• 제목/요약/키워드: partial discharge inception voltage

검색결과 54건 처리시간 0.023초

PD Signal Time-Frequency Map and PRPD Pattern Analysis of Nano SiO2 Modified Palm Oil for Transformer Insulation Applications

  • Arvind Shriram, R.K.;Chandrasekar, S.;Karthik, B.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.902-910
    • /
    • 2018
  • In recent times, development of nanofluid insulation for power transformers is a hot research topic. Many researchers reported the enhancement in dielectric characteristics of nano modified mineral oils. Considering the drawbacks of petroleum based mineral oil, it is necessary to understand the dielectric characteristics of nanofluids developed with natural ester based oils. Palm oil has better insulation characteristics comparable to mineral oil. However very few research reports is available in the area of nanofluids based on palm oil. Partial discharge (PD) is one of the major sources of insulation performance degradation of transformer oil. It is essential to understand the partial discharge(PD) characteristics by collecting huge data base of PD performance of nano modified palm oil which will increase its confidence level for power transformer application. Knowing these facts, in the present work, certain laboratory experiments have been performed on PD characteristics of nano $SiO_2$ modified palm oil at different electrode configurations. Influence of concentration of nano filler material on the PD characteristics is also studied. Partial discharge inception voltage, Phase resolved partial discharge (PRPD) pattern, PD signal time-frequency domain characteristics, PD signal equivalent timelength-bandwidth mapping, Weibull distribution statistical parameters of PRPD pattern, skewness, repetition rate and phase angle variations are evaluated at different test conditions. From the results of the experiments conducted, we came to understand that PD performance of palm oil is considerably enhanced with the addition of $nano-SiO_2$ filler at 0.01%wt and 0.05%wt concentration. Significant reduction in PD inception voltage, repetition rate, Weibull shape parameter and PD magnitude are noticed with addition of $SiO_2$ nanofillers in palm oil. These results will be useful for recommending nano modified palm oil for power transformer applications.

침 전극 기울기에 따른 초고압 절연체 XLPE의 부분방전 패턴해석 (Analysis of Partial Discharge Pattern according to Needle Electrode Slope in XLPE for Ultra High Voltage insulators)

  • 안병철;김탁용;이강원;이덕진;신종렬;이충호;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.162-163
    • /
    • 2006
  • XLPE is used to insulator for Ultra High Voltage power cable. It is easy to processing also has a good insulating property. The study for diagnosis of lifetime and improvement is proceeding continuously. In this paper, it is investigated partial discharge distribution according to slope of needle electrode 0, 20, $40^{\circ}$. Applied voltage is 0.5 [kV/s] by step form for inception voltage. As the result of study, we conformed that increase of slope led to reduce of discharge number and total discharge quantity.

  • PDF

부분방전 측정에 의한 하이브리드차량 견인전동기의 절연성능평가 (Evaluation on Insulation Performance of Traction Motors for a Hybrid Vehicle by Partial Discharge Measurement)

  • 박대원;박찬용;최재성;길경석;이강원
    • 한국철도학회논문집
    • /
    • 제12권2호
    • /
    • pp.249-253
    • /
    • 2009
  • 본 논문에서는 부분방전 측정에 의한 하이브리드 차량용 견인전동기의 절연평가에 대하여 기술하였다. 부분방전법은 효과적인 비파괴시험으로 저압용 전기전자기기의 절연성능평가에 사용되어 왔다. 부분방전 측정시스템은 결합회로망, 저잡음 증폭회로 및 주변 전자회로로 구성되며, 주변 잡음의 영향을 최소화하기 위하여 차폐함내에 설치하였다. 교정실험으로부터 부분방전 측정시스템의 주파수 대역은 $1[MHz]{\sim}30[MHz]$ (-3[dB]), 감도는 19[mV/pC]로 평가되었다. 기사용 전동기와 신품 전동기에서 방전개시전압(DIV)과 겉보기 전하량(q)을 측정한 결과, 기사용 전동기의 방전개시전압은 $1,100[V_{rms}]$, 겉보기 전하량은 105[pC], 신품 전동기에서의 방전개시전압은 $1,400[V_{rms}]$, 겉보기 전하량은 84[pC]이었다. 방전개시전압과 전하량을 비교함으로써 견인전동기의 절연상태를 평가할 수 있었다.

