를 이용한 삼상 PWM 인버터의 고조파 제거 (Elimination of harmonics in three-Phase PWM inverter using auxiliary partial resonant circuit)

  • 서기영;이현우;김영문;문상필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.137-140
    • /
    • 1998
  • A new SPWM inverter using three-phase boost converter by auxiliary partial resonant with high power factor and high efficiency is proposed. The proposed boost converter is constructed by using a resonant network in parallel with the switch of the conventional boost converter. The devices are switched at zero voltage or zero current eliminating the switching loss. A new Partial resonant boost converter achieves zero-voltage switching (ZVS) or zero-current switching (ZCS) for all switch devices without increasing their voltage and current stresses. This paper introduces elimination of low-order harmonics compared with conventional SPWM inverter and SPWM inverter using three-phase boost converter by auxiliary Partial resonant.

  • PDF

부분공진 기법이 적용된 ZVCS DC-DC 초퍼에 관한 연구 (A Study on ZVCS DC-DC Chopper by using Partial Resonant Method)

  • 곽동걸
    • 마이크로전자및패키징학회지
    • /
    • 제15권1호
    • /
    • pp.59-64
    • /
    • 2008
  • 최근 DC-DC 초퍼의 소형경량화 및 저소음화를 위해서 초퍼에 사용한 전력용 반도체 스위치의 스위칭 주파수를 증대시키고 있다. 이에 따른 스위칭 손실의 증대는 초퍼의 효율을 상당히 감소시키는 요인으로 주어진다. 이를 해결하기 위해 본 논문에서는 초퍼에 사용한 반도체 스위치의 턴-온, 턴-오프를 소프트 스위칭(영전류 또는 영전압 스위칭)으로 동작시켜 스위칭 손실을 최소화하는 새로운 고효율의 DC-DC 초퍼를 제안한다. 제안한 초퍼의 소프트 스위칭 동작은 스위치의 동작 시점에 부분공진 회로가 형성되어 인덕터의 전류와 커패시터의 전압이 영으로 될 때 스위치를 동작시키는 부분공진 기법이 적용된다. 또한 제안한 초퍼에 적용된 부분공진 회로는 승압용으로 사용한 인덕터와 스너버 커패시터에 의해 설계되어 초퍼의 회로 토폴로지가 간단하다. 컴퓨터 시뮬레이션과 실험결과를 통해 제안한 DC-DC 초퍼의 타당성이 입증된다.

  • PDF

풀화재를 이용한 터널화재 부분배연 모델실험 (Reduced-Scale Experiments of the Partial Smoke Extraction System in Tunnel Fires)

  • 이의주;유용호
    • 한국화재소방학회논문지
    • /
    • 제20권4호
    • /
    • pp.58-64
    • /
    • 2006
  • 부분배연설비를 가지고 있는 침매터널에서 화재시 배연효율을 분석하기위해 풀화재를 이용하여 축소모형실험을 수행하였다. 화재가 발생하였을 때 주위 유동이 없는 경우인 자연배연과 임계속도로 제트팬을 가동하는 강제배연의 경우에 터널내의 온도와 연소가스 농도를 측정하였다. 자연배연에 비해 강제배연은 화재발생 초기에 화원과 터널 내 기류와의 급격한 혼합에 의해 성층화 정도가 미미해지고 보다 낮은 온도를 화원주위에서 얻을 수 있었다. 이러한 급격한 혼합은 터널 상부에 위치한 부분제연 갤러리의 효율을 변화시키는데, 자연배연인 경우에 약 30%의 배연효율이 증가되었다. 일산화탄소 농도계측으로 얻어진 배연효율은 등온기체모델을 사용한 선행연구와 비교하여 거의 일치하는 결과를 얻을 수 있었다. 이러한 결과는 침매터널 화재시 승객의 안전한 대피를 위한 부분배연설비의 최적 운전방안으로 제시된다.

터보냉동기의 고효율 운전을 위한 협조 방식 기반의 압축기 대수제어 (Operating Number Control of Compressors Based on Cooperative Logic for a High Efficiency Centrifugal Water Chiller)

  • 정석권;임승관;류근수
    • 설비공학논문집
    • /
    • 제27권5호
    • /
    • pp.233-240
    • /
    • 2015
  • This paper discusses compressors operating number control strategy using cooperative logic to cope with variable partial load for high efficiency of a centrifugal water chiller. The cooperative logic is composed of a speed-up and speed-down controller, enabling smooth operation of compressors and equivalent distribution of thermal load in each compressor. This centrifugal water chiller design can be operated with high efficiency without incurring excessive energy waste and large transient phenomena at partial load states. Simulations in MATLAB and experiments in a real chiller system were conducted and verified the high efficiency control of a centrifugal water chiller achieved by the suggested strategy.

소프트 스위칭에 의한 절연형 벅-부스트 컨버터에 관한 연구 (A Study on Soft Switching Buck-Boost Converter added Electric Isolation)

  • 곽동걸;정도영;이봉섭;최신형;김상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.922-923
    • /
    • 2008
  • This paper is proposed to a novel DC-DC buck-boost converter added electric isolation by using a soft switching method. To be achieved of high efficiency system, the proposed converter is constructed by using a partial resonant circuit. The control switches using in the converter are operated with soft switching for a partial resonant method. The controlling switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the converter efficiency is high. And the proposed converter is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed converter is adopted with system development of high efficiency. The soft switching operation and the system efficiency of the proposed converter is verified by digital simulation and experimental results.

  • PDF

태양광발전을 위한 고효율 승압형 전력변환장치 (The High efficiency Buck Power Conversion System for Photovoltaic Power Generator)

  • 박경원;김영철;김준홍;서기영;고희석;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1997년도 추계학술발표회논문집
    • /
    • pp.88-92
    • /
    • 1997
  • Power conversion system must be increased swiching frequency in order to achieve a small size, a light weight and a low noise, However, the swiches of converter are subjected to high switching power losses and switching stresses. As a result of those, the power system brings on a low efficiency. In this paper, the authors propose a DC-DC boost converter of high power by partial resonant switch method (PRSM). The switching devices in a proposed circuit are operated with soft swiching and the control technique of those is simplified for switch to drive in constant duty cycle. The partial resonant circuit makes use of a inductor suing step up and a condenser of loss-less snubber. Also the circuit has a merit which is taken to increase of efficiency, as if makes to a regeneration at input source of accumulated energy in snubber condenser without loss of snubber in conventional cirvuit. The result is the the switching loss is very low and the efficiency of system is high. The proposed converter is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

Analysis of partial resonant AC-DC converter for high power and power factor

  • Mun, Sang-Pil;Kim, Si-Lyur;Lee, ki-Youn;Hyun-Woo;Katsunori taniguchi, Katsunori-Taniguchi
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.920-927
    • /
    • 1998
  • This paper proposed that an Analysis of a partial resonant AC-DC converter for high power and power factor operates with four choppers connecting to a number of parallel circuit. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative results on computer are included to confirm the validity of the analytical results. The partial resonant circuit makes use of an inductor using step-down and a condenser of lose-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in a partial resonant circuit makes charging energy regenerated at input power source for resonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used

  • PDF

부분방전을 이용한 초고압 지중 송전 절연 케이블 내부 결함의 패턴분석 (Pattern Analysis of the Defects within the Cable Insulation for UHV Underground Transmission Using Partial Discharge)

  • 박재화;이광열;채석;오영석;김학성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.175-179
    • /
    • 1998
  • The insulation of cable which used for Ultra-High Voltage(UHV) underground power transmission requires excellent insulation capability for high voltage. The typical insulation materials are used XLPE, EPR, etc, but insulation efficiency of these is affected by void or alien substances, existed at the inside of insulators. In this paper, the partial discharge patterns of the defects within insulation cable are observed and analyzed. In this test, void, fiber and metal inclusions which possibly exist in cables, are simulated and investigated the patterns of partial discharges for each models Also the relations between calculated field strength and the insulation breakdown voltage. The experiment shows distinct partial discharge patterns in accordance with the kinds of defects within Insulation cable.

  • PDF