Defect Diagnosis of Cable Insulating Materials by Partial Discharge Statistical Analysis

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Jong-Yong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권1호
    • /
    • pp.42-47
    • /
    • 2010
  • Polymer insulating materials such as cross linked polyethylene (XLPE) are employed in electric cables used for extra high voltage. These materials can degrade due to chemical, mechanical and electric stress, possibly caused by voids, the presence of extrinsic materials and protrusions. Therefore, this study measured discharge patterns, discharge phase angle, quantity and occurrence frequency as well as changes in XLPE under different temperatures and applied voltages. To quantitatively analyze the irregular partial discharge patterns measured, the discharge patterns were examined using a statistical program. A three layer sample was fabricated, wherein the upper and lower layers were composed of non-void XLPE, while the middle layer was composed of an air void and copper particles. After heating to room temperature and $50^{\circ}C$ and $80^{\circ}C$ in silicone oil, partial discharge characteristics were studied by increasing the voltage from the inception voltage to the breakdown voltage. Partial discharge statistical analysis showed that when the K-means clustering was carried out at 9 kV to determine the void discharge characteristics, the amount discharged at low temperatures was small but when the temperature was increased to $80^{\circ}C$, the discharge amount increased to be 5.7 times more than that at room temperature because electric charge injection became easier. An analysis of the kurtosis and the skewness confirmed that positive and negative polarity had counterclockwise and clockwise clustering distribution, respectively. When 5 kV was applied to copper particles, the K-means was conducted as the temperature changed from $50^{\circ}C$ to $80^{\circ}C$. The amount of charge at a positive polarity increased 20.3% and the amount of charge at a negative polarity increased 54.9%. The clustering distribution of a positive polarity and negative polarity showed a straight line in the kurtosis and skewness analyses.

권선형기기 On-line 부분방전 측정용 6-6kV급 Ceramic Coupler의 신뢰성 평가 (Evaluation of Reliability on the 6.6kV Class Ceramic Coupler for On-line Partial Discharge Measurement in Winding Machines)

  • 강동식;김용주;윤영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.69-75
    • /
    • 2005
  • In order to improve the reliability of high voltage rotating machines and mold transformers, it is necessary to understand the breakdown mechanism and life assessment of the high voltage winding parts. Especially the on-line PD test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting the electrical machines, this method has been proven the major testing technology. Capacitive couplers have been the most widely used sensors for the on-line partial discharge detection in rotating machines nowadays. This paper deals with the electrical characteristics and long-term reliability of a ceramic coupler(CC), which can be easily mounted into high voltage input terminal part, has been developed and tested to continuously measure PD activity during operating condition. This paper presents electrical characteristics (dielectric loss angle, capacitance, PD inception level, breakdown voltage, and frequency response bandwidth) and long-term life test result of the developed 6.6 kV class on-line ceramic coupling sensor. It was found that this sensor had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz. Also, the voltage life of the 6.6kV class ceramic coupler was calculated over 60 years.

부분방전법을 이용한 점화코일의 안정도 해석 (Stability Analysis of the Ignition Coil using Partial Discharge)

  • 박희두;김탁용;신현택;김원종;신종열;홍진웅
    • 한국안전학회지
    • /
    • 제21권1호
    • /
    • pp.53-58
    • /
    • 2006
  • This paper has been addressed on the discharge characteristics of the ignition coil by Weibull function. It analyzed discharge number and amount of discharge using Weibull distribution to know the inter-relationship between partial discharge and mileage. We detected the discharge which happens for 10 seconds. The applied voltage increased by 0.5[kV] at discharge inception voltage. We diagnosed failure rate using the shape parameters. As a result, we confirmed that the failure rate was increased, because the shape parameter showed the value of 5 according to increasing mileage degradation. Also, it is considered to increase the degradation of inner insulator of ignition coil. Because failure rate of virgin was increased from 0[%] to 25[%] after degradation, stability analysis of the ignition coil using Weibull analysis is possible.

고온초전도 케이블의 절연설계를 위한 적층효과 (Multi-layered Effect for the Insulation Design of a HTS Cable)

  • 곽동순;천현권;김해종;조전욱;정순용;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.950-955
    • /
    • 2005
  • For the insulation design of a high temperature superconducting(HTS) cable, three kinds of design method were proposed, which used AC and impulse withstand voltage and partial discharge inception strength. However, the designed insulation thickness by AC and impulse could not be applied to cable fabrication process due to much low electrical breakdown strength. The effect of the multi-layered insulation paper was not considered on the previous insulation design and the insulation thickness by partial discharge inception strength could be applied only. In this paper, the electrical breakdown characteristic, which considered the effect of multi-layered of LPP, was investigated to design the insulation thickness.

Electrical Characteristic Assessment of Nomex Paper for Distribution Transformers

  • Song, Il-Keun;Jung, Jong-Wook;Lee, Byung-Sung;Kwak, Hee-Ro
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권3호
    • /
    • pp.86-90
    • /
    • 2003
  • This paper describes the electrical characteristics of Nomex paper employed as an insulating material for distribution transformers. The relative permittivities (dielectric constants) and tan$\delta$ (dielectric dissipation factors) were measured as dielectric characteristics and the partial discharge inception voltages (PDIVs) and breakdown voltages were also measured as electrical strength characteristics of Nomex paper. As a result, the permittivity and tan $\delta$ of Nomex paper demonstrated both temperature and frequency dependency. Of particular note, the permittivity of 0.18 mm Nomex paper was 2.4 according to the ASTM condition, The PDIVs and breakdown voltages were almost linearly increased with the thickness of Nomex paper. Furthermore, its electrical strength was superior to conventional Kraft paper.

고압 회전기 On-line 부분방전 측정용 Ceramic Coupler 특성 (Characteristics of Ceramic Coupler for On-line Partial Discharge Measurement in High Voltage Rotating Machines)

  • 강동식;윤대희;김용주;이홍식;윤영호;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권5호
    • /
    • pp.204-212
    • /
    • 2002
  • In order to improve the reliability of high voltage rotating machines, it is necessary to understand the breakdown mechanism of stator windings. Especially partial discharge(PD) inception and growth are important in stator winding insulation. Recently, many research on the diagnosis of stator winding insulation for large rotating machines have been developed since the 1970s. Capacitive couplers have been the most widely used sensor for on-line partial discharge detection in rotating machines. This paper deals with the electrical on-line monitor characteristics of ceramic coupler(CC) which has been developed to continuously measure the PD activity in operating high voltage motor stator windings on site. We investigated the electrical characteristics(PD quantity, breakdown voltage and frequency response) to develop CC. This paper presents frequency characteristics and laboratory test result to compare conventional 80([F] epoxy-mica coupler(EMC) and 105[pF] CC for PD measurement with 6.6㎸ model stator windings.

$SF_6$ 가스 중의 삼중점 절연파괴 예측기술에 관한 연구 (Study on Insulation Prediction of Triple Junction in $SF_6$)

  • 조용성;정진교;이우영
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.989-993
    • /
    • 2009
  • Triple junction which consists of three media(electrode, insulator, and gas) should be considered in designing of high voltage equipments due to the electric field enhancement. In this paper, positive lightning impulse breakdown voltage is predicted based on the streamer theory for simplified insulator models and 72.5kV spacer with varying the triple junction geometry and gas pressure, and the results are compared to the experimental results. The electric field coefficient concept is also applied in order to evaluate the partial discharge inception voltage and the surface flashover voltage from the streamer inception voltage. The application of this method using the constant electric field coefficient of 1.3 and 0.66 is possible for evaluating the triple-junction insulation of the simplified insulator and the 72.5kV spacer respectively. The error rate is under 10%